Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
- `i pill HardieTrim° Boards .z 74) I EFFECifVE SEPTEMBER 2019, .These instructions arato bd used for Heirdit;Trimf HZIV-Boards ONLY.and.are-NOT.VALID.in-the fdllowing stdtes:AK,.UT,-ID;CO,:WY,:MT.:These-instrudftiorts are also=NOT valid in portions of WA,OR,CA,NV,AZ,NM.Enter your zip code at www.hardiezone.com to find out what zone applies to your location. ~IMPORTANT:FAILURE TO-FOLLOWJAMES-HARDIE WRITTEN INSTALLATION INSTRUCTIONS AND COMPLY--WITH APPLICABLE BUILDING CODES MAY VIOLATE LOCAL LAWS;AFFECT BUILDING ENVELOPE.PERFORMANCE.AND MAY AFFECT WARRANTY COVERAGE.FAILURE TO.COMPLY WITH.ALL.HEALTH.AND SAFETY REGULATIONS WHEN CUTTING-AND INSTALLING.THIS PRODUCT MAY RESULT IN PERSONAL INJURY,BEFORE INSTALLATION,CONFIRM YOU ARE USING THE CORRECT HARDIEZONEO PRODUCT INSTRUCTIONS BY VISITING HARDIEZONE.COM OR CALL 1-866-942-7343(866-9-HARDIE) p CUTTING INSTRUCTIONS STORAGE&HANDLING: OUTDOORS INDOORS 1.Posltion cutting station.so that.aldlmv.bhvrs.dust away.from the. DO NOT grind or scut with apower saw Indoors.Whisingshears-(manuai pneumatic or atrt anti reep dry d nu sv e p aer u n ur to relit others near lne c army area. electricj or gre scare and snap inethud,not recommended lot products thlciter'tiran7/i8 tire r in. installation.Installing siding wet or saturated may 2.Cut using one of the following methods: result in shrinkage at butt joints.Cony planks on a.Best: Circular saw equipped with a HardieBlade saw blade and attached vacuum dust collection system.Shears DO NOT dry sweep dust;use wet dust suppression or vacuum to collect dust, edge. Protect edges and comers from breakage. -ipnarrual,pneumatic or electric)may also be used;not _"For maximum dust reduction,James Hardie recommends using the'Best"cutting -recommended forpmrlucls lhickerUtan 7/16 in. practices.Always follow a ui ment manufacturer.`s instructions for proper eration. James Hardieis not responsibleYor damage caused P v q P P P b_Better: Circular saw equipped with a dust collection feature For best performance when cutting with a circular saw,James Hardie recommends by improper storage and (e.g.Roane saw)and a HardieBlade saw,blade. handling of the c.Good: Circular saw equipped with a HardleBlade saw blade. using aninHardl atdie2 saw blades. product. - Go to jetnesimtdieprus.cum for additional cutting and dust croutiul recommendations. TM ;MPORTAm'.The Occupatianal Safety and Health Administration(OSHA)regulates workplace exposure to silica dust'For construction sites,OSHA has deemed thatcutting filler cement with a circular saw having a blade diameter less than&Inches and connected to a commercially available dust collection system per manufacturer's instructions results in exposures below the OSHA Permissible Exposure Umit(PEL)for respirable crystalline silica,without the need for additional respiratory protection. If you.are.unsure about How-to comply with OSHA silica dust regulations,consutt.a gUafdled'industrial Hygienist or safety professional;orcontacr.your.James Hardie technical sales representative for assistance.James-Hardie makes no representation or warranty that adopting particular cutting practice wig assure your compliance with OSHA rules or other applicable laws and safety requirements. Hardiei-rim'-':ooards.are.decorative.non=toad.Dearing.grim produ.ciS. Do not use HardieTrim boards to replace any structural component. TABLE OI'".CONTENTS GENERAL REQUIREMENTS.........................................Page 1 Figure 1 ��� FLASHING/CLEARANCE REQUIREMENTS......................Page 2 FASTENING--- --------------------------------------------------------..:Page 3 HardieTrim (j Face Nailing Requirements...............................Page 3 Boards INSTALLATION...........................................................Page 4-8 f `fir HardieTrim fr{ r, fjl Boards.. Trimming Comers.