Loading...
HomeMy WebLinkAboutBuilding PlansPROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03-05-21 GENERAL NOTES 1. THIS PLANS WERE PREPARED USING THE 2020 FLORIDA BUILDING CODE 7TH EDITION. 2. TYPE OF CONSTRUCTION: CLASS V. UNPROTECTED, GROUP R3 OCCUPANCY PER FLORIDA BUILDING CODE. 3. CONSTRUCTION SHALL FOLLOW THE FLORIDA BUILDING CODE AS ADAPTED BY THE COUNTY AND ALL APPLICABLE AMENDMENTS. 4. THESE PLANS, AS DRAWN AND NOTED, COMPLY WITH THE BUILDING ENVELOPE ENERGY REQUIREMENTS OF THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY. 5. ALL WINDOWS AND DOORS SHALL BE CAULKED AND WEATHER STRIPPED. WINDOW UNITS SHALL DISPLAY LABELS SHOWING COMPLIANCE WITH THE F.B.C. CHAPTER 13 ENERGY EFFICIENCY SECTION. 6. REGISTERED BAITING SYSTEM FOR TERMITE TREATMENT TO BE INSTALLED AND MONITERED THIRD PARTY PRIOR TO FINAL BUILDING APPROVAL PER F.B.C. 2020 M 1.1.1:11THAV91PC� ABV ABOVE AFF ABOVE FINISHED FLOOR AHU AIR HANDLER UNIT B.F. BI FOLD B.P. BI PASS BLK. BLOCK BLW. BELOW BRG. BEARING BTM. BOTTOM CLG. CEILING CMU CONCRETE MASONRY UNITS COL COLUMN CONC. CONCRETE CSMT. CASEMENT DBL DOUBLE DIAL DIAMETER DISP. DISPOSAL OP DESIGN PRESSURE DR. DOOR DW DISH WASHER E.E. EACH END ELEC. ELECTRICAL ELEV. ELEVATION ES. EACH SIDE EXT, EXTERIOR F.B.C. FLORIDA BUILDING CODE F.R. FIRE RATED FIR FRENCH DOOR FIN. FINISHED FL FLOOR G.T. GIRDER TRUSS GA. GAUGE CALM. GALVANIZED OR GROUND FAULTINTERRUPT GL GLASS ONE! GYPSUM WALLBOARD GYP. BD. GYPSUM WALLBOARD HOT. HEIGHT HPS. HOOPS HILL HOUR HS HORIZONTAL SLIDING HVHZ HIGH VELOCITY HURRICANE ZONE INS. INSULATION INT. INTERIOR LG. LONG UN. UNEN LT. LIGHT LT. LAUNDRY TUB MASONRY NOTES PLAN NOTES FRAMING NOTES ELECTRICAL NOTES 1. CONCRETE UNITS TO BE ASTM C 90-90. ASTM GRADES NI OR NIT. PROVIDE PRECAST UNTELS AS NECESSARY. (fm = 1500 PSI) 1. PROVIDE 1x2 P.T. FlRESTOP HORIZONTAL 0 CEILING & WALL INTERSECTIONS OR 6'-G' O/C 1. THE TRUSS LAYOUT SHOWN ON THIS SHEET IS SCHEMATIC IN NATURE. HOWEVER, THE 1. CONTRACTOR SHALL VERIFY WITH ELECTRIC PROVIDER THE LOCATION OF SERVICE AND THESE PLANS WERE PREPARED VERT. MAX. AND ALL OTHER LOCATIONS PER F.B.C. SECTION 718 SUPPORTINGSUPERSTRUCTUREHAS BY�PA ESIGN UNDERTHETHE SHALL LOCATED METER 3 PANELS AS REQUIRED. 2. MORTAR TYPE M PER ASTM C 270 92. WILL DESIGNERS LAYOUT.THAT USING THE 2020 FLORIDA BUILDING CODE 7th EDITION 3. CELLS, LINTELS AND BONG BEAMS WHERE SPECIFIED SHALL BE FILLED W/ 3000 PSI PEA 2 ALL GLAZING WITHIN 24" AND PARALLEL TO A DOOR SHALL BE TEMPERED. 2 ALL WERE SHALL BE THHN COPPER. UNLESS NOTED OTHERWISE. GRAVEL CONCRETE. URES AT OR WITHIN 36- OF TUBS OR SFLOOR�SHALLL SIDELIGHTS,SHOWERS THA�O' BEARING CAN YCHFTTER(OIBTANNG LLESS ABOVEBE TEMPERED. GLASS N S DING GLASS BE MODIFIED ON PERMISSION FROM THE PRIME PROFEESSIONAL OF 3. WHERE REQUIRED BY OTHER CODES, SERVICE AND FEEDER CONDUCTORS SHALL BE 4. REINFORCING: DOORS AND FRENCH DOORS SHALL BE TEMPERED. RECORD WHO MUST REVIEW PROPOSED CHANGES AND AUTHORIZE STRUCTURAL REVISIONS COPPER OF EQUAL AMPACITY. ACCORDINGLY. VERTICAL: 3. EGRESS WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS 4. ALL BRANCH CIRCUITS IN RACEWAY OR NON METALUC SHEATHED CABLE. EGRESS WINDOWS SHALL HAVE A MINIMAL NET OPENING OF 24' HIGH, 20' WIDE, AND MIN. NET 3. FINAL SIGNED AND SEALED ENGINEERED TRUSS DESIGN MUST BE SUBMITTED TO THIS A. ASTM A815-94 PER REINFORCING SECTION (GRADE 60). AREA OF 5.7 S.F. FOR 2nd FLOOR WINDOWS AND 5.0 S.F. FOR lot FLOOR WINDOWS. THE OFFICE FOR REVIEW. TRUSS DESIGNERS MUST PROVIDE ALL TRUSS CONNECTIONS AS PART OF 5. COORDINATE RACEWAY INSTALLATIONS WITH OTHER TRADES PRIOR TO CONSTRUCTION. BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' ABOVE THE FLOOR. THE DESIGN. B. WHEN A FOUNDATION DOWEL DOES NOT LINE UP WITH A VERTICAL CORE, IT SHALLNOT BE 6. VERIFY ALL CONDUCTORS AND BREAKERS WITH EQUIPMENT MANUFACTURER SLOPED MORE THAN ONE HORIZONTAL IN SIX VERTICAL ALIGNMENT, EVEN THOUGH IT IS IN AN 4• IN AREAS OTHER THAN HVHZ FIXED GLASS THICKNESS SHALL COMPLY WITH SECTION 2411 4. TRUSS MANUFACTURER SHALL SUBMIT THREE (3) COPIES OF SHOP DRAWINGS AND SPECIFICATIONS. ADJACENT CELL TO THE VERTICAL WALL REINFORCING. OF F.B.C. AS THE MINIMUM THICKNESS ALLOWED. ENGINEERING CALCULATIONS SIGNED AND SEALED BY A FLORIDA REGISTERED ENGINEER, OF C. VERTICAL REINFORCING STEEL SHALL HAVE A MINIMUM CLEARANCE OF ONE-HALF INCH FROM THE MASONRY. 5. PROVIDE A MINIMUM OF 4" GEAR ALL AROUND AIR HANDLER UNITS. THEIR ROOF TRUSS DESIGN FOR REVIEW INCLUDING TWO (2) COPIES FOR ARCHITECTS REVIEW PRIOR TO FABRICATION. RENEW OF TRUSS SHOP DRAWINGS IS A COURTESY BY THE ARCHITECT AND IN NO WAY RELIEVES THE TRUSS MANUFACTURER OF HIS RESPONSIBILITY TO 7. PROVIDE DISCONNECT SWITCH OF SIZE AS REQUIRED BY LOAD AND UNITS 8. PROVIDE NON -FUSIBLE GENERAL DUTY SAFETY SNITCHES AT A/C EQUIP. AND AT 8. PROVIDE A LAYOUT THAT FULLY INTEGRATES WITH THE ARCHITECTS SUPERSTRUCTURE. IF PUMPS NOT VISIBLE FROM CIRCUIT BREAKER PANEL AND AS PER MANUFACTURER. M.C. MEDICINE CABINET SMS SHEET METAL SCREWS D. VERTICAL REINFORCING SHALL BE AS LOCATED ON THE PUN AND AS INDICATED IN THE ALL DWELLING ROOMS MUST HAVE HVAC RETURNS. RETURNS MAY BE DUCTED, JUMPERS OR THERE IS ANY CONFLICT OR ADDITIONAL STRUCTURE NEEDED, THE TRUSS COMPANY SHALL RECOMMENDATIONS. M.R.H. MEAN ROOF HEIGHT ST. STIRRUPS COLUMN SCHEDULE TRANSFER GRILLES. NOTIFY THE ARCHITECT IN WRITING OF THE SPECIFIC AREAS OF CONCERN. M.T. METAL THRESHOLD STL STEEL 7. A/C UNITS MAY HAVE CONIC. PAD OR OTHER APPROVED MATERIAL EXTENDING ABV. 9. PROVIDE GFl BREAKERS FOR ALL BATHROOMS, GARAGE AND EXTERIOR OUTLETS AS MAX. MAXIMUM SW SWITCH MFR. MANUFACTURER TEMP. TEMPERED E VERTICAL REINFORCING EACH SIDE OF ANY OPENING, IF REQUIRED, SHALL BE CONTINUOUS TO THE TIE BEAM. PRECAST UNTELS SHALL HAVE OPENINGS TO ALLOW REINFORCING BARS TO ADJOINING GRADE OR SHALL BE SUSPENDED A MIN. OF 6" ABV. ADJOINING GRADE 5. TRUSSES TO BE DESIGNED TO CARRY LOADS OF ATTIC AHU AND MISC. EQUIPMENT. COORDINATE LOCATIONS WITH BUILDER PRIOR TO FABRICATION AND INDICATE ON TRUSS SHOWN ON PLANS, MICRO. MICROWAVE T.B. TROUGH BOLT CONTINUE UNINTERRUPTED. DRAWINGS. 