Loading...
HomeMy WebLinkAboutProduct Approval (3) Professional -g F9 BCIS Home Log In ! User Registration i Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map finks ! Search FI rida Product Approval d- ra irm, USER:Public User Product Anoroval Menu>Product or Aoosication Search>@Qolication Ust>Application Detail FL# FL20876-R2 Application Type RevisionREVIEWED A Code version2020 Application Status Approved CODE COMPLIANCE *Approved by DB�,fertilra �'D� sFjell}e*r�w�retified by the POC and/or the Comm i a �,J V B®CC Comments Archived Product Manufacturer Dupont Address/Phone/Email 5401 Jefferson Davis Highway Richmond,VA 23234 (812)212-4429 • melissa.s.grant@dupont.com �� y Authorized Signature Melissa Grant melissa.s.grant@dupont.com Technical Representative Melissa Grant Address/Phone/Email P.O.Box 103 202 E.Washington Street Morris,IL 60450 (812)212-4429 melissa.s.grant@dupont.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Product Evaluation Entity Evaluation Entity Intertek Testing Services NA,Inc. Quality Assurance Entity Intertek Testing Services NA,Inc.-QA Entity Quality Assurance Contract Expiration Date 12/31/2023 Validated By Intertek Testing Services NA,Inc. Certificate of Independence Referenced Standard and Year(of Standard) Standard Year ASTM D226 2009 Equivalence of Product Standards Certified By Sections from the Code OUPOHT! Installation Information Tyvek. DuPontTM Tyvek® ProtecTm Roofing Underlayments Installation Guidelines SYSTEM OVERVIEW Installation Guidelines Acceptable For Use With Tyvek`Protec'meets or exceeds the following code • DuPont'Tyvek•Protec"120 criteria and test protocols: • DuPont'Protec"'160 -AC188(Intertek CCRR-1062) • DuPont'Tyvek*Protec"200 -ASTM D226 types I&II Specifications -ASTM E108 • Tyvek'Protec"is available in 10 square rolls: -CAN/CSA A123.3 48"x25071.2m x 76.2m(92.9m2) -CAN/CSA A220.1 and 2 square rolls:48"x5071.2m x 15.2m(18.5 m2) Precautions and Safety • Tyvek`Protec"is for use on roofs with slopes a2:12. . Apply Tyvek*Protec"taut and wrinkle-free. • Tyvek'Protec"must be covered with the final roof Do not stretch. cladding within: • Do not apply Tyvek'Protec"over wet or frost-covered 3-months with Tyvek`Protec"120 roof sheathing. 6-months with Tyvek*Protec"160 or Tyvek* • Caution should be taken when walking on Tyvek' Protec"200 Protec"until it has been fastened according to Tyvek`Protec"'should not be considered a final roofing instructions. system/primary water barrier.Tyvek"Protec"is a • Caution should be taken when walking on Tyvek' secondary layer applied over sheathing,under a primary Protec"when it is wet or frost-covered. roofing system as specified for the following: • Use fall protection when working on roof.Refer to -Tyvek` Protec'120-asphalt shingles,metal or cedar OSHA safety regulations 29 CFR1926 subpart M. roof cladding • Consult your local DuPont-Tyvek`Specialist for additional information. -Tyvek'Protec"160-asphalt shingles,tile,metal, cedar,or state roof cladding Preparation -Tyvek'Protec"200-asphalt shingles,tile,metal, ° Apply Tyvek'Protec"over a dry,smooth,clean and defect-free roof deck.Tyvek'Protec'"cannot be installed cedar,or slate roof cladding over existing roof cladding. Building Code Compliance • Tyvek'Protec"is a vapor barrier.Ensure that the space • Consult local building code and roof cladding beneath the roof sheathing is properly ventilated before manufacturer for use of underlayment. installing to avoid condensation problems. • Consult local building code and roof cladding manufacturer for underlayment edge and end overlap and fastening requirements that may differ from Tyvek' Protec"instructions.Follow the more restrictive requirements. • Where required by local building code,apply selfadhering waterproof underlayment as required by code according to manufacturer's instructions and Tyvek' Protec"for successive courses. • Tyvek`Protec'provides protection against leaks under all types of roof coverings identified by ICC-ES AC188. tertek Code Compliance Research Report Total Quality.Assured. CCRR-1062 Issue Date:05-25-2016 Revision Date:01-26-2021 Renewal Date:01-31-2022 DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION DupontTM Tyvek• ProtecTM 160 