HomeMy WebLinkAboutAPPROVED SOPREMA LASTOBOND ver2020ProfessionalBusiness
Regulation
aCSS Home Login Usar Registration Hat Thpks Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
41
Product Approval
r 4 USER: Public User
rodu I}PL Menu 7 P%Q Lor App 1 UYion Search a Appll bgrj List > Appllcatlon Dowl
: FL # FL2569-R2I
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Soprema, Inc. (Canada)
Address/Phone/Small 1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
mem ath i e u @ sap rema . ca
Authorized Signature Marc-Etfenne Mathieu
memathieu@isoprema. ca
Technical Representative Marc-Ftienne Mathieu
Address/Phone/Email 1688lean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu@soprema.ca
Quality Assurance Representative
Jean -Francois Cote, Ph.D.
Address/Phone/Email
1640 rue Haggarty
Drummondville
(888)811-3145
jfcote@soprema.ca
Category
Roofing
Subcategory
Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M. Nieminen
Evaluation Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
12/21/2023
Validated By
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL2569 R21 COI 2021 NIEM_;.JyEiV.f
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D4798
2011
ASTM D6163
2015
FM 4474
2011
FRSA/TRI Sixth Edition
2018
UL 1897
2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Data Submitted 1Z/16/2020
Data Validated 12/12/2020
Data Pending FBC Approval 12/26/2020
Data Approve ! O/09/2021
Summary of Product
PL #
Modal, Numher w Name
Description
2569.1
Soprema Roof Underlayment
Self adhering roof underlayment
Limits of Use
Approved for use in NVNZ: NO
Installation Instruction
Approved for use outside NVNZ: Yes
R21 otlf
Impact Resistant: N/A
Design Pressure: +N/A/-150
Other: 1.) Refer to ER Sedlon 5 for Limits of Use. 2.) The
design pressure noted herein pertains to undedayment systems
used beneath ac heslve-set ❑le systems. Refer to ER Section
5.8.3 for details.
Verified By: Robert Nieminen, P.E. PE-59166
Created by Independent Third! Party: Yes
Evaluation Reports
FU569 R21 AE 2020 12 16 FINAL ER SOP0.
RZLgd1
Created by Independent Third Party: Yes
Sdded U :: 201 slab smne Rear Rlub�a� a L 32399 idea 050 417-1824
Tla sNtt or mord. ban WEED employee - :: ad.1 Sunman :: AaexlblR bateren[:: Qyfynd Snammen[
add2¢ nhltli can be made available ra the public To determa
Product Appmvei P cev,a :
M ®® !^oi5
Credit Card
Safe
C]J
NEMO I etc.
Certhash, cd tadroractbn#32499
353 Christian Street, Unit #13
Oxford, Cr 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT
REPORTEVALUATION
Soprema, Inc. Evaluation Report S18010.06.09-1119
1640 rue Haggerty FL2569-R21
Drummondville, Quebec J2C SP8 Canada Date of Issuance: 06/15/2009
(819)478-2400 Revision 19: 12/16/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Cade. The product described herein has been evaluated for
compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Sopreme
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEW ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEW ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOI etc. Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 9.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration NO, 59166, Florida DCA ANEM3
5i?t
s;:
The nalmile anal appearing waz ouUgtlzed by Robert
cc' �.'�
Nieminm, P.E. on 11/16/2=. This does not bens as
.. .,...
an aeRmmally srcnea document.
QeTFIGTON OF INDEPENOENCF:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will R acquire, a financial interest In any company manufacturing or
distributing products it evaluates.
2. N EMO ETC, LLC is notowned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being Issued.
4. Robert Nieminen,P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nlemmen, P.E.are, In anyway, the Designer of Record for any
project on which this Evaluation Report, or previous wmions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
02039NEMOTTC, LLC
ONEIV10jetc.
