HomeMy WebLinkAboutAPPROVED, SITE PLANREPLACE DOOR IN 1 OPENING ONLY
NEW DOOR TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED
OPENING
PRODUCT
DESIGN
OPENING
SQ.
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO WIDTH HGT.
FTG
ZONE
POS NEG.
[N.O.A. #)
POS. NEG
1 36 80
2000
4
36.1 -39.3
FL16708 2
65.0 65.0
FRONT ENTRY - LSMI
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 14' TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 114" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE NOT A RENOVATED BUILDING EXEMPT FROM 2020 ENERGY CONSERVATION CODE
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 10 FT 11 IN
LYNCH RESIDENCE
2403 MELON COURT
DOOR REPLACEMENT PLAN