Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R405-2020 n� A ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 5406 DELOEON AVE., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=11.0 896.00 ft2 b. N/A R= ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 640.00 ft2 6. Conditioned floor area (ft2) 640 b. N/A R= ft2 c. N/A R= ft2 7. Windows" Description Area 12. Ducts, location & insulation level R ft a. U-Factor: Sgl, U=0.65 25.00 ft2 a. Sup: Attic, Ret: Attic, AH: AHU 6 125 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 SHGC: 13. Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a. Central Unit 18.0 SEER:16.00 SHGC: d. U-Factor. N/A ftz 14. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.300 8. Skylights Description Area 15. Hot water systems Cap: 1 gallons a. U-Factor(AVG): N/A ft2 a. Electric EF: 0.6 SHGC(AVG): WA b. Conservation features 9. Floor Types Insulation Area None a. Raised Floor R=14.0 640.00 ft2 Credits (Performance method) None b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature, Date: ,,Address of New Home: ®� G �,� != City/FL Zip: .J o.i " *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/4/2021 3:52 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 J 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA M TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA r r- Project Name: LUCIANO PISCOTTALOU Builder Name: Street: 5406 DELOEON AVE. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y U Owner. LUCIANO PISCOTTALOU Jurisdiction: w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and skylights and framing shall be sealed. and doors Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor Insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind paning and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or peilinga- a. In addition, inspection of log walls shall be in accordance with the provisions of 1ct:4uu. r^ FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , Florida Department of Business and Professional Regulation - Residential Performance Method .;: ProjectName: LUCIANO PISCOTTAL06 BuilderName: Street: 5406 DELOEON AVE. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, PermitNumber: Owner. LUCIANO PISCOTTALOU Jurisdiction: DesignLocation: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(896.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=11.0 896.00ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c• N/A R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 11. Ceiling Types (640.0 sgft) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 640.00 ft2 6. Conditioned floor area above grade (ft2) 640 b. N/A R= ft2 Conditioned floor area belowgrade(ft2) 0 c. N/A R= ft2 7. Windows(25.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU R ft2 6 125 a. U-Factor: Sgl, U=0.65 25.00 ft2 SHGC: SHGC=0.30 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 18.0 SEER:16.00 c. U-Factor. N/A ft2 SHGC: AreaWeighted Average Overhang Depth: 2.000 ft. 14.Hea Heating kBtuRv Efficiency Area Weighted Average SHGC: 0.300 Striemsp a. Electric Strip Heat 17.0 COP:1.00 8. Skylights Area c. U-Factor.(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Tankless Cap:1 gallons 9. Floor Types (640.0 sgfL) Insulation Area EF:0.600 a. Raised Floor R=14.0 640.00 ft2 b. Conservation features b. NIA R= ft2 None c. N/A R= ft2 16. Credits None Glass/Floor Area: 0.039 Total Proposed Modified Loads: 28.15 PASS Total Baseline Loads: 29.16 1 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this �+�� • " _ _ 0 Code. calculation indicates compliance Gj ii„ ''� _ 'Z- V0 with the Florida Energy Code. PREPA5T�a'2 Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * ° hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. ©D'y► F OWNER/AG BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 'tr sphA PAnr_gn9n INPUT SUMMARY CHECKLIST REPORT PROJECT Title: LUCIANO PISCOTTALOU Bedrooms: 2 Address Type: StreetAddress Building Type: User ConditionedArea: 640 Lot# OwnerName: LUCIANO PISCOTTALOU Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: BuilderName: RotateAngle: 0 Street: 5406 DELOEON AVE. Permit Office: ST. LUCIE COUNTY CrossVentilation: No County. St Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design DailyTemp DesignLocation TMY Site 97.5 % 2.5 % Winter Summer DegreeDays Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 EntireHouse 640 5120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 160 1280 No 1 1 1 Yes Yes Yes 2 BATH 45 360 No 0 1 Yes Yes Yes 3 LIVING/KITCHEN 285 2280 No 0 1 Yes Yes Yes 4 BEDROOM 144 1152 No 0 1 1 Yes Yes Yes 5 AHU 6 48 No 0 1 No Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Raised Floor MASTER BEDRO ---_ -_-- 160 ft2 14 0 1 0 2 Raised Floor BATH -_-_ _--- 45 ft2 14 0 1 0 3 Raised Floor LIVINGIKITCHEN --__ -__- 285 ft2 14 0 1 0 4 Raised Floor BEDROOM ---_ _-_- 144 ft2 14 0 1 0 5 Raised Floor AHU ---_ _--_ 6 ft2 14 0 1 0 fl ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) r 1 Hip Metal 675 ft2 0 ft2 Unfinishe N 0.6 No 0.7 No 20 18.43 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 640 ft2 N N Sheet 1 Z 20 cfrn MASTER BEDROOM 194 cfm Gt • -. -_� LIVI /KITCHEN 711 123 cfm 123 cfm `m-11 lcl.140 cfm 140 cfm BEDROOM Job #: QUICK CALCS, INC. Performed for. WCIANO PISCOTTPLO U 317 SL WCE:LANE 5406DELOEON /WE FT.PERCE, FLXW CT rwrmI rf CI QiY99ai'7711AMMM Scale: 1 : 59 Page 1 RightSdieftrdvesa12019 19.021 RSU08101 2021-Feb0719S223