HomeMy WebLinkAboutREVIEWED, 2020 CODE- ENERGY CALCEnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 52/16/2021 3:04 PM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
COMPLETE CONSTRUCTION OF THE TREASURE CO
ERIC AND AMY WETMILLER
WETMILLER ADDITION
Street:
City, State, Zip: FORT PIERCE , FL , 34951
4811 TREE TOP TRAIL
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
Addition
Detached
1
No
1034
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.65 82.00 ft²
SHGC=0.25
Sgl, U=0.70 66.67 ft²
SHGC=0.30
N/A f t ²
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1034.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Frame - Wood, Exterior R=19.0 1024.00 ft²
b. N/A R=f t ²
c. N/A R=f t ²
11. Ceiling Types
a. Under Attic (Vented)R=30.0 1034.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Electric Cap: 40 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:1.500 ft.
Area Weighted Average SHGC:0.272
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits None
- Supplemental for addition
(Bedrms In Addition) 1(1)
(148.7 sqft.)
(1024.0 sqft.)
(1034.0 sqft.)
(1034.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
24.0 SEER:16.00
Efficiency
k B t u / h r Efficiency
17.0 COP:1.00
f t ² R
6 140
EF: 0.980
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.144
Total Proposed Modified Loads:
Total Baseline Loads:
31.40
31.49 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). (Exception may apply)
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
2-16-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: ST LUCIE COUNTY
ST LUCIE COUNTY
COMPLETE CONSTRUCTIO
1
ERIC AND AMY WETMILLER
WETMILLER ADDITION
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle:0
No
1
1034
1
Addition
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34951
FORT PIERCE ,
St. Lucie
4811 TREE TOP TRAIL
Street Address
Comment:
Building Type: User
Cross Ventilation:No
Whole House Fan:No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1034 9600
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 CABANA 55 440 No 0 Yes Yes1 Yes
2 TOILET 20 160 No 0 Yes Yes1 Yes
3 M BATH 172 1376 No 0 Yes Yes1 Yes
4 M WIC 1 48 384 No 0 Yes Yes1 Yes
5 M WIC 2 48 384 No 0 Yes Yes1 No
6 MASTER BEDROO 256 2048 No 0 1 Yes Yes1 Yes
7 KITCHEN 92 1104 Yes 0 Yes Yes1 Yes
8 LIVING 240 2880 No 0 Yes Yes1 Yes
9 LAUNDRY 78 624 No 0 0 Yes Yes1 Yes
10 PANTRY 25 200 No 0 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 55 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft CABANA
2 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft TOILET
3 172 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH
4 48 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft M WIC 1
5 48 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2
6 256 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -037 ft MASTER BEDRO
7 92 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft KITCHEN
2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
8 240 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft LIVING
9 78 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft LAUNDRY
10 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Gable or Shed Metal 1120 ft² Light 0.4 0 22.62______No216 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Vented 1034 ft² N N150
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Vented)30 55 ft² 0.1 Wood______CABANA Blown
2 Under Attic (Vented)30 20 ft² 0.1 Wood______TOILET Blown
3 Under Attic (Vented)30 172 ft² 0.1 Wood______M BATH Blown
4 Under Attic (Vented)30 48 ft² 0.1 Wood______M WIC 1 Blown
5 Under Attic (Vented)30 48 ft² 0.1 Wood______M WIC 2 Blown
6 Under Attic (Vented)30 256 ft² 0.1 Wood______MASTER BEDRO Blown
7 Under Attic (Vented)30 92 ft² 0.1 Wood______KITCHEN Blown
8 Under Attic (Vented)30 240 ft² 0.1 Wood______LIVING Blown
9 Under Attic (Vented)30 78 ft² 0.11 Wood______LAUNDRY Blown
10 Under Attic (Vented)30 25 ft² 0.11 Wood______PANTRY Blown
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
1 19 0CABANA0006 8N Frame - Wood 0.40.15Exterior48.0 ft² ____
2 19 0CABANA0006 8S Frame - Wood 0.40.15Exterior48.0 ft² ____
3 19 0CABANA00010 8W Frame - Wood 0.40.15Exterior80.0 ft² ____
4 19 0TOILET0005 8S Frame - Wood 0.40.15Exterior40.0 ft² ____
5 19 0M BATH 0005 8S Frame - Wood 0.40.15Exterior40.0 ft² ____
6 19 0M BATH 0006 8W Frame - Wood 0.40.15Exterior48.0 ft² ____
7 19 0M WIC 1 0008 8S Frame - Wood 0.40.15Exterior64.0 ft² ____
8 19 0MASTER BE 0005 8N Frame - Wood 0.40.15Exterior40.0 ft² ____
9 19 0MASTER BE 00016 8E Frame - Wood 0.40.15Exterior128.0 ft² ____
10 19 0MASTER BE 00016 8S Frame - Wood 0.40.15Exterior128.0 ft² ____
11 19 0KITCHEN0009 12W Frame - Wood 0.40.15Exterior108.0 ft² ____
12 19 0LIVING00015 12E Frame - Wood 0.40.15Exterior180.0 ft² ____
2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
#Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
13 19 0LAUNDRY0006 12W Frame - Wood 0.40.15Exterior72.0 ft² ____
#Door Type U-Value AreaStorms
DOORS
Ornt Space Width
Ft In Ft In
Height
1 Insulated .39 16.7 ft² None______N CABANA 8662
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 S Low-E Single 0.65 0.25 8.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes2 N
2 S Low-E Single 0.65 0.25 8.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes5 N
3 W Low-E Single 0.65 0.25 6.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes6 N
4 E Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N
5 W Low-E Single 0.7 0.3 26.7 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes11 N
6 W Low-E Single 0.7 0.3 40.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes11 N
7 E Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes12 N
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1120 761.45.000413Wholehouse .1341115.36Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtypeBlockSpeed
1 Electric Strip Heat/Supplement COP:1 17 kBtu/hr ______sys#1None1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtypeBlockSubtype
1 Central Unit/Supplemental for a SEER: 16 24 kBtu/hr 720 cfm 0.8______sys#1Split1 Single
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1 Electric 0.98 40 gal 60.9 gal 120 deg None______None Exterior
FSEC
Company Name System Model #Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert #Area Volume
None None f t ² ______
2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Location R-Value Area Location Area
---- Supply -------- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 140 ft² Attic 14 ft² Default Leakage Attic (Default) c______1 1 (Default) c
TEMPERATURES
Programable Thermostat: N Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec
[X] Dec[X] Nov
[X] Nov
[ ] Oct
[X] Oct
[ ] Sep
[ ] Sep
[ ] Aug
[ ] Aug
[ ] Jul
[ ] Jul[ ] Jun
[ ] Jun
[X] Jun
[ ] May
[ ] May
[ ] Apr
[X] Apr
[X] Mar
[X] Mar
[X] Feb
[ ] Feb
[X] Jan
[ ] Jan
Heating
Venting
Thermostat Schedule:HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)AM
PM
78
80
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Heating (WD)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)AM
PM
65
68
65
68
65
68
65
68
65
68
65
68
65
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 CABANA
Default(8 lbs/sq.ft.f t ² f t 0.3 TOILET
Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1
Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2
Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO
Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN
Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 LAUNDRY
Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 PANTRY
2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
���������������������������������������������������������������������������
���������������������������������������������������������������������������������
�����������������������������������������������������