10. ELECTRICAL FIXTURES, TRIM AND APPLIANCES SHALL BE UL APPROVED AND AS MIN. MINIMUM T.O. THROUGH OUT BEAM SCHEDULE NOTES SELECTED BY BUILDER. M.O. MASONRY OPENING T.O.B.B. TOP OF MASONRY BOND BEAM HORIZONTAL, 6. ALL INTERIOR LOAD BEARING PARTITIONS TO BE CONSTRUCTED WITH CUPS, TOP AND MONO. MONOLITHIC T.O.PL TOP OF WOOD PLATE BOTTOM EACH STUD, AS PER CODE. 11. DROVIDE PRE -WIRED TELEPHONE OUTLETS AS SHOWN ON PLAN. MTL METAL T.O.T.B, TOP OF TIE BEAM A. HORIZONTAL REINFORCEMENT SHALL BE PROVIDED AS SCHEDULED IN THE BEAM SCHEDULE. 1. ALL COMPOSITE LINTEL (MARK 'L') TOP BARS SHALL BE CONTINUOUS UNLESS OTHERWISE O.H.D. OVER HEAD DOOR TYP. TYPICAL NOTED 7. STRUCTURAL WOOD AND TIMBER FRAMING SHALL CONFORM TO THE "TIMBER CONSTRUCTION 12 PROVIDE PRE- WIRED T.V. OUTLETS FOR CABLE AS SHOWN ON PLANS. O/C ON CENTER U.N.O. UNLESS NOTED OTHERWISE 5. GENERAL MANUAL' AS PUBLISHED BY THE AMERICAN INSTITUTE OF TIMBER CONSTRUCTION. P.L.F. POUNDS PER LINEAR FOOT UL UNDERWRITERS LABORATORIES 2. ALL BOND BEAMS (MARK 'BB") REINFORCING SHALL BE CONTINUOUS THROUGH BOND 13. DEDICATED CIRCUITS SHALL HAVE NO MORE THEN 6 DUPLEX RECEPTACLES. P.S.F. POUNDS PER SQUARE FOOT V.I.F. VERIFY IN FIELD A. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-05/ A.S.C.E. BEAMS ONLY. ALL SPLICES TO BE A MINIMUM OF 48 BAR DIAMETERS. 8. ALL WOOD IN CONTACT VAIN MASONRY OR CONCRETE SHALL E PRESSURE TREATED. P.S.I. POUNDS PER SQUARE INCH W.A. WEDGE ANCHORS 7-16/T.M.S. 402-05, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE PROVIDE AN APPROVED MOISTURE VAPOR BARRIER BETWEEN THE CONCRETE OR OTHER 14. IN KITCHENS, DINING ROOMS AND BATHROOMS, RECEPTACLE OUTLETS FOR COUNTER P.T. PRESSURE TREATED W/ WITH COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. 3. BOND BEAM SCHEDULE DEPTHS ARE MINIMUM AND MAY BE INCREASED 8' TO FIT BLOCK CEMFNTITOUS MATERIALS AND THE WOOD AS PER CODE. SPACES SHALL BE GFCI PROTECTED ACCORDING TO NEC 210-8(a). PART'N. PARTITION WC WATER CLOSET WORK. PKT. POCKET WIT. WOOD B. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530.1-05/A.S.C.E 7-16/T.M.S, 602- S. CARPENTER SHALL BE RESPONSIBLE FOR PROVIDING ADEQUATE BRACING AND BRIDGING USED 15. ALL CLOSET UGHTING SHELL COMPLY WITH NEC SEC. 410.8. PLYWD. PLYWOOD 05, SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS 4. REFER TO CONCRETE NOTES FOR INFORMATION ON CONCRETE AND STEEL SPECIFICATIONS. DURING ERECTION OF TRUSSES TO PREVENT COLLAPSE OR DAMAGE. R.O. ROUGH OPENING FOR MASONRY STRUCTURES. 16. SMOKE DETECTORS SHALL BE CONNECTED TO KITCHEN OR BATH LIGHTING CIRCUITS S.C. SOLID CORE S.G.D. SUDING GLASS DOOR 6. VERTICAL CELLS FOR MASONRY TO BE GROUTED SHALL HAVE VERTICAL ALIGNMENT CONCRETE NOTES 10. HEADERS FOR FRAMED OPENINGS GREATER THAN 6'-0' MUST BE ENGINEERED AND STAMPED BY AHEAD OF SNITCH AND HAVE SELF CONTAINED BATTERY BACK-UP. DETECTORS SHALL BE TANDEM WIRED SO ALL DETECTORS SOUND SIMULTANEOUSLY. IF SQUARE FOOT SUFFICIENT TO MAINTAIN A CLEAR, UNOBSTRUCTED CONT. CELL THE TRUSS MANUFACTURER. (UNLESS NOTED OTHERWISE) SH SINGLE HUNG 7. CLEANOUT OPENINGS SHALL BE PROVIDED AT THE BOTTOM OF GROUTED CELLS AT EACH 1. CONCRETE SHALL CONFORM TO ASTM C94-94 AND SHALL HAVE STRENGTH IN 28 DAYS AS 11. ALL HEADERS OVER DOORS AND WINDOWS TO BE (2) OR (3) 2X12'S UNLESS OTHERWISE 17. PREWIRE FOR GARAGE DOOR OPENER SENSOR. INDIAN RIVER COUNTY PRODUCT APPROVAL OPENING SCHEDULE: OVERHEAD DOORS, SLIDING DOORS, FIXED GLASS, WINDOWS & SKYLIGHTS OPEN ID PRODUCT MODEL # MANUF. GLASS ATTACH. METHOD TYPE SIZE, SPACING BUILDING DESIGN PRODUCT DESIGN DESCRIPTION AND EMBED. *FILL ALL MANUF. HOLES PRESSURE PRESSURE A FL-9174.10 R13 9100 OHD 16070 WAYNE DICTION N/A W/ 1-1/4' WASHER & 2-3/4' MIN. EMBED. D.P.= +29.3 PSF +39.2 PSF -43.7 PSF 2-3/4" MN. EDGE DISTANCE. 6' FROM END -34.70 PSF B FL-20468.4 3080 OR THERMA TRU N/A 1/4' TAPCONS W/ 1-1/4" MIN. EMBED CORNERS 0 D.P.= +31.9 PSF +60.0 PSF -60.0 PSF RAISED PANEL 4' & 1&5' O/C MAX SPACING. -34.7 PSF C FL 17499.9 SH 36 MI WINDOWS & DRS SGL IMPACT 3/18' TAPCONS W/ 1-1/4' MIN EMBED D.P.= +31.9 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX SPACING & 2" FROM EDGE -34.7 PSF +60.0 PSF -70.0 PS D FL 17499.9 SH 25 MI WINDOWS & DRS SGL IMPACT 3PO' TAPCONS W/ 1-1/4' MIN EMBED D.P.= +31.9 PSF +55.0 PSF -55.0 PSF FL 17499.9 0 i O/C MAX PACING & 2' FROM EDGE -34.7 PSF +60.0 PSF -70.0 PS E FL 17499.9 SH 15 MI WINDOWS &DRS SGL IMPACT 3/18" W/ MIN EMBED D.P.= +33.4 PSF +60.0 PSF -70.0 PSF C MAX 0 0 C MAX S NO & 2' FROM EDGE NO & -36.3 PSF +60.0 PSF -70.0 PSF F FL 17499.9 SH 15 MI WINDOWS & DRS SGL IMPACT 3r_Q Ti1 APCON 1-1/4' MIN EMBED D.P.= +33A PSF +55.0 PSF -55.0 PSF SPW/ O 1 ,_ C MAXONG & " FROM EDGE -36.3 PSF +80.0 PSF -70.0 PSF G FL 17499.9 (2) SH 26 MI WINDOWS & DRS SGL IMPACT 3/16" TAPCONS W/ 1-1/4' MIN EMBED D.P.= +29.9 PSF +55.0 PSF -55.0 PSF 0 10° O/C MAX SPACING & 2" FROM EDGE -37.7 PSF +60.0 PSF -70.0 PSF H FL 22401.3 12080 SGD MI WINDOWS & DRS SGL IMPACT 3/16" TAPCONS W/ 1-1/4' MIN EMBED D.P.= +28.4 PSF +55.0 PSF -55.0 PSF 0 12' O/C MAX SPACING -31.2 PSF I FL 17499.9 SH 25 MI WINDOWS & DRS SGL IMPACT 3/16" TAPCONS W/ 1-1/4' MIN EMBED DR= +31.9 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX SPACING & 2" FROM EDGE -34.7 PSF +60.0 PSF -70.0 PSF J FL 15349.10 6020 TRANSOM MI WINDOWS & DRS SGL IMPACT 3,16' TAPCONS W/ 1-1/4" MIN EMBED D.P.