----------•--------------------•----------.Page 4- Openings-------------------------------------------------------Page 4 Band Boards-------------------------------------------------Page 4 water- resistive Frieze------------------------------------------------------------Page 4 barrier Beaten Boards----------------------------•---•---.............rage 5 Fascia-----------------•........................................Page 6 / HardieTrim"'Tabs____________________________________________Page 7-8 HardieTrimCrown Moulding FIR15HING...................-----------------------------------------------Page', LapSldiingk GENERALREQUIREMENTS • Wood or steel must be provided for attaching HardieTrim boards. • Follow all appicable codes when installing HardieTrim boards. • DO NOT instali.Hardieirim boards,:such that they remain'in-contact`with standing-water'. -JamesKardW t Visit atneshardie ros com j p far the most recent version. TR1502 P1I9 09/19 41t HardieTrim®Boards µ HardieTrim may be installed with a minimum Maintain a minimum 1 in.horizontal clearance At the juncture of the roof and vertical surfaces,flashing 1/4 in,.ciearance when installed:vertically_to bretweeri.James.Hardie trim.produrts andr_lecks, and counter flashing shall be installed perthe roofing grade;decks;paths,steps,and driveways paths,-steps and driveways. manufacturer's instructions.Provide a 1 in.clearance between the roofing and the bottom edge of the trim. Figure 2 Figure 3 Figure 4 trim' water 1 in. 1 sidin resistive I �min. II I barrier o o _ horizontal I.ii flasMng. 0 o trim 0 00 6In.min. 0 �O )� dak.materal� 1-in.mrn. flashing vertical trill i-.t :�fianhing 114.in.min. edger Maintain--a.1/.4 in..clearancebetween.the bottom of James Hardie products and horizontal flashing.Do not caulk gap. Drip Edge Mortar/Masonry Figure 5 Figure 6 for fascia installation see page 6 Figure 7 siding. i L-Flashing " Do not 1/4 in.gap t. Caulk �, Z Flashing a° flashing UIV�s11 1 1.111�i 11[11f�11 � .ra!� e,�'l I1Q III:� (recommended in HZi0) Valley/Shingle Extension Figure 8 Figure 9 x Figure 10 l uik -- ,. - 4"in. min: 10 ft. max r•t rn©nrrr+e Dr-ne VRDIT_ 1/4 in. . Maintain a 1/4 in.clearance for HardieTrim boards installed undercover. clearance Under cover is defined as: Not more than 1 u feat below-a roof overhang,and • Not less than 4 inches horizontally from the edge ofthe roof overhang 75 2 P2/9 09/719 Visit fameshardiepros corn far the most recent version. HardieTrim°Boards _fir. ,._..__, .�.. .:. .... . . .,__.. . .�_.. _ ...._ __.- .. .. .. ..._.... ...,. _,._ _ .. ._ _. _.,. GENERAL FAS.iEMING REQli1REMENTS Pi EURAiAmiu FASTENNG Fasteners must be corrosion resistant,galvanized,or stainless steel. James Hardie products can be hand nailed or fastened with a pneumatic tool. .Electro-galvanized.are.acceptable but may-exhibit premature.corrosion. Pneumatic fastening is highly recommended._Set air pressure so that,the James Hardie;recommendsthe:use:of:quality,:hot-dipped:galvanized:nails. fastener:is:driven-snug:with:the:surfaceof:the.siding.Afiush:mount James Hardle is not responsible for the corrosion resistance of fasteners. attachment on the pneumatic tool is recommended.