HomeMy WebLinkAboutAPPROVED OC Shingles FL10674-R16 - 6406 Fort Pierce BlvdFlorida Building Code Online httpsa/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wG...
I ,
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map f Links f Search f
db'
_ _
Y { i�;f Product Approval
I"°' USER: Public User
Product Apirroval.Muu > PEW.uCt 4f_f_4ARIlSat .n�gDSh. > ApRIig-a11prdjst > Application Detail
OFNCE OF
SECRETARY
FL # FL10674-1116
Application Type Revision
Code Version 2020
Application Status Pending FBC Approval
Comments
Archived
Product Manufacturer Owens Corning
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Authorized Signature Greg Keeler
greg.ke42ler@owenscorning.com
Technical Representative Mel Sancrant
Address/Phone/Email 1 Owens Corning PKWY
Toledo, OH 43659
(419)376-8360
mel.sancrant@owenscornig.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Asphalt Shingles
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J.M. Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 01/01/2099
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL10674_R16_COI_2020_01_QI_NIEMINEN.�f
Standard
ASTM D1970
ASTM D3161
ASTM D3462
ASTM D7158
Year
2015
2016
2010
2019
1 of 2 1/22/2021, 11:02 AM
Florida Building Code Online
https://www.floridabuilding. org/pr/pr_app_dtLaspx7param=wG...
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Method 1 Option D
12/11/2020
12/17/2020
12/26/2020
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, laminated, starter and hip & ridge
shingles
Shingles and Starters
Limits of Use
Installation Instructions
Approved for use
in HVHZ: No
FL10674_R16_II_2020_12_11_FINAL ER_OC_ASPHALT
Approved for use
outside HVHZ: Yes
SHINGLE$_FL10674-R16,pdf
Impact Resistant:
N/A
Verified By: Robert J. M. Nieminen PE - 69166
Design Pressure:
N/A
Created by Independent Third Party: Yes
Other: Refer to ER,
Section 6.
Evaluation Reports
FL10674 R16 AE_202??�12_ll_FINAL_ERQ_ASPHALT
SH ING LES_FL10674-R16. {ZQf
Created by Independent Third Party: Yes
Badr Next
COMack Us :: 2601 elak Stone 89atl Talbhassee FL 32399 Phone: 680-48]-1824
The State of Fbrda N an AglEEO empbyer. spy' h[ 200J-2013 S[ t f Fbiid :: piNyry Statement :: ccesslblldy Statement :: ftefuntl Statement
Under Fbritla kw, emaY addresses are pubik resorts. ]f you tlo no[ want your a -mail address released in response [9 a Oubik-recortls request, do noF sentl ekRronk mall to
this en[Ry. Ins[eatl, contact the oR a by phone or by tmdRbnal mail, If you have any ques[bns, please contact 850.48J.1396. *Pursuant to Sec[bn 45a.2]6(I), Fbrida
Statutes, eRective October 1, 20
[he
nsetl antler Chapter
Ikensee. However er
can be matle aval6bk to the pubik. To tletennlne pyr
Protluct Approval Adepts:
securityntr rRtcs• '.
a personal atltlress, please prop
ter 455, F.S., please clkk fLeLe .
2 of 2 1/22/2021, 11:02 AM
NEMO l etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION•
Owens Corning Evaluation Report 037940.02.12-R11
One Owens Corning Parkway FL10674-1116
Toledo, OH 43659 Date of Issuance: 02/06/2012
(740) 404-7829 Revision 11: 12/11/2020
SCOPE:
This Evaluation Report Is Issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7t1 Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.2.7.1 / R905.2.6.1
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official,
This Evaluation Report consists of pages 1 through 10.
Prepared by:3,;`
• tpO¢'�CgM1F� •L! 1
Y_!,6l 'a4•'E'.'r Un-• was au y "•�p�4 p,� : * `; ..av The facsimile sealappearing authorized Robert
Robert J.M.Nieminen,P.E. ';k• a�`:�,-'.-•
,S,ry N` Nleminen,P.E.on ddoc men. This does not serve as an
Florida Registration No, 59166, Florida DCA ANE3983 ";a� , electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1, NEMO ETC, LLC does not have, nor does it intend to acquire or will It acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial Interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nleminen, P.E. does not have, nor will acquire, a financial Interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
@2018 NEMO ETC, LLC
4NEM01etc.
