Loading...
HomeMy WebLinkAboutPlans1 5 9 ' - 7 "82'-4"82'-4"159'-7"PVMCBUMMDPACDSD 4 3 ' - 5 " 59'-1"6'-9"32'-7"SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEA-00CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC123PLOT PLAN WITH ROOF PLANHOUSE PHOTOVICINITY MAPSCALE: 1/32" = 1'-0"A-00SCALE: NTSA-00A-00SCALE: NTSPLOT PLAN & VICINITY MAPPROJECT SITEPROJECT DESCRIPTION:19x355 LG NEON2: LG355N1C-N5 (355W) MODULESROOF MOUNTED SOLAR PHOTOVOLTAIC MODULESEQUIPMENT SUMMARY19 LG NEON2: LG355N1C-N5 (355W) MODULES19 ENPHASE: IQ7PLUS-72-2-US MICROINVERTERSSYSTEM SIZE:6.75 kW DC STCARRAY AREA #1:865.06 SQ FT.SHEET INDEXA-00 PLOT PLAN & VICINITY MAPA-01SYMBOLS & SYSTEM DESCRIPTIONS-01ROOF PLAN & MODULESS-01.1PARTIAL PRESSURE AND MODULES EXPOSURES-02STRUCTURAL ATTACHMENT DETAILSS-02.1STRUCTURAL CALCULATIONSS-02.2SPAN TABLESE-01ELECTRICAL LINE DIAGRAME-02WIRING CALCULATIONSE-03SYSTEM LABELINGDS-01-06DATA SHEETSSUN VALLEY DRIVE,GOVERNING CODES:FLORIDA RESIDENTIAL CODE, 7th EDITION 2020 (FRC)FLORIDA PLUMBING CODE, 7th EDITION 2020 (FPC)FLORIDA BUILDING CODE, 7th EDITION 2020 (FBC)FLORIDA MECHANICAL CODE, 7th EDITION 2020 (FMC)NEC 2017 CODE BOOKASCE 7-16PROJECT SITE1.5-STORYHOUSE(N) (19) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSROOF #1(19) LG NEON2: LG355N1C-N5(355W) MODULESEXISTINGDRIV EW A Y(N) SOLADECK1" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(N) AC DISCONNECT (INTERIOR)(N) MAIN DISTRIBUTION PANEL(E) UTILITY METER(N) PRODUCTION METER (IF REQUIRED)(N) PV COMBINER BOX System Description This system is a grid-tied, PV system, with PV generation consisting of 19 LGNEON2 LG355N1C-N5 (355W) MODULES with a combined STC rated dc output powerof 6745W. The modules are connected into 19 ENPHASE IQ7PLUS-72-2-USMICROINVERTERS. The inverter has electronic maximum power point tracking tomaximize energy captured by the PV modules. The inverter also has an internal groundfault detection and interruption device that is set to disconnect the array in the eventthat a ground fault that exceeds one ampere should occur. The inverter has DC and ACdisconnect integrated system and labels are provided as required by the NationalElectric CodeWhen the sun is shining, power from the PV array is fed into the inverter, whereit is converted from DC to AC. The inverter output is then used to contribute to thepower requirements of the occupancy. If PV power meets the requirements of theloads of the occupancy, any remaining PV power is sold back to the utility. When utilitypower is available, but PV power is not available, building loads are supplied by theutility.The inverter meets the requirements of IEEE 1547 and UL 1741. This means thatif it detects a loss of utility power, it will automatically disconnect from the utility.When utility voltage is restored, the inverter automatically reconnects to the utility gridafter verifying utility voltage and frequency stability.On a day with average Florida sunshine, this system outputs 25.92 kWh per dayon site.MicroinvertersPV ModulesPoint ofUtilityConnectionUtility MeterJunctionBoxSection..............Elevation ...........Detail ................Detail ................