= +33.4 PSF +55.0 PSF -55.0 PSF EQUAL SPACING & 3' FROM EDGE -36.3 PSF K FL 17499.9 SH H33 MI WINDOWS & DRS SGL IMPACT 3/16' TAPCONS W/ 1-1/4' MIN EMBED D.P.=+33.4 PSF +55.0 PSF -55.0 PSF 0 10' O/C MAX SPACING & 2" FROM EDGE -36.3 PSF +60.0 PSF -70.0 PSF L FL 17499.9 SH 35 MI WINDOWS & DRS SGL IMPACT 3116' TAPCONS W/ 1-1/4' MIN EMBED D.P.- +31.9 PSF +55.0 PSF -55.0 PSF 0' C M SPAd & 2' OM EDGE-34.7 PSF +60.0 PSF -70.0 PSF M FL-9174.10 R13 9100 OHD 8070 WAYNE DALTYXN N/A W/ 1-1/4' WASHER & 2-3/4' MIN. EMBED. D.P.= +28.4 PSF +39.2 PSF -43.7 PSF 2-3/4' MIN. EDGE DISTANCE. 6- FROM END -31.2 PSF N FL 17499.9 SH 26 MI WINDOWS & DRS SGL IMPACT 3/16" TAPCONS W/ 1-1/4" MIN EMBED D.P.= +31.9 PSF +55.0 PSF -55.0 PSF 0IV O/C MAX SPACING & 2' FROM EDGE -34.7 PSF +60.0 PSF -70.0 PSF 0 FL 17499.9 SH 26 MI WINDOWS & DRS SGL IMPACT 3/78' TAPCONS W/ i-i/4' MIN EMBED D.P.= +31.9 PSF +55.0 PSF -55.0 PSF FL 1749g.81.0 10' C MAX SPACING & 2" FROM EDGE -34.7 PSF +60.0 PSF -70.0 PSF PRODUCT MODEL # MANUF. ATTACHMENT METHOD BUILDING DESIGN PRODUCT DESIGN TYPE, SIZE, SPACING, EMBED., STIFFENERS, ETC PRESSURE PRESSURE MULLIONS FL 83" H 8 MAX. 83" HORIZ MI WINDOWS 1/4' TAPOONS W/ 1-1/4' MIN EMBED FL 15353.9 & DOORS (4) FASTENERS PER CUP TOP & ITEM. 37.7 PSF 54.0 PSF -54.0 PSF MAX. 156-3 8' VERT. MULLIONS FL 17472.2 MAX. 109" LENGTH EASTERN ARCHITECTURAL 1/4' TAPOONS W/1-3/4' MIN. EMBED (8) FASTENERS PER H-CUP 34.7 PSF 36.4 PSF -36.4 PSF MAX 48' TRIBUTARY WIDTH SYSTEMS ROOFING NOA NO. 18-0829.05 EAGLE ROOFING (2) 10d RING SHANK NAILS -83.4 psf -172 paf. BEL-AIR CONCRETE TILE PRODUCTS ROOFING FL 5374-RS HIP AND RIDGE CHANNEL METAL EAST COAST METALS, INC 3M 2 COMPONENT FOAM ROOF TILE ADHESIVE AH-160 -83.4 sf P -169 sf. P ROOFING UNDERLAYMENT ASTM D-226 %30 FELT N/A MEMBRANE: 30/ FELT BUTTON CAPS 12° GRID, 6' O.C. AT A MIN. 4" HEAD LAP N/A N/A ROOFING UNDERLAYMENT NOA NO. 17-0614-.22 POLYGUSA MEMBRANE POLYSTICK TU MAX SELF ADHERED 1 OR MORE PEEL & STICKHEAD SBS UNDERLAYMENT INC.S PLIES NAILS AND TIN CAPS 12- GRID, 6. O.C. AT A MIN. 4- N/A N/A LAP SIDING STUCCO N/A N/A N/A N/A SOFFIT STUCCO N/A 7/8' LG, 16 GA. CORROSION RESISTANT STAPLES TO HE RIB LATH N/A N/A SPACED NOT MORE THAN 6' LEFT OVER 4'-O' HIGH. CLEANOUTS SHALL BE SEALED AFTER CLEANING AND INSPECTION, AND SPECIFIED IN THE FOUNDATION AND MASONRY NOTES (UNLESS NOTED OTHERWISE) ALL NOTED. (FOR WOOD FRAME CONSTRUCTION DEPENDING ON ALL WALL THICKNESS). 18, ARC FAULT -INTERRUPTER PROTECTION PER NEC 210.12. REQUIRED FOR ALL 120-VOLT, BEFORE GROUTING CONCRETE WORK SHALL BE IN ACCORDANCE WITH ACI 318-11 AND ACI 301-05. ALL SINGLE PHASE 15 AND 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS DWELLING UNITS. CONCRETE MASONRY WORK SHALL BE IN ACCORDANCE WITH ACI 530-11. 12. DIMENSIONAL LUMBER SHALL BE SOUTHERN PINE. 2 OR BETTER AND SHALL PROVIDE FOUNDATION NOTES ALLOWABLE STRESS VALUES OF 1200 PS IN BENDING FORA SINGLE MEMBER USES. 90 PSI IN HORIZONTAL SHEAR AND SHALL HAVE A MODULES ETAS1CITY OF 1600 KSI OR BETTER, AS 19. CARBON MONOXIDE DETECTORS REQUIRED WITHIN 10' OF ANY STEEPING ROOM. 2. MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE SLABS ON VAPOR BARRIER - 3/4- BEAMS AND COLUMNS - 1 1/2' FORMED CONCRETE BELOW GRADE-2- UNFORMED DETERMINED BY AN APPROVED LUMBER GRADING AGENCY. 1. FLOOR SLAB TO BE 4' THICK POURED CONCRETE SLAB WITH FIBERMESH CONCRETE BELOW GRADE-3- 13. NON -BEARING INTERIOR PARTITIONS MAY BE CONSTRUCTED OF 2x4 0 24' O.C. PLUMBING NOTES ON 0.006 VISQUEEN (OR EQUAL) ON CLEAN WELL COMPACTED FILL STUDS, WITH 1/2" GYPSUM DRYWALL EACH SIDE. ATTACH DRYWALL WITH 1' LONG 3. REINFORCING STEEL GRADE 60 (FY=60.000) ASTM A615-94. BUGLE HEAD DRYWALL SCREWS AT 12. O/C MAX. 1. ALL PLUMBING FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 405, F.B.C. 2. ALL REINFORCING STEEL TO BE GRADE 60. 4. DETAIL OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH 'THE MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION' AS PUBLISHED BY THE 14• METAL LATH OVER SHEATHING SHALL BE 3/8' V-GROVE OR DIMPLED. FASTEN TO 2. ALL PLUMBING FIXTURES SHALL MEET THE REQUIREMENTS OF TABLE 604.3, F.B.p 3. COLUMN AND WALL CENTERLINES SHALL COINCIDE WITH FOOTING CENTERLINES UNLESS CONCRETE REINFORCING STEEL INSTITUTE UNLESS NOTED OTHERWISE. SUBSTRATE AT 4' 0 /C AS FOLLOWS; OTHERWISE NOTED. CONCRETE: 3/4' LONG STUB NAILS W/ 3/B' HEAD. HORIZONTAL AND VERTICAL WOOD S. DISPOSITION OF RAIN WATER SHALL COMPLY WITH F.B.C. PLUMBING CODE CHAPTER 11. 4. FOOTING DESIGN BASED ON ASSUMED SOIL BEARING CAPACITY OF 20DO P.S.F., 5. ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SUPPORT ALL LOADS DURING CONSTRUCTION. FRAMING MEMBERS W/ NAILS OR STAPLES TO PROVIDE AT LEAST 1-3/4" PENETRATION INTO HORIZONTAL WOOD FRAMING MEMBERS, AND 3/4- PENETRATION INTO VERTICAL WOOD 4• ALL PLUMBING PENETRATIONS MUST BE A MINIMUM 10'-0- FROM ROOF JACKS. 5. FILL PLACED WITHIN 5'-C" OF THE CONSTRUCTION PERIMETER SHALL CONSIST OF CLEAN 5. CONCRETE BEAM SIZES MAY INCREASED (8- MAX.) AS REQUIRED FOR ARCHITECTURAL FRAMING MEMBERS ON VERTICAL WOOD FRAMING MEMBERS, COMMON NAILS SHALL BE BENT OVER TO ENGAGE AT LEAST THREE STRANDS OF LATH, OR BE BENT OVER A RIB 5. CONDENSATE DRAINS MUST BE A MINIMUM OF 12' OFF THE BUILDING. WELL GRADED SAND COMPACTED TO ACHIEVE A MINIMUM OF 95% MODIFIED PROCTOR ASTM D 1557. DETAILS OR FIT BLOCK COURSING, DROP BOTTOM OF TIE BEAM AS REQUIRED AT WINDOW AND WHEN RIB LATH IS INSTALLED. SHEATHING: 14 GAUGE STAPLES 1" LEG, 7/16" CROWN METAL DOOR BEAMS (28- MAX.) AND ADD 2-;i5 BARS BOTTOM IF DROP EXCEEDS 8'. MTL FRAMING SELF TAPING SCREWS 112 x 1/2' WASHER HEAD STAPLES SHALL NOT BE 6. INSTALL CHASE PIPE FOR HVAC, 6. ALL MONOUTHIC FOOTINGS HAVE BEEN CHECKED TO PREVENT THE USE OF TRANSFER USED FOR SOFFITS OR CEUNGS REINFORCEMENT AT PERIMETER. RATIONAL ANALYSIS SHALL BE SUBMITTED, BUT ONLY IF 7. DOWELS COLUMN AND WALL REINFORCING TO FOOTING WITH SAME SIZE AND NUMBER OF REQUESTED BY THE BUILDING OFFICIAL DOWELS AS VERTICAL BARS ABOVE 15. PNEUMATIC FASTENERS SYSTEM TO BE HILTI-COIL NAIL PROGRAM, TYPE TO BE CRF 112G MECHANICAL NOTES 1-1/2" LONG AND .120' DIAMETER U.N.O. _. 