HomeMy WebLinkAboutREVISION, APPROVED, Underlayments.pdfOFFICE USE ONLY:
DATE FILED:
REVISION FEE:
LOCATION/SITE
ADDRESS:
PERMIT #
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462.1553
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
2355 DYER RD PORT SAINT LUCIE, FL. 34952 (PERMIT # SLC 2104-0507)
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Underlayment submitted is no longer available - submitting the replacement FL approval
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CCC 1330918
BUSINESS NAME: ALLIANCE GROUP
QUALIFIERS NAME: DANIELLE RYCKMAN
ADDRESS: 515 NW ENTERPRISE DRIVE
CITY: PORT SAINT LUCIE STATE: FLORIDA
PHONE (DAYTIME): 772-492-8006
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME:
STATE:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE:
PHONE (DAYTIME):
SLCCC: 9123109
Revised 06130117
ST. LUCIE CO CERT. #:
FAX:
ZIP: 34986
ZIP:
ZIP:
4/2412021 Florida Budding Code Online
Business Professional Regulation
MIS HomeLop In use, Rewstrauar Hol rop,a suarnit sorcnarge skits A FMs vvWicabans Conten us gc.1s sae Map Links Sea-1r Product Approval
dbp4 t� i�a
INW Yseuoase c ur
rr2UkV Ap;Zrg4Gi H r i r n, ApaurAL2fl_'S - Apphcstaan Geta.l
FL a FL2569-R21
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archives
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Email 1640 rue Haggarty
Drummondville, NON -US 00000
1819)478-2400
memathieu asoprema. Ca
Authorized Signature Marc -Etienne Mathteu
memathieuosoprema.ca
Technical Representative Marc -Etienne Mathieu
Ada res5/Phone/Erna il 1688 lean-Bercrimans-M.chaua
Drummondville, NON-LIS 00000
(819) 478-2400 Ext3327
memathieuLtsoprema.ca
Quality Assurance Representative lean -Francois Cote, Ph.D
Address/Phone/Email 1640 rue Haggarty
Drummondville
(888)811-3145
Jfcote@soprema.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name wno developer the Robert J- M. Nleminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W- Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R21 C01 202U 01 CUl—NlEM1NL�L.p_21
Referenced Standard and Year (of Standard) $two;d
Year
ASTM 01970
2015
ASTM D4798
2011
ASTM D6163
2015
FM 4474
2011
FR5AJTR1 Sixth Edition
2018
UL1897
2015
https./lwww flondabudding org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsKQFEnckBl OBErxl Ud3xYizoPso9Gl4itvgZ95rxpeDg%3d /o3d 112
4/24/2021
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method I Option D
Date Submitted
12/16/2020
Date Validated
12/17/2020
Date Pending FBC Approval
12/26/2020
Date Approved
02/09/2021
Date Revised
04119/2021
Summary of Products
FL p Model, Number or Name
2569 1 Soprema Roof Underlayments
Limits of Use
Approved for use in NVMZ: No
Approved for use outside NVMZ: Yes
Impact Resistant: N/A
Design PreesYn: +N/A/-150
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.) The
design pressure noted herein pertains to underlayment systems
used beneath adhesive -se[ the systems. Refer to ER Section
5.8.3 for details.
Description
Self adhering roof undenayments
installation instructions
F 2569 R21 U 2020 a IA FINAL ER SOPREMA FL2569+
8 LQW
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third Party: Yes
!valuation Reports
FLI Sfi9 0.21 Al 2020 LZ 16 FINAL ER S PREMA FL2256Q
ULRgf
Created by Independent Third Party'. Yes
yvnl{St yy 2bU1 Bbv S[me Road-alleMnee iL ]2]99 prone 1550.87 :d]+
n,e R,. pf Fbnpa N an WEED ampbytt fJy'mpM IOaJ-201 a cYre of FbrW pnuicv. Staement A adyb`it 5te!emenl " d -d Statement
under Fkmda am, emLl Md. any In 0 i, mcd'aa. It y W od no Nam ~ a-maii, apela9 RItlad ,n -aabd'. tp i W..' fb n. Sand alen1p1,1[
mad by Mls adman, Iniabad, runtap: Me aeica by pndne a by Iradidonal mail. Ir yrw naw any q,,e a na. picric rbmb 850 •87 1395 'puraw,R to section ass 275(1).