is a mechanically attached Section:07 30 05—Roofing Felt and Underlayment synthetic underlayment comprised of an embossed non- woven top scrim and a woven bottom scrim with a polymeric REPORT HOLDER: laminated facer. The underlayment has an overall weight of DuPont de Nemours,Inc. 3.27 pounds per 100 square feet, and it is available in rolls 1S01 Larkin Center Drive 48 inches wide by 250 feet long. Midland,MI 48674 (989)638-4318 DupontTM Tyvek• ProtecTM 200 is a mechanically attached www.dupont.com/building synthetic underlayment comprised of an embossed non- woven top scrim and a woven bottom scrim with a polymeric REPORT SUBJECT: laminated facer. The underlayment has an overall weight of Dupont' Tyvek° ProtecTM 120, 160, and 200 Roofing 3.58 pounds per 100 square feet, and it is available in rolls Underlayments 48 inches wide by 250 feet long. 1.0 SCOPE OF EVALUATION 4.0 INSTALLATION This Research Report addresses compliance with the following 4.1 General: Codes: 2018,2015,and 2012 International Building Code®(IBC) Installation of the underlayments must comply with the 2018,2015,and 2012 International Residential Code®(IRC) applicable Code, this report, and the report holder's 2020 Florida Building Code(FBC)—See Section 8.1 published installation instructions. 2.0 USES The underlayments must be installed in accordance with the subsections of IBC Section 1507 and IRC Section R905 DupontTM Tyvek° ProtecTM 120, 160, and 200 underlayments applicable to the roof covering being installed. The are used in the field of the roof as an alternative to the ASTM underlayments must be laid with the print side up,with laps as D226, Type I and Type 11, roof underlayments specified in required by the applicable Code, evaluation report, or Chapter 15 of the IBC and Chapter 9 of the IRC. manufacturer's instructions,whichever is more restrictive. The underlayments may be used in areas of the roof required The roof covering may be installed immediately following the by IBC Section 1507 or IRC Section R905 to have an ice barrier underlayment application and the underlayment must be roof underlayment,when installed as noted in Section 4.2. covered within the time designated in the report holder's published installation instructions. The underlayments may be used as components of classified assemblies when installed as described in this report. 4.2 Ice Barrier: The underlayments have been evaluated for the properties as In areas of the roof required by IBC Section 1507 or IRC listed in Table 1. Section R905 to have an ice barrier,two layers of Dupont'"" Tyvek• ProtecTM 120, 160, or 200 underlayment, solidly 3.0 DESCRIPTION cemented together with a low solvent based roofing cement complying with ASTM D4586 Type 1(asbestos free), may be DupontTM Tyvek• ProtecTM 120 is a mechanically attached used provided the ice barrier extends up the roof a minimum synthetic underlayment comprised of an embossed non- distance of 24 inches inside the interior wall line of the woven top scrim and a woven bottom scrim with a polymeric building. The underlayment installed in the field of the roof laminated facer. The underlayment has an overall weight of must overlap the ice barrier. 2.25 pounds per 100 square feet, and it is available in rolls 48 inches wide by 250 feet long. 545 E.Algonquin Road •Arlington Heights a Illinois•60005 ® intertek.com/buildina Intertek PCA-,o, Version:21 December 2017 SFT-CCRR-OP-40b on Code Compliance Research Report CCRR-1062 Page 3 of 3 TABLE 1—PROPERTIES EVALUATED PROPERTY_r IBC SECTION"_ _IRC SECTION" FBC(BUILDING) FBC(RESIDENTIAL) �~104.11,1506,and R104.11,R904,and ! 104.11,1507,and Physical Properties 1 R904 and R905 1507. 4 _ _ R905 1518.4 1 Fire Classification 1505 Iy R902.1 1505 R902 Ice Barrier 1507 _ R905 N/A N/A "Referenced sections apply to 2018 IBC and IRC This Code Compliance Research Report("Report")is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Report.Only the Client is authorized to permit copying or distribution of this Report and then only in its entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. 545 E.Algonquin Road•Arlington Heights•Illinois•60005 O intertek.com/buildinL, Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40b