-This will help control the Stainless steel fasteners are recommended when installing James Hardie depth the nail is driven.If setting the nail depth proves difficult,choose a products near the ocean,large bodies of water,or in very humid climates. setting that under drives the nail. (Drive under driven nails snug with a smooth faced hammer DoeSJlot apply for rinstallation to steel framingl. Manufacturers ofACO and.CA preservative-treated wood recommend spacer materials or other physical barriers to prevent direct contact of ACO or CA preservative-treated wood and aluminum products.Fasteners used. Flush Snug Flush to attach.Hardiebm'Tabs to preservative-treated wood shall be of hotflak dipped zinc-coated galvanized steel or stainless.steel and in accordance to 2009 IRC R317.3 or 2009 IBC 2304.9.5." do not do not DO NOT Figure A Figure B over drive under STAPLE Finish Nail Siding Nail siding nails drive nails FACE-NAILING:REQUIREMENTS Use 2 in.minimum 16 ga.finish nails to attach HardieTrim boards to wood frame construction.ET&F or equivalent fasteners or screws may be used to attach-HardieTrim boards to steel frame construction. Fasfoning ins*sucaons are similar for all applications.'WnGrl using finish nails,position'nails-o Closer than-1'%2 in.from'the edges of tho trim and for all Other fasteners no closer than 3/4 in.Fasteners must be no closer than 1 in.from ends of trim and spaced a maximum of 16 in.O.C. Ensure trim is adequately fastened. James Hardie recommends using slainiess steer:finish nails when-instaiiirig.HardieTrim products: Minimum fastener guide for finish nailing: plywood or water-resistive Pre-built comer Site Built comers Other areas(e.g.window OSB sheathing. barrier him;and Wildboardsl 1-naii.every 1.6 in.to.attach.boards 1 in.from 4 m. together+1 nail every 16 in.each board 6 in. 1 nail every 16 in.to attach boards 2 nails every 16 in. 2 nails every 16 in. ends to e'ser-1 2 nails every 16 in.each board I S in. -3.nails.every16 in. _3 nails.every 1.6.in. 12 in. 4 nails every 16 in. 3 nails eve 16 in. 11 I 1 Use a 2 in.finish nail to fasten-trim together.-Longer finish nails may'bend. 4 h \ ( i6 m Q Cr'inax_in ( , • - � � fl hn ' ✓��:. :. : °� of ° ° _ _ o ° o°/ Vertical trim may be installed with a 1/4 in.min.clearance'. Figure 11 \ / Leave a minimum 118 in.gap betwean the siding and trim,then caulk. 'Follow ail applicable codes when installing HardieTrim boards F Visit jameshariliepros com for,the most recent version. TR1502 P3/9 e9ltSr ,=77HardieTrim'Boards sssse+-rns r nrsr�as TRIMMING CORNERS TRIM APPLICATION FOR WINDOWS,DOORS-&-OTTER OPENINGS When installing comers or other vertical trim, Flashing over trim is required per code for all installation methods.(figure 14) position boards on the wall and attach(figure 12). i'•re-$tiiii ba'nor 8 Figu;e.1T water- Aiternatively,corners can be pre-built off the wall ° resistive using 2 in.finishing nails.Each side of the pre-built harrier comer must be secured to.the wall#igure..13)., do not Ff Ufe12 cau top edge lkalong HardieTrim siding ButttoSfdfng- g board Trim the opening prior Gashing d' to the Installation of the corner over trim . w �. siding.Position trim studs boards on the wall and:. ` r securs PJI^ proper fastener spacing at - edges and ends. I� 16 in.max. 471, .07e�,I I _ d Butt to Siding 2 in.Finish nail Figure 13 Horizontal �1 Flashing. c s er _ 1 stud om NOTE:Follow your window/door manufacturer's