7. CONCRETE FOR FOUND FOUNDATIONS AND FOOTINGS SHALL BE 2500 PSI MIN. B. REINFORCING STEEL SHALL BE LAPPED 48 BAR DIA. MIN. WHERE SPLICED AND SHALL BE WIRED TOGETHER. PROVIDE CORNER BARS SAME SIZE AND NUMBER AS HORIZ BEAM 16. TRUSS MANUFACTURER SHALL DESIGN TRUSSES TO COMPLY WITH ALL SUPERIMPOSED 1. ALL HEATING, AIR CONDITIONING, REFRIGERATION AND VENTILATION EQUIPMENT SHALL 8. DAMAGE PROBABILITIES FROM TERMITE INFESTATION IS VERY HEAVY PER TABLE R301.2(1). REINFORCING AT EACH FACE LAP 48 BAR DIAL MIN. WIND LOADS PER F.B.C. 2020 7TH EDITION & ASCE 7-16. CONFORM TO THE REQUIREMENTS SET FORTH IN THE 'FLORIDA BUILDING CODE MECHANICAL' !1." PLACING DRAWINGS ON BAR LISTS SHALL CONFORM TO ACTS 'MANUAL OF STANDARD AND CHAPTER 28 OF THE FLORIDA BUILDING CODE. PRACTICE FOR DETAIUNG REINFORCED CONCRETE CONSTRUCTION AS PUBUSHED BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLESS STEEL NOTES NOTED OTHERWISE. GARAGE NOTES 10. DAMAGE PROBABILITIES FROM WEATHERING IS NEGLIGIBLE PER FBC TABLE R301.2(1). 1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC 'SPECIFICATION FOR THE DESIGN 1 OFuNINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOD WOOD PROPOSED SINGLE FAMILY RESIDENCE BY: GRENADINE CLUB LOT 61 MEADOWOOD COPYRIGHT 2021 TYPICAL "MI" WINDOWS N ® Nto H Co E [E N 18�" 3g° 52d„ co 25�. SH 15 SH 25 SH 35 SH H35 M.O. 20 1/8' M.O. 38' M.O. 54 1/8' M.O. 27 1/2- 1x, 2x, OR 5/4 BOARD 1x, 2x, OR 5/4 BOARD E 11 P.T. WOOD BUCK P.T. WOOD BUCK ®' 38" 70" 38" 1, / SH 35 \`� • M 4`to J s TYP. BAY WINDOW FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS' 2005 EDITION. MATERIALS UOORS NOT LESS THAN V" (35 MM) THICK, SOUD OR HONEYCOMB CORE STEEL DOORS NOT SHALL CONFORM TO THE APPLICABLE ASTM SPECIFICATION AS FOLLOWS. SHAPES, PLATES A-3f LESS THAN V' (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. BOLTS - A 307-00 TUBULAR - A500-01a GRADE B (42 KSI) 2 DUCTS IN GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE 2. WELDED CONSTRUCTION SHALL CONFORM TO THE AMERICAN WELDING SOCIETY 'STRUCTURAL DWELUNG FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) WELDING CODE". ELECTRODES FOR FIELD AND SHOP WELDS SHALL BE A.W.S. A5.1 E70XX. SHEET STEEL OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE. 3. THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LOAD SCHEDULE LESS THAN ? (12.7 MM) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. LOCAT10N LYE LEM RART'N TOTAL GROUND FLOOR 40 50 10 100 SECOND FLOOR 40 15 10 65 ROOF 30 18 0 48 ATTIC 20 10 0 30 WIND: ULTIMATE WIND SPEED = 160 m.p.h. BUILDING RISK CATEGORY = II BUILDING DESIGN AS ENCLOSED EXPOSURE = C ROOF DEAD LOAD FOR WIND DESIGN TAKEN AT 10 p.s.f. NOTE: THIS STRUCTURE IS DESIGNED IN ACCORDANCE WITH CHAPTER 16 OF THE FLORIDA BUILDING CODE AND ASCE 7-16. DESIGN PRESSURES FOR EXTERIOR DOORS AND WINDOWS ARE NOTED ON THE ELEVATIONS. WINDOW AND DOOR MANUFACTURERS SHALL MULTIPLY THE GIVEN DESIGN PRESSURES BY THE APPROPRIATE FACTORS TO OBTAIN TEST PRESSURES, THERMA TRU EXTERIOR DOORS / / T 2x P.T. Lu WOOD BUCK SHOWN TYP. M.O. 35 1/4' W M.O. 37 1/4' W M.D 41 1/4" W M.O. 55 1/2" W M.O. 78 1/2" W X 98 1/2- H X 98 1/2' H X 98 1/2' H X 98 1/2' H X 98 1/2- H EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB EDGE OF SLAB Fat EDGE OF SLAB 2680 EXT DR 2880 EXT DR 3080 EXT DR 3080 EXT DR W/ 12" SIDELITE PR 3080 DR (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) (OUT SWING) DOOR INSTALLATION NOTE: DOOR BUCKS USED MAY BE 24, 5/4" BOARD OR tx6. CONCRETE SCREWS USED TO SECURE THE DOOR FRAMES TO THE OPENINGS MAY BE ANGLED SUGHTLY WITHOUT APPRECIABLE LOSS IN RESISTANCE. ALL FASTENERS SHALL BE OF THE SIZE, LENGTH AND SPACING AS REQUIRED IN THE PRODUCT APPROVAL INSTALLATION PROCEDURES SYMBOLS LEGEND # DETAIL SCALE DETAIL SCALE DWG. SECTION oWG. SCALE SECTION ow . SCALE INTERIOR ELEV. SCALE 6# BEAM LABEL A# REVISION Fly NORTH ARROW ,i'-- BREAK UNE o r �• r scAIF 1 GRAPHIC SCALE DRAWING INDEX C-1 COVER SHEET A-1 FOUNDATION PUN A-2 FLOOR PLAN A-3 ELEVATIONS A-4 SECTIONS A-5 STRUCTURAL PLAN A-6 TRUSS PLAN E-1 ELECTRICAL PLAN M-1 MECHANICAL PLAN 1 2C6 3 07%,0 4 DMC. 2 INTERIOR ELEVATION 3 )PI C# COLUMN LABEL FOOTING LABEL V a1_zl: POT SHELF HEIGHT AS NOTED DROPPED SOFFIT HEIGHT AS NOTED ARCHED OPENING SEE PLAN OR ELEV. MASONRY CONSTRUCTION TYPICAL r ■■ GROUT FILLED E C lLel FOUNDATION PLAN NON -BEARING FRAME CONSTRUCTION BEARING FRAME CONSTRUCTION ELEV BEAM HEIGHT CHANGE At\O`-O" FIN. Fl- SLAB FLOOR E TI®N W 9 W N _j ^ $ w J y w < d z LL Z y F w � � N J cgs o ❑ Z`o O d H O S c O LID w CL CL o S Cn a N`a7 QA a.-. tCo S O r0 3 w (D Vi he C 01 v1 ++ C -� CO O- p_ .f.3 0 tco (a oa a�i ' +� Cn Lu O MU O O �i co2: O d O w F- Q c C (n N O O p (3 H , a.=. Y O $ tic o� C 2r =1 J z O b In 0' O J Co R LID ce ce O Lu le Aft J LL_ Z p 0 U Lu 0 =:) ~ 111 i X: U) COVER SHEET C-1 Mw = 61 PROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03.05.21 CALCULATIONS TOTAL U/A 1832 S. F. PORCH 121 S. F. COVERED PATIO 122 S. F. GARAGE 583 S. F. TOTAL AREA 2658 S.F. DELETE CERAMIC SOAP DISH IN MASTER BATH ONL' IMPACT / LOW E GLAZING AT WINDOWS AND SLIDING GLASS DOORS R-40 BLOWN -IN INSULATION AT ALL A/C ARE/ ADDITIONAL NOTES: 1. STANDARD HOLLOW CORE RAISED PANEL DOORS. 2. TILE TO 8'-0° IN MASTER SHOWER AND 8'-0" IN OTHER LOCATIONS. 