Loading...
HomeMy WebLinkAboutAPPROVED OC Shingles FL10674-R16 - 6406 Fort Pierce BlvdFlorida Building Code Online httpsa/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG... I , BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map f Links f Search f db' _ _ Y { i�;f Product Approval I"°' USER: Public User Product Apirroval.Muu > PEW.uCt 4f_f_4ARIlSat .n�gDSh. > ApRIig-a11prdjst > Application Detail OFNCE OF SECRETARY FL # FL10674-1116 Application Type Revision Code Version 2020 Application Status Pending FBC Approval Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.ke42ler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419)376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 01/01/2099 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL10674_R16_COI_2020_01_QI_NIEMINEN.�f Standard ASTM D1970 ASTM D3161 ASTM D3462 ASTM D7158 Year 2015 2016 2010 2019 1 of 2 1/22/2021, 11:02 AM Florida Building Code Online https://www.floridabuilding. org/pr/pr_app_dtLaspx7param=wG... Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Method 1 Option D 12/11/2020 12/17/2020 12/26/2020 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, laminated, starter and hip & ridge shingles Shingles and Starters Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674_R16_II_2020_12_11_FINAL ER_OC_ASPHALT Approved for use outside HVHZ: Yes SHINGLE$_FL10674-R16,pdf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 69166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 6. Evaluation Reports FL10674 R16 AE_202??�12_ll_FINAL_ERQ_ASPHALT SH ING LES_FL10674-R16. {ZQf Created by Independent Third Party: Yes Badr Next COMack Us :: 2601 elak Stone 89atl Talbhassee FL 32399 Phone: 680-48]-1824 The State of Fbrda N an AglEEO empbyer. spy' h[ 200J-2013 S[ t f Fbiid :: piNyry Statement :: ccesslblldy Statement :: ftefuntl Statement Under Fbritla kw, emaY addresses are pubik resorts. ]f you tlo no[ want your a -mail address released in response [9 a Oubik-recortls request, do noF sentl ekRronk mall to this en[Ry. Ins[eatl, contact the oR a by phone or by tmdRbnal mail, If you have any ques[bns, please contact 850.48J.1396. *Pursuant to Sec[bn 45a.2]6(I), Fbrida Statutes, eRective October 1, 20 [he nsetl antler Chapter Ikensee. However er can be matle aval6bk to the pubik. To tletennlne pyr Protluct Approval Adepts: securityntr rRtcs• '. a personal atltlress, please prop ter 455, F.S., please clkk fLeLe . 2 of 2 1/22/2021, 11:02 AM NEMO l etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION• Owens Corning Evaluation Report 037940.02.12-R11 One Owens Corning Parkway FL10674-1116 Toledo, OH 43659 Date of Issuance: 02/06/2012 (740) 404-7829 Revision 11: 12/11/2020 SCOPE: This Evaluation Report Is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 7t1 Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official, This Evaluation Report consists of pages 1 through 10. Prepared by:3,;` • tpO¢'�CgM1F� •L! 1 Y_!,6l 'a4•'E'.'r Un-• was au y "•�p�4 p,� : * `; ..av The facsimile sealappearing authorized Robert Robert J.M.Nieminen,P.E. ';k• a�`:�,-'.-• ,S,ry N` Nleminen,P.E.on ddoc men. This does not serve as an Florida Registration No, 59166, Florida DCA ANE3983 ";a� , electronically signed document. CERTIFICATION OF INDEPENDENCE: 1, NEMO ETC, LLC does not have, nor does it intend to acquire or will It acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. @2018 NEMO ETC, LLC 4NEM01etc. ROOFING SYSTEMS EVALUATION: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Progertv Standard Year 1507.2.4, R905.2.3 Physical Properties ASTM D1970 2015 1507,2,51 R905.2.4 Material standard ASTM D3462 2010 1507.2.7.10 11905.2.6A Wind Resistance ASTM D3161 2016 1507.2.7.11 R905.2.6.1 Wind Resistance ASTM D7158 2019 Entitv Examination Reference Date Owens Corning Declaration Equivalency Declaration 08/06/2019 PRI(TST5878) ASTM D1970 OCF-382-02-01 10/24/2017 UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 31CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC(TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 PRI (QUA9110) Quality Control Service Confirmation 04/05/2020 PRI (QUA9110) Quality Control Florida BCIS Current TABLE 1: ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Description Standard Starter Strip Shingle H-TX, OR Starter Strip Plus MN, OR Accessory ASTM D3462 starter strips for asphalt roof shingles SRS TopShield Starter MN, OR Starter Strips Starter