ROOFING COMPONENT EVALUATION:
r
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Soprema Roof Underlayments, as produced by Soprema, have demonstrated compliance
with the following sections of the r Edition (2020) Florida Building Code through testing in accordance with the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
Section
Prom rN
nd r
year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1997
2015
1507.1.1, 1507.2.4, 1507.2.9.2
Material standard
ASTM D1970
2015
/ R905.1.1, R905.2.8.2
1507.3.3/ R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2/ P-%5.11.2
Material standard
ASTM D6163
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
Ln_ft
Examination
Reference
Date
FRO(TST(5U49)
Wind Resistance
2778.07.05
07/15/2005
ERD(TST6049)
ASTM D1970/TA5110(QQ
531370.03.30-1-R1
04/07/2010
FRO(TST6049)
FRSA/TRI 04-12(OH)
S11150.05.09-R2
10/05/201D
ERD (TST6049)
ASTM D1970 (OH)
S37210.11.11
1I/09/2011
ERD (TST6049)
ASTM D1970 (MS)
S37210.12.11
12/01/2011
ERD (TST6049)
ASTM D1970 (MS)
S40540.02.13-1
02/19/2013
Ego (TST6049)
FRSA/TRI 04-12(MS)
543530.02.14-1-RI
02/21/2014
ERD (TST6049)
ASTM D1970 (BC)
S44870.04.14-2
04/02/2014
ERD (TST6049)
ASTM D1970 (QC)
544870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
544870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970INS)
544870.04.144
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
540540.10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD(TST6049)
Accelerated Weathering
SOPC-SC8520.04.14
D4/27/2015
ERD(TST6049)
Wind Resistance
SOPC-SC34045.05.17-R1
06/07/2017
M-D(CER3592)
HVHZ Compliance
18-0329.03
06/28/2018
ICC-ES (EVL2396)
2015 IBC Compliance
ESR-1524
03/01/2017
NEMO(TST6049)
ASTM D1970/TA5110(QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Wind Resistance
4-SOPC-1&003.08.18
08/27/2018
NEMO (TST6049)
ASTM D4798/D3970 (OH & MS)
45-SOPC-18- 102.05.19A
05/31/2019
NEMO (TST6049)
Tensile Adhesion/Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing undedayments)
4f-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing undedayments)
41-SOPC-20SSUDL-01
12/16/2020
PRI(TST5878)
ASTM D1970(NIS)
SOP-064-02-01
12/03/2013
Soprema, Inc.(PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC(QUA9625)
Quality Control
MIA File No. R16814
12/101201S
UL, LLC(QUA9625)
Quality Control
MIA File No. R27605
05/08/2019
UL, LLC(QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC(QUA9625)
Quality Control
Florida BCIS
Current
NEMO ETC, Luc Eiralurtlon Report 518030.06.09-1119
Certihcata OfAutM1Mzetien M32455 T" EDITION(2020) FK NON-HVHZ EVALUATION Ft2569-R21
Soprema Renf Underlaymems Reulrlon 39:12/15/2020
Page 2 of 9
4.
4.
