Loading...
HomeMy WebLinkAboutAPPROVED- Energy - Revised 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 63/26/2021 8:30 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie Couty Philip & Karen Episcopo Episcopo Residence - Essex Model Street: City, State, Zip: Fort Pierce , FL , 34951 4953 Bald Cypress Trail Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 1735 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.56 149.28 ft² SHGC=0.24 Sgl, U=0.69 96.00 ft² SHGC=0.22 Sgl, U=0.57 39.57 ft² SHGC=0.22 9. Floor Types a. Slab-On-Grade Edge Insulation b. N/A c. N/A R=0.0 1735.00 ft² R=f t ² R=f t ² 10. Wall Types a. Concrete Block - Int Insul, Exterior R=4.1 1647.90 ft² b. Frame - Wood, Adjacent R=11.0 196.00 ft² c. N/A R=f t ² 11. Ceiling Types a. Roof Deck (Unvented)R=20.0 1735.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 50 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:5.422 ft. Area Weighted Average SHGC:0.234 Description Area Insulation Area Insulation Area Insulation Area 16. Credits CF, Pstat 3 (308.8 sqft.) (1843.9 sqft.) (1735.0 sqft.) (1735.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 28.6 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 80 EF: 0.950 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.178 Total Proposed Modified Loads: Total Baseline Loads: 57.59 58.07 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 3-28-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: St. Lucie County St. Lucie Couty 1 Philip & Karen Episcopo Episcopo Residence - Essex Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle: 0 No 1 1735 3 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , 34951 Fort Pierce , St. Lucie 4953 Bald Cypress Trail Street Address Comment: Building Type: User Cross Ventilation: No Whole House Fan: No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 % Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1735 16309 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 Bedroom 3 170 1598 No 1 1 Yes Yes1 Yes 2 Bath 54 507.6 No 0 Yes Yes1 Yes 3 Bedroom 2 176 1654.4 No 0 1 Yes Yes1 Yes 4Hall 42394.8No0 Yes Yes1No 5 Foyer 48 451.2 No 0 Yes Yes1 Yes 6Living Room 3303102No0 Yes Yes1 Yes 7 Kitchen 264 2481.6 Yes 0 Yes Yes1 Yes 8Nook 45423No0 Yes Yes1 Yes 9 Master Bedroom 232 2180.8 No 2 1 Yes Yes1 Yes 10 WIC 54 507.6 No 0 Yes Yes1 Yes 11 Master Bath 130 1222 No 0 Yes Yes1 Yes 12 Laundry 80 752 No 0 Yes Yes1No 13 Dining Room 110 1034 No 0 Yes Yes1 Yes # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 170 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -27 ft Bedroom 3 2 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft Bath 3 176 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -35 ft Bedroom 2 4 42 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Hall 3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 5 48 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -8 ft Foyer 6 330 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Living Room 7 264 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -2 ft Kitchen 8 45 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -22 ft Nook 9 232 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -29 ft Master Bedroom 10 54 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft WIC 11 130 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -10 ft Master Bath 12 80 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft Laundry 13 110 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -15 ft Dining Room # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Gable or shed Metal 1940 ft² Light 0.6 20 26.57______ No434 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 1735 ft² N N0 # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented) 0 170 ft² 0.1 Wood______ Bedroom 3 Blown 2 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ Bath Blown 3 Under Attic (Unvented) 0 176 ft² 0.1 Wood______ Bedroom 2 Blown 4 Under Attic (Unvented) 0 42 ft² 0.1 Wood______ Hall Blown 5 Under Attic (Unvented) 0 48 ft² 0.1 Wood______ Foyer Blown 6 Under Attic (Unvented) 0 330 ft² 0.1 Wood______ Living Room Blown 7 Under Attic (Unvented) 0 264 ft² 0.1 Wood______ Kitchen Blown 8 Under Attic (Unvented) 0 45 ft² 0.1 Wood______ Nook Blown 9 Under Attic (Unvented) 0 232 ft² 0.1 Wood______ Master Bedroom Blown 10 Under Attic (Unvented) 0 54 ft² 0.1 Wood______ WIC Blown 11 Under Attic (Unvented) 0 130 ft² 0.1 Wood______ Master Bath Blown 12 Under Attic (Unvented) 0 80 ft² 0.1 Wood______ Laundry Blown 13 Under Attic (Unvented) 0 110 ft² 0.1 Wood______ Dining Room Blown 3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS # Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 14.1 0Bedroom 3 05014 9S Concrete Block - Int Insul 0.40Exterior 131.8 ft² ____ 24.1 0Bedroom 3 05013 9W Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____ 