Loading...
HomeMy WebLinkAboutUNDERLAYMENT PRODUCT APPROVAL4/19/2021 Florida Building Code Online I � I CIS Home 1 ing in I User Registration I Hot Topics I Submit Surcharge j Slats a Facts Publications contact Us I eCiS Site Map Links I ,Search ba 1^ _"i Product Approval USER: Public User I omVa Menu > Product or ARg ration Search > 6iinlicatlon List > Application Detail FL # FL34539 Application Type New Code Version 2020 Application Status Approved Comments Archived Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC Address/Phone/Email 1 Owens Corning Parkway Toledo, OH 43657 (740)587-3562 greg.keeler@owenscoming.com Authorized Signature Greg Keeler greg.keeler@owenscornlng.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Undedayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Zachary R. Priest Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence EL34539 RO COI OCR20001 2020 FBC Eval TRI-BUILT Granular fig Referenced Standard and Year (of Standard) Standard Year ASTM D 1970 2015 ASTM D 226 2009 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method I. Option D https://Roridabuilding.org/prlpr app tl.aspx?param=wGEVXQwtDgtDQlYvhxNfJgGNYw2SlyWsijWca/o2fsUEu7iGvOVs7lRvA°/a3d%3d 112 4/19/2021 Florida Building Code Online Date Submitted 10/14/2020 Date Validated 10/15/2020 Date Pending FBC Approval 10/25/2020 Date Approved 12/16/2020 Surmma!j of Products l FL # Model, Number or Name Description 34539.1 TRI-BUILT Granular Underlayment A self -adhered underlayment used as an altemative to ASTM D 226, Type II roofing felt. Limits of Use Installation Instructions Approved for use In HVHZ: No FL34539 RO Ii OCR20001 2020 FBC Eval TRI-S, UI Approved for use outside HVHZ: Yes Grat]ular.Rdf Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports F134539 RO AE OCR20001 2020 FBC Eva[ TRI-BUILT Granular.Ddf Created by Independent Third Party: Yes Contact Us:: 2601 Slalr Stone Road, Tallahassee FL 32399 phone: 850487:j The State of Florida Is an ANEW employer. Coggright 2007-2013 State of Florida.:: PrIvalu StateMgnt :: Acoesslb[ilix Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 8S0.487.139S. *Pursuant to Section 4S5.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails Provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please Provide the Department with an email address which can be made available to the public. 7b determine If you are a licensee under Chapter 455, F.S., please click L,gr . Product Approval Accepts: Credit Card Safe httpsJlfloridabuilding.orglpdpr app_dtl.aspx?param=wGEVXQwtDgIDQIYvhxNflgGNYw2SIyjWsiWc%2fsUEu7iOvOVs7lRvA%3d%3d 2/2 Certificate of Authorization No. 29824 s°CREEK 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)4803421 EVALUATION REPORT FLORIDA BUILDING CODE, 7'" EDITION (2020) Manufacturer: BEACON SALES ACQUISITIONS, INC. Issued October 14, 2020 c/o OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Corning Parkway Toledo, OH 43657 (800)438-7465 www.owenscornina com Manufacturing Location: Houston, TX Brentwood, NH Quality Assurance: PRI Construction Materials Technologies, LLC (QUA9110) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.1, 1507.1.1.1 Properties: Physical properties REFERENCES Entity Report No. Standard Year PRI Construction Materials Technologies (TST6049) OCF-294-02-01 ICC-ES AC 188' 2012 ICC-ES AC 48 2012 PRI Construction Materials Technologies (TST6049) OCF-338-02-01 ASTM D 1970 2015a 'Determined to be equivalent to ASTM D 226-09, Type It PRODUCT DESCRIPTION TRI-BUILT Granular A self -adhered underlayment used as an alternative to ASTM D 226, Type II roofing felt. Underlayment The underlayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See manufacturers installation Instructions for further detail. OCR20001 FL34539 Page 1 of 3 This evaluation report Is provided for State of Florida product approval under Rule B1G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. C�`Y Y! BEACON SALES ACQUISITIONS, INC. f'C K c/o OWENS CORNING ROOFING AND ASPHALT LLC TECHNICAL SERVICES, LLC TRI43UILT Granular Underlayment APPLICATION Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutting joints. Min. slope: 2:12 or in accordance in with FBC Application: Prior to beginning installation, the underlayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The underlayment installation shall comply with FBC Table 1507.1.1.1. The underlayment shall be installed with the roll length parallel to the eave, starting at the save fold the undedayment away from eave onto itself. The underlayment shall be installed direct -to -decking with the lower release backer removed and pressed firmly Into place to ensure complete contact with the deck. Repeat with upper release backer. Overlap successive courses with minimum 3" side laps and minimum 6" staggered end laps. In steep -slope applications (>6:12), it is permissible to nail the underlayment 12- inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the underlayment). For valley applications, the roll shall be applied centered along the valley prior to Installing the underlayment at the save and overlapped a minimum of 6-inches. For save protection, the underlayment should extend to a point 1 B-inches beyond the Interior wall. Min. Application Temperature: 40"F; Contact the manufacturer when installing at temperatures below the minimum application temperature. Allowable roof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted in accordance with the FBC. OCR20001 FL34539 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not specifically addressed herein. C [l BEACON SALES ACQUISITIONS, INC. ■ Go OWENS CORNING ROOFING AND ASPHALT LLC TECHNICAL SERVICES, LLC TRI-BUILT Granular Underlayment LIMITATIONS 1) This evaluation report is not for use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Wind uplift resistance in not within scope of this evaluation. 4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application Instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 6) The underlayment may be used as described in other current FBC product approval documents. 7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically fastened through the underlayment to the roof deck. 8) The underlayment shall not be installed over existing roof coverings. 9) The underlayment shall be installed starting at the eave In horizontal layers such that the laps shed water from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a minimum of 24-inches from the preceding course. 10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 71" Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer. V No 74021 IZ S9 STATE OF ' W CERTIFICATION OF INDEPENDENCE 2020.10.14 15:45:22 -041001 Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distribuling products under this evaluation. CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor volt acquire, a financial interest in any other entity involved in the approval process of me product. END OF REPORT OCR20001 FL34539 Page 3 of 3 This evaluation report Is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.