Loading...
HomeMy WebLinkAboutMobile Home Inspection Report' St, Lucie County Building & Zoning 2 00 Virginia Avenue Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile / Manufactured homesinus t be accompanied by this completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. y Owner: LYv Date: I I S f98 (Print or type), GOLo M v Address: (Pf ysical Location of HonSe) - "� ff � Ta39a3dOA Year / Manufacturer ? Serial # zii39a 3al� 8 HUD Plate # _ Length i _S - ngle Double ✓ WindZone__e6-G?) X C = In Compliance N = Not in Compliance i = R C PAJ RA&& Fire Safety / Electrical C1. Smoke Detector: Installed Missing ........... 2. Electrical System Checked: Exposed Wiring Other G 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other. 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire GFCI receptacles not where required 5. Electrical Ground:'Chassis Main Panel Gas Pipe Rr%ised 3/9/05 a0 Py Page 1 of 3 :tom Construction --C— 1. Exit Doors Operable: Front Back (Z— 2. Exit Door Locks: Missing Inoperable Other U_ 4. windows: Broken Glass Inoperable C 5. Screens: Missing Damaged 6. Floor System: Joist Decking Area Damaged 7. Interior Paneling: Missing L� oose Damaged G 8. Rodent Proofing: Bottom Board Pipe openings Other 9. Leaks Apparent: Ceiling je—l', Doors Floor Roof _ 10. Vertical tie -down straps: Missing Short Damaged _ 11. Structural modifications since manufactured: YES_ N0-' C 12. Walls: Structurally Unsound Loose Weather tight I ' Plumbing .)1. 1. Trap: Missing Not connected Other 2. Plumbing fixtures: Missing Not installed Not Vented C 3. Relief Valve: Missing Inoperable Other C 4. Drain Waste and Venting Piping: Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditio ning 1. Heating Appliances: Missing Not Connected Other C 2. Deleted Heating/AC system: Not in Other C3. Thermostat: Missing Inoperable C4. Air register's: Missing Inoperable C5. Ducts: Not sealed Missing Collapsed Page 2 of 3 i C 6. Gas furnace Water heater vent: Missing Loose C 7. Return Air: To Furnace To A/C From rooms 8. Range: Vent Hood 9. Gas Valve: Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary 1. Is subject structure found to be fifty (50%) or more damaged or deteriorated? YES No 2. Will a remodeling permit be required? YES NO_ The provisions of the repair and remodeling !code shall ensure safe and livable housing and shall not be more stringent than thosestandards required to"be met in the manufacture of mobile'homs. Such provisions shall include, but not be -)ited to; standards for structural adequac.y,l plumbing, heating, electricals . ys . tems, and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE, THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL.BE PERMITTED TO BE TIED -DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE) WILL BE REQUIRED. ALL SEPARATE -PERMITS .MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTI.ON IS OBTAINED FOR THE TIE -DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE:MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE -DOWN PERMIT HAS BEEN ISSUED. A RE ,, GISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT, SIGN AND AFFIX THEIR SEAL. Date inspected: . 15 60 0) Inspected ,By: 60)� P� Signature required Phone Number`'(M 7b -73 a.� License # , 3113 9 e - a V=98 P.E.aTPage 3 of ; 950 80,TAN DR PORT'.;' PCIE, FL