Loading...
HomeMy WebLinkAboutAPPROVED Architecture updated 50421Architectonic Inc April 16, 2021 St. Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Re: Roofing specification prepared for St. Lucie County Building Department for the structure located at, 650 N. Rock Road, Fort Pierce, FL, St. Lucie County, FL Manufacturer: JATAYLOR ROOFING Profiles: Edge-Loc 1.0 Aluminum, NOA# 18-1023.17 Code: FBC 2020; Section R 905 Wind Speed: 160 MPH; Ultimate Design Wind Speeds Exposure: B Mean Roof Height: 28' Maximum Pitch: 5/12 Minimum Required Design Pressure: Zone1: -51 Zone 2: -64.3 Zone3: -75.9 Maximum Uplift Pressure: -59.75 Zone 1 and -101 Zone 2 and 3 Fasteners: #10-13 x 1 Pancake Screws @ 16" O.C. Zone 1 nd 6.75" O.C. Zone 2 and 3 with 3/16" min. penetration Underlayment: Owens Corning Titanium PSU-30, Self -Adhered Underlayment, FL# 11602.1 Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" D.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 20 0 Florida Building Code, and the Manufacturer's recommendations. (D 3.Z 2Co 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1