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
foNirguiniptir
PRODucr DESCRIPTION:
Product
Material
Standard
plain s
Description
Lastobond TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
FRSA/TRI09-18
surfaced, SBS modified bitumen roof
underlayment
Tr, -Built S/A HT TU
AS TM D3970 and
Gulfport, MS
self -adhering, non -woven polyester fabric
Underlayment
FR5A/TRI 09-18
surfaced, SBS modified bitumen roof
underlayment
;stobond Shield
ASTM D1970
Drummondville, QC
selfachenn& woven polyethylene surFaced, SBS
modified bitumen roof unclMaymentavailable in
two widths; 36 and 45 inch
RESISTO SASMOOTH PLY
ASTM D1970
Drummondville, QC
selfadhenng, woven polyethylene surfaced, SBS
40
modified bitumen roofunderlayment
Lastobond Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Lastobond Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylenesurfaced, SBS
modified bitumen roof underlayment available in
two widths; 36 and 45 Inch
Lastobond Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof
underlayment
Enviro5hield
ASTM D1970
Drummondville, QC
selfadhering, woven polyethylene surfaced, high
temperature, SOS modified bitumen roof
underlayment
La"bond195
ASTM D3970
Gulfport, MS
self -adhering, glass -mat reinforced, send -
Wadsworth, Of
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eaves
ASTM D1970
Gulfport, MS
self -adhering, glass-matreinforced, sand -
Protection Sheet
Wadsworth, Of
surfaced, SBS modified bitumen roof
underlayment
Lastobond Eco
ASTM D1970
Drummondville, QC
self-adhering,glass-mat reinforced, send -
Gulfport, MS
surfaced, Say modified bitumen roof
Wadsworth, Of
underlayment
Lastobond Smooth Seal
ASTMD1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -
HT
Wadsworth, Of
surfaced, SBS modified bitumen roof
underlayment
Tri-BuiltSmooth HT S/A
ASTM D1970
Gulfport, MS
self-adhering.glass-mat reinforced, film-
Undedayment
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
PrimeSource Grip-Rlte
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film.
Smooth Seal HT
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
RESISTO L81236
AS RA D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
TRI-BUILTSand-RSA
ASTM D1970
Drummondville, QC
self-adherin&Blau-matreinforced,send-
Shingle Underlayment
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
NEMO ere, ttC Evaluation Report 538010.05.MR19
rertsi aafAmarkanar 2aM 7'" EDITION (2020) FK NON-HVHZ WAWAMM F12569-R31
Sopmma Roof OnderlaymeMs Revbion 19: 12/19/SOSO
Page 3 of 9
4.17
4.18
4.19
4.20
ONEMOletic
Product
Material
Standard
plant(s)
Description
Orip Rite
ASTM DI9]0
Drummondville, QC
self-adhering,glass-matreinforced,sand-
EaveOSOurce
Eave &Valley Protector
Gulfport, MS
surfaced, S85 modified bitumen roof
Wadsworth, Of
underlayment
SRSTOPShi-ld ICE&
ASTM D1970
Drummondville, QC
self-Whering,glass-mat reinforced, sand -
WATER DEFENDER
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
RESISTO LB1244
ASTM D1970
Drummondville, QC
self-Wherin&glass-mat reinforcaQsand-
Gulfport, MS
surfaced, SBS modified bitumen roof
Wadsworth, OH
underlayment
[olphene FR OR
ASTM D6163
GUlf"n MS
self -adhering, fiberglass reinforced, gnmule�
Wadsworth, OH
surfaced, SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami -
Dade Counties).
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC Z603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE I: ROOF COVER OmONS
recseRpn:
ssoz.z
Lfe>.3
15a)Aa]SOI.s
1507.7
15078815079
ClAqftay and Concrete TIE
Mete)
Skteor
Mechanical
Adheshve-
OntledaymeM
SMr,gkslt
Shmt Type
Wood Shakes or
Austin
Set
PaMb
Shingles
Shingles
Shingles
Lastobond TU HT, Tn-Bulk S/A WTU
ye,,
Yes
Underlayment
Yes
Yes
See 5.6.1
Yes
Yes
Yes
Il^Imswps,sw3.v.tz/
5LL31
Lastobond Shield, Pro W-N, RFSISTO SA
Yes
SMOOTH PLY 40
Yes
NO
No
No
No
Yes
0o,muans, sZoL39/
e".)
Las[obond Sheld HT, Pro HT-5
yes
No
No
Yes
Yes
Yes
es
bNmeaPy3.3n.L14/
R W.LLN
EnvlroshieW
Yes
No
No
Yes
es
Y.