34.1 0Bath 05069S Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 44.1 0Bedroom 2 05079N Concrete Block - Int Insul 0.40Exterior 65.9 ft² ____ 54.1 0Bedroom 2 05013 9E Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____ 64.1 0Bedroom 2 05015 9S Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____ 74.1 0Foyer 05089E Concrete Block - Int Insul 0.40Exterior 75.3 ft² ____ 84.1 0Living Room 05015 9W Concrete Block - Int Insul 0.40Exterior 141.3 ft² ____ 94.1 0Kitchen 05029W Concrete Block - Int Insul 0.40Exterior 18.8 ft² ____ 10 4.1 0Nook 05069N Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 11 4.1 0Nook 05069S Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 12 4.1 0Nook 05010 9W Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____ 13 4.1 0Master Bedro 05016 9N Concrete Block - Int Insul 0.40Exterior 150.7 ft² ____ 14 4.1 0Master Bedro 05013 9W Concrete Block - Int Insul 0.40Exterior 122.4 ft² ____ 15 4.1 0WIC 05069N Concrete Block - Int Insul 0.40Exterior 56.5 ft² ____ 16 4.1 0Master Bath 05010 9N Concrete Block - Int Insul 0.40Exterior 94.2 ft² ____ 17 4.1 0Dining Room 05011 9E Concrete Block - Int Insul 0.40Exterior 103.6 ft² ____ 18 4.1 0Dining Room 05049S Concrete Block - Int Insul 0.40Exterior 37.7 ft² ____ 19 11 0Laundry 489E Frame - Wood 0.40.23Garage 74.7 ft² ____ 20 11 0Master Bath 413 9E Frame - Wood 0.40.23Garage 121.3 ft² ____ # Door Type U-Value AreaStorms DOORS Ornt Space Width Ft In Ft In Height 1Insulated .39 20.5 ft² None______ E Foyer 1063 2Insulated .39 17.8 ft² None______ E Laundry 8682 # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 W Low-E Single 0.56 0.24 24.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes2Y 2 S Low-E Single 0.56 0.24 8.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes3Y 3 E Low-E Single 0.56 0.24 28.9 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes5Y 4 E Low-E Single 0.39 0.25 7.9 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______ Yes7Y 5 E Low-E Single 0.3 0.28 16.0 ft² 8 ft 0 in 1 ft 4 in NoneVinyl None______ Yes7Y 6 W Low-E Single 0.69 0.22 96.0 ft² 10 ft 0 in 1 ft 4 in NoneVinyl None______ Yes8Y 7 N Low-E Single 0.56 0.24 11.1 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes10 Y 8 S Low-E Single 0.56 0.24 11.1 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes11 Y 9 W Low-E Single 0.56 0.24 24.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes12 Y 10 W Low-E Single 0.56 0.24 24.0 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes14 Y 11 N Low-E Single 0.56 0.24 18.2 ft² 1 ft 7 in 1 ft 4 in NoneVinyl None______ Yes16 Y 12 E Low-E Single 0.57 0.22 39.6 ft² 6 ft 0 in 1 ft 4 in NoneVinyl None______ Yes17 Y 3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation GARAGE 1 441 ft² 441 ft² 21 ft 9.4 ft 11______ Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1630.9 689.48.000358Wholehouse .1155167.98Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtype BlockSpeed 1 Electric Strip Heat/ COP:1 27 kBtu/hr ______ sys#1None 1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtype BlockSubtype 1 Central Unit/ SEER: 16 28.6 kBtu/hr 858 cfm 0.7______ sys#1Split 1 Singl # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1Electric 0.95 50 gal 60.9 gal 120 deg None______ None Garage FSEC Company Name System Model # Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert # Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply ---- ---- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 80 ft² Attic 15 ft² Prop. Leak Free Attic 52.0 cfm 0.03 0.50______ 1 1 --- cfm 3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec[X] Dec[X] Nov[X] Nov[ ] Oct[X] Oct[ ] Sep[ ] Sep[ ] Aug[ ] Aug[ ] Jul[ ] Jul[ ] Jun[ ] Jun[X] Jun[ ] May[ ] May[ ] Apr[X] Apr[X] Mar[X] Mar[X] Feb[ ] Feb[X] Jan[ ] JanHeatingVenting Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AMPM 7880 7880 7878 7878 7878 7878 7878 7878 8078 8078 8078 8078 Cooling (WEH) AMPM 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 7878 Heating (WD) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 Heating (WEH) AMPM 6668 6668 6668 6668 6668 6868 6868 6868 6868 6868 6866 6866 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft² 0 ft 0.3 Bedroom 3 Default(8 lbs/sq.ft. f t ² f t 0.3 Bath Default(8 lbs/sq.ft. f t ² f t 0.3 Bedroom 2 Default(8 lbs/sq.ft. f t ² f t 0.3 Hall Default(8 lbs/sq.ft. f t ² f t 0.3 Foyer Default(8 lbs/sq.ft. f t ² f t 0.3 Living Room Default(8 lbs/sq.ft. f t ² f t 0.3 Kitchen Default(8 lbs/sq.ft. f t ² f t 0.3 Nook Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bedroom Default(8 lbs/sq.ft. f t ² f t 0.3 WIC Default(8 lbs/sq.ft. f t ² f t 0.3 Master Bath Default(8 lbs/sq.ft. f t ² f t 0.3 Laundry Default(8 lbs/sq.ft. f t ² f t 0.3 Dining Room 3/26/2021 8:30 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT