HomeMy WebLinkAboutAPPROVED- Energy - Revised 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 63/26/2021 8:30 AM
Project Name:
Owner:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie Couty
Philip & Karen Episcopo
Episcopo Residence - Essex Model
Street:
City, State, Zip: Fort Pierce , FL , 34951
4953 Bald Cypress Trail
Permit Number:
Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (ft²)
New (From Plans)
Detached
1
No
1735
7. Windows
a. U-Factor:
S H G C :
b. U-Factor:
S H G C :
c. U-Factor:
S H G C :
Sgl, U=0.56 149.28 ft²
SHGC=0.24
Sgl, U=0.69 96.00 ft²
SHGC=0.22
Sgl, U=0.57 39.57 ft²
SHGC=0.22
9. Floor Types
a. Slab-On-Grade Edge Insulation
b. N/A
c. N/A
R=0.0 1735.00 ft²
R=f t ²
R=f t ²
10. Wall Types
a. Concrete Block - Int Insul, Exterior R=4.1 1647.90 ft²
b. Frame - Wood, Adjacent R=11.0 196.00 ft²
c. N/A R=f t ²
11. Ceiling Types
a. Roof Deck (Unvented)R=20.0 1735.00 ft²
f t ² R=b. N/A
c. N/A R = f t ²
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
13. Cooling systems
14. Heating systems
15. Hot water systems
a. Electric Cap: 50 gallons
b. Conservation features
None
d. N/A R=f t ²
Area Weighted Average Overhang Depth:5.422 ft.
Area Weighted Average SHGC:0.234
Description Area
Insulation Area
Insulation Area
Insulation Area
16. Credits CF, Pstat
3
(308.8 sqft.)
(1843.9 sqft.)
(1735.0 sqft.)
(1735.0 sqft.)
Conditioned floor area below grade (ft²) 0
a. Central Unit
a. Electric Strip Heat
k B t u / h r
28.6 SEER:16.00
Efficiency
k B t u / h r Efficiency
27.0 COP:1.00
f t ² R
6 80
EF: 0.950
8. Skylights
c. U-Factor:(AVG)
S H G C ( A V G ) :
N/A
N/A
f t ²
Area
Glass/Floor Area: 0.178
Total Proposed Modified Loads:
Total Baseline Loads:
57.59
58.07 PASS
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code.
PREPARED BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/AGENT:
DATE:
BUILDING OFFICIAL:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
FORM R405-2020
3-28-2021
PROJECT
Title:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction: St. Lucie County
St. Lucie Couty
1
Philip & Karen Episcopo
Episcopo Residence - Essex
Family Type:
New/Existing:
Bedrooms:
Conditioned Area:
Total Stories:
Worst Case:
Rotate Angle: 0
No
1
1735
3
New (From Plans)
Detached
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
FL , 34951
Fort Pierce ,
St. Lucie
4953 Bald Cypress Trail
Street Address
Comment:
Building Type: User
Cross Ventilation: No
Whole House Fan: No
TMY Site
Design Temp Int Design Temp Heating Design Daily Temp
Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer
CLIMATE
90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______
Number Name Area Volume
BLOCKS
1 Entire House 1735 16309
Number Name Area Volume
SPACES
Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished
1 Bedroom 3 170 1598 No 1 1 Yes Yes1 Yes
2 Bath 54 507.6 No 0 Yes Yes1 Yes
3 Bedroom 2 176 1654.4 No 0 1 Yes Yes1 Yes
4Hall 42394.8No0 Yes Yes1No
5 Foyer 48 451.2 No 0 Yes Yes1 Yes
6Living Room 3303102No0 Yes Yes1 Yes
7 Kitchen 264 2481.6 Yes 0 Yes Yes1 Yes
8Nook 45423No0 Yes Yes1 Yes
9 Master Bedroom 232 2180.8 No 2 1 Yes Yes1 Yes
10 WIC 54 507.6 No 0 Yes Yes1 Yes
11 Master Bath 130 1222 No 0 Yes Yes1 Yes
12 Laundry 80 752 No 0 Yes Yes1No
13 Dining Room 110 1034 No 0 Yes Yes1 Yes
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
1 170 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -27 ft Bedroom 3
2 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath
3 176 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -35 ft Bedroom 2
4 42 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall
3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Type Area Tile Wood Carpet
FLOORS
Perimeter R-Value Joist R-ValueSpace Perimeter
5 48 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft Foyer
6 330 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Living Room
7 264 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -2 ft Kitchen
8 45 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -22 ft Nook
9 232 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -29 ft Master Bedroom
10 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft WIC
11 130 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -10 ft Master Bath
12 80 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Laundry
13 110 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Dining Room
# Type Materials Color Absor.
Roof Solar Deck
Insul.
Pitch
ROOF
Tested
Roof
Area
Gable
Area
Emitt
Tested
EmittSA
(deg)
Rad
Barr
1 Gable or shed Metal 1940 ft² Light 0.6 20 26.57______ No434 ft² 0.9 NoN
ATTIC
# Type Ventilation Area RBS IRCCVent Ratio (1 in)
______ 1 Full attic Unvented 1735 ft² N N0
# Ceiling Type R-Value Area Framing Frac Truss Type
CEILING
Space Ins Type
1 Under Attic (Unvented) 0 170 ft² 0.1 Wood______ Bedroom 3 Blown
2 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ Bath Blown
3 Under Attic (Unvented) 0 176 ft² 0.1 Wood______ Bedroom 2 Blown
4 Under Attic (Unvented) 0 42 ft² 0.1 Wood______ Hall Blown
5 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ Foyer Blown
6 Under Attic (Unvented) 0 330 ft² 0.1 Wood______ Living Room Blown
7 Under Attic (Unvented) 0 264 ft² 0.1 Wood______ Kitchen Blown
8 Under Attic (Unvented) 0 45 ft² 0.1 Wood______ Nook Blown
9 Under Attic (Unvented) 0 232 ft² 0.1 Wood______ Master Bedroom Blown
10 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ WIC Blown
11 Under Attic (Unvented) 0 130 ft² 0.1 Wood______ Master Bath Blown
12 Under Attic (Unvented) 0 80 ft² 0.1 Wood______ Laundry Blown
13 Under Attic (Unvented) 0 110 ft² 0.1 Wood______ Dining Room Blown
3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
# Wall Type R-Value Area
Adjacent Framing Solar
Ornt Fraction Absor.