installation j Instpirtioncfprraulking guidanre.hetween window.and.Itim.,, Dave.a.mitiimum.l/K lh..gap between' siding and trim,then caulk. ` f 2 in.Finish nad BANDBOARD FRIEZE-BOARDS Figure rs For band board water resistive barrier HardieTrim boards can applications,a flashing Is be used.as-frieze.board. required over the trim.. (figure 15) {figure 15) Figure 15 d—lap.siding f sheathing I' 1/4 in,gap blocking/support HardieTrim ff required I frieze board. i� HardieTrim \ II �` frieze board i Bashing �—HardieTrim board Shim y behind a trim caulk if required Butt to Siding Tnm Over Siding HardieP( _ lap siding k TR1502 P4/9 09l19 Visit lameshardwpra "for th s came most recent trerstan HardieTrim®Boards uric i LN 11JU NIM) HORIZONTAL PANEL-JOINTS =Figure�7 _ HardieTrim k R ,• Batten At horizontal panel joints HardieTrim battens must be upper panel installed according to option 1 or 2 below.When 1/4 in.gap installing.HarbieTrim Battens.horizontally,they.must.be Do not inctaliad ag a nanel jnint arrnrdjns to ontinn'2. 0.. Option 1 Figure 17-No horizontal band board-Make a 22.5-45 Z-flashing degree weather cut,in the HardieTrim.batten just above the.1/4 In.clearance between panels. lower 9 r panel Option 2 If �� 1 � d , t4 Figure 18-Horizontal Band Board-Install a horizontal 6 a - r v a f+6 f .f f ti, + . rti e r�e crU IYU ljM ax u Uuu ti x - sary batten to the band-board-and start the top batten at-the k bottom edge of the top panel,Maintain a 1/4 in. clearance above horizontal flashing. f r t G x Figure 18 6atteii 0 1 1/4 in.gap i �Z flashirtg 1 inwrc 14 fu 4 ,." Batten. f , p,? lower Panel ¢ , z i 4 1 V a _a 4 7 5 visit jarr esi<ardiepres.comfomhe mo' 6eantversion Tr�rou[rnr8 ger19 � � II I ■ ,_ .:,,,.... .. ,< Y . ...n.u.. ...n... .. .....:_ .... . ,x,�r .i, .K . :« ., < r.. ,..i .. ., ,. .... n ,e ,.... _e,. . . -...,.,r o J HardieTrim®Boards ' .�,..t...,.... .a..._.. ....,. .:..4,...___.....- _-. -.. ............ -._+..:...r1.J..,...... ,tom_., ...-.K..<-.... .,......� .r._...._...<,......._. t._..,,._ .,.-„n...,_ ....,.....__..... ._,..w =n ers n Do not use HardieTnm to replace any structural componerrt HardieTrirn boards can be fastened directly over a2x sub-fascia or directly to rather tails.Check local building-code for relevant codes. Option 1 Over sub-fascia:(figure 1'9) When installing.HardieTrim.boards over solid 2x sub4ascia.use.minimum 2.in.,1.6 gauge corrnsion.resistant.finish.nails..(see fastener guide-beloia) roofing Figure 19 -` roofunderiaymeritv roof sheathings � �� Gutters: drip edge clashing dames Hardie recommends the use of rain gutters whenever possible. Do not attach gutters directly.to HardieTrim y � -Use gutter hangers that attach through the-root-sheathing into a-rafter tail or other structural member. roof framing r Soffit ti a HardleTrim board When installing HardieSoffit.additional framing/blocking may be needed depending on application.Refer to HardieSoffit installation :ng sub fascia instructions.for.guidance. HardieSoffit Panel Option 2 Direct to rafter tails:(figure 20) When installing HardieTrim boards%nithout the presence of'a Zy sub-fascia,a minimum 8d siding corrosion resistant rialls must be used to attach Hardie_rim hoards 'DO-NOT use finish nails.(refer to fastenerguide-belc;M. fasI iafasterner Guide :rggure zo FASTENER SPACING tiar6`eTdm direct•#oflafter Over )rSub4asoin A Baud (min 8d siding) (Minimum.2 in,16 ga:Finish nails} H00r10g 2 nails spaced maximum ;n 2 nails every rafter spaced max a Is p 6. 