rldnda SYtuta, d ,oriw Ooeber 1. 2012, ilcanae6l"mad .ride. USMer ass. F.s m,at onnnde the D biditment .nr en email address If tray raw onerre embus
pmYldd, may da used far debel oamn.n,obpn ymh rya aom. Npweven email Wdradea are YgObc —14 It ypu 0- rat "an M a y a damabm i aadma, picas'
Unn" Me DdpdnlnM[ WM an small atldR55 WmK Ur be made ivaliable tp ins Duda( rd dardrmlM II you am 2 I.,an. umaN clmp ass. F S. 1'.. d10 eas,
ii App,e,rai Arcepb:
CT CD 0 E3 E
Safe
https'/Nw.nondabuilding.orglprlpr_app_dtl aspxlparam=wGEVXOwtDgsKOFEnckB108EmI Ud3xYlioPso9G141tVgZ9SmpeDg%3d%3d 212
0
NEMO I etc.
Cerrlfware of Authoraaoon a32455
353 Christian Street, Unit g13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
'IN RFPC
Soprema, Inc. Evaluation Report S18030.06.09-R19
1640rue Haggerty FL2569-R21
Drummondville, Quebec 12C SP8 Canada Date of Issuance: 06/15/2009
(819)478-2400 Revision 19:12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 7"' Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Soprema Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1S07.1.1.
CONTNUEDCoMPuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FU$11) preceded by the words "NEMOI etc. Evaluated" may be
displayed in advertising literature. if any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166. Florida DCA ANE1983
d
si
t` C>' �
- :- � o• �-
niefxspn,Nsealappearmgwasauthwuedbv Roben
`•r^I'-,..... {-� ��
N ..r m, p E. on 12/16/2020 Thn dws Mt save as
., ..,,
an elatrOOCall1'Lgned dxument
CEIITINCATIDN M INDE/ENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest In any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity Involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC. LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof. is/was used for permitting or design guidance unless retained
specifically for that purpose.
02019 NEMO ETC, LLC
ONEMOJetc.
ROOFING COMPONENT EVALUATION:
a•
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced
by Soprema, have demonstrated compliance
with the following sections of the lei Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
SeWon
PrropS
StandardIRK
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1. 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3/ R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2/ R905.11.2
Material standard
ASTM D6163
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entkv
Examination
Reference
ERD (TST6049)
Wind Resistance
2778.07.05
07/15/2005
ERD (TST6049)
ASTM D1970/TA5110(QC)
531370.03.10-1-R1
04/07/2010
ERD(TST6D49)
FRSA/TR104-12(OH)
511150.05.09-R2
10/05/2010
ERD (TST6049)
ASTM D1970 (OH)
S37230.11.11
11/09/2011
ERD(TST6049)
ASTM 01970(M5)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
540540.02.13-1
02/19/2013
ERD (TST6049)
FRSA/TRI 04-12 (MS)
S43530.02.14-1-R1
02/21/2014
ERO (TST6049)
ASTM D1970(BC)
544870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D197014C)
S44870.04.14-3
D4/02/2014
ERD(TST6049)
ASTM D1970(OH)
S44870.04.14-1
D4/10/2014
ERD(TST6049)
ASTM D19701MS)
S44870.04.14-4
04/10/2014
ERO (TST6049)
ASTM D1970 (OH)
540540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC.SC7645.02.15
02/13/2015
ERD (TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
04/27/2015
ERD (TST6049)
Wind Resistance
SOPC-SC14045.05.17-R1
06/07/2017
M-D(CER1592)
HVH2 Compliance
18-0329.03
06/28/2018
ICC-ES(EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2027
NEMO (TST6049)
ASTM D1970 / TAS 110 (QC1
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-18-003.D8.18
09/27/2019
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
45-SOPC-18.002.05.19.A
05/31/2019
NEMO M6049)
Tensile Adhesion / Long Term Aging
4p-D0W-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underiayments)
4j-SOPC-20-SSUDL-01
12/16/2020
PRI ITST58781
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL. LLC (QUA9625)
Quality Control
Service Confirmation
D6/29/2020
UL, LL.C(QUA9625)
Quality Control
Florida SCIS
Current
Evaluation Report 518010.06.09-R19
NEMO ETC. LUC FL266"21
Cenifcee of AutlwntrIM0032455 71" EDITION(Z020) Far NON-HVH2 EVALUATION
soprema Roof Underiayments Revision 19: 1Page 2 20f 9
Page 9
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4NErmI etc.