ROOFING SYSTEMS EVALUATION:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have
demonstrated compliance with the following sections of the 71h Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
Section
Progertv
Standard
Year
1507.2.4,
R905.2.3
Physical Properties
ASTM
D1970
2015
1507,2,51
R905.2.4
Material standard
ASTM
D3462
2010
1507.2.7.10
11905.2.6A
Wind Resistance
ASTM
D3161
2016
1507.2.7.11
R905.2.6.1
Wind Resistance
ASTM
D7158
2019
Entitv
Examination
Reference
Date
Owens Corning
Declaration
Equivalency Declaration
08/06/2019
PRI(TST5878)
ASTM D1970
OCF-382-02-01
10/24/2017
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
31CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC(TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
PRI (QUA9110)
Quality Control
Service Confirmation
04/05/2020
PRI (QUA9110)
Quality Control
Florida BCIS
Current
TABLE 1: ASPHALT SHINGLE COMPONENTS
Type
Product
Plant(s)
Material
Description
Standard
Starter Strip Shingle
H-TX, OR
Starter Strip Plus
MN, OR
Accessory
ASTM D3462
starter strips for asphalt roof shingles
SRS TopShield Starter
MN, OR
Starter
Strips
Starter Shingle Roll
NH
ASTM D1970
mineral -surfaced, fiberglass -reinforced,
self -adhering SBS modified bitumen starter
Supreme'
GA, CA, CO, I -TX, NJ, OH,
ASTM D3462
fiberglass reinforced 3-tab asphalt
TN, OR, IL
roof shingles
Berkshire'
MN
ASTM D3462
fiberglass reinforced, 4-tab asphalt
roof shingles
Duration Premium
CA, OR
Duration' Premium COOL
CA
Asphalt
TruDefinitioe Duration
Shingles
IN, CA, CO, I -TX, FL, NJ, OH,
TruDefinitioe Duration
MN, OR, GA, IL, TN
fiberglass reinforced, laminated
Designer Color Collection
ASTM D3462
asphalt roof shingles
Oakridge
GA, IN, CA, CO, H-TX, I -TX,
FL, NJ OH, TN
TruDefinitioe Oakridge`
H-TX, I -TX
WeatherGuard* HP
TN
NEMO ETC, LLC Evaluation Report 037940.02.12-1131
certlPcate of Authorization N32455 7a' EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 2 of 10
�4NEMO I etc.
TABLE I: ASPHALT SHINGLE COMPONENTS
Type
Product
Plant(s)
Material
Description
Standard
Berkshire' Hip and Ridge
Shingles with Sealant
MN
DuraRidge® Hip and Ridge
MN
Hip and
fiberglass reinforced, hip and ridge
Ridge
Shingles with Sealant
ASTM D3462
asphalt roof shingles
Shingles
ProEdge®
GA, CA, OH, OR
WeatherGuard' HP Hip and
Ridge Shingles
TN
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (Le.. Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be In
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5A This Evaluation Report does not Include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic Insulation.
5_5 Wind Classification: Refer to Section 6 for installation requirements to meet wind classifications
TABLE 2A: WIND CLASSIFICATIONS, ASPHALT SHINGLES
Product
FBC Table 1507.2.7.1 or R905.2.6.1
supreme'
ASTM D3161(F) & ASTM D7158(H)
Berkshire'
Duration Premium
Duration Premium COOL
TruDefinition' Duration'
TruDefinition' Duration Designer Color Collection
Oakridge'
TruDefinition Oakridge'
WeatherGuard' HP
5.5.1 Classification by ASTM D7158:
ASTM D7158, Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations
by a qualified design professional are required for conditions outside these limitations. Contact the shingle
manufacturer for data specific to each shingle.
NEMO ETC, LLC Evaluation Report 037940.02.12-RSI
Certnmte ojAuthorizatlon #32455 7'"EDITION (2020)FBC NON-HVHZ EVALUATION FL10674-R36
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 3 of 10
NEMO I etc.
TABLE2B: WIND CLASSIFICATIONS, STARTER STRIPS AND HIP St RIDGE
Type
Product
FBC Table 1507.2.7.1 or R905.2,6.1
Starter Strips
Starter Strip Shingle
ASTM D3161, Class F
Starter Strip Plus
SRS TopShield Starter
Hip & Ridge
Shingles
Berkshire' Hip and Ridge Shingles with Sealant
ASTM D3161, Class F
DuraRidgeas Hip and Ridge Shingles with Sealant
ProEdge®
WeatherGuard' HP Hip and Ridge Shingles
5.5.2 Refer to Owens Corning published information on wind resistance and installation limitations.
5.6 All components in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3.
Refer to the Product Approval of the component manufacturer for components that are produced by a Product
Manufacturer other than the report holder on Page 1 of this Evaluation Report.
