Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approvals (2)
r O RECEIVED ��//��pp ���� APR 2 9 2021 �9. R E�J O E�tJ E Q%g Department N EMO! etc. 5`.Lucie-Cun�/ (CODE COMPUANCE Certificate of Authorization#32455 L 353 Christian Street,Unit#13 ST. LUME COUNT' Oxford,CT06478 Faar (203)262-9245 ENGINEER EVALUATE TEST P01 CONSULT Boral Roofing Evaluation Report M35710.12.10-R12 7575 Irvine Center Drive,Suite 100 FL14317-R11 Irvine,CA.92618 ate of Issuance:12/21/2010 (602)269-2288 Fily C®pj Revision 12:11/25/2020 SCOPE: This Evaluation Report is issued under Rule 61G 0-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Budding Code. The products described herein have been evaluated for compliance with the 7eh Edition(2020)Florida Buitding Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is lid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location() changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s), NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT:The Florida Product Approval Nu ber (FL#) preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portio i of the Evaluation Report is displayed, then it shall be done in its entirety, INSPECTION: Upon request,a copy of this entire Ev fluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspectio i at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 througi 16. Prepared by: �t�,durhl f,,% Robert J.M.Nieminen P.E. t O� ^e'4 T` The facsimile seal appearing was authorized by Robert _'�� ,, Nieminen,P.E.on d document. This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 electronically signed document, CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquir ,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquir a,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETZ Z,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018,NEMO ETC,LLC _ e I(NNEMOJetc. ROOFING COMPONENT EVALUATION: o• _ Product Category: Roofing Sub-Category: Underlaymen Compliance Statement: Boral Roof Un erlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections f the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards, ompliance is subject to the Installation Requirements and Limitations /Conditions of Use set forth herein. D D Section Pro a Standard Year 1504.3.1 Wind rests nce UL 1897 2015 1507.1.1,1507.2.4,1507.2.9.2/ Material st ndard ASTM D1970 2015 R905.1.1,R905.2.8.2 1507.3.3/R905.3.3 Material st ndard FRSA/TRI,Sixth Edition 2018 TAS 110 Material st ndard TAS 103 2020 Entity Examination Reference Date ERD(TST 6049) ASTM D1970/0 4798 M36790.07.11 09/30/2011 ERD(TST 6049) ASTM D226,D1970 B40380.08.12 08/28/2012 ERD(TST 6049) TAS 103-20(tensile adhesion) C41420.09.12-2 09/11/2012 ERD(TST 6049) ASTM D1970(ac hesion) B41940.09.12 09/13/2012 ERD(TST 6049) TAS 103-20(ten ile adhesion) B47390.07.14-1 07/31/2014 ERD(TST 6049) TAS 103-20(ten ile adhesion) B47390.09.14 09/04/2014 OC(PDM1838) Physical Propert es Equivalency statement 11/02/2017 PRI(TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI(TST 5878) ASTM D1970 NEI-029-02-01:11EV 12/03/2010 PRI(TST 5878) TAS 103-20(ten Ile adhesion) NEI-046-02-01REV 12/17/2010 PRI(TST 5878) FRSA/TRI April 2 12 NEI-076-02-01 02/14/2011 PRI(TST 5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI(TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI(TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI(TST 5878) TAS 103-20(ten ile adhesion) DAPF-002-02-01 03/08/2018 PRI(TST 5878) ASTM D1970(adhesion) OCF-443-02-01 10/11/2018 UL,LLC.(QUA 9625) Quality Assurance Service Confirmation 08/21/2017 UL,I.I.C.