Loading...
HomeMy WebLinkAboutEngineering 1 ENGINEERING 87919 1 44301-4183564815 Page 1/1 Date:April 15th, 2021 ASCE 7 Components & Cladding Wall Pressure Calculator Prepared For: 7030 SW 16TH COURT PEMBROKE PINES FL Project:WALDROP CONDO DOOR REPLACEMENT Project Address: 9600 S.OCEAN DRIVE UNIT 1202 JENSEN BEACH Florida Box for Engineer Seal Only-Original Rqd for Permlt&Use Frank Bennardo,PE FL46549 or Richard Neet,PE FL86488 The following has been considered in determining allowable stress design (ASD)wall opening pressures for the above- referenced location. ASCE:ASCE 7-16(7TH EDN FLORIDA BUILDING CODE, 2020 FBC, NMNRDO( - 20181BC) Wind Velocity: 170 MPH Exposure Category: D ❑ s I, C4) ® s> Kd: 0.85 s Kzt: 1 .� Minimum Building Dimension: 170FT rRr ELEVATION 7R/ EST NDRIL Mean Roof Height: 127FT LEAST HORIZONTAL y.Y DIMENS ON Unit Elevation: 118FT is DIMENSION_ 51 ROOF SLOPE: FLAT(<10D) 4 Ar—IMN Number Of Openings: 1 RODF Shutter: NO WINO HEIGHT FLOW Mark: 1 s4� INVIEW STALL Height Of Opening: 80 IN PLAN COMPLEX 9 p g• COMPLEX Width,Of Opening: 36 IN CORNERS sss BUILDINGS>RO'RDDFHEIGHT Zone:4 SD%OFLE"THORROWALMMENS10NOR40%OFMEANROOFMEKMI I.WMCI "R U LESS • BUT NOT.R%OF LEAST MORIZONTILL DIMENSION OR SFT.•-USE CORNER ZONE 16 AT ALL IN QUESTION. SHUTTER ORION FORCES OUTPUT TO HEIGHT'HEIGHT/S. Based on the above,the following ASD design pressures apply for the opening marks which shall correspond with contractor-supplied building layout: a: 17 FT Mark: 1 Wall Positve Pressure: 60.3PSF Wall Negative Pressure:-60.9PSF Design pressure results are in accordance with the Building&ASCE 7 codes listed above for an ENCLOSED structure only (Gcpi=+-0.18). Results are based on contractor-supplied data and are not field verified by this office. Input shall be verified by others prior to permit&use.Selection of all components&their respective approvals shall be by others and are to be within the ASD design pressure limitations stated herein. Results only valid with original or verifiable digital seal by a licensed PE of this firm. For more information on any of the terms listed herein, or to use a design tool to evaluate your openings,visit EngineeringExpress.com/Wind. Corp.Office:160 SW 12th Avenue Suite 106,Deerfield Beach,Florida 33442 (954)354-0660 I(866)396-9999 Team@EngineeringExpress.com I EngineeringExpress.com