Shingle Roll NH ASTM D1970 mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter Supreme' GA, CA, CO, I -TX, NJ, OH, ASTM D3462 fiberglass reinforced 3-tab asphalt TN, OR, IL roof shingles Berkshire' MN ASTM D3462 fiberglass reinforced, 4-tab asphalt roof shingles Duration Premium CA, OR Duration' Premium COOL CA Asphalt TruDefinitioe Duration Shingles IN, CA, CO, I -TX, FL, NJ, OH, TruDefinitioe Duration MN, OR, GA, IL, TN fiberglass reinforced, laminated Designer Color Collection ASTM D3462 asphalt roof shingles Oakridge GA, IN, CA, CO, H-TX, I -TX, FL, NJ OH, TN TruDefinitioe Oakridge` H-TX, I -TX WeatherGuard* HP TN NEMO ETC, LLC Evaluation Report 037940.02.12-1131 certlPcate of Authorization N32455 7a' EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 2 of 10 �4NEMO I etc. TABLE I: ASPHALT SHINGLE COMPONENTS Type Product Plant(s) Material Description Standard Berkshire' Hip and Ridge Shingles with Sealant MN DuraRidge® Hip and Ridge MN Hip and fiberglass reinforced, hip and ridge Ridge Shingles with Sealant ASTM D3462 asphalt roof shingles Shingles ProEdge® GA, CA, OH, OR WeatherGuard' HP Hip and Ridge Shingles TN 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (Le.. Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5A This Evaluation Report does not Include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic Insulation. 5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 supreme' ASTM D3161(F) & ASTM D7158(H) Berkshire' Duration Premium Duration Premium COOL TruDefinition' Duration' TruDefinition' Duration Designer Color Collection Oakridge' TruDefinition Oakridge' WeatherGuard' HP 5.5.1 Classification by ASTM D7158: ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. NEMO ETC, LLC Evaluation Report 037940.02.12-RSI Certnmte ojAuthorizatlon #32455 7'"EDITION (2020)FBC NON-HVHZ EVALUATION FL10674-R36 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 3 of 10 NEMO I etc. TABLE2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP St RIDGE Type Product FBC Table 1507.2.7.1 or R905.2,6.1 Starter Strips Starter Strip Shingle ASTM D3161, Class F Starter Strip Plus SRS TopShield Starter Hip & Ridge Shingles Berkshire' Hip and Ridge Shingles with Sealant ASTM D3161, Class F DuraRidgeas Hip and Ridge Shingles with Sealant ProEdge® WeatherGuard' HP Hip and Ridge Shingles 5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations. 5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3. 1507.2.4 or R905.2.3. 6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the limitations set forth in FBC Section 1511 or R908 and published Installation instructions. 6.2 ACCESSORY STARTERS: 6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens Corning current published instructions, using minimum five (5) nails per strip. Felt undedeymsnt Dock Sah-adhered Mathed.ock" undadaYmenf Drlp.—, Drip edge edge Nails located 2"4" from save Install first Self-sealing adhesive Starter Strip positioned along save shingle with ,. 6'rsmoved Starter$* shingle overhangs eaves and rakes'/V 4W Figure 1: Minimum Nailing, Starter Strip Figure 2: Minimum Nailing, Starter Strip Plus NEMO ETC, LLC Evaluation Report 037940.02.12-R31 CertlJ<cate ofAuthprizptlan g32AS5 7TM EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R36 Owens Corning Asphalt Roof shingles Revision 11: 12/11/2020 Page 4 of 10 6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions. _- <> —Deck Ddp edge Selfsealing adhesive positioned along eaves Figure 3: Starter Shingle Roll Stader Shingle Roll adhered directly to underlaymenl and primed drip edge 6.3 ASPHALT SHINGLES: 6.3.1 -Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle. Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required Refer to Owens Corning published information on wind resistance and installation limitations. 6.3.1.1 Supreme: Normal MensarA or Area pars Wintl Areas High VYntl desvenos y AYea pare Viento9 normalea Arees vientav /uertes 2 ' IN 5'Expmure Expasfef6n Figure 4: Minimum Nailing, Supreme (Standard Size) Normal Mansard or Arse pare Wind Areas High Wind daavanes y Area pare Vientos normefes Arees v(enios /aeries (AI t" r10 2N (Bt 2P IN iz i2I 6 6/a` Exposure Exposlol6n Figure 5: Minimum Nailing, Supreme (Metric Size) NEMO ETC, LLC Evaluation Report 037940.02.12-R31 Cert(cate ofAutharization a32455 7'"EDITION (2020)FBC NON-HVHZ EVALUATION FL10674R16 Owens Corning Asphalt Roof Shingles Revlsfon 11: 12/11/2020 Page 5 of 10 6.3.1.2 Berkshire®: seahnt scrip La lira de sellador 8Yz" 9Y3' 9lY' 9Yt' Figure 6: S-Nail Pattern, Berkshire � NEMo I etc. Sealant atrlp La lira de sellador Figure 7; fi-Nail Pattern, Berkshire Seahnl strip La Ifra de sellarbr • •� t—�• BYt' 8Yf 8Yt' r 21. Asplinkroofingcemenf Cemento de toahodo asfatta Figure 8: Mansard or Steep Slope Pattern, Berkshire NEMO ETC, LLC Evaluation Report 037940.02.12-R31 CertlProfe ofAuthorizotion N32455 7r" EDITION )2020) FBC NON-HVHZ EVALUATION FL10674-RI6 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 6 of 10 ONEMOjetc. 