3. FIBERGLASS BOARD OR DUR-O-ROCK TO 8'-0° A.F.F. OR SOFFIT AROUND TUBS/SHOWERS AND TO 4'-0" A.F.F. ® MARBLE TUBS 4. ROUNDED CORNERS AT ALL LOCATIONS EXCEPT CLOSETS, SLIDERS, WINDOWS, DOORS, VERTICAL EDGES OF CEILINGS OR AS NOTED ON PLANS. 5. KNOCKDOWN CEILING TEXTURE AND ORANGE PEEL WALL TEXTURE. 6. R-40 BLOWN -IN INSULATION AT ALL A/C AREAS 7. IMPACT WINDOWS. GARAGE CEILING (4) 20 METAL STUD FLOOR RO CEILNG GARAGE FLOOR z Q J J L�. W LLI V) FINISHED CEILING 2x TWD BLOCKIN EACH SIDE OF I FOR MOUNTING 2x MTL STUD! TYP. FINISHED FLOOR TYP. MEDICINE CABINET WASHER I DOER 28-1/27 SPACE DRYER VENT LOCATION FRONT VIEW 0 e DRYER VENT — - In 12° AC CONC. PAD DETAIL N.T.S. CEILING TYPICAL FRAMING ® 16° O.C. — - FINISHED FLOOR LLI 3C4 ® 7-U X: LLI ❑� w L 16' ELECT. PANEL / CHASE SOAP NICHE TEMP FRAMELESS GL W/ CUPS 1/2" WALL CAPS MTL FRAMING ----\ KNEEWALL W/ DRYWALL FINISH THIS SIDE PT 2X SILL PLATE -� W/ 1/40. TAPC�ONS & FENDER WASHgR TO SLAB TOP OF KNEEWALL W/ PT 2X TOP PLATE & 1/2° PLYWD & 1/2' NON ASBESTO FIBER CEMENT BACKER BOARD KNEEWALL W/ NON ASBESTOS FIBER CEMENT BACKER BOARD ON SHOWER/TUB SIDE L � o ROMAN SHWR M LLLLL 1 0 LLLLLL TYP. KNEE WALL SECTION 1/2" = 1 -0" Ld s W w J a W Z z o z J w < w _ LL J a O F z0 O`a N � o a �� 0 0 a0 0' tea``-i � o ° a � m x _ O c whe 3 •NC7� U vi o, �n -vw C � -g G Cc m p �o (n o E i n � O d N C• o = i F- M (% O1 C C '+Q= C CO U' 2 d ��vppi {cu N 11, REVIEWED FOR CODE COMPLIANC . ' ST. LUCIE CO i a BOCC �i FILE COPY 2 z O 9 b r2 V1 o�o LL m VI 2 W ce 0 1 s co 0 mr • : s Ln y u_ Z 0 O O O U W Flo 0 u � J O W Ln = V-O" U.N.O. FLOOR PLAN A-2 MW m 61 Vr %%ofmMmm 11orV1Nncx:)nr* SDI W,,0510l 44a�3ai sa•" W:virespi otnr Product Submittal Sheet virrylcarp.com 3015PN r9:h Place f's55dr I?4: �I erkwestr: ;].eooh Bjildr g Systems LL') !t1ian I,..ida 33155 s 105 'Ie 1 ,6 PROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03-05-21 Soffit Vents (Cane Piece) ; Continuous one-piece Soffit Vent with reinforcing rib to key Into stucco &amp;'plaster. t� A {r: 5`'�-mow CS58300V 5/8" 3"witle vent (one piece) 5 overall wltltn perforated flanges n 15 i Soffit Vent, Cantlnuousone-piece Soffit Ventwfih reiribrcing nbto keyinto stucco&amp;plaster. Vent Clips are providedto connect Soffit Vent and to a uie, in alignment. Ventarea 'IS square inches per lineal. ft. Caulk all irate mecti ons,, poll joints, r nos and corners at time of mstallae on. MENEM= Product Submittal Sheet VINYU�xloIinp A Wwala p moyloorp Dom � K'J a r ' a; I 0 5477..6464 oarkiliviiiiialsw4oliseyyRA rjdrrebarn Lm.oh Buriong Syetsms l=�C Mlan 'wera3.l 65 t 77 4108 Mid Wall (M Style) Control Joint Designed to relieve stress and assist In controlling cracks °n exterior wall finish Intersections of Ts '> available. DIN 3 1578-50UL r/8'k1)2" 3 T.' snlldflan ae 'I-'J= peforated Flange - Mld Wall Control Joints -Uesldned to relieve access and assist in controlling cracks in exterior wall nnl'ch. Interaeot Dns n' 1 s available. US Patent Number 7,757,kM Caulk all intersections, butt Joints, ends and corners at time of installation: ATTIC VENT CALCULATION: I IN) ROOF AREA CALCULATED ® 2658 (SQ.FT.) x 144 ee 3OZ752 SO IN. / 150 = 2,552 SQ, IN. REQUIRED NET VENT AREA 15 SO IN. PER LINEAR FT. 171 LF) VENT - 2,565 SO. IN. TOTAL NOTE: CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF VENTS FLAT CONCRETE 71LE 901 FELT SELF-ADHESIVE UNDERLAYMENT OVER 301 FELT TIN TAGGED --\ TO EXT. GRADE PLYWD. SHEATHING \ (SEE DIAPHRAGM SCHEDULE FOR TYPE & NAILING PATTERN) PRE-ENG. WOOD ROOF TRUSSES 024- 01C TYPICAL W/APPROVED ill TRUSS ANCHORS EA. END j> SEE PLAN/ ELEV. GALV. MR. DRIP — ON IX2 P.T. 2xB PAINTED TEXTURED —� SPRUCE FASCIA CEMEN77TOUS FINISH ON METAL LATH W/ 3' CON77NUOUS VENIING ON ALL SIDES (TRUSS CO. TO PROVIDE FLAT SOFFIT) MEDIUM TEXTURE DECORATIVE CEMENTITOUS FINISH OVER 8' CONC. BLOCK NOT TO EXCEED 5/8" THICKNESS R 4.1 Fl-FDIL BETWEEN STUDS I$ 0'-0" FIN. FL SLAB INSULATION PER ENERGY CALL. y RAT RUNS PER TRUSS Ill 8" DRYWALL OR 1/2" "TOUGHROCK" R EQUAL) APPLIED TO NDERSIDE OF TRUSSES RE STOP ONT 8z16' MASONRY BOND BEAM fiEXTERIOR /115 CONT. TOP & BOT. - FILL W/ CONC. ON METAL POUR STOP 2' DRYWALL 2 P.T FURRING ® 24" 0/C BLOCK WALL TO BE WOOD BASE MONO. CONC. FOOTING SEE FOUNDATION PLAN FOR NOTES & DETAILS •,Al I I IiLlf TTT- TYPICAL WALL SECTION SCALE 3/4" = 1 0' N3NO1 'WHIN 15 DECORATIVE STUCCO LOWER I II I I I JJJ--- 5/8' THICK MEDIUM TEXTURE DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. OD.P.= +31.9 PSF -34.7 PSF I I I I I MEDIUM TEXTURE DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. CONIC ROOF TILE, Ti I I I I I 9-4" T.O.B.B_ ®® u 8886 mEffli.I SMOOTH STUCCO BANDS, TYP. OD.P.= +31.9 PSF D.P.= +31.9 PSF 34.7 PSF 0-34.7 PSF V-0" FIN. FL. SLAB D.P.= +31.9 PSF -34.7 PSF FRONT ELEVATION ARTI A rM H D.P.= +28.4 PSF MEDIUM TEXTURE -31.2 PSF DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. 0. I I II \ I I 9'-4" T.O.B.B. - I v= ar-r r�r - - - I 0'-On FIN. FL SLAB ii + ------ REAR ELEVATION - ARTISAN O D34.70 PSF P LEFT ELEVATION - ARTISAN ui W a. Z td J W Z Z � y W N Z t Oa Cn is o CA L C 6 an cn -0 m y W Q O v a0 2 o = p1 Q- .0 w aL-+ _ -0 C M c to 0 m 8 +� +� a, W Fa0 G E Q 0 QJ s= an 0 o d a� `y Ne Z L t/f REVIEWED F® CODE COMPLIAN ST. LUCIE C d'r0I T � — - 10'-B" T.O.B.B. 9'-4' T.O.B.B Ell r� V -0'-0' FIN. FL. SLAB t Z b 2 LU 2 o�C W E Q LU fd} a E o i u -C O C — cC:) 00 C:) a) �- rail LC) N CV d J LL M O o � LU ,--� 0 U d � J OJ LU (~l� = V-Orr U.N.O. ELEVATIONS A-3 T i In PROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03-05-21 12 METAL ROOF OR CONC. ROOF TILES, TYP. 6� a=4.0" I I I I I I I I I I I I 10'-8" T.O.B.B. AN 9'-4" T.O.B.B. W a e J r ui J y � n W % W LL LL j uj Z U z 3 N~� mElEl z J 2m 0'_0" FIN. FL. o Z m m` Oa OD.P.= +28.4 PSF MEDIUM TEXTURE RIGHT ELEVATION - ARTISAN -31.2 PSF DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. cn c o co rn c v Lu r a a c Z o O O rnw Q O cu a.-. r`o aci ca = a c aL+Ln "CO ATTACHED TO METAL LATH j O -9 o � Ll i2 ED TO UNDERSIDE OF TRUSSES E2 v +'3 v STUCCO ATTACHED TO METAL LATH aF RAT RUNS PER TRUSS MAN'F. ro w ATTACHED TO UNDERSIDE OF TRUSSES c (MAX. 8' O.C) 12 RAT RUNS PER TRUSS MAN'F. •Q @ L c c c w v a o (MAX. 8' O.C) CL o m w 2 6 0�' �`��' cLn oLu f C) p —`°u m Ln PRE ENGINEERED WD. TRUSSES � �, `� _ V) cn = +� = O O Lu 24" 0/C TYPICAL O g- o z w Lu v CL w .- 9'-4" T.O.B.B_ 0 ' COVERD � _ PATIO P GREAT ROOM FOYER COV" " ®El ®®®®®® Lo PORCH ®�®®®®®® Lo Lo o SLOPE SLOPE u -c F� ---i �� 0'-0" FIN. FL SLAB Co ------ ® c W c — SECTION A -A - ARTISAN :; cn o saw I0 N lzo3 d REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY � BOCC V TYPI CAL I N STALLATI O N r�W.,, J WINDOW ASSEMBLY wCONTRACTOR TO APPLY TO ALL SIDES DF MASONRY OPENING INCLUDING HEADER AND JAMBS PER FBC 2020 R703.4 FASTENERS AS REQUIRED LIQUID APPLIED FLEXIBLE CONCRETE FiM Z CAULK+CIR BY WINDOW MANUFACTURER FLASHING WATER PROOF PRODUCT TO �V [] � MARBLE SILL MEET AAMA 714 ^AP APPLY PRODUCT DIRECTLY TO CLEAN CM• y ® O CONCRETE SUBSTRATE PER MANUF. SPEC �'�� W CAULK SEAM AT lF,i/1 .�' W .: n. WINDOW INSTALLATI .--1 'MORTA e. GROUT J a e .:. c O G V% �,. �'. uj ° .. ° • ° .. SET SILL IN FULL DRYWALL �,. •'•• • ..,e MORTAR BED AND HEAD JOINT ;. :'<' •.: .:.: ::.:::: rl ::. .. :i STUCCO DR ".p DECORATIVE 1/4" = 1'-D" U.N.O. • CEMENTITIOUS SECTIONS COATING 3/4' FURRING TO MASONRY WALL ° " 8' C.M.U. ELEVATIONS NOTE: IN THE EVENT THAT THE R.O. IS LAID OUR LARGER THAN THE PROPOSED OPENING ON PLANS. \ A-4 THE CONTRACTOR SHALL BE ALLOWED TO SHIM THE OPENING, USING A COMBINATION OF 2x & 1x PRESSURE TREATED LUMBER. THE FRAMING SHOULD BE SECURED TO THE BLOCK USING THE PROPER TAPCON LENGTH, DIAMETER & SPACING FOR MINIMAL EMBED REQUIRED AS NOTED PER PLAN. PRECAST SILL DETAIL CONCRETE WATER PROOFING APPLICATION MW 1 I F OD.36.3 PSF.4 PSF I OD.P: +33.4PSF 6'-0" -36.3 PSF I I ,,,` ..I�,...,..... , PROVIDE CEMENTITOUS FINISH PRIOR TO L D.P= +31,9 PSF O -34.7 PSF METER INSTALL I I ix4 P.T. BUCK SET IN STUCCO FINISH CONC. OR MASONRY SEALANT AND NAILED W/1-1/2' CASE HARDEN PERIMETER CAULKING 2x6 P.T. BUCK RIPPED COIL NAILS AT 12" 0/C. CONC. OR MASONRY TO WIDTH OF DOOR JAM MAX. ix4 P.T. BUCK SET IN SET 1N SEALANT FASTEN CONC. OR MASONRY SEALANT AND NAILED Wf 1/4' D4L x 3-1/4' W/i-i/2' CASE HARDEN TAPCONS 3` FROM EE. Oo COIL NAILS AT 12" 0/C. .�Qo o AND 11' 0/C MAX. o Q a MAX. 00 . DOOR TRIM DRYWALL BOARD DRYWALV. L WARD DOOR FRAME CAULKING CAULKING FASTEN TO BUCK W/ •` ALUMINUM FRAME (2) �'6 GALV. x 2" FASTEN TO BUCK W/ DOOR FRAME SCREWS ®2'-0" 0/C CONC. COLUMN 3/16 z2-i/2' TAPCON FASTEN TO BUCK W/ DOOR TRIM WEATHER STRIPPING SCREWS ®12' 0/C SCREWS ®12'-0? 0/C PERIMETER SEALANT BY DOOR MANE. PERIMETER SEALANT STUCCO FINISH GARAGE DOOR STUCCO FINISH GALV. STL. VERT. TRACK HEAD DETAIL (WINDOW) JAMB/HEAD DETAIL (S.G.D.) HEAD/JAMB DETAIL (DOOR) BY MANE. FASTENED TO TRACK BRACKETS W/ ALUMINUM FRAME 1/4'-20x1/2' CARRIAGE FASTEN TO BUCK W/ DOOR THRESHOLD SET BOLTS &LOCK NUTS GALL! SR. TRACK 3/16"x2 1/2" TAPCON SCREWS @ 12" 0/C ALUMINUM FRAME � SECURE FRAME TO SILL 1N BED OF CAULK & FASTENED TO SILL W/ BRACKETS FASTENED PERIMETER SEALANT WITH SILICONE �8 x 1 1/2" SCREWS ® 18" 0/C TO WOOD JAMB W/ 3/16"xi-i/4' LAG SCREWS "�— STUCCO FINISH CONC. OR MASONRY CAULKING � � DOOR FRAME FASTEN TO SILL W/ PERIMETER CAULKING � 2xB P.T. ATTACHED TO MMIU. S METHOD OF COLUMN W/ 5 WEDGE ANCHORS ®2'-0` 0/C VERT. APP EVA�q. � 1x4 P.T. BUCK SET IN SEALANT AND NAILED W/1-1/2" CASE HARDENE � o:... `o Oa a �O � aQu #6 x 2" SCREWS ®2 -0' 0/C FLOOR COVERING S W COffPYE7E INSIRUCIIDNS (6" MAX. FROM ENDS) AND COIL NAILS AT 12" 0/C. FLOOR COVERING 2' FROM INSIDE EDGE OF 2X JAMB DETAIL (GARAGE DOOR)DRYWALL MAX. B04RD � PRECAST OR POURED SILL°CAULKING 411k o CONC. FLOOR SLAB IF GARAGE DOOR VERTICAL REINFORCEMENT PERIMETER CAULKING PERIMETER CAULKING REQUIRED, ADD (1) �" A.B. TO EACH SIDE OF THE GROUT BED STUCCO FINISH BRACKET THRU THE HORIZONTAL 2X P.T. HEADER, CONCRETE SLAB 4' MIN. EMBED MAX. 6- FROM EACH SIDE OF THE BRACKET. JAMB DETAIL (WINDOW) SILL DETAIL (WINDOW) SILL DETAIL (S.G.D.) SILL DETAIL (DOOR) PROJECT LOG ISSUED FOR PRE -CON 02.11.21' ISSUED FOR PERMIT 03-05-21 ENG. AND APPROVED WOOD TRUSSES SEE ENG'D d: APPR. GIRDER TYP. WALL SECTION FOR ACTUAL HEEL TRUSSES MEET EACH AND OVERHANG CONDITIONS OTHER 0 90 DEG. ANGLE OVER COL (SEE SEE TRUSS CONNECTOR NOTE' FRAMING PLAN) INSTALL PER. MFR. SPECIFICATIONS r BLOCK BY TRUSS MANF. SEE PLAN] 4x4 WD. POST (SEE COL SCHED.) a' wa 4'-0° MAX. SIMPSON CCTQ.—SDS �r ° COL. CAP. SCREW PER MANUF. SPECS. CONT. MASONRY BOND BEAM CONL POUR STOP Ns VERIFY WIDTH W/ 8' CHU WALL TRUSS MFG PRIOR TO ORDERING FROM SIMPSON CCTa-SDS2.5 , 'TOTAL UPLIFT 5,315# • ° A5 CONNECTION DETAIL A5 CONNECTION DETAIL ��• PRE—ENG. WOOD TRUSSES SEE TYP. WALL SECTION FOR ACTUAL HEEL AND O.H. CONDITIONS USP HOPT2 OR HDPTD FASTEN TO WALL W/NAILS PER SCHEDULE AS READ. FRAME BEARING WALL ELEV. —STRAP DEL. TOP PLATE TO STUDS W/ "USP' SPTH 4, 5, OR 8 U-STRAP TOP PLATE AND DOWN EACH SIDE W/ (6) 10d NNLS (TYPICAL) W/ WOOD STUDS 0 16. O/C (PER PI —SOLID BLOCKING 0 4'-0' O/C VERT. MAX. — STRAP BOTTOM PLATE TO STUDS W/ "USP" SPTH 4, 6, OR 8 U-STRAP BOTTOM PLATE AND UP EACH SIDE W/ (6) 10d NAILS (TYPICAL) — 5/8' WEDGE ANCHORS 0 24" O/C AND 6' MAX. FROM OPENINGS W/3'x3'xt/4' STEEL WASHERS EMBED 4' MIN. FLOOR SLAB SECTION ALLOWABLE UPLIFT LOADS