(Enlarged Plan)Keyed Notes ..........Ground Terminal .....Grounding Point/rod....Solar Panel ......... orCombiner Box ..........DC Disconnect ..........Main DistributionPanel ......................Fuse ......................Overcurrent Breaker ..Inverter ....................Transformer .............Automatic ...............Transfer SwitchXX-XXXX-XXXX-XXXX-XX1CBDCDMDP Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is located Detail ID Letter Sheet where section is locatedArea to be enlargedKeyed note designationon applicable sheetATS00Module with SourceCircuit numberAC Alternating CurrentAPPROXApproximateAWGAmerican Wire GaugeCBCombiner BoxDCDirect CurrentDCDDirect Current DisconnectDISCDisconnect(E)ExistingEL ElevationEQEqualJBJunction BoxMCB Main Combiner BoxMFRManufacturerMINMinimumMISCMiscellaneous(N)NewOCPDOverCurrent Protection DevicePOCCPoint Of Common CouplingPVPhotovoltaicSFSquarefoot/feetSTCStandard Test ConditionsTBD To Be DeterminedTYPTypicalVIFVerify In FieldWPWeather ProofSYMBOLS & DESCRIPTIONSHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEA-01CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSymbols:Abbreviations:SYSTEM 5 7 ' - 1 "43'-0"P VM CB UM MD P A C D SD4'-0" TYP.SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMES-01CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1ROOF PLAN & MODULESS-01SCALE: 3/32" = 1'-0"MDPACD- AC DISCONNECT- MAIN DISTRIBUTION PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- TRUSSES- CONDUITROOF PLAN &MODULES- COMBINER BOXCBMODULE TYPE, DIMENSIONS & WEIGHTNUMBER OF MODULES = 19 MODULESMODULE TYPE = LG NEON2: LG355N1C-N5 (355W) MODULESMODULE WEIGHT = 40.98 LBS / 18.59 KG.MODULE DIMENSIONS = 40.0"x 66.9" = 18.58 SFUNIT WEIGHT OF ARRAY = 2.21 PSFLG NEON2:LG355N1C-N5(355W) MODULES40.0"66.9"LEGEND- UTILITY METERUM- SOLADECKSDPM- PRODUCTION METERARRAY AREA & ROOF AREA CALC'SROOFROOF TYPEARRAYAREA(sq.Ft.)ROOFAREA(Sq. Ft.)ROOFAREACOVEREDBY ARRAY(%)TILTAZIMUTHTRUSSSIZETRUSSSPACING#1S- TILE ROOF353.21865.0640.8322.6°92°2''x4''24" o.c.2) EXISTING RESIDENTIAL BUILDING IS A S-TILE ROOF WITH MEANROOF HEIGHT IS 20 FT AND SYP 2"X4" ROOF TRUSSES SPACED 24"O.C. EXISTING ROOF SLOPE FOR SOLAR SYSTEM RETROFIT IS 26.6DEGREES. CONTRACTOR TO FIELD VERIFY AND SHALLREPORT TO THE ENGINEER IF ANY DISCREPANCIES EXISTBETWEEN PLANS AND IN FIELD CONDITIONS* I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3. BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS AND EQUIPMENT DEAD LOADS. *WINDZONESNON - EXPOSED MODULESEDGE / EXPOSED MODULESSPANCANTILEVERSPANCANTILEVERZONE 12' - 9"0' -11"1' - 10"0' - 8"ZONE 1'XXXXZONE 2e1' - 11"0' - 8"1' - 3"0' - 5"ZONE 2nXXXXZONE 2r1' - 11"0' - 8"1' - 3"0' - 5"ZONE 3e1' - 11"0' - 8"1' - 3"0' - 5"ZONE 3rXXXXGENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO SYP TRUSSES SHALL BE INSTALLED ASSHOWN IN SHEET S-02 AND AS FOLLOWS FOR EACH WIND ZONE:WIND ZONE2r (TYP.)WIND ZONE 1 (TYP.)WIND ZONE2e (TYP.)WIND ZONE3e (TYP.)(N) PV COMBINER BOX(N) AC DISCONNECT(N) MAIN DISTRIBUTION PANEL(E) UTILITY METER(N) PRODUCTION METER (IF REQUIRED)ROOF #1(19) LG NEON2: LG355N1C-N5(355W) MODULES(81) PV ROOF ATTACHMENT@ 22", 15" & 33" O.C. MAX(N) (19) ENPHASE: IQ7PLUS-72-2-USMICROINVERTERSUNIRAC STANDARD RAIL(N) SOLADECK1" IMC, RMC, FMC, LFMC, PVC,HDPE, NUCC, RTRC, LFNC, FMT,ENT OR EMT CONDUIT RUN(E) BACK YARD(E) FRONT YARDR O O F # 1 T I L T - 2 6 . 6 ° A Z I M . - 9 2 ° SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMES-01.1CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLC1PARTIAL PRESSURE AND MODULES EXPOSURES-01.1LEGEND- MIN. MODULE EDGE DISTANCE LINE- EXPOSED MODULEPARTIAL PRESSURE ANDMODULES EXPOSURESCALE: 3/32" = 1'-0"- MODULE EXPOSURE LINE- NON- EXPOSED MODULENOTE : PARTIAL PRESSURES OF THE WIND ZONES ONALL MODULES HAVE BEEN VERIFIED AND ARE WITHINTHE ALLOWABLE PER THE MANUFACTURERSPECIFICATION, INSTALLER SHOULD FOLLOW THELAYOUT TO AVOID HIGHER ZONAL PARTIALPRESSURES. ANY CHANGES IN LAYOUT SHOULD BEREPORTED BACK TO THE ENGINEER OF RECORD.2h2DISTANCE : 2' - 0"0.5hDISTANCE : 10' - 0"(E) FRONT YARDROOF #1(19) LG NEON2: LG355N1C-N5(355W) MODULESWIND ZONE2r (TYP.)WIND ZONE 1 (TYP.)WIND ZONE2e (TYP.)WIND ZONE3e (TYP.)