6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition Duration Designer Color Collection: 4-Nail Fastening Pattern SurcNail®festeMng area wltlth r Nall, Typical 1 12" Figure 9: Standard 4-Nail Pattern, Duration Flgure 10: 6-Nail Pattern, Duration Greater Than 21:12 sareNall®raatanm9 area width r-Nall, Typical 2^ Pour 1"Spob Figure 11: Mansard or Steep Slope Pattern, Duration NEMO ETC, LLC Evaluation Report 037940.02.12-R31 Certncate o/Autharizat/an k32455 7'a EDITION (20201 FBC NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 7 of 10 4 Nail Pettenl Esquema coil4 clavos r r It— 12` —>I I r 12' —>I 65/e"Fkposure Nails 56/8"Exposule� Exposid6n de 6618pulg. Clams Exposictdn de 6619pulg. Figure 12: Standard 4-Nail Pattern, Oakridge 6.3.1.5 WeatherGuard® HP: '4NEM0 I etc. 6 Nall Pattern Esquema con 6 clavos r r I� rC i•- 124 66/8"Fxpasme Credos 66/6"Exposurea Erposict6u de 5618putg. Expesid6a de 66/8pufg. Figure 13: 6-Nail Pattern, Oakridge Fastening for Slopes Greater Than 21:12 r SureNaIM fastening area width 1 Nall, Typical r' I r 12" V� Four 1" apom of AapM1all Roognp Cement Figure 14: Mansard or Steep -Slope Pattern, Oakridge 6 Nat Pattern Fsquema eon 6 clavos Nail 6t11e from bottom ofShia a 6 118 pping. de at 5 618" Exposure 6 Fasteners parle inferior de la too Exposicidn de 5 518 pulg. 6 sujetedores 12" 1 1• 12 p1g—;21 NA atod E1p4g*n�Ee 5 64 pulg &podel6n m85 518 pilg. Figure 15: 6-Nail Pattern, WeatherGuard HP Fgur 1" Spots of Asphah Roof Cement Cuatro punros de cemmto da perhp de as/dfa de 1 pulgada Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP NEMO ETC, LLC Evaluation Report 037940.02.12-R31 Certlrate oJAuthorization g32455 7'"EDITION (202o) FBC NON-HVH2 EVALUATION FL10674-Riff Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 8 of 10 ONEMOjetc. 6.4 HIP AND RIDGE SHINGLES: 6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions. ➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require minimum two (2) nails per shingle. ➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations. 6.4.1.1 Berkshire®Hip and Ridee with Sealant and DuraRidge®HID and Ridge Shingles with Sealant: Fig. A Prevailing Wind Direction Direction del viento predominante 6Faposure--ffll idindsBpWtl II P Figure 17: Isometric View, Berkshire and DuraRidge WeatherGuard® HP Hip and Ridee Shingles: Fig. A q 4 PrewllIngwlnd Direction p p Hells �i A p I p p I I Expos�u=`I f Fig• B Top View Vista superior 1" 1"IH 2" Nail 2s/a" Claw • Owens Coming suretyal' I I I. �I d I I I 1< 1211 Figure 18: Plan View, Berkshire and DuraRidge Fig. C Hip &Ridge Shingle Fastening TopVievr NeL ls Nails T' , a' kxpoaure i2" Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20: Plan View, WeatherGuard HP Hip and Ridge NEMO ETC, LLC Evaluation Report 037940.02.12-R31 certificote o(Autnori:atisn a32455 7TM EDITION 120201 F6C NON-HVHZ EVALUATION FL10674-R16 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 9 of 10 6.4.1.3 ProEdge®: Prevailing Wind Direction Sealant Strip �~ 0' Exposure Fairies 711� Cover Exposed Fasteners with Roof Cement Figure 21: Isometric View, ProEdge Standard-11•� Fa stoning Pattern 12' Sealant 7'h° S" Exposure Is12"� Figure 22: Plan View, ProEdge As required by the Building Official or Authority Having Jurisdiction to properly evaluate the Installation of this product. Contact the named QA entityfor manufacturing facilities covered by F.A.C. Rule 61G20-3 CW requirements. Refer to Section 4 herein for products and production locations having met codified material standards. PRI Construction Materials Technologies, LLC—QUA9110; 813 621-6777; bwilson@Dricmt.com END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 037940.02.12-R31 Certnmte aJAuthorizarlon H32Q55 7'u EDITION (2020) FBC NON-HVH2 EVALUATION FL30674R36 Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020 Page 10 of 10