16 in.O.C. Simattiing =�r, 24 in. O.C. Hoof. 3 nails every rafter spaced max 3 nails spaced maximum Underlayment 8 in. �F 24 in. O.C. 16 in.O.C. fi`",x> r Style opt, 1 n ip 4 nails spaced maximums drip edge T6In.-O.C. , Flashing 7, a" M:RP F - HardieSoffit HardieTrim Panel Board 1 J TE<'�5P -P6j9 U909 <Issd:iamesfiard�epras casg',4as the snort reserst usrsinn _° _<„ _ t 4 HardieTrim®Boards FASTENER REQUIREMENTS for.Corners,Band.Boards,-Windows,_and.Door.Appli(;ations: HardieTrim boards may be installed with HardieTrimT^^Flat Tabs and HardieTHMTM Comer Tabs which provide concealed fastening,Only HardieTrim Flat and Corner Tabs can be used with HardieTrim boards to create a concealed fastening. ! ep A. h"ard:- ai PI_t T-L_to♦L_L._I.!le L_ n �� 1 IA 1 I i-. A f si l le l l at eit l: AtiBin na,utetitnt rtat Taus to lit e aaLK s,uc Of ite nt!t!>5(fty fOtir; ro ga. .. iH: z 1�w ln:It fia1T04i t rOtil 0,,t ,0i,resistant staples,equally spaced to one row,positionedno closer than 1/2-in.from trim edges using a pneumatic staple gun.(figures 21,22) Step 2: For wood frame construction,attach the trim to the building.with minimum 2,6d siding nails fastened through the HardieTrim FlatTabs(figure 23).EW or equivalent fasteners may be used toattach the HardieTrim Flat Tabs to steel frame construction. Fastener spacing will vary based on application. Refer to fastener table on page 9. Refer to specific sections in these instructions for required fastener spacing by application (window,band board,etc.) -Fort Fascia;Rake,and Frieze board Applications: HardieTrim tabs cannot he used in fascia,rake,or frieze board applications.Follow Face nailing fastening specifications. Installation of HardieTrim tabs in Coastal Regions: -James Hardie-requires Ahat.-stainless steel:staples.&.fasteners be used.when installing HardieTrim.Tabs in coastal-regions. Installation of HardieTrim Tabs over Pressure Treated Lumber:HardieTrim tabs shall not come in direct contact with ACQ or CA preservative-treated wood.Refer to the General Fastening section of this document for further information. HardieTrim hoardg with T.6.1ohm-TPdrnning :Pornowo the Iarn pate sheet as soon as passlble after attaching.the Vim to the building. Min 1/2 in.. , Figur'e.23. Ih1,n 2 to Fasten 4 staples minimum in from Vim edge H Figure 21 AR 7t.HardieTrim Back view.. �—t, b -mirmum 7iis in. —16 in:O:C.max—� OSB w th min 2 6d HardieTrim Flat Tabs siding nails -- Figure 22 Front view Figure 24 Trim Application for Windows. Doors&Other Openings �3 Trim the opening prior to the installation of the siding.Place a Flat Tab at the end of each trim Flush HardieTrim board and one tab everv16 in:OC.Attach the _ H4•d,eTdm Flat and Carver Tabs(?G�a _ trim boards and Flat -around the opening as �� shown in figure 24.Use 16 ga.galvanized 2 in. I Cornerrabs long finish nails to ensure.prgperfastening if Siding nail Do not Only use.staples to needed. ® attacheslab under fasten HardieTrim.Flat and to the wall, drive nails. Comer Tabs to the trim boards. 4 �is'It]iaileSiiardieNruS Corn iePlhe_rnds reGerlt Beraieil 1Ti15e2°7 9 tla°3 tea_, HardieTrim®Boards TniiviiviiN.G CORNERS When using HardieTrim tabs prebuild outside comers off the wall. • Attach.HardieTrim Comer.Tabs to the backside of the trim using eight(8)-1.8,qa.1/2 in.L x 1/4 in..W narrow crown corrosion resistant staples using a pneumatic'stapler;Ensure the HardieTrim Corner Tabs are fastened tight and-straight to the trim boards.