(E) BACK YARD0.5h2h₂- EDGE MODULEP1P2P3P4P6P5P7P8P9P10FOR EXPOSED MODULESFOR EDGE MODULESFOR NON-EXPOSED MODULESALLOWABLE MODULE UPLIFT PRESSURE 2 RAIL: 88PSF 1'-0"SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMES-02CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSTRUCTURALATTACHMENTDETAILS2ATTACHMENT DETAIL (ENLARGED VIEW)S-02SOLAR MODULE(E) ROOF SHEATHING(E) S- TILE ROOFATTACHMENT DETAILS-02SCALE - 1'' = 1'-0''12" X 4" TRUSSES @ 24" O.C.SCALE: 1" = 3"h₂SEE (2/S-02) FORENLARGED VIEWSUNMODO TRIPOD KIT INCLUDES:1X TRIPOD STANCHION3X #14 WOOD SCREWS1X 3/8 HEX FLANGE SCREW1X AL FLASHING WITH EPDMSEALANT COVERGROUNDING END/MID CLAMP(E) ROOF SHEATHINGL-FOOT(E) 2" X 4" TRUSSES @ 24" O.C.UNIRAC STANDARD RAIL (TYP.) SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMES-02.1CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSTRUCTURALCALCULATIONS SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEE-01CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCELECTRICALLINE DIAGRAME-01SCALE: NTS1ELECTRICAL LINE DIAGRAMSOLAR ARRAY (6.745 kW-DC STC)(19) LG NEON2: LG355N1C-N5 (355W) MODULES(01) BRANCH OF 10 MODULES(01) BRANCH OF 09 MODULESINTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED150.0 A + 30A = 180ABUSS RATING x 120%150A x 120% = 180A(N) SOLADECK600 V, NEMA 3RUL LISTEDQ CABLEL2L1NL2L1GN20A/2PG10AGG (N) 125A ENPHASE IQ COMBINER 3(X-IQ-AM1-240-3) [WITH UPTO (4)2-POLE BREAKERS AND ENVOYCOMMUNICATION GATEWAY]GGGGL2L120A/2PGGGGGGGGGGGENPHASE: IQ7PLUS-72-2-USMICROINVERTERSPV MODULESGGL2L1L2L1L2L1L2L1(2) #12 AWG THWN-2 – RED(2) #12 AWG THWN-2 – BLACKEGC#6 AWG THWN-2 GNDIN 1” IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT, OR EMTCONDUIT RUN"(3) #6 AWG THWN-2(1) #6 AWG THWN-2 GNDIN 1" IMC, RMC, FMC, PVC,LFMC, HDPE, NUCC, RTRC,LFNC, EMT, FMT, ENTCONDUIT RUN(N) JUNCTION BOX600 V, NEMA 3RUL LISTEDGGGNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, AND THOSE SET FORTH BY THEFLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULEMANUFACTURER AND MODEL NUMBER, INVERTER MANUFACTURERAND MODEL NUMBER, AS APPLICABLE.L2L1L2L1NNGG(N) AC DISCONNECT:240V, 60AMP RATEDNEMA 3R, UL LISTEDLOCKABLE AND NON-FUSIBLE(IF REQUIRED)(E) MAIN DISTRIBUTIONPANEL, 150A RATED, 240V.EXISTING GROUNDINGELECTRODE SYSTEMBI-DIRECTIONALUTILITY METER1-PHASE, 240VL2L1L2L1GL2L1L2L1L2L1L2L1L1L2NL1L2NL1L2N(E) MAIN BREAKER150A/2P, 240VN30A/2PTO UTILITY GRIDUNDERGROUND SERVICEENTRANCE (3) 2/0 THHN-2(2) 12/2 ROMEX RUN IN ATTICOR(2) #12 AWG THWN-2 – RED(2) #12 AWG THWN-2 – BLACKECG #6 AWG THWN-2 GNDIN 1” IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEE-02CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCWIRINGCALCULATIONSAC CONDUCTOR AMPACITY CALCULATIONS:FROM ROOF TOP SOLADECK TO LOAD CENTERAC CONDUCTOR AMPACITY CALCULATIONS:FROM AC COMBINER BOX TO MSPELECTRICAL NOTESENPHASE IQ7PLUS-72-2-US MICROINVERTERInput Data (DC)Recommended Input Power (STC)Maximum Input DC VoltagePeak Power Tracking VoltageOperating RangeMin. / Max. Start VoltageMax DC Short Circuit CurrentOutput Data (AC)Maximum Output PowerNominal Output CurrentNominal Voltage / RangeNominal Frequency / RangeExtended Frequency / RangePower Factor at rated powerMaximum unit per 20A Branch Circuit235-440W +60V27V-45V16V-60V22V / 60V15A290W1.21A240V/211-264V60 Hz47-68 Hz1.013 (240 VAC)1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT. THE TERMINALS ARE RATED FOR75 DEGREE C.3.THE WIRES ARE SIZED ACCORDING TO NEC 110.14.4.