Yez
Yes
Iplms=1.39.i.t4/
0. M LL31
tastobond Eaves Protection Sheet,
Yes
lastobond 195
� y
No
No
No
No
Yes
ael..m 1w3.z.Ls/
0. R.L i1
NEMO ETC, LLC Evaluation Report 516030.06.09-R19
hrrAmteafAuMaimrion RR9ss TTM EDITION (2020) FBC NON-HVNZ EVALUATION FUS69-921
Sopmma Roof Underlayments Revlsion 19: IZ/15/2020
Page 4 of
CNIUCRAn ler,
_ r
TABLE I: ROOF COVER OPTIONS
wSestim:
SfOla
2SW.3
ITO 4a55p).5
150).)
15021 61507..9
Asphak
Clayand Concrete TherNo
settle
SNte or
Medlankal
Atlhesieo-
Untladaymam
Shingks
Slate -Type
Wood Shakes or
Attack
Set
Shingles
Shingles
Shingles
lastobond ECO, RESISTO LB3236, TRI-
BUILT Sand-R SA Shingle Undedayrn.m,
Grip -Rite Eave& Valley Protector,
Yes
No
No
No
Yes
Yes
ICE & WATER DEFENDER,RFSISTO
Omm MaTopShleld
LB1244
Lastobond Smooth Seat HT, Td-BuiltYes
Smooth HTS/A Underlament, Grip -Rite
Yes
No
No
Yes
Yes
Smooth Seal HT
pampnq tsozva/
axs'.131
Col hene FRGR
P
Yes
Yes
No
No
No
Yes
Yes
pamw+ss, l5mas3/
aaos.t.t.31
5.6.1 Adhesive -set tile is limited to use of the following Approved underlayment/tile-adhesive combinations.
TABLE IA:/PLOWABLE TILE ADHESIVE UNDERIAYMENT COMBIMMNO
Underlayment
i Adhesive
Florida Product Approval
Lastobond TU HT, Tri-Built S/A
HT TU Underlayment
Dupont "Tile Bond'" Roof Tile Adhesive"
FL22525
I ICP Adhesives and Sealants "Polyset•AH-16W
FL6332
5.7 Allowable Substrates:
TABLE2: SUeS nOPNONSFORADHEMDUNOERM MEMS
Underlayment
Application
Substrates (designed to meet Wind bads for project)
Type Primer Material(s)
Lastobond Shield, Lastobond Pro
(Optional) ASTM
HT-N, RESISTO SA SMOOTH PLY
Deck
D41, Elastocol Stick,
plywood, OSB or Southern Yellow Pine
40, Lastobond Shield HT,
sheathing
Elastocol Slick Zero
(SYP)
Lastobond Pro HT-S,
ASTM D41
Struc[u2l concrete
EnviroShield, Lastobond TU HT,
Insulation
(Optional) Elastocol
Dens Deck Prime or SECUROCK Gypsum-
Tri-Built S/A HT TU
Underlayment, Lastobond Eaves
Stick Zero
Fiber Roof Board
Protection Sheet, Lastobond 195,
Lastobond ECO, RESISTO LB3236,
seif-
self-
TRI-BUILT Send SA Shingle
g
Underlayment, Grip -Rite Eave &
Valley Protector, TopShleld ICE&
Base Sheet
(Optional) Elastocol
ASTM D226,Type llfelt orModified Sopra-
WATER DEFENDER, RESISTO
Stick Zero
G
LB1244, Lastobond Smooth Seal
HT, Tri-Buift Smooth HT S/A
Underlayment or Grip -Rite
Smooth Seal HT
(Optional)ASTM
Deck/
D41
Plywood
Sheathing
ASTM 041
structural concrete
self-
Insulation
(Optional) Elastocol
DenSDeCkPrimeorSECUROCKGypsum-
[olphene FIR GR
adhering
Stick Zero
Fiber Roof Board
Base Sheet
(Optional) Elastocol
ASTM D226,Type llfekorModified Soon.
