HomeMy WebLinkAboutAPPROVED, LAYOUT wetmiller digital shop drawing stamp4 !\, -LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY. ON
f
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp n or less
30- o pan
SpreE der Bar
N.,
•
60 degrees
or less
Tag line of 112 span
Tag line 4*—,4pprox 2/3 to —01
approx.
112 of Span.
REFER TO BCSI
REFER TO BCSI
Truss must be set this way if crane is used.
Truss must be set this way if crane is used.
Truss is an example, your truss may not match.
Truss is an example, your truss may not match.
Insist crane operator sets truss this way.
Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
are installed.
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
�\ WARNING,!,r
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
Hatch Legend
Z_/ZJ/2.50/12 VAULT CLG
CEILING @ 81
— 811
a4 44 BEARING @ 81- 0"
,,,REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
HANGER ID
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
THD26-2
(12) 10d nails
(18) 16d nails
*Please refer to Standard Engineering package for general instuction on Installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1 /2"
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT 8'- 0"
END DETAIL: COFFER
4-01
N.T.S.
12
5r
M
A�Do not stand on trusses until they are braced per BCSI & properly nailed to straps and hangers !!
AsARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 21' - 26' IN LENGTH!!
IV'!ETAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN.
IMPORTANT NOTE
IT IS THE RESPONSIBILITY OF THE PERSON SIGNING
THIS LAYOUT TO FIELD VERIFY THAT THE ROOF
PITCH, HEEL CONDITIONS, OVERHANGS, TRUSS SPANS,
AND OTHER CONDITIONS SHOWN IN THIS LAYOUT
MATCH THE EXISTING STRUCTURE.
TRUSSES WILL BE BUILT PER THE LAYOUT ONLY.
CLOUDED AREAS ARE OF
SPECIAL CONCERN & MUST BE
CHECKED CAREFULLY& MAY
INDICATE DEVIATION FROM
PLANS.
ALL BEAMS BY OTHERS.
VERIFY EXISTING
5/12 ROOF PITCH
--- EXISTING STRUCTURE — — — -- — —
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
CORNDERJACKS
ARE NOT BEVELED.
SEE STANDARD
ENGINEERING.
24" O.C. THRU
CORNER JACKS
ONLY 24" 1111
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-0"
END DETAIL: TYPICAL
M
12
5r
22-0�� N.T.S.
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
etermining successful fabrication of the trusses.
= Y 2. All dimensions in this layout have been verified by the undersigned.
_' 3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
ndersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
o Z J hall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
N o o Ifter 10 days of delivery remedy will be according to Florida statute 558.
or 4. The undersigned acknowledges receipt of "BCSI" summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has
he sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
N' e responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has
o redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
esponsible to Chambers Truss for towing costs due to site conditions.
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour
ee for revisions may be charged by Chambers Truss,
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
nvoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
elivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
easonable attorney's fee for collections in event of payment not timely made. 1-1/2 % per month service charge will be
16° dded for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
eyment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
dersigned agrees to pay such indebtedness including attorney's fees, if default in payment for material be made by the
cipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
IL erein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per (National Standard And Recommended Guidelines On Responsibilities For
onstruction Using Metal Plate Connected Wood Trusses ANSI/TPIIWTCA 4 - 20021t7
12. Warranty is per Chambers Truss Warranty attached.
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT 8'-0"
END DETAIL: TYPICAL
VAULT
2.5 L 4-01
12
00
2-00-00
N.T.S.
SQUARE CUT END
2X4 TOP CHORD 12
WALL HEIGHT 8'-0" 5r
END DETAIL: (A)
4-01
2-00-00
CANTILEVER
5-00-00
N.T.S.
TED
GNED
TITLE
A spreader bar may be required per "BCSI" to prevent injury & damage.
r
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
.-4Q
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
4
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
F� DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
LOADINGIDESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
DESIGN CRITERIA
County
Saint Lucie County
Building Department
Saint Lucie County
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-16
Roofing Material
Metal
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 0
Top Chord Dead
15 4.2 0
Bottom Chord Live
*10-Non Conccurent 0
Bottom Chord Dead
10 3 0
Total Load
55 7.2 0
Duration Factor
1.25 0
Wind Speed
170mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15'
Building Type
Enclosed
Building Category
II: Non Restrictive
Exposure Category
C>Open Terrain with scattered obstructions
Miles from Ocean
5
Conforms to Florida Building Code
2020
R.D.L.=Restraining Dead Load
C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 76929
SCALE: 1 /411 = 1'-011
48 total trusses, 22 unique designs
Designer: BLW Reviewed by:
Date: 08/10/20 Revised 02/15/21
FOR
Doyle Masonry
DESCRIPTION:
WETMILLER / ADDITION
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
76929