HomeMy WebLinkAboutREVIEWED, design pressure calcsPARAD SE EXTER ORS "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: WILLIAM & BETH CASEY Address: 5901 SILVER OAK DR FORT PIERCE , FL 34982 Wind Zone: 170 MPH. Exposure Category: C lvtininwm Building Dimension: 36 ft. Mean Roof Height: 20 It, Risk Category: II Opening Numhet ' I oc. rtion Zone Device Width(ill) I lilt 35 2 lilt 35 3 lilt 51 4 lot 35 5 Int 35 6 lilt 35 7 Int 25 8 lilt _ 25 9 lilt 35 10 Int 35 11 Iut 35 12 Int 35 13 Int 35 14 Int 35 15 Int 35 16 Int 35 Pressure Calculations Device � Device Max Positive Max NeIL gative Height (in) j Elevation (ft) Presswe (pst) Pressure (Psf) 17 7 40.2 -43.6 61 7 39.1 -42.5 37 7 39A -42.9 36 7 40.2 43.6 61 7 39.1 42.5 61 7 39.1- -42.5 61 7 40.0 -43.4 61 7 40.0 43.4 61 7 39A -42.5 61 7 39.1 -42.5 17 7 40.2 43.6 61 7 39.1 -42.5 17 7 40.2 -43.6 61 7 39.1 -42.5 17 7 40.2 -43.6 60 7 39.2 -42.6 Prepared in nmor dance rvlth. :ISLE 7-/6. Ch tiler 30. IPind Lnads - Coniyonenrs and C(addlny. Ith Cdirinn f202t1) Flaidn Uu((dOg Code. Page l of 1