Loading...
HomeMy WebLinkAboutREVIEWED, 2020 CODE- ENERGY CALCEnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 52/16/2021 3:04 PM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY COMPLETE CONSTRUCTION OF THE TREASURE CO ERIC AND AMY WETMILLER WETMILLER ADDITION Street: City, State, Zip: FORT PIERCE , FL , 34951 4811 TREE TOP TRAIL Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) Addition Detached 1 No 1034 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.65 82.00 ft² SHGC=0.25 Sgl, U=0.70 66.67 ft² SHGC=0.30 N/A f t ² 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1034.00 ft² R=f t ² R=f t ² 10. Wall Types a. Frame - Wood, Exterior R=19.0 1024.00 ft² b. N/A R=f t ² c. N/A R=f t ² 11. Ceiling Types a. Under Attic (Vented)R=30.0 1034.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 40 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.500 ft. Area Weighted Average SHGC:0.272 Description Area Insulation Area Insulation Area Insulation Area 16. Credits None - Supplemental for addition (Bedrms In Addition) 1(1) (148.7 sqft.) (1024.0 sqft.) (1034.0 sqft.) (1034.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 24.0 SEER:16.00 Efficiency k B t u / h r Efficiency 17.0 COP:1.00 f t ² R 6 140 EF: 0.980 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.144 Total Proposed Modified Loads: Total Baseline Loads: 31.40 31.49 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). (Exception may apply) FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 2-16-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY COMPLETE CONSTRUCTIO 1 ERIC AND AMY WETMILLER WETMILLER ADDITION Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 1 1034 1 Addition Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34951 FORT PIERCE , St. Lucie 4811 TREE TOP TRAIL Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1034 9600 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 CABANA 55 440 No 0 Yes Yes1 Yes 2 TOILET 20 160 No 0 Yes Yes1 Yes 3 M BATH 172 1376 No 0 Yes Yes1 Yes 4 M WIC 1 48 384 No 0 Yes Yes1 Yes 5 M WIC 2 48 384 No 0 Yes Yes1 No 6 MASTER BEDROO 256 2048 No 0 1 Yes Yes1 Yes 7 KITCHEN 92 1104 Yes 0 Yes Yes1 Yes 8 LIVING 240 2880 No 0 Yes Yes1 Yes 9 LAUNDRY 78 624 No 0 0 Yes Yes1 Yes 10 PANTRY 25 200 No 0 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 55 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -022 ft CABANA 2 20 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -05 ft TOILET 3 172 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -011 ft M BATH 4 48 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -08 ft M WIC 1 5 48 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft M WIC 2 6 256 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -037 ft MASTER BEDRO 7 92 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft KITCHEN 2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 8 240 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -015 ft LIVING 9 78 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -06 ft LAUNDRY 10 25 ft² 1 0 0______ Slab-On-Grade Edge Insulation - - - -01 ft PANTRY # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or Shed Metal 1120 ft² Light 0.4 0 22.62______No216 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Vented 1034 ft² N N150 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Vented)30 55 ft² 0.1 Wood______CABANA Blown 2 Under Attic (Vented)30 20 ft² 0.1 Wood______TOILET Blown 3 Under Attic (Vented)30 172 ft² 0.1 Wood______M BATH Blown 4 Under Attic (Vented)30 48 ft² 0.1 Wood______M WIC 1 Blown 5 Under Attic (Vented)30 48 ft² 0.1 Wood______M WIC 2 Blown 6 Under Attic (Vented)30 256 ft² 0.1 Wood______MASTER BEDRO Blown 7 Under Attic (Vented)30 92 ft² 0.1 Wood______KITCHEN Blown 8 Under Attic (Vented)30 240 ft² 0.1 Wood______LIVING Blown 9 Under Attic (Vented)30 78 ft² 0.11 Wood______LAUNDRY Blown 10 Under Attic (Vented)30 25 ft² 0.11 Wood______PANTRY Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 19 0CABANA0006 8N Frame - Wood 0.40.15Exterior48.0 ft² ____ 2 19 0CABANA0006 8S Frame - Wood 0.40.15Exterior48.0 ft² ____ 3 19 0CABANA00010 8W Frame - Wood 0.40.15Exterior80.0 ft² ____ 4 19 0TOILET0005 8S Frame - Wood 0.40.15Exterior40.0 ft² ____ 5 19 0M BATH 0005 8S Frame - Wood 0.40.15Exterior40.0 ft² ____ 6 19 0M BATH 0006 8W Frame - Wood 0.40.15Exterior48.0 ft² ____ 7 19 0M WIC 1 0008 8S Frame - Wood 0.40.15Exterior64.0 ft² ____ 8 19 0MASTER BE 0005 8N Frame - Wood 0.40.15Exterior40.0 ft² ____ 9 19 0MASTER BE 00016 8E Frame - Wood 0.40.15Exterior128.0 ft² ____ 10 19 0MASTER BE 00016 8S Frame - Wood 0.40.15Exterior128.0 ft² ____ 11 19 0KITCHEN0009 12W Frame - Wood 0.40.15Exterior108.0 ft² ____ 12 19 0LIVING00015 12E Frame - Wood 0.40.15Exterior180.0 ft² ____ 2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 13 19 0LAUNDRY0006 12W Frame - Wood 0.40.15Exterior72.0 ft² ____ #Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1 Insulated .39 16.7 ft² None______N CABANA 8662 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 S Low-E Single 0.65 0.25 8.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes2 N 2 S Low-E Single 0.65 0.25 8.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes5 N 3 W Low-E Single 0.65 0.25 6.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes6 N 4 E Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes9 N 5 W Low-E Single 0.7 0.3 26.7 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes11 N 6 W Low-E Single 0.7 0.3 40.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes11 N 7 E Low-E Single 0.65 0.25 30.0 ft² 1 ft 6 in 1 ft 4 in NoneMetal None______Yes12 N Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1120 761.45.000413Wholehouse .1341115.36Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/Supplement COP:1 17 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/Supplemental for a SEER: 16 24 kBtu/hr 720 cfm 0.8______sys#1Split1 Single # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.98 40 gal 60.9 gal 120 deg None______None Exterior FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ 2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 140 ft² Attic 14 ft² Default Leakage Attic (Default) c______1 1 (Default) c TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 CABANA Default(8 lbs/sq.ft.f t ² f t 0.3 TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 1 Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC 2 Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN Default(8 lbs/sq.ft.f t ² f t 0.3 LIVING Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 LAUNDRY Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 PANTRY 2/16/2021 3:04 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ��������������������������������������������������������������������������� ��������������������������������������������������������������������������������� �����������������������������������������������������