(figure 25) For woad frame construction,attach trim to building using min.6d siding nails fastened through the HardieTrim Corner Tabs attached to minimum 7/16 in.OSB*.(figure 26) • Attacha HardieTrim Corner Tab 1-in:from each ends and every•214in.O.C. • TIP:Creating a jig for the workstation-is recommended-to ensure corners are fastened securely and straight.(figure 27) Figure 25. Figut'e;26 Figure.27, Fasten 2 in.x 4 in. Comer studs Corner Tabs timber blocks ✓' 1 :';_.,,; to a work bench `. , r �#���cap,_ Use 4 staples per piece. v bA �-i $, L-shaped tab to the - 1 pre-built comer.Use the nail line on the ` tabs as a guide. 'Siding nail fnrnerTah HardieTrim- Fasten 2In.x in,stud to the:timber. acks BAND BOARD Terminate ends of the Band Board into Trim or Siding or miter cut the edges of the trim at the corners of the building.Place a HardieTrim Flat Tab at the end of each trim board and one tab every stud at a maximum of,16 in.O.C..The HardieTrim.Flat;Tabs should be attached to the trim in an alternating:pattern to the top andbottam of.the:band board (figures 21,22). Use 16 ga,galvanized 2 in.long finish nails to ensure proper fastening.Wneeded. Trim Tab Fastener.Tabfe Application Framing Material Fastener Fastener Max Tab Spacing .t Tab is nailed into (tab to framing) (tab to trim) (inches on center) It Wood Stud one 6d corrosion resistant siding nail (minimum G=0.42) installed through center of tab into framing Four 18.ga.X 1/2-in. inI4' iwfCuu resist ifiMinimumAPArated Flat Tab 7/16 in.OSB siding nails equallgspaced installed corosion.resistant. through tab into framing crown staples,equally spaced in one row Minimum-20 One Na.8 X.1 In-long X.O.323 In-head. steel diameter screw(corrosion resistant) gauge 9 installed through flange into framing W.00d,Stud:: Oo.each.flange,Install one 8d corrosion resistant siding nail through (17ei1i1i1ii1Trv=0,4�r 'tab into frarning ' For each piece of trim, install Four 18 ga.X Minimum APA rated. On each flange,Install two 4d ring 1/2 in.long X 1/4 in. Min Comer Tab _ imu in:A shank corrosion resistant siding'nails wide corrosion 20 through-tab-intoframing -resistant crown staples, equally space in two On each flange,install one No.8 X 1 in. rows Minimum 20 long X 0.323 in,head diameter screw gauge steel (corrosion resistant)lhroughtab into irW^ing. Z'isltjan:esliar`dte�rus:ce rtor the rnest cent _ TR15p7 a9-[3gf,1A _ HardieTrim®Boards r 4 ` FINISHING CUT EDGE TREATMENT _Cauik,..paint.or:prime_all..field.cut:edges_James:Hardie.touch-up.kits.:are-required:to_touch=up GolorPlus.products. CAULKING Forbest results use art tlastomeric Joint Sealari complying with-AS I IN-0O20 Grade NS,Class 25 orhigher"or a Latex Joint Sealarttcompiying with AS]M, C834.Caulking/Sealant must be applied in accordance with the caulking/sealant manufacturer's written instructions.Note:some caulking manufacturers do not allow"tooling". PAINTING DO NOT use stain,oiValkyd base paint,or powder coating on James HardieO Products.Factory-primed James Hardie products must be painted within 180 days of installation. 100%acrylic topcoats are recommended.Do not paint when wet.For application rates refer to paint manufacturers specifications.Back-rolling is recommended if the siding is .SI1faVP.[i; CO'LORPLUS TECHNOLOGY CAe tLK!NG TOUCH.