6.1 GENERAL:
6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle
manufacturer's minimum requirements.
6.1.2 Underlayment shall be acceptable to the shingle manufacturer and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3. 1507.2.4 or R905.2.3.
6.1.3 Fasteners shall be in accordance with the shingle manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.1.4 Owens Corning asphalt shingles are acceptable for use in reroof (tear -off) or recover applications, subject to the
limitations set forth in FBC Section 1511 or R908 and published Installation instructions.
6.2 ACCESSORY STARTERS:
6.2.1 Installation of Starter Strip Shingle, Starter Strip Plus and SRS TopShield Starter shall comply with the Owens
Corning current published instructions, using minimum five (5) nails per strip.
Felt
undedeymsnt Dock
Sah-adhered
Mathed.ock"
undadaYmenf
Drlp.—,
Drip edge
edge
Nails located
2"4" from save
Install first
Self-sealing adhesive
Starter Strip
positioned along save
shingle with
,.
6'rsmoved
Starter$* shingle overhangs eaves and rakes'/V 4W
Figure 1: Minimum Nailing, Starter Strip
Figure 2: Minimum Nailing, Starter Strip Plus
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
CertlJ<cate ofAuthprizptlan g32AS5 7TM EDITION (2020) FBC NON-HVHZ EVALUATION FL10674-R36
Owens Corning Asphalt Roof shingles Revision 11: 12/11/2020
Page 4 of 10
6.2.2 Installation of Starter Shingle Roll shall comply with the Owens Corning current published instructions.
_- <> —Deck
Ddp edge
Selfsealing adhesive
positioned along eaves
Figure 3: Starter Shingle Roll
Stader Shingle Roll adhered
directly to underlaymenl and
primed drip edge
6.3 ASPHALT SHINGLES:
6.3.1 -Installation of asphalt shingles shall comply with the Owens Corning current published instructions, using
minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions:
➢ Berkshire' shingles require minimum five (5) nails per shingle.
➢ WeatherGuard' HP shingles require minimum six (6) nails per shingle.
Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required
Refer to Owens Corning published information on wind resistance and installation limitations.
6.3.1.1 Supreme:
Normal MensarA or Area pars
Wintl Areas High VYntl desvenos y
AYea pare Viento9 normalea Arees vientav /uertes
2
' IN
5'Expmure
Expasfef6n
Figure 4: Minimum Nailing, Supreme
(Standard Size)
Normal Mansard or Arse pare
Wind Areas High Wind daavanes y
Area pare Vientos normefes Arees v(enios /aeries
(AI t" r10 2N (Bt 2P IN
iz i2I
6 6/a` Exposure
Exposlol6n
Figure 5: Minimum Nailing, Supreme
(Metric Size)
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
Cert(cate ofAutharization a32455 7'"EDITION (2020)FBC NON-HVHZ EVALUATION FL10674R16
Owens Corning Asphalt Roof Shingles Revlsfon 11: 12/11/2020
Page 5 of 10
6.3.1.2 Berkshire®:
seahnt scrip
La lira de sellador
8Yz" 9Y3' 9lY' 9Yt'
Figure 6: S-Nail Pattern, Berkshire
� NEMo I etc.
Sealant atrlp
La lira de sellador
Figure 7; fi-Nail Pattern, Berkshire
Seahnl strip
La Ifra de sellarbr
• •� t—�•
BYt' 8Yf 8Yt'
r
21. Asplinkroofingcemenf
Cemento de toahodo asfatta
Figure 8: Mansard or Steep Slope Pattern, Berkshire
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
CertlProfe ofAuthorizotion N32455 7r" EDITION )2020) FBC NON-HVHZ EVALUATION FL10674-RI6
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 6 of 10
ONEMOjetc.
6.3.1.3 Duration® Premium, TruDefinition® Duration, Duration® Premium COOL & TruDefinition Duration Designer Color
Collection:
4-Nail Fastening Pattern
SurcNail®festeMng area wltlth
r Nall, Typical
1 12"
Figure 9: Standard 4-Nail Pattern, Duration
Flgure 10: 6-Nail Pattern, Duration
Greater Than 21:12
sareNall®raatanm9 area width
r-Nall, Typical
2^
Pour 1"Spob
Figure 11: Mansard or Steep Slope Pattern, Duration
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
Certncate o/Autharizat/an k32455 7'a EDITION (20201 FBC NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 7 of 10
4 Nail Pettenl
Esquema coil4 clavos
r r
It— 12` —>I I r 12' —>I
65/e"Fkposure Nails 56/8"Exposule�
Exposid6n de 6618pulg. Clams Exposictdn de 6619pulg.
