HomeMy WebLinkAboutAPPROVED 5V Metal Roof1/6/2021 V Ne� (p" ` Florida Building Code Online
Business Professional Regulation
BCIS Home I Log In `,: User Registration I Hot Topics j Submit Surcharge Stats & Facts
Publications Contact Us BCIS Site Map Links Search
dbor*
Product Approval
z. USER: Public User
Product Approval Menu > Product or Application Search > Appl�tion List > Application Detail
FL #
Application Type
Code Version
C20203
Application Status
Comments
Archived
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License
PE-81377
Quality Assurance Entity
Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date
04/22/2024
Validated By
James R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL17022 R8 COI 26ga VMAX plywo .pdf
Standard
Year
TAS 100
1995
TAS 125
2003
UL 580
2006
Sections from the Code
https://www.floridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bd%2buNxXG%2bnlRhGTtoBWMIaQ%3d... 1/3
1 /6/2021
Florida Building Code Online
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Method 1 Option D
10/05/2020
10/12/2020
10/25/2020
12/15/2020
12/16/2020
FL #
C Model, Number or Name
; Description
j 17022.1
j 01: 26ga VMax on Plywood
f 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
i
If
plywood or 3/4" (min) thick wood plank.
�—
Limits of Use
Installation Instructions
i Approved for use in HVHZ: No
FL17022 R8 II 26ga VMAX plywood.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-228
i Evaluation Reports
Other: Refer to evaluation report.
FL17022 R8 AE 26ga VMAX plywood.pdf
j Created by Independent Third Party: Yes
�17022.2
02: 032 Aluminum VMax on Plywood
Nominally 0.032" aluminum (or thicker) VMax 5V panel with
121" coverage on 15/32" (min) plywood or 3/4" (min) thick
I
wood plank.
i Limits of Use
Installation Instructions
i
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R8 II 032 VMAX 21in plywood.pdf
Verified By: David Eng, PE 81377
i Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5
Evaluation Reports
Other: Refer to evaluation report.
FL17022 R8 AE 032 VMAX 21in plywood.pdf
i Created by Independent Third Party: Yes
17022.3 i 03: 26ga VMax on Plywood
j 26ga (min) VMax 5V panel with 24" coverage on 15/32" (min)
plywood or 3/4" (min) thick wood plank. Option for fasteners in
the flats and in the ribs.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R8 II 26ga VMAX plywood flats.pdf
Approved for use outside HVHZ: Yes
I Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
i Design Pressure: +N/A/-114.25
Other: Refer to evaluation report.
Evaluation Reports
FL17022 R8 AE 26ga VMAX plywood flats.pdf
II
R Created by Independent Third Party: Yes
17022.4
04: 26ga CorMax on Plywood
26ga (min) CorMax corrugated panel with 29.5" coverage on
15/32" (min) plywood or 3/4" (min) thick wood plank.
Limits of Use
i Installation Instructions
Approved for use in HVHZ: Yes
I FL17022 R8 II 26ga CorMax Plywood HVHZ.pdf
Approved for use outside HVHZ: Yes
j Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
I Design Pressure: +N/A/-161
i Evaluation Reports
Other: Refer to evaluation report.
FL17022 R8 AE 26ga CorMax Plywood HVHZ.pdf
Created by Independent Third Party: Yes
17022.5 05: 26ga CorMax on Battens
26ga (min) CorMax corrugated panel with 29.5" coverage on
2x4 (min) battens.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R8 II 26ga CorMax Battens.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-161
Other: Refer to evaluation report.
Evaluation Reports
} FL17022 R8 AE 26ga CorMax Battens.pdf
I Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395, *Pursuant to Section 455.275(1),
https://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkU EoR%2bd%2buNxXG%2bnlRhGTtoBWM 1 aQ%3d ... 2/3
Li
EXTREMEMETAL
FABRICATORS
SKILLED CRAFTCRS OFMET4L ROOFING SYSTEMS
0
26ga (min) VMAX over 15/32" (min) plywood
Extreme Metal Fabricators
2120 SW Poma Dr I Palm City FL 34990
Product Description (
5V Crimp style exposed fastener panel with 24" max coverage and nominal
rib height of 3/8".
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
Fastener
#9 or #10 x 1.5" fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.TimberLakeCove.com
.'0 1//'
0
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD A: METHOD B:
#9 AT 16" O.C. #10 AT 16" O.C.
METHOD C:
#10 AT 8" O.C.
X
2
2
3
2\' 1
1
2
f
I4
2
�2
1\ 2
1
2
3
J
�j �- 2
2
g
�f
2/ 1
1
2
3j!
ta— NIP Rf1l1F
I RARI F RC](iF -
a
L
L —{`
,: 101; OF LEAST HOIZONTAL DIMENSION OR 0 dh, WHICHEVER IS SMALLER. BUT NOT
LESS THAN EITHER A°e OF LEAST HORIZONTAL DIMENSION OR 3FT (O.SM).
OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE.
ROOF ,ZONES FOR GENERIC BUILDING
METHOD D:
#10AT6"O.C.
1- —12" (NOM) 12" (NOM)— NR: NOT RATED. CONSULT DESIGN
PROFESSIONAL AS NEEDED
J
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26da 5V_ Crimp on 15/32" plywood
Wind
105
110 120
130 140
150
160
170
180
190 200
Zone 1:
A
A A
A A
A
A
A
A
A A
Zone 2:
A
A A
A A
A
A
A
C
D D
Zone 3:
A
A A
A A
A
B
C
D
D D
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof less than 70, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A A A
Zone 2: A A A A A A A A A B C
Zone 3: A A A A A A AB D D D
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26ga 5V Crimp on 15/32" plywood
N
Wind
105 110
120
130
140
150
160
170 180
190 200_
Zone 1:
A A
A
A
A
A
A
C D
D D
Zone 2:
A A
A
A
C
D
D
D D
D D
Zone 3:
A A
A
C
D
D
D
D D
D
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
FL17022.01: 26cia_5V Crimp on 15/32" plywood
Wind
105 110 120
130
140 150
160
170 180
190 200
Zone 1:
A A A
A
A A
A
B C
D D
Zone 2:
A A A
A
A B
D
D D
D D
Zone 3:
A A A
B
D D
D
D D
D D