PRODUCT DESCRIPTION:
Material
a1
Description
Standard
Lastobond TU HT
ASTM D1970 and
Gulfport. MS
self -adhering, non -woven polyester fabric
FRSA/TRI 09-19
surfaced, SOS modified bitumen roof
underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self -adhering, ran -woven polyester fabric
Underlaymem
FRSA/TRI 09-18
surfaced, SOS modified bitumen roof
underlayment
Lastobond Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SOS
modified bitumen roof underlayment available in
two widths; 36 and 45 inch
RESISTO SA SMOOTH PLY
ASTM D1970 Drummondville, QC
self -adhering, woven polyethylene surfaced, SOS
40
modified bitumen roof underlayment
Lastobond Shield HT
ASTM D1970 Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SOS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SOS
modified bitumen roof underlayment available In
two widths; 36 and 45 inch
Lastobond Pro HT-5
ASTM 01970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SOS modified bitumen roof
underlayment
EnvlroShield
ASTM D2970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SOS modified bitumen roof
underlayment
Lastobond 195
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Wadsworth, OH
surfaced, SOS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, sand -
Protection Sheet
Wadsworth, OH
surfaced, SOS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport. MS
surfaced, S85 modified bitumen roof
Wadsworth, OH
underlayment
Lashobond Smooth Seal ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced. film -
HT
Wadsworth, OH
surfaced, SOS modified bitumen roof
underlayment
Tri-Bulk Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film-
Underlayment
Wadsworth, OH
surfaced, SOS modified bitumen roof
underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
Smooth Seal HT
Wadsworth, OH
surfaced, SOS modified bitumen roof
underlayment
RESISTO L81236
ASTM D1970
Drummondville. QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SOS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILT Sand-R SA
ASTM D1970
Drummondville. QC
self -adhering, glass -mat reinforced, sand -
Shingle Underlayment
Gulfport. MS
surfaced, SOS modified bitumen roof
Wadsworth. OH
underlayment
NEMO ETC, LLC Evaluation Report 518010.06.09-R19
Cernlione OfAutlwdmbon 0324S5 T" EDITION (2020) FBC NON-HVH2 EVALUATION FL2569 R21
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 3 of 9
4.17
4.18
4.19
4.20
5.1
5.2
NNEIV101etc.
Product
Material
Plont(s)
Description
Standard
PrimeSource Grip -Rite
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand-
Eave & Valley Protector
Gulfport, MS
surfaced. SBS modified bitumen roof
Wadsworth, OH
underlayment
SRS TopShield ICE &
ASTM 01970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underayment
RESISTO LB1244 ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
Colphene FR GR ASTM D6163
Gulfport, MS
self -adhering, fiberglass reinforced, granule -
Wadsworth, OH
surfaced. 5B5 modified bitumen roof
underlayment
This is a building code evaluation. Neither NEMO ETC, LI C nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5,5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TAeta 1: Roor COVER OPTIONS
POCSOCON:
150r.2 j
1W.3
1502.4&&W.S
JW.T
1W..1141fdW9
Clay and Conc eta Tile
Maui
Shoe or
AWN
wood Shako or
Medlaldnl
AdlraM-
Undedayment
slate Type
sbw4ws
ARarh
Set
Pan4
shingles;
shlMn
Sys
Lastobond TU HT, Tn-Built S/A HT TU
Yes
Yes
Yes
Yes
Y25
Yes
IpMr
Underlayment
See 5.6.1
111,16113JItIJ/
Y
Lastobond Shield, Pro HT-N, RESISTO 5A
Yes
Na
No
No
No
Yp5
(p,nn1q' I131.1 !/
SMOOTH PLY 40
lom t IJI
Yes
Lastobond Shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
ilennmp3. IN? I I t/
In051 1 31
Yes
EnwroShleld
Yes
No
No
Yes
Yes
Yes
ip.,.,np. 1so1 I, 3l
MI 1131
Yes
Lastobond Eaves ProtertIOn Sheet,
Yes
No
No
NO
No Yes Imm ttnm. t5a! 1 I ! /
Lastobond 195
1
1 a90s 1.131
NEMO ETC LLC Evaluation Report 518010.06.09-1119
CemTade OtAvtewunt. 1324SS 7"'EDITION (2020)F9e NON-HVHZ EVALUATION FL2S6"21
Soprema Roof Underlayments Revolon 19. 12/25/2020
Page 4 of 9
NNEMOIetc.