HeightWidth
Ft In Ft InTo
Cavity Sheathing
R-ValueSpace Grade%
Below
14.1 0Bedroom 3 05014 9S Concrete Block - Int Insul 0.40Exterior 131.8 ft² ____
24.1 0Bedroom 3 05013 9W Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____
34.1 0Bath 05069S Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
44.1 0Bedroom 2 05079N Concrete Block - Int Insul 0.40Exterior 65.9 ft² ____
54.1 0Bedroom 2 05013 9E Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____
64.1 0Bedroom 2 05015 9S Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____
74.1 0Foyer 05089E Concrete Block - Int Insul 0.40Exterior 75.3 ft² ____
84.1 0Living Room 05015 9W Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____
94.1 0Kitchen 05029W Concrete Block - Int Insul 0.40Exterior 18.8 ft² ____
10 4.1 0Nook 05069N Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
11 4.1 0Nook 05069S Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
12 4.1 0Nook 05010 9W Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____
13 4.1 0Master Bedro 05016 9N Concrete Block - Int Insul 0.40Exterior 150.7 ft² ____
14 4.1 0Master Bedro 05013 9W Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____
15 4.1 0WIC 05069N Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____
16 4.1 0Master Bath 05010 9N Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____
17 4.1 0Dining Room 05011 9E Concrete Block - Int Insul 0.40Exterior 103.6 ft² ____
18 4.1 0Dining Room 05049S Concrete Block - Int Insul 0.40Exterior 37.7 ft² ____
19 11 0Laundry 489E Frame - Wood 0.40.23Garage 74.7 ft² ____
20 11 0Master Bath 413 9E Frame - Wood 0.40.23Garage 121.3 ft² ____
# Door Type U-Value AreaStorms
DOORS
Ornt Space
Width
Ft In Ft In
Height
1Insulated .39 20.5 ft² None______ E Foyer 1063
2Insulated .39 17.8 ft² None______ E Laundry 8682
# Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening
WINDOWS
Overhang
Orientation shown is the entered, Proposed orientation.
Wall
ID Imp
1 W Low-E Single 0.56 0.24 24.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes2Y
2 S Low-E Single 0.56 0.24 8.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes3Y
3 E Low-E Single 0.56 0.24 28.9 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes5Y
4 E Low-E Single 0.39 0.25 7.9 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______ Yes7Y
5 E Low-E Single 0.3 0.28 16.0 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______ Yes7Y
6 W Low-E Single 0.69 0.22 96.0 ft² 10 ft 0 in 1 ft 4 in NoneVinyl None______ Yes8Y
7 N Low-E Single 0.56 0.24 11.1 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes10 Y
8 S Low-E Single 0.56 0.24 11.1 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes11 Y
9 W Low-E Single 0.56 0.24 24.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes12 Y
10 W Low-E Single 0.56 0.24 24.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes14 Y
11 N Low-E Single 0.56 0.24 18.2 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes16 Y
12 E Low-E Single 0.57 0.22 39.6 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes17 Y
3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
# Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
GARAGE
1 441 ft² 441 ft² 21 ft 9.4 ft 11______
Method CFM 50 ACH 50ELASLAScope
INFILTRATION
ACHEqLA#
1630.9 689.48.000358Wholehouse .1155167.98Proposed ACH(50)1
HEATING SYSTEM
# System Type Efficiency Capacity DuctsSubtype BlockSpeed
1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1
# System Type Efficiency Capacity Air Flow SHR
COOLING SYSTEM
DuctsSubtype BlockSubtype
1 Central Unit/ SEER: 16 28.6 kBtu/hr 858 cfm 0.7______ sys#1Split 1 Singl
# System Type EF Cap Use SetPnt Conservation
HOT WATER SYSTEM
SubType Location
1Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage
FSEC
Company Name System Model # Collector Model #
Collector
SOLAR HOT WATER SYSTEM
Storage
FEFCert # Area Volume
None None f t ² ______
# Location R-Value Area Location Area
---- Supply ---- ---- Return ----
Leakage Type Handler
CFM 25Air
QN RLF
DUCTS
Heat Cool
HVAC #
TOT OUT
CFM25
1 Attic 6 80 ft² Attic 15 ft² Prop. Leak Free Attic 52.0 cfm 0.03 0.50______ 1 1 --- cfm
3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y Ceiling Fans:
Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec
[ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078
Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878
Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bedroom 3
Default(8 lbs/sq.ft. f t ² f t 0.3 Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2
Default(8 lbs/sq.ft. f t ² f t 0.3 Hall
Default(8 lbs/sq.ft. f t ² f t 0.3 Foyer
Default(8 lbs/sq.ft. f t ² f t 0.3 Living Room
Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen
Default(8 lbs/sq.ft. f t ² f t 0.3 Nook
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom
Default(8 lbs/sq.ft. f t ² f t 0.3 WIC
Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bath
Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry
Default(8 lbs/sq.ft. f t ² f t 0.3 Dining Room
3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT