HomeMy WebLinkAboutAPPROVED, SITE PLAN■ 2 �"X97" ACE DOORS IN 2 OPENINGS ONLY. IEW DOORS TO BE IMPACT RESISTANT- 7FR-q MnT RFCII IIRFP7 OPENING PRODUCT DESIGN OPENING SQ. WIND PRESSURES APPROVAL PRESSURES COMMENTS NO. WDTH. HGT, FTG. ZONE POS. NEG. (N.O.A. #) POS. NEG, 1 1 72 1 96 4$.00 4 35.7 1 -39.1 20-0901.11 76.0 -76.0 LIVING ROOM - LSMI 2 1 36 96 24.00 4 37.5 1 -40.8 FL15210.7 65-0 -65.0 SIDE EXIT - SINGLE DOOR- LSMI REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS. NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS. ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 114" TAPCON SCREWS INTO CONCRETE WITH A MINIMUM 1 114" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS. LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING. EXEMPT FROM 2017 ENERGY CONSERVATION CODE SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES MEAN ROOF HEIGHT = 15 FT 6 IN FURGASON RESIDENCE 2171 S. BROCKSMiTH ROAD I DOOR REPLACEMENT PLAN FORT PIERCE, FLORIDA