Figure 12: Standard 4-Nail Pattern, Oakridge
6.3.1.5 WeatherGuard® HP:
'4NEM0 I etc.
6 Nall Pattern
Esquema con 6 clavos
r r
I� rC i•- 124
66/8"Fxpasme Credos 66/6"Exposurea
Erposict6u de 5618putg. Expesid6a de 66/8pufg.
Figure 13: 6-Nail Pattern, Oakridge
Fastening for Slopes Greater Than 21:12
r SureNaIM fastening area width
1 Nall, Typical
r' I r 12"
V�
Four 1" apom of AapM1all Roognp Cement
Figure 14: Mansard or Steep -Slope Pattern, Oakridge
6 Nat Pattern
Fsquema eon 6 clavos Nail
6t11e from bottom
ofShia
a 6 118 pping. de at
5 618" Exposure 6 Fasteners parle inferior de la too
Exposicidn de 5 518 pulg. 6 sujetedores
12" 1 1•
12 p1g—;21
NA atod
E1p4g*n�Ee 5 64 pulg &podel6n m85 518 pilg.
Figure 15: 6-Nail Pattern, WeatherGuard HP
Fgur 1" Spots of Asphah Roof Cement
Cuatro punros de cemmto da perhp de as/dfa de 1 pulgada
Figure 16: Mansard or Steep -Slope Pattern, WeatherGuard HP
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
Certlrate oJAuthorization g32455 7'"EDITION (202o) FBC NON-HVH2 EVALUATION FL10674-Riff
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 8 of 10
ONEMOjetc.
6.4 HIP AND RIDGE SHINGLES:
6.4.1 Installation of asphalt shingles shall comply with the Owens Corning current published instructions.
➢ Berkshire Hip and Ridge Shingles with Sealant and DuraRidge® Hip and Ridge Shingles with Sealant require
minimum two (2) nails per shingle.
➢ WeatherGuard' HP Hip and Ridge Shingles and ProEdge® require minimum four (4) nails per shingle.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.4.1.1 Berkshire®Hip and Ridee with Sealant and DuraRidge®HID and Ridge Shingles with Sealant:
Fig. A
Prevailing Wind Direction
Direction del viento predominante
6Faposure--ffll
idindsBpWtl
II P
Figure 17: Isometric View, Berkshire and DuraRidge
WeatherGuard® HP Hip and Ridee Shingles:
Fig. A q 4
PrewllIngwlnd
Direction p
p
Hells
�i A
p
I
p
p I I
Expos�u=`I
f
Fig• B
Top View
Vista superior
1"
1"IH
2"
Nail
2s/a"
Claw
•
Owens Coming suretyal'
I
I
I.
�I d
I
I
I
1<
1211
Figure 18: Plan View, Berkshire and DuraRidge
Fig. C Hip &Ridge Shingle Fastening
TopVievr
NeL ls Nails
T'
,
a' kxpoaure
i2"
Figure 19: Isometric View, WeatherGuard HP Hip and Ridge Figure 20: Plan View, WeatherGuard HP Hip and Ridge
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
certificote o(Autnori:atisn a32455 7TM EDITION 120201 F6C NON-HVHZ EVALUATION FL10674-R16
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 9 of 10
6.4.1.3 ProEdge®:
Prevailing
Wind Direction Sealant Strip
�~ 0' Exposure
Fairies 711�
Cover Exposed
Fasteners with
Roof Cement
Figure 21: Isometric View, ProEdge
Standard-11•�
Fa stoning
Pattern
12' Sealant
7'h° S" Exposure
Is12"�
Figure 22: Plan View, ProEdge
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the Installation of this
product.
Contact the
named
QA entityfor manufacturing facilities covered
by F.A.C. Rule 61G20-3 CW requirements. Refer
to Section 4
herein
for products and production locations having
met codified material standards.
PRI Construction Materials Technologies, LLC—QUA9110; 813 621-6777; bwilson@Dricmt.com
END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 037940.02.12-R31
Certnmte aJAuthorizarlon H32Q55 7'u EDITION (2020) FBC NON-HVH2 EVALUATION FL30674R36
Owens Corning Asphalt Roof Shingles Revision 11: 12/11/2020
Page 10 of 10