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11.THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13.MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).I ERMOCRATES CASTILLO PE# 52590 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM AND ELECTRICALCOMPONENTS ARE DESIGNED AND APPROVED USINGTHE STANDARDS CONTAINED IN THE MOST RECENTVERSION OF THE FLORIDA BUILDING CODE. FBC 107. SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEE-03CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCSYSTEMLABELINGRAPID SHUTDOWNSWITCH FORSOLAR PV SYSTEMLABEL LOCATION:AC DISCONNECT(PER CODE: NEC690.56(C)(3))LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)WARNINGELECTRIC SHOCK HAZARDLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.13(B))TERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONLABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))ADHESIVE FASTENED SIGNS:· THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED.· WHERE REQUIRED ELSEWHERE IN THIS CODE, ALL FIELD APPLIED LABELS, WARNINGS, AND MARKINGS SHOULD COMPLY WITH ANSI Z535.4 [NEC 110.21(B) FIELD MARKING].· ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT [IFC 605.11.1.3]PHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 23.0 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICELABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))! WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEM!NOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATING FOR AC MODULE PROTECTION PER CIRCUIT-VVAHz60290A240A1.2120LABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)DATA PER PANELTURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TOSHUT DOWN PV SYSTEMAND REDUCESHOCK HAZARDIN THE ARRAYSOLAR PV SYSTEM EQUIPPEDWITH RAPID SHUTDOWNSOLAR ELECTRICPV PANELSLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC 690.56(C)(1)(a), IFC 605.11.3.1(1)AC DISCONNECT6.75 KW SOLARDISCONNECT LOCATEDPHOTOVOLTAICSYSTEM MICROINVERTERSLOCATED UNDER EACHPV MODULE INROOF TOP ARRAYAC COMBINER BOXLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)SOLAR CONNECTIONLINE SIDE TAP SOLARBREAKERLABEL LOCATION:COMBINER BOX(PER CODE: NEC690.52)LABEL LOCATION:INVERTER(PER CODE: NEC690.52)LABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION(PER CODE: NEC690.54)LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(A))LABEL LOCATION:POINT OF INTERCONNECTION(PER CODE: NEC 705.12(B)(2)(3)(b))WARNINGIN CASE OF EMERGENCY, CONTACT:SUNPRO SOLARPH. NO. : (866) 450-1012LABEL LOCATION:MAIN DISCONNECT(PER CODE: NFPA 11.12.2.1.5) SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-01CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-02CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-03CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-04CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-05CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET SHEET NAMESHEET SIZESHEET NUMBERGOLDSTEIN RESIDENCE ANSI B11" X 17"PROJECT NAMEDS-06CASTILLO ENGINEERINGSERVICES, LLC620 N. WYMORE ROAD,SUITE 250,MAITLAND, FL 32751COA # 28345TEL: (407) 289-2575ERMOCRATES E. CASTILLO - FL PE 52590REVPROJECT INSTALLERSignature with SealDATEDESCRIPTIONREVISIONS5617 SUN VALLEY DR, FORT PIERCE FL 34951 COPYRIGHTED BYCASTILLO ENGINEERINGSERVICES, LLCDATA SHEET