Sticklero
G
1 Refer to Tile Manufacture/s or Adhesive Manufacturers Flonda Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 518010.01119
Cem#7tmv0AYtacaraa4a P32455 T"EDITION (2020)FOC NON-HVHZ EVALUATION F13569-1131
Soprcma Roof Underlavmems Revision 19: 12/15/2020
Page 5 of 9
ONFulch.,, I o+'
TABLE 2: SUBFI1ul 0P110115 FOR ADHERED UNOERIAYMEMS
Underlayment
Application
Substrates (designed to meet wind loads for project)
Type Primer Materli
Lastobond TU HT, Tri-Built S/A HT
TU Undedaymen4 RESISTO
LB1236, TRI-BUILT Sand -It SA
self-
Existing
RESISTO EXTERIOR
Existing sand -surfaced, glass -fiber surfaced,
Shingle Underlayment, Grip -Rite
adhering
substrate
PRIMER
mineral -surfaced or film -surfaced roof
Eave &Valley Protector or
underlayment'
TopShield ICE &WATER
DEFENDER
Final acceptance ofany existing substrate in a reroof (tear-offJ installation is at the discretion of the installer and the Authority
Having Jurisdiction. Should a question arise as to the suitability ofan existing substrote to receive Lastobond TU H, Td-BUIIt S/A HT
TU Underlaymen4 RESISTO LB3236, TRI-BUILTSond-R SA Shingle Under/oymen4 Grlp-Rite Eave & Valley Protector or Topshield ICE&
WATER DEFENDER sey-adhering underlaymenO, cantact RESISTO technical support.
5.7.1 Soprema recommends priming with Elastocol Stick, Elastocol 600C or RESISTO EXTERIOR PRIMER if the final roof
cover is not slated for installation within 24 hours.
5.7.2 Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation ofthe
self -adhering underlayment
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with
the manufacturers installation instructions, but —for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturers installation
instructions, but —for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A,
Table 1(for Two -Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and ClayRoofTile Installation Manual, Sixth Edition. The Maximum Design Pressure
lathe result of testingfor wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table IA or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -45.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)Elastocol Stick, Elastocol Stick Zero or RESISTO EXTERIOR PRIM ER
Underlayment Lastobond TU HT,Tri-Built S/A HT TU Underlayment, self -adhered.
#2 Maximum Design Pre =-67 5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: Elastocol Stick Zero
Underlayment Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered.
MEMO ETC, ac Evaluation Report 519010A6.09,119
Cariflo r.fAutbwaarlaa Mass T"EDITION (2020)FeC NON-HVHZ EVALUATION FUS69-R21
Soprema Roof Underlayments Revision 19: 12/15/2020
Page 6 of 9
#3 Maximum Design Pressure=-1200 osf: ONEMOjetc.
Deck: Min. 15/32-Inch APA-rated COX plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Base Ply: RESISTO SASMOOTH PLY 40, self -adhered.
Underlayment: Lastobond TU HIT, TrikBuilt S/A HT TU Underlayment, self -adhered.
#4 Maxi mum Design Pressure =.1500 osf:
Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to
satisfaction of Authority Having Jurisdiction.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment Lastobond TU HT,Tri-Built S/A HT TU Underlayment, self -adhered.
#5 All other direct -deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
5.8.3.2 Mechanically -Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1
design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones
shall employ an attachment density designed by a qualified design professional to resist the elevated pressure
criteria. Commonly used methods are AN51/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application
Standard RAS 117 and Roofing Application Standard RA5137. Assemblies marked with an asterisk- carry the
Lmiations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for
enhancements.
#6 Maximum Design Pressure =.600 at:
Deck: Min.19/32-inch plywood to meet project requirementstosatisfaction of Authority Having Jurisdiction.
Base Sheet: Modified Sopra-G mechanically attached with nails(FBC 1517.5.1)and tin caps FBC 1517.5.2)spaced b-
inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet.