(QUA 9625) Quality Assurance Florida BCIS Current Product Material Standard Plant(s) Description .1 Boras®TileSeal 50"T ASTM D1970 Brentwood, nominal 50-mil thick,polyester-surfaced,self-adhering SBS NH modified bitumen roof underlayment Boral"TileSeal"T ASTM D1970 and I Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS FRSA/TRI 09-18 NH modified bitumen roof underlayment 4.3 Boral®MetalSeal"T ASTM D1970 and Brentwood, nominal 60-mil thick,polyester-surfaced,self-adhering SBS FRSA/TRI 09-18 NH modified bitumen roof underlayment 4.4 GatorSeal® ASTM D1970 Brentwood, nominal SS-mil thick,granule-surfaced,fiberglass reinforced, NH self-adhering SBS modified bitumen roof underlayment 4.5 Citadel°Plus ASTM D1970 Brentwood, nominal 48-mil thick,fabric-surfaced,fiberglass reinforced, NH self-adhering SBS modified bitumen roofing underlayment for use as a base-layer in multi-ply underlayment systems NEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization N31455 7T"EDITION(20 0)FBC NON-HVHZ EVALUATION FL14317-R11 Boras Roof Ur derlayments;(602)269-2288 Revision 12:11/25/2020 Page 2 of 6 ONEM01eft. 0 5.1 This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specific Ily for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not Include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulatic n. 5.5 Boral Roof Underlayments may be used wi h any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combine J with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by-itself beneath the stated roof covers. Refer to the installation instructions for multi-ply underlayment options. TAB 1' RODF:COVER OPTIONS FBCSection: 1507.2 2507 1507.4&1507.5 1507.7 1507.8&1507.9 Asphalt Clay and Con ete:Tile Metal Slate or wood Underlayment Mechanical Adhesive- Slate Type Shingles Attach Set Shingles Panels Shingles Shingles&Shakes Boral TileSeal SORT Yes No No Yes Yes Yes Yes (Joint ships,1507.1.1.3/005.1.1.3) Boral TileSealHT Yes Yes Yes Yes Yes Yes Yes (see 5,6.1) Gointstrips,,1507.1.1.3/R905.1.1.3) Boral MetalSealHT Yes Yes Yes Yes Yes Yes Yes (See 5.6.1) (joint strips,1507.1.1.3/R905.1.1.3) GatorSeal Yes N0 No No No Yes Yes (joint strips,1507.1.1.3/R905.1.1.3) 5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations. ' TABLElA A41.QWABCE.__NDERLAYMENT�:TILEADHESIVECOIUIBINAT1DNSi. : ,,, Underlayment I Adhesive Florida Product Approval Boral TileSealHT or Boral MetalSeall DAP Foam"Touch'n Seal StormBond Roof Tile Adhesive" FL14506 Boral TileSealHT or Boral MetalSealHT DAP Foam"Touch'n Seal StormBond 2 Two-Component FL21374 Polyuretha ne Roof Tile Adhesive" Boral TileSealHT or Boral MetalSealw Dupont"Tile Bond'"Roof Tile Adhesive" FL22525 Boral TileSealHT or Boral MetalSeall ICP Adhesilies and Sealants"Polyset®AH-160" FL6332 Boral TileSealHT or Boral MetalSealHT ICP Adhesi ies and Sealants"Polyset°RTA-1" FL6276 1 Refer to Tile Manufacturer's orAdhesive Manufactu is Florida Product Approval for Overturning Moment Resistance Performance. MEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization#32455 7"EDITION(20 0)FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof U iderlaVirients,(602)269-2288 Revision 12:12/25/2020 Page 3 of 6 0NEM01LmtC. 5.7 Allowable Substrates: TABLE$:SUBSTRATE.OPTIONS FOR ADHERED:UNDERLAYIVIENTS Underlayment Application Primer substrates (Optional)ASTM D41 plywood Citadel Pius, ral TIIeSeal`5 or, atororai self-adheri g none ASTM D226 Type II felt or Citadel Plus TileSeal ,Boral MetalSeal or GatorSeal ASTM D41 metal(flashing metal,valley metal,etc.) Boral TileSeal"r,Boral MetalSeal"r self-adheri g I (Optional)ASTM D41 OSB Boral TileSeal self-adheri g Hr (Optional)ASTM D41 Huber"Zip Deck" None G-P Gypsum"DensDeck Prime" 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructio is,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or 11905.1.1. 5.8.2 For use under the roof systems, attac iment shall be in accordance with the manufacturer's installation instructions,but not less than Section 51.3 herein. 5.8.3 Wind Resistance for Underla ment S stel s in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roo}'Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resis ante based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin f safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the s lected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Rot Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-120.0 post: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional)ASTM D41 to the plywood deck Base Ply: Citadel Plus,self-adhered Cap Ply: Boral TileSeal"r or Boral MetalSeal"r,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y4"ring 5 hank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure=-142.5 