FASTENER TOTAL FASTENERS SIZE 21 81 10 11 8d =1 4401 6601 8801 11001 1320 10d 2651 5351 8001 10651 IJJJj 1500 A5 CONNECTION DETAIL (3) 160 TYP. � 2x4 DIAGONAL BRACE RE 0 4'-0' 0/C, TYP. 2x4 LATERAL I (p) 0 4'-0" 0/C, Fif 1TRUS -1 GABEL END BLOCKING TRUSS TOP CHORD SEE PLAN NAIL SHEATHING TO UDDER EDGE PER DIAPHRAGM SCHEDULE CONT. FASCIA BOARD (SEE WALL SECTION) 2X4 LADDER AT 16' 0/C L 2X4 MAX. � UDDER EDGE W/ (2) 16d NAILS 8' O.C. TO TOP CHORD OF TRUSS WALL SWIHING NAIL PER SCHEDULE GABLE END FASTEN TO TRUSS. SEE TRUSS ENGINEERING DETAILS FOR TRUSS CONNECTION REINFORCE VERTICAL MEMBERS OF GABLE END TRUSS W/2x4 TEE —BRACE AT EA VERT. NAIL W/16d NAILS 0 8' 0/C PLAN NEW AT TEE BRACE A5 CONNECTION DETAIL CONE. CONC. OR MASONRY TIE BEAM SEE 71E BEAM SCHEDULE ROOF SHEATHING NAIL PER SCHEDULE CONT. FASCIA BOARD (SEE WALL SECTION) NAIL TO TO LADDER W/ 16d 0 8' O/C (3J i6D TM LADDER FOR O.H. 0 12° 0/C 18 CONT. 2x4 LADDER PLATE ANCHORED TO GE TRUSS W/ 16d NAILS 0 8' O/C MAX. 20 DIAGONAL BRACE RESTRNNT 0 4'-0' O/C 2 10d TYR TRUSS WALL SHEATHING NAIL PER SCHEDULE GABLE END FASTEN TO SLEEPER W/ 16d NAILS REINFORCE VERTICAL MEMBERS 0 4° O/C TYPICAL OF G48LE END TRUSS W/2x4 T—BRACE AT EA VERT. CONT. 2X4 SLEEPER FASTEN TO BEAM W/ HILTI NAIL w/16d NAILS 0 8. 0/C XDNI 2-5/8" LG. 0 6° 0/C USP TA24R EMBEDDED STRAP W/ (4) 16d NAILS ATA 0 EA TRUSS VERT. WEB (24' 0/C) — CONT. CONC. OR MASONRY TIE BEAM SEE TIE 3 BEAM SCHEDULE CONNECTION DETAIL A5 —20 LATERAL BRACING 04'-D' O/C 04 WOOD POST SEE FRAMING PLAN .— (2) 5/8' 014. BOLTS THROUGH POST 13IMPSON H058' HOLD DOWN EA SIDE OF POST OR APPROVED EQUAL — (1) 3/4' DIA. WEDGE ANCHOR 4" MIN. EMBED. a EA. HOLD DOWN 6 CONNECTION DETAIL A5 (!A5) Q 11 iuf O m O LINTEL BEAM SCHEDULE 1B/FT LINTEL LENGTH ALLOWED LOAD APPLIED LOAD UPLIFT ALLOWED APPLIED UPLIFTLINTEL SPECIFICATION 1 17'-4' 2047 220 872 78 8F34-lB/lT 2 4'-0" 6113 0 3079 0 8F14-1B/lT 3 5'-4- 5365 0 2290 0 8F16-lB/lT 4 7'-6° 2661 130 1634 97 8F16-lB/lT 5 7'-6- 2661 120 1 1634 90 8F16-18/1T 6 7'-6- 2661 355 1634 247 8F16-tB/lT 7 4'-0' 6113 1270 3079 435 8F16-lB/lT 8 3'-6" 11809 1253 7636 436 8F32-1B/lT 9 3'-6- 11809 1253 7636 436 8F32-lB/lT 10 - 7'-6° 6472 0 3508 0 8F32-1B/lT 11 13'-4" 2883 0 1321 0 8F32-10/lT 12 10'-8' 1533 423 914 275 8F16-181T 13 9'-4" 1843 210 1133 82 8F16-lB/lT 14 14'-8' 1370 217 519 75 8F16-lS/lT 15 7'-6- 2661 271 1634 95 8F16-lB/lT 16 7'-6- 2661 946 1634 330 6F16-181T 17 3'-6- 6113 1 1841 3547 650 8F16-tB 1T 18 5'-4° 5365 946 2290 330 8F16-1B 1T 19 7'-6' 8615 220 5478 78 8F34-lB/lT 20 4'-0' 6113 1270 3079 435 8F16-lB/lT 21 4'-0' 6113 1270 3079 435 8F16-lB/lT O 0 w O A4 �i�wnw J F = FILLED WITH GROUT / U = UNFILLEDtE QUANTITY OF /5 REBAR AT BOTTOM OF LINTEL CAVITY n o W a m W r J a LLJ w W Z 7 z w Ly y � w a J Z 0 a 0 c o an F cnN, = T jLu aC C a O 0 CL s toLi 0 @ ai '> 0 — 0 o Q lr3 o to to +.. ++ m ov Ev w as W O 0 — c CL as i9FE0 ul uj-0 Z 8 a.0 v `O -0 N tn r . va ■ CODE COMI 3LIANCE ST. LUCIB COUNTY BOC pq W !� f ICI J LL #5 REBAR AT TOP 1�--I H MIN. (1) REQ'D 1-1/2" Z 4• • CLEAR O A a C.M.U. � W _ 0 u � i 1 8 F 16 -1 B/ 1 T � ZLOT GROUT #5 REBAR REINFORCING 0 PROVIDED IN UNTEL (VARIES) NOMINAL HEIGHT QUANTITY OF �5 LNOMINAL WIDTH REBAR AT TOP 7-5 8' W. TYP. 0 WALLS 8U8 8F16-09/1T 8F16—lB/lT 8F24-013/lT 81724-1 /1T 0-1B/1 J W J. 1/4" = 1'-O" U.N.O. STRUCTURAL RAL A-5 T RING -SHANK NAILS TO HAVE THE FOLLOWING DIMENSIONS. 1. 0.113 INCH NOMINAL SHANK DIAMETER 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER 3. 16 TO 20 RINGS PER INCH 4. 0.280 INCH FULL ROUND HEAD DIAMETER 5. 2 INCH NAIL LENGTH DIAPHRAGM SCHEDULE (FASTENING REQUIREMENTS PER R803.2.3.1) DIAPHRAGM NAILING DIAPHRAGM ZONE 1 ZONE 2 ZONE 3 PANEL FRAMING BOUNDARIES EDGE INTER. EDGE INTER. EDGE INTER. LOCA71ON PANEL GRADE 7HICKNESS SPACING REMARKS ROOF APA R47ED SHEATHING 8d RING- 6d RING- 8d RING- 8d RING- 8d RING- 8d RING- 8d RING - EXPOSURE 1, OR EQUAL SPAN RATING 40120 19132 24' 0/C MAX. SHANK 6' 0 C SHANK 6' DIG SHANK 6' 0 C SHANK 6' DIG SHANK 6" 0 C SHANK 4' 0 C SHANK 4' 0 C BLOCKED AS SHOWN ON PLAN EXT. WALL APA RATED SHEATHING EXPOSURE I, OR EQUAL SPAN RA77NG 40120 19132 16' O/C MAX. 8d RING- SHANK 4' 0 C 6d RING- SHANK 4' 0 C 8d RING- SHANK 6' 0 C MAL CORNER STUDS AT 4' OIC MAX. TYPICAL LOCK FREE EDGES INT. WALL APA RATED SHEATHING EXPOSURE I, OR EQUAL SPAN RATING 32 16 15132 16' 0/C MAX. 8d RING- SHANK 6' 0 C 8d RING- SHANK 6' 0 C 8d RING- SHANK 12' 0 C LOCK FREE rFnrFq ALL WOOD TO WOOD CONNECTIONS SHALL BE USP HTW20 TRUSS CONNECTOR SCHEDULE FASTENERS PER STRAP ALLOWABLE UPLIFT PARALLEL LOAD (F2) PERPEND. LG40 (F1) MARK USP CONNECTOR TRUSS 71E-BEAM OR WALL SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP TC-1 TA12 5 10d x 1-1 2' - 990 j 1980 1 335 1 670 1 245 4911 TC-2 TA14 (7). 10d x 1-112' - 1205 1 2410 1 335 1 670 j 2451 490 TC-3 NTWM16 8 10d x 1-1 2' 4 1 4" x 1-3 4' WAR 1225 1 1225 1 - 1225 - IC-4 HTA16 9) 10d x 1-112' - 1870 1 2430 1 7101 13101 270 1 1 15 IC-5 HTW20 20 10d x 1-1 2 24 10d x 1-1 2' 1530 1- - - - - 1) ALLOWABLE LOADS ARE BASED ON USP CATALOG 2015-16. 2) BLDR MAY USE LONGER SIRAPS OF SAME TYPE SPECIFIED. 3) USE GALVANIZED NAILS OR WOOD SCREWS AS SPECIFIED BY MANUFACTURER. 4) TAPCONS SHOULD BE LOCATED AT THE FARTHEST POINT FROM THE TOP OF THE BEAM. Hatch • • CRICKET9'-4" WALL HEIGHT 10'-8" WALL HEIGHT +'+ ] . . . D. NOTE: THIS TYPICAL DETAIL TO BE USED WHEN CONDITIONS MAY OCCUR WHEREVER THE VERTICAL EXTERIOR MEETS THE ROOF TYP. ROOF FLASHING DETAIL N.T.S. rom9a Moisture Barr not shown r 1t5 rebar min. Erf R£F S R!( d 4d•Lakall�a3t nMdl 1 � J h�axaN Leeb @I �pLva3s 6'SP/6PF91P1 Na 1�i __ Tw.