Undedayment Lastobond TU HT, Tri-Built S/A HT TU Underlayment, self -adhered
5.8.4 For use over insulation or coverboard and under mechanically attached prepared roof coverings, underlayment
attachment shall be in accordance with the manufacturers installation instructions and attachment of the
insulation or coverboard shall be in accordance with the prepared roof covering manufacturer's Product
Approval,
5.9 EXaoSUfe Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Maximum
InstallationType
Exposure(days)
Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Ecc, RESISTO LB1236, TRI-
BUILT Sand-R SA Shingle Underlayment, Grip -Rite Cave& Valley Protector, TopShield ICE
Mechanical) y
30
& WATER DEFENDER or RESISTO LB3244
attached
Lastobond TU HT,Tri-Built S/A HT TU Underlayment
Adhesive -set the roof
30
system
Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT,
Lastobond Pro HT-S, EnviroShleld, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A
Mechanically
90
Underlayment or Grip -Rite Smooth Seal HT
attached
Lastobond TU HT,Tri-Built S/A HT TU Underlayment or Calphene FR GR
Mechanically
180
coached
NEMO ETC, LLC Evaluation Report 51801G.M.09-1119
Cortsk a nfAvd,4nm0oa M3E455 7`a EDITION (3U30)FBC NON-HVH2 EVALUATION FL2569-R21
5oproma Roof Underlayments Revision 19: 12/15/W20
Page 7 of 9
ONEmojetc.
5.10 Tile Slippage Limitations- When loading roof tiles on the underlayment in direct -deck the roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SUPPAGE LIMITATIONS FOR DIRER-DECRTne INSTALIATIONS
Underlayment
Tile ProRle
Staging Method
Maximum Slope
Fla[
Max. 10-tile stack
6:12
Lugged
Max. 10-tile ck
5:12
Lastobond TU HT, Tri-
Built S/AFIT TU
Underlayment
Lugged
Max. 10-tile stack (bottom 2-tile stack shall be Inverted,
followed by g ties high on slope, as shown below)
6:12
- )
5:12
Colphene FIRR
Flat
Max. 10-tile stack
Lugged
Max. 10-tile stack
6,12
6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation instructions
subject to the Limitations set forth In Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.2.1 Installation of RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or
TopShield ICE & WATER DEFENDER self -adhering underlayment in a reroof (tear -off) application atop an existing
underlayment (per Table 2) requires priming of the existing substrate with RESISTO EXTERIOR PRIMER. Final
acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the
Authority Having Jurisdiction. Should a question arise as to the suitability of an existing substrate to receive
RESISTO LB3236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley Protector or TopShield ICE
& WATER DEFENDER self -adhering underlayments, contact RESISTO technical su000rt.
6.3 Lastobond TU HT, Tri-Built S/A HT TU Underlayment, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA
SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, Enviro5hield, Lastobond Eaves Protection Sheet,
Lastobond 195, Lastobond Eve, Lastobond Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment, Grip -Rite
Smooth Seal HT, RESISTO LB3236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER, RESISTO LB1244 or Colphene FIR GR:
6.3.1 Non -Tile Applications
Shall be Installed In compliance with requirements for an approved self -adhering underlayment (ASTM D3970) In
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt the base sheet
shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
MEMO Rp, UC Evaluation Report 5M10.06a9-R19
an9komo)nurmnzmion ea2aa5 7' EDRION(2020) FBC NOWWH2 EVALUATION FL2569-R21
5oprema Roof Undedirrments Revision 19: 12/15/20M
P., 8 of
6.3.2 Tile Applications:®NEMOletc.
Limited to Lastobond TU HT, Tri-Built S/A HTTU Underlayment or Colphene FR GR.
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida
High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturers installation
instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. • .
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NWO ETC, LLC Evaluation Repon 518010.WA3R19
renPmm o)Authoraation 1324ss 7- EDITION (2020)FBC NON-HVHZ EVALUATION FQ569-RZI
Sopmma Roof Underlayments Revision 19: 12/25/2020
Page 9 of 9