psf: Deck: Min. 15/32-inch plywood o meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Ply: Boral TileSeal"r or Boral ME talSeal"r,self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring hank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products# 10 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Ply: Boral TIIeSeal"r or Boral MetalSeal"r,self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring (hank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. NEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization#32455 7T"EDITION(20 O)FBC N0N-HVHZ EVALUATION FL14317-R11 Boral Roof Ur derlayments;(602)269-2288 Revision 12;31/25/2020 Page 4 of 6 #4 Maximum Design Pressure=-210 0 psf: ONEMO�etc. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK#89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Ply: Boral TileSeal"T or Boral M alSeal";self-adhered,and back-nailed within the selvedge-edge side laps using 12 ga.x 1%"ring 5 hank nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-120 0 psf: Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional)Citadel Plus,self- dhered Cap Ply: Boral TileSeal"T or Boral Me alSeal"T,self-adhered #6 All other direct-deck, adhered underla ment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf. 5.9 Exposure Limitations: L: Tp6 3r IsXPOSURE'LIiV1ITATION9 Maximum Underlayment Prepared Roof Cover Installation Type Exposure (days) GatorSeal Mechanically attached 30 Boral TileSeal 50"T Mechanically attached 180 oral TileSeal"Tor Boral MetalSeal"T Adhesive-set the roof system 30 Mechanically attached 180 Citadel Plus(base ply in multi ply underlayment systems nly) N/A 180 (prior to placement of subsequent underlayment) 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. Y ABLE 1LE SLIPRAGE f.l. ITA710Rf5 FOR::DIREGT DEGlf TILE N5T`ALI.AT10 Underlayment* Tile Profile Staging Method Maximum Slope Boral TileSeal"Tor Boral MetalSeal"T Flat or I ugged Max.10-tile stack 6:12 6.1 Boral Roof Underlayments shall be install d in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Secti n 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and heck for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to applic tion,and prime the substrate(if applicable). 63 Boral TileSeal 50"T:or GatoeSeal 6.3.1 Shall be installed in compliance with requir ments for an approved self adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Resid ntial R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's ins allation instructions. When installed over a mechanically attach d,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. MEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certi�rcateofAuthorization#32455 7T"EDITION(202 )FBC NON-HVHZ EVALUATION FL14317-R11 Boral Roof Unc erlayments,(602)269-2288 Revision 12:11/25/2020 Page 5 of 6 0 ONEMOJeM 6.3.2 Multi-Ply Underlavment Systems: One or two plies of Citadel Plus follow d by Boral TileSeal 50"T or GatorSeal is allowable for use under mechanically attached, non-tile prepared oof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is Ilowable if a multi-ply underlayment system is desired. 6'4 BorafTileSeat"'or:, oiLMQafSealHr. 6.4.1 Non-Tile Applications: Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)In FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's in Iallation instructions. When installed over a mechanically attach d,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1 6.4.2 Tile Applications: Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.2 for attachment limiti tions. Refer to Table 4 for the staging limitations. 6.4.3 Multi-Ply Underlavment Systems: One or two plies of Citadel Plus followed by Borol TileSeal"T or Boral MetalSeal"T is allowable for use under mechanically attached, non-tile prepared oof systems. Limits of use are those associated with the top-layer material. This is not a requirement,but is Ilowable if a multi-ply underlayment system is desired. Refer to Section 5.8.2 for use of Citadel Plus as a base ply membrane in underlayment systems for use under tile- roof systems. 