Loading...
HomeMy WebLinkAboutRoofing Info Sheets F9441- ST. LUCIE ORKM r•; ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) AL t Based on Section 1525 of the Florida Building Code-Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B,C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B,C 2,4,5,6,7 Asphaltic Shingles A, B,D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs LB, D Wood Shingles and A, B, D 1,2,4,5,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16,or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations(Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18,2021 N 3 . ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: WAM 9. W61 License# CCG 13323'kh Job Address 2)010 RN" N•W MOCK LMe- Fort" Rifree . f, 3LA 931 ROOF CATEGORY ❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles WMetal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance El Reroofing ❑Recovering -ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area(SF) SCOID Total(SF) ,.� t. Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. 00, 1� 'r ST. LUCIE WORKS Section C(Low Slope Roof) Surfacing: Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment: manufacturer Zone 1':_.._."oc @ Lap,#Rows @ "00 (If a component is not used,identify as"NA") Zone 1:_.._."oc @ Lap,#Rows @ °00 System Manufacturer: Zone 2:_.._."oc @ Lap,#Rows @ "oo Product Approval No.: Zone 3:_.._."oc @ Lap,#Rows @ moo Number of Fasteners:Per Insulation Board: Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zo a 1: Zone 2: Zone 3: Zone 1':_Zone 1: , Zone 2: Zone 3: Illustrate Co onents Noted and Details as Applicable: Max. Design Pressure,fro the specific produc oval Woo ng, Gutter, Edge Termination, Stripping, system: Flashin , Continuou ant Stri , Base Flashing, Cou erflashing,Coping, Etc.. Deck: I icate: Mean Roof Height, Parapet Height, Height of Base Type: hing,Component Material,Material'Thickness,Fastener Type, astener Spacing or Submit Manufacturers Details that Gauge Thickness: Comply th RAS 111 and Chapter 16.. Slope: Anchor/Base Sh et&No.c Ply(s): Anchor/Base Sheet Fa ener/Bonding Material: FT. u Insulation Base Layer: Base Insultation Size and Thickn s: Parapet Base Insulation Fastener/Bonding terial: Height Top Insulation Layer: Top Insulation Size and Thickness: FT. Top I i lratJon Fastener Mean Base Sheet(s o. Ply(s): Roof Base Sheet Fastener di Material: Height Ply Sheet(s)'&No.of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: ST. LUCIE WORK Section D (Steep Slope Roof System) Roof System Manufacturer: Notice of Acceptance Number: Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations): u Zone 1:'5I'Zone 2e: 51—Zone 2n:'9 Zone 2r:'q/ Zone 3e: Zone 3r: 2$ Deck Type: V�oc , Jam' C�X Roof Slope: Type Underiaymenir ipee'l *Se tic TI hi-0111M PSU ao 5 : 12 Insulation: AJ A Fire Barrier: 'A Ridge Ventilation? Fastener Type&Spacing: I-�� Ql Sh�7� �✓Q1yS 1 's �l��/ Adhesive Type: /V Type Cap Sheet: //A Mean Roof Height: 1 9' Roof Covering: Z lD 901, 5\1 Cri rtl Type&Size Drip Zb q 2- Z Edge: u ST. LUCIE WORK Section E(Tile Calculations) For Moment based tile systems,choose either Method 1 or 2.Compare the values for Mr with the values from Mf.If the Mf values are greater than or equal to the Mrvalues,for each area of the roof,then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x _ --Mg: =Mr, Product Approval M, (Zone 2e: = x 7L = _�—Mg: =Mr2o Product Approval Mf (Zone 2n: x _ --Mg: =Mom, Product Approval Mf (Zone 2r: x I _ —Mg: =Me& Product Approval Mf (Zone 3e: x X _ --Mg: =Mej. Product Approval Mf (Zone 3r: x _ ____a—Mgi =Mrsr Product Approval Mf Method 2"Simplified Tile Calculations Per Table Below" Required Moment of Resistance(Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' 30' 40' 2:12 34.4 42.2 3:12 32.2 36. 37.4 39.8 4:12 30.4 32.2 3 .8 35.1 37.3 5:12 28.4_ 30.1 A1.6 32.8 34.9 6:12 26.4 28.0 .4 30.5 32.4 u 7:12 4.4 25.9 2 28.2 30.0 *Must be used in conjunction with a list f moment based tile systems • For Uplift based tile systems use Method ompare the values for F'with the values for Fr If the F'values are greater than or equal to the Fr values,for each area of the roo, en the tile attachment method is acceptable. Method 3"Upli ased Tile Calculations Per RAS 12T (Zone 1: x L =x W:= )-W: cos =Fri Product Approval F' (Zone 2e: x L =x W:= )-W: cos r =Fr2e Product Approval F' (Zone 2n: =x W:= )-W: cos r — 2" Product Approval F' (Zone 2r: x L -x W:= )-W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x = )-W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= )-W: cos r =Fr3r duct Approval F' Wh'eteko Obtain Information Description Symbol Where to find Design Pres From applicable table in RAS 127 or by an engineering analysis r,3e,3r prepared by PE based on ASCE 7 Mean Roof H t H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity Mr Product Approval y Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.