+&W. "Po 11 f, �o �r fib, >� „1, NV n TYP. MISSED STRAP DETAIL NOTE: TRUSS LOADS HIGHER THAN CHART PROVIDED WILL NEED APPROVAL LETTER NOTE: THIS TYPICAL DETAIL TO BE USED WHERE CONDITIONS MAY OCCUR BASED ON TRUSS DESIGN AND FIELD CONDITIONS it TyP• 1 TYP. 1 TYP. RIDGE CAP & ROOF MEMBRANE 2x RIDGE BOARD (2) SIMPSON H10 CLIPS ON 1 SIDE OF TRUSS STAGG. & ATTACHED TO 2x6 CATS 0 24" O/C BETWEEN TRUSS RUN PRE ENGINEERED ROOF TRUSSES SEE FRAMING PLAN FIELD FRAMED RIDGE DETAIL o; EDGESTRIPDEFINED �ASMTHE LESSER OF 110% ` OR 40% OFOHE1GOHf H OBUT NIOT LEFSS UTHAN 4% OF LEAST HORIZONTAL DIMENSION OF BUILDING AND _ AT LEAST 3 FT. ��----- `. O NOTE: SEE DIAPHRAGM U U SCHEDULE FOR ROOF Y ZONE NAILING -1 --- REQUIREMENTS. ROOF ZONE DIAGRAM PROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03-05-21 W 0 W r u n Z W � Z w O y LL w � �Qrnj�j J d r g z = a O a 0 �is o c 0 0, � fsf= w x �� s �0 f0 x v Co m fn z� C7 �i c .0 fn ` c = c E v o E E�o�� E a a0 QJ o ~o N c f c 00 _ he O 8 m C z W 70 kn i—1 Fn F1 =1 TRUSS PLAN A-b T 2 z 0 fY 0 UL m En z 2 LU ce 0 LU J ALL r Z Q W i—f C.i J Ln ',MW-61 PROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03-05-21 ELECTRICAL SYMBOLS NEST DUPLEX RECEPTACLE SWITCH TELEVISION JACK e DETECTOR ® REYEBALLECESS 12' A.F.F. SINGLE POLE 4 PRE WIRED SECURITY USO �Q Q� LO DUPLEX RECEPTACLE SWITCH 220 RECEPTACLE t> FLOOD LIGHTS ® FP&M� IIB AT HOSE �3 THREE WAY V. AT 12' AFF SD SMOKE g & DISC. �D WAC DETECTOR Ilc AT 8' A9V.C�NTTER f4 FOURWAYTHERMOSTAT ® MONOXIDE DEFECTOR ® PANELER Q INTERCOM EXHAUST DUPLEX RECEPTACLE SWITCH I AT 60' AF.F. SWITCH FAN FLUSH IN FLOOR R RHEOSTAT TELEPHONE OUTLET 1:1J DISCONNECT F L EXHAUST FAN DUPLEX RECEPTACLE SWITCH ® AT 12' AF.F. �Q PADDLE FAN W/ LIGHT ?GFI GROUND FAULT n DIMMER TELEPHONE OUTLET �v v� W/ OR W0/ LIGHT LV DOOR FLUSH IN FLOOR ® FLUORESCENT RELEASE DUPLEX RECEPTACLE SWITCH SPEAKER FIXTURE CLG. MNTED. Qy VOLUME TOP REC. SWITCHED K KEYED IN CLG. INCANDESCENT LIGHT I CONTROL ?DUPLEX RECEPTACLE SECURITY SPEAKER FIXTURE CEILING MNIED. QUADRUPLEX WP WATERPROOF KEYPAD WALL OUTLET INCANDESCENT LIGHT � RECEPTACLE ? DUPLEX RECEPTACLE JUNCTION SPEAKER FIXTURE WALL. MNTED. LOW VOLTAGE iiuc UNDER COUNTER BOX HOME RUN ® HI HAT TR TRANSFORMER CLG. MOUNTED O INTERCOM 4 DOOR CAT5 ® HI HAT FB FAN BOX r STATION CHIME HOME RUN VAPOR PROOF IN CLG. ELEC. PANEL "A" 200 AMP CIRC, DESCRIPTION POLE BRKR WIRE VA. I 100Y 2 AHU HEAT STRIP 2 60 6 0 9.6 2 A/C COMPRESSOR 2 40 8 0 0 1 RANGE 2 50 6 12.0 0 2 DRYER 2 30 10 5.0 0 2 WATER HEATER 2 30 10 4.5 0 1 LAUNDRY 1 20 12 1.5 0 1 MICROWAVE 1 20 12 1.5 0 1 DISHWASHER/DISPOSAL 1 20 12 1.2 0 1 REFRIGERATOR 1 20 12 1.2 0 3 SMALL APPLIANCE 1 20 12 45 0 1 BATH GFI 1 20 12 1.5 0 14 GEN, LIGHTING 1 15 14 5.5 0 135.41 9.6 1st 10,000 at 100% = 10.00 REMAINDER AT 40% = 13.44 A/C LOAD AT 65% = 6.24 TOTAL = 29.68 29,68 x 1000/240 = 123,6 AMPS CALCULATION NOTES: A. HEAT STRIP LOAD GOVERNS OVER CONDENSER UNIT LOAD. B. GENERAL LIGHTING CALCULATED 0 1.832 (SQ.FT.) x 3 (WATTS/SQ.FT.) = 5,496 / 10 (GEN.LTG.CIR.) = 550 (WATTS/EA.) C. A/C CONTRACTOR SHALL SIZE A/C UNITS. A/C UNITS SHOWN ARE FOR ELEC. CALC'S. ONLY. NOTE: ALL VANITY WALL LIGHTS TO BE 100" A.F.F. U.N.O. POWDER ROOM TO BE 86" A.F.F. IF APPLICABLE NOTE: ALL EDGE OF SWITCH PLATES TO BE NO LESS THAN 4" FROM OPENINGS K GARAGE0 60" ABV GARAGE FLOOR 72" MAX. NOTE: THERMOSTAT TO BE 62' A.F.F. AND 9" HORIZONTALLY FROM ANY CORNER OF WALL OR OPENING PER PLAN NOTE: ACCEPTABLE SMOKE do CARBON DEFECTORS TO BE INSTALLED ARE BRK SMOKE-9120B C/0—SC9120B KIDDE SMOKE-21007581 C/O 21006377—N NOTE: PROVIDE ARC —FAULT CIRCUrr INTERRUPTER PROTECTION FOR ALL RECEPTACLE AND LIGHTING OUTLETS INCLUDING SMOKE DETECTORS PER 2017 NEC 210-12 (B). Plans are Prepared for the Builder and not any Planned or Future user / Home owner of the Subject Property and any Modifications, Deletions and other Changes Authorized by GHO Homes Corporation or other GHO entity are Permissible to included, but not be limited to Electrical Design Modification, Fixture or Outlet or Circuit changed, Combinations or Changes. All Final Work shall be at a minimum Equal to Code minimums and any changes are only Permissible if Suggested and complete by a licensed Electrician so long as Applicable Codes are Met and Load Sufficient to Meet GHO's minimum Level of Service and Operation. *NOTE* — ALL ABOVE COUNTER AND ISLAND OUTLETS TO BE DECORA — ALL SWITCHES TO BE DECORA (1) SETS OF (3) /4/0 AWG. THWN IN 2 CONDUIT 200 AMP SERVICE p METER DISC, CO A ' PANEL IL 200 A 5/8' GDX 10' CU SUPPLEMENTAL GROUND ROD AND TO ONE REINFORCEING BAR IN THE FOUNDATION 20'-0' LONG MIN. ELECTRICAL RISER DIAGRAM PHOTO CELL SENSOR IN SOFFIT FILE COPY Uj a � W e PI J r V n uJ W < a_ w ui D 3 W K U n j �q i J C 0 Q z a Oa N � O c_ rn s a c T C_ En 10 n O rnt`i : C O � r`o aci t ' co S C7 Ln N c a rn 10 d 4S o m cm Oa-+ ._ ++ Ln C U)o E d E c 7 Qg O a) F- O cn > c c c c p U vi as w o Y 78 � z v ao, a LO 0 CD U C01 0 C =1 ELECTRICAL PLAN E-1 t z O b d 2 J ca z 2 En .x: ine LU J LL_ F-' z 0 W r--r J Ln MW = 61 20 KITCHEN AVV KIT L"IN co ow 2- 2. AW LAV 2- LAV Go 3- 2- 2- VIR we 17 2' SHWR 3- MASTER BATH 3- 2- LAV TUB co 2- LT 3- co we K BATH3-2 co A 30 �w m LAUNDRY 3' PLUMBING RISER DIAGRAM AHU-1 3-TON 0120-0 BEDROOM 2 10XIOX8 4 172 CFM FLEX �- OE I 5xSX5 30 CFM FOYER -1 12"x12" P.A.G. W/ 8110; fL'10xl()x7 FLEX 00 125 CFM 70 DEN ffelmo cu-1 3-TON HB TWO BAY GARAGE DO NOT SCALE PLANS TOTAL AR VOLUME CLCIC FEET - 17953.E PROJECT LOG ISSUED FOR PRE -CON 02-11-21 ISSUED FOR PERMIT 03-05-21 ui Lu Lj Lu z ry cl z 0 � :5 -5 0 2 0 fa U) It fa "&.m E f=o 2 f=o Ln-R E 8.mw 2 E w g E -8 tn. m: o t� E cro=== 0 F— 0 En ao u W E CL) 0 le 0 15 L.� to 15 cp 06 U) tn FILE C(z 0 0 C) U 3: 0 Lu u 0 Lu m: 1/4' = 1-4- U.N.O. MECHANICAL PLAN M-1 T