3. As required by the Building Official or Au t ority Having Jurisdiction to properly evaluate the installation of this product. an Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and produ tion locations having met codified material standards. UL LLC—QUA9625;(414)248-6409;Karen.buchmann@ul.com -END OF EVALUATION REPORT- MEMO ETC,LLC Evaluation Report M35710.12.10-R12 Certificate of Authorization#32455 V11 EDITION(202 )FBC NON•HVHZ EVALUATION FL14317-RII Boral Roof Un erlayments;(602)269-2288 Revision 12:11/25/2020 Page 6 of 6 RECEIVED APR 2 9 1011 F'rmitting ,3%a �.. etco ty c m 23:14Y NEm'o on#32455 caq r,Va COUNIP-3-P62-9245 ENGINEER EVALUATE TEST 5UGC CONSULT East Coast Metals,Inc. Evaluation Report E10240.01LOS-R5 7905 W.20th Avenue FL5374-R6 Hialeah,FL 33014 Hate of issuance:09/03/2008 (305)885-9991 Ffl e PCslon 5-®py09/2912020 SCOPE: -----.__.. This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition(2020)Florida Building Code sections noted herein. DEsrJtiilioia: TRIMLOCIt and TRIMLOCit PW5 flip&Ridge Anchor LA®Eume: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. COMMUEo COMPUAKE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s)changes, or Code provisions that relate to the product(s) change, Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. AovwisEMI m The Florida Product Approval Number (FL#) preceded by the words 'MEMO{etc. Evaluated" may be displayed In advertising literature'. if any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INsPecrloN:Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared lay: ,�� Robert J.M.Nierninen,P.E. A The facsimileseal appeanngwas authorized by Robert Florida Registration No.59166,Florida OCA ANE1983 Nieminen,P.E.on 09/29/2020.This does notserve as an electronicaliyslgned document CERTIFICATION OF INDEPENDENCE: 1. MEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. MEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products It evaluates. 3. Robert Nleminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product S. This is a building code evaluation. Neither MEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019,NEW ETC,LLC AJ ROoPINe COMPONENT EVALuncim: Product Category: Roofing Sub-Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: TMMLOCIt and TRIMLOCK PWS,as produced by East Coast Metals,have demonstrated compliance with the following sections of the 71 Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the installation Requirements and Limitations /Conditions of Use set forth herein. Section Property Standard Year 1507.3.7 Installation,non-HVHZ FRSA/TRI(09-18) 2018 1518.8.1 installation,HVHZ RAS 118,119&120 2020 1523.6.5.2.2 Static uplift resistance TAS 101 1995 1504.2.1.1 Overturning resistance SBCCI SSTD 11 1997 f Fealty Examinattan Referance Its ERD(TST6049) Static Uplift Resistance E42730.08.13 08/23/2013 ERD CM6049) Static Uplift Resistance ECM SC679S.12.14-1 02/27/2015 ERD(TST6049) Static Uplift Resistance ECM-SC6795.12.14-2 02/27/2025 Florida TEC(TS17393) TAS 101 S10-628R 10/27/2010 NEMO CW6049) Tensile adhesion 41-ECM-20-SSCRT 09/29/2020 PRI(TST5878) TAS 101 ECM-001-02-01 09/21/2001 PRI(TST5878) TAS 201 ECM-003-02-01 06/13/2008 PRI(TST5878) TAS 101 ECM-004.02.01 06/13/2009 PRI(TST5878) TAS 101 ECM-005-02.01 06/13/2008 PRI(TST5878) TAS 101 ECM-006-02-01 06 PRI(TST5878) TAS 101 ECM-007.02-01 008 PRI(TST5878) TAS 101 ECM-008.02-01 06/13/2008 East Coast Metals Metal Quality Mill Certifications Various Intertek/ATI(QUA2844) Quality Control Participation Le 03/11/2015 Intertek/ATI(QUA1844) Quality Control Florida BCIS Current oc 0 4.1 TRIMLOCK; Preformed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof the adhesive. TRIMLOCK is characterized by its profiled and perforated upper horizontal flange designed to receive and �V allow for interlock with the overlying the adhesive. TRIMLOCK Is available in 119-3/8-Inch L 3/8")length by 3,3 , 4,5 or 6-inch L 3/8-inch)heights with IS-Inch(±1/16-inch) deck-flanges. �C) NEMO ETC,!LC Evaluation Report E30240.08.08-115 Cenpate of Authonzatien#32455 7r"EDITION 12020)F8C NON-HVHZ&HVHZ EVAWA110N FL5374-R6 TRIMLOCK and TRIMLOCK PLUS Hip&Ridge Anchor Revision S.09/29/2020 Page 2 of 7