FL #
FL34539
Application Type
New
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Beacon Sales Acquisitions, Inc. c/o Owens Corning Roofing and Asphalt LLC
Address/Phone/Email 1 Owens Corning Parkway
Toledo, OH 43657
(740)587-3562
greg.keeler@owenscoming.com
Authorized Signature Greg Keeler
greg.keeler@owenscornlng.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License
PE-74021
Quality Assurance Entity
PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date
12/31/2024
Validated By
Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence EL34539 RO COI OCR20001 2020 FBC Eval TRI-BUILT Granular fig
Referenced Standard and Year (of Standard) Standard Year
ASTM D 1970 2015
ASTM D 226 2009
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Method I. Option D
https://Roridabuilding.org/prlpr app tl.aspx?param=wGEVXQwtDgtDQlYvhxNfJgGNYw2SlyWsijWca/o2fsUEu7iGvOVs7lRvA°/a3d%3d 112
4/19/2021 Florida Building Code Online
Date Submitted
10/14/2020
Date Validated
10/15/2020
Date Pending FBC Approval
10/25/2020
Date Approved
12/16/2020
Surmma!j of Products l
FL #
Model, Number or Name
Description
34539.1
TRI-BUILT Granular Underlayment
A self -adhered underlayment used as an altemative to ASTM D
226, Type II roofing felt.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL34539 RO Ii OCR20001 2020 FBC Eval TRI-S, UI
Approved for use outside HVHZ: Yes
Grat]ular.Rdf
Impact Resistant: N/A
Verified By: Zachary R. Priest PE-74021
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: See evaluation report for limits of use.
Evaluation Reports
F134539 RO AE OCR20001 2020 FBC Eva[ TRI-BUILT
Granular.Ddf
Created by Independent Third Party: Yes
Contact Us:: 2601 Slalr Stone Road, Tallahassee FL 32399 phone: 850487:j
The State of Florida Is an ANEW employer. Coggright 2007-2013 State of Florida.:: PrIvalu StateMgnt :: Acoesslb[ilix Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 8S0.487.139S. *Pursuant to Section 4S5.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
Provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
Provide the Department with an email address which can be made available to the public. 7b determine If you are a licensee under Chapter 455, F.S., please click L,gr .
Product Approval Accepts:
Credit Card
Safe
httpsJlfloridabuilding.orglpdpr app_dtl.aspx?param=wGEVXQwtDgIDQIYvhxNflgGNYw2SIyjWsiWc%2fsUEu7iOvOVs7lRvA%3d%3d 2/2
Certificate of Authorization No. 29824
s°CREEK 17520 Edinburgh Drive
Tampa, FL 33647
TECHNICAL SERVICES, LLC (813)4803421
EVALUATION REPORT
FLORIDA BUILDING CODE, 7'" EDITION (2020)
Manufacturer:
BEACON SALES ACQUISITIONS, INC. Issued October 14, 2020
c/o OWENS CORNING ROOFING AND ASPHALT
LLC
1 Owens Corning Parkway
Toledo, OH 43657
(800)438-7465
www.owenscornina com
Manufacturing Location:
Houston, TX
Brentwood, NH
Quality Assurance:
PRI Construction Materials Technologies, LLC (QUA9110)
SCOPE
Category:
Roofing
Subcategory:
Underlayments
Code Sections:
1507.1.1, 1507.1.1.1
Properties:
Physical properties
REFERENCES
Entity
Report No. Standard Year
PRI Construction Materials Technologies (TST6049) OCF-294-02-01 ICC-ES AC 188' 2012
ICC-ES AC 48 2012
PRI Construction Materials Technologies (TST6049) OCF-338-02-01 ASTM D 1970 2015a
'Determined to be equivalent to
ASTM D 226-09, Type It
PRODUCT DESCRIPTION
TRI-BUILT Granular A self -adhered underlayment used as an alternative to ASTM D 226, Type II roofing felt.