TABLE 1: RDoF Com 0►nONs
FKie"lea: 1502.2 1i07.iAsialis]5024815a71 1501.) 1307.1i 1ia).e
Clay and Concrete Tee
Maul
State or
Urldaleynled"
Rskwon
Slate -type
Wood a
Mechanical
AdMalve,
hMle
�
Shklgkkes
Attach
Sat
Shingles
Lastobond ECO, RESISTO L61236, TRI-
BUILT Sand-R SA Shingle Underbyment,
yes
Grip -Rite Ea"& Valley Protector,
Yes
No
No
No
No
Yes
IpmnrIW) 113,
TopShleld ICE & WATER DEFENDER,
"INK 1111
RESISTO L81244
LaNpllord Smooth Sda1 HT, Tri-Built
yes
Smooth HT S/A Undertaymem, Grip-Rne
Yes
No
No
Yes
Yes
Yes
Ipmr nr,p. IW7113i
Smooth Seat HT
asns 11 31
yes
CAlphene FR OR
Yes
Yes
No
No
No
Yes
Ipm, nup, Isar 113 /
R90 1131
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment / tile -adhesive combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS'
Lastobond TU HT, Tri-Built S/A
HT TU Undertaymeit
5.7 Allowable Substrates:
Adhesive
Dupont 'T31e Bond" Roof Tile Adhesive"
ICP Adhesives and Sealants'Polyset• AH-160'
Florida Product Approval
FL22525
FL6332
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads fa project)
Underlaymem
Applicatlpn
TWO Printer Material(s)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
plywood' OSS or Southern Yellow Pine
HT-N, RESISTO SA SMOOTH PLY
Dads /
D41, Elastaol Stick,
(SYP)
40, Lastobond Shield HT,
sheathing
Elastaol Stick Zero
Lastobond Pro HT-S,
ASTM D41
structural concrete
EnviroShield, Lastobond TU HT,
(Optional) Elartocol
Dens Deck Prime or SECUROCK Gypsum-
Tri-Built S/A HT TU
Insulation
Stick Zero
Fiber Roof Board
Underlayment, Lastobond Eaves
Protection Sheet, Lastobond 195,
seH-
lartobond ECO, RESISTO L81236, adhering
TRI-BUILT Sand-R SA Shingle
Underlayment, Grip -Rite Eave &
Valley Protector, TopShield ICE &
Base Sheet
(Optional) Elastocoi
ASTM D226, Type II felt or Modified SOpra-
WATER DEFENDER, RESISTO
Stick Zero
G
LB1244, Lastobond Smooth Seal
NT, Tn-Built Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
Deck /
(Optional) ASTM
Plywood
D41
sheathing
ASTM D41
structural concrete
sec
Colphene FR GR
adhering
Insulation
(Optional) Elastool
Dens Deck Prime or SECUROCK Gypsum -
Stick Zero
Fiber Roof Board
[Optional) Elastaol
ASTM D226, Type 11 felt or Modified Sopra-
Base Sheet
Stick Zero
G
' Refer to Tile Monufocturels or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluatk3n Repo" S19010.06.09-R19
CM,pFatevf Audwus,fw#32455 7'"EDITION 12020)FBC NON-HVHZ EVALUATION FL2S69-R21
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 5 of 9
ONEMOletc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind bads for protect)
Underlayment
Application
Type
Primer
Material(s)
Lastobond TU HT, Tri-Built S/A HT
TU Underlayment, RESISTO
Existing sand -surfaced, glass -fiber surfaced,
LB1236, TRI-BUILT Sand-R SA
self-
Existing
EXTERIOR
mineral -surfaced or film -surfaced roof
Shingle Underlayment, Grip -Rite
adhering
substrate
PRIMER
PRIMER
underlayment*
Eave &Valley Protector or
TopShield ICE & WATER
DEFENDER
. Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability of on existing substrate to receive Lastobond TU HT, Tri-Built S/A HT
TU Underayment, RESISTO L81236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE &
WATER DEFENDER self-odhering underloyments, contact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions, but —for mechanically attached base sheets - not less than:
e FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Monuol, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
e Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile installation Manual, Sixth Edition, Appendix A, Table SA or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pressure = -67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment: Lastobond TU HT, Tri-Built 5/A HT TU Underlayment, self -adhered.