-UP SLAIMNATE •.Care.should be.taken.when handling and.cutting.James HardieO..ColorPlus®..products.During.installation.use.a wet soft cloth.or soft.brush.to gently.wipe off any residue or construction dust left on the product,then rinse with a garden hose. •Touch up nicks,scrapes and nail heads using the ColorPlus©Technology touch-up applicator.Touch-up should be used sparingly. If large areas require touch-up,replace the damaged area with new HardiePlank®lap-siding with ColorPlus®Technology. +.LaminateSiluet filusl be'retnoVed tnlfinydately after Inst'alldikin of.each CUurat,~. •Terminate non-factory cut edges into trim where possible,and caulk.Color matched caulks are available from your ColorPluO product dealer. •Treat all other non-factory cut edges using the ColorPlus Technology edge coaters,available from your ColorPlus product dealer. Note:James Hardie does not warrant the usage of third party touch=up or paints used as touch-up of r James Hardie,ColorPlus products: Problems with appearance or performance arising from use of third party touch-llp paints or paints used as touch-up that are not James Hardie touch-up will not be covered under the James Hardie ColorPlus Limited Finish Warranty. PAINT ING JAMES*HARDIG°MING AND TRIM PRODUCTS WITH COLORPLUS°TECHNOLOGY When repainting ColorPlus products,James Hardie recommends the following regarding surface preparation and topcoat application: •-Ensure the surface is clean,.dry,.and free.of any.dust,:dirt,or mildew Repdming is:normally:not necessary •100%acrylic topcoats are recommended • DO NOT use stain,oiValkyd base paint,or powder coating on James Hardie®Products. • Apply finish coat in accordance with paint manufacturers written instructions regarding coverage,application methods,and application temperature -• DONOT�caulkrrailheads-whemusina GolorPluS-products,-refertothe ColorPlustouch-uo"section Tn15O P919 09n9 DANGER:May"cause cancer if dustfrom product is mhal d.Causes damage to Gmgs and respiratory system through prolonged�ur repeated inhidalion of dust from proauct Refer lathe current product Sa(etyData Sheet before use. °� s nz W d z ac.bd ^9 f r c ehrzrsos r,em , a;4n 1 p w ,rti r 3 re d b, ch zs s^,.y, ^ini.^.5r'dnllin uP.g g h,g .eth li d^y:b c mwM;a h h stsan:ng.i lip,disposigq bf dir moving O;e pusi Nlnen:doirig an}of fhbse acinnies L,a m nsr it at geperat°s dusi you must(1)comply Guth the OSHA st Rdard fore aca dust;aridlo ka'�:;other applicable (2{ipilow James Hardie slitting irisituctians to reducer limit the mlease.of dust,(3)wam,ofhers In the area to avoid bjesthn g the dust;(4)viiheri Using mecUa I l saw'ofhigh'speed cutting taots,'vtork outdoors ind use dust collection equiament;and'(5),9 ni atha d6stcontraisare available;Meat a dust masker respirator that me?tc NIOSH requirements je.g.N 95 d++?st mash.During clean-up,use a weg maintained vacuum soil hger apprgpnaie for capturing fine{respirable)duster.uso'. wet'clean=up methods s never dry:swsep " A WmNING:This product can expose you to chemicals inciuding respirable crystalline silica,which is known to the State of California to cause cancer.For more information go to PtiWarnirrgs c�a.00v. RECOGNITION:HardieTrim boards may be installed as an equal alternative to conventional trim permitted for use in;2006,2009,2012&2015 International Building Code,Section 1403,and the 2006,2009,2012&2015 International Resideribal Code for Die and Tv.c Family Dwellings,Section R703. 0 2018 James Hardie Building Products,Inc.All rights reserved TM,SM and a Product warranties,safety information and additional installation '1 'amesFlardie denote trademarks or registered trademarks of.lames Hardie Technningy limited. information are available at jameshardlepros.com