Underlayment The underlayment is composed of SBS modified asphalt with a fiberglass mat internal
reinforcement and is surfaced with granules. The product is supplied with a nominal
thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. See
manufacturers installation Instructions for further detail.
OCR20001 FL34539 Page 1 of 3
This evaluation report Is provided for State of Florida product approval under Rule B1G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
C�`Y Y! BEACON SALES ACQUISITIONS, INC.
f'C K c/o OWENS CORNING ROOFING AND ASPHALT LLC
TECHNICAL SERVICES, LLC TRI43UILT Granular Underlayment
APPLICATION
Roof Deck: The roof deck shall be constructed of closely fitted plywood sheathing for new or
existing construction. Deck shall be installed in accordance with FBC
requirements. Roof decks shall have no more than 1/8" gap at abutting joints.
Min. slope: 2:12 or in accordance in with FBC
Application: Prior to beginning installation, the underlayment shall be unrolled and allowed to
relax for a minimum of 3-5 minutes. The underlayment installation shall comply
with FBC Table 1507.1.1.1.
The underlayment shall be installed with the roll length parallel to the eave, starting
at the save fold the undedayment away from eave onto itself. The underlayment
shall be installed direct -to -decking with the lower release backer removed and
pressed firmly Into place to ensure complete contact with the deck. Repeat with
upper release backer. Overlap successive courses with minimum 3" side laps and
minimum 6" staggered end laps.
In steep -slope applications (>6:12), it is permissible to nail the underlayment 12-
inches on -center as needed (nails shall be installed perpendicular to deck with the
nail heads flush to the top surface of the underlayment).
For valley applications, the roll shall be applied centered along the valley prior to
Installing the underlayment at the save and overlapped a minimum of 6-inches.
For save protection, the underlayment should extend to a point 1 B-inches beyond
the Interior wall.
Min. Application Temperature: 40"F; Contact the manufacturer when installing at temperatures below the
minimum application temperature.
Allowable roof coverings: Mechanical attachment of asphalt shingles and slate shingles shall be permitted in
accordance with the FBC.
OCR20001 FL34539 Page 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor Imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
C [l BEACON SALES ACQUISITIONS, INC.
■ Go OWENS CORNING ROOFING AND ASPHALT LLC
TECHNICAL SERVICES, LLC TRI-BUILT Granular Underlayment
LIMITATIONS
1) This evaluation report is not for use in the HVHZ.
2) Fire Classification is not within the scope of this evaluation.
3) Wind uplift resistance in not within scope of this evaluation.
4) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published
application Instructions. Where discrepancies exist between these sources, the more restrictive and FBC
compliant installation detail shall prevail.
5) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck
shall be checked for protrusion and corrected prior to underlayment application.
6) The underlayment may be used as described in other current FBC product approval documents.
7) Roof coverings shall not be adhered directly to the underlayment. Roof coverings shall be mechanically
fastened through the underlayment to the roof deck.
8) The underlayment shall not be installed over existing roof coverings.
9) The underlayment shall be installed starting at the eave In horizontal layers such that the laps shed water
from the deck. The first layer shall cover the entire bottom edge of the deck. End laps shall be staggered a
minimum of 24-inches from the preceding course.
10) The underlayment shall be exposed on the roof deck for a maximum duration of 30 days.
11) All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 71" Edition (2020) as evidenced in the referenced documents submitted by the named manufacturer.
V No 74021
IZ
S9 STATE OF ' W
CERTIFICATION OF INDEPENDENCE
2020.10.14
15:45:22
-041001
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical services, LLC does not have, nor will it acquire, a financial Interest in any company manufacturing or distribuling products under this
evaluation.
CREEK Technical Services, LLC Is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation.
Zachary R. Priest, P.E. does not have, nor volt acquire, a financial interest in any other entity involved in the approval process of me product.
END OF REPORT
OCR20001 FL34539 Page 3 of 3
This evaluation report Is provided for State of Florida product approval under Rule 61G20.3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.