Evaluation Report S16010.06.09-1119
MEMO ETC, LLC FLZSWR21
certijrcore ofAurlmra0.a a32455 T"EDITION (2020J Fee NON-NVHZ EVALUATION
Pap Soprema Roof Underlaymems Revision 19: 1Pap 6 of 9
P6 of 9
"NEMOletc.
#3 Maximum Design Pressure = -120.0 psf:
Deck: Min. 15/32-inch APA-rated CDX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SA SMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
p4 Maximum Design Pressure = -150.0 psf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
#5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 3A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the
limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
R6 Maximum Design Pressure = -60.0 nsf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5-2) spaced 6.
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Underlayment: Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.9.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturer's installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Prepared Roof Cover
Maximum
Underlayment
Installation Type
Exposure (days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, RESISTO LB1236, TRI-
Mechanically
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector, TopShleld ICE
attached
30
& WATER DEFENDER or RESISTO LB1244
Adhesive -set tile roof
30
Lastobond TU HT, Tri-Built S/A HT TU Underlayment
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Mechanically
Lastobond Pro HT-5, Enviro5hield, Lastobond Smooth Seal HT, Tri-Buih Smooth HT S/A
attached
90
Underlayment or Grip -Rite Smooth Seal HT
Lastobond TU HT, Tri-Built 5/A HT TU Underlayment or Colphene FIR GR
Mechanically
attached
180
Evaluation Report S15010.06.09-R19
NEMO ET[, IlG
Ct�rute ejauMeriration#32a55 r-EOITION(20Z0)FBC NON-HVHZ EVALUATION F11564R21
Soprema Roof Underlayments Revision 19: 12/1S/20Z0
Page 7 of 9
ONEIVIOletc.
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE 1AMITAYMS FOR DIRER -DECK TILE INSTALIATIONs
Undedayment
Tile Profile
Staging Method
Mawnium Slope
Flat
Max. 10-tile stack
6:12
Lugged
Max. 30-tile stack
5:12
Lastobond TU HT, Tn-
Built S/A HT TU
Underlayment
Lugged
Max. 10-tile stack (bottom 2-tile stack shall be inverted,
followed by 8 tiles high on slope, as shown below)
6:12
, I
Flat
Max. 10-tile stack
5:12
Colphene FR GR
Lugged
Max. 1D-tile stack
6:12
6.1 Soprema Roof Underlayments shall be Installed in accordance with Soprema published installation instructions
subject to the Limitations set forth in Section S herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical support.
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Enviro5hield, Lastobond Eaves Protection Sheet,
Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO 181236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopSheld ICE & WATER DEFENDER, RESISTO L81244 or Colphene FR GR:
6.3.1 Non -Tile Applications:
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.3-3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226. Type II felt the base sheet
shall be fastened in accordance with FBC 1S07.1.1 or R905.1.1.
NEMO ETC, LLC Evaluation Report S38010.06.09-R79
Certi%icme o/AUMonmran a32455 7'" EDITION (20201 FBC NON-HVHZ EVALUATION FL2569.R21
soprema Roof Underlayments Revision 19: 12/15/Z020
Page 8 of 9
NNEIVIO I etc.
6.3.2 Tile Applications:
Limited to Lastobond TU HT, Tri-Built S/A HT TU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 62G20-3 CIA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALTY-AsSURANcE ENTITY:
UL. LLC-QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEW ETC, LLC Evaluation Report 538010.06.09-R19
Cernfcote of Au1h.1uen0-132455 7"EDITION 120201 FRC NON-NVHZ EVALUATION FL2569-RZ3
soprema Roof Underlayments Revision 19: 12/15/2020
Page 9 of 9