HomeMy WebLinkAboutAPPROVED WESCOTT permit infoST. LUCIE "':t nub
Section C (Low Slope Roofl
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: Zone 2: _Zone 3: _
Max. Design Pressure, from the specific product approval
Deck:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. of Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_"
oc @ Lap, # Rows_ ® _ ac
Zone 1:_"
oc @ Lap, # Rows _ @ _ W
Zone 2:."
oc @ Lap, # Rows _ ® —" oc
Zone 3_"
oc @ Lap, # Rows— ® _" oo
Number of Fasteners Per Insulation Board:
Zone 1':_Zone 1:_Zone 2:—Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
01. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: JA TAYLOR ROOFING EDGE-LOC 1" STANDING SEAM
Notice of Acceptance Number: NOA:18-1 D23.17
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: -71 Zone 2e: -91 Zone 2n: Zone 2r: -91 Zane 3e: L1 Zone 3r:
Deck Type: IPLYWOOD
Type Underiayment: PEEL & STICK-SOPREMA LASTOBOND-FL#2569.1
Roof Sivpe:
� 12
Insulation:
Fire Barrier:
Ridge Venti[ation7 Fastener Type & 5paoing: 6" FIELD 14" PERIMETER, B❑ RiNG 5 NK NAILS
Adhesive Type:
Type Cap Sheet:
Mean RaofHeight: 15 F7 Roof Covering: METAL
Type & Size Drip
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values
are greaterthan or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: x = �3 MW =Aj� Product Approval M�
(Zone 2e: x = Mg = M,, Product Approval Mf
(Zone 2n: x )L = p =Man Product Approval Mf
(Zane 2r: x ;L = -- Mg: = Me Product Approval Mf
(Zone 3e: - x = " -- Mg: = M*, Product Approval Mf
{Zone 3r: ' x _ ,--J - Mg: = Mar Product Approval Mf_
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval Mr
r
Mr required Moment Resistance*
Mean Roof Height Roof Slope
1s,
20'
25'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
±26.4
28.0
29.4
30.5
32.4
7:12 24.4 25.9 27.1 28.2 30.Q
*Must be used in conjunction with a list of moment based the systems
• For Uplift based the systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RA5 12T
(Zone 1: x L =x W:=^---) -W: cos r =Frz Product Approval F'
(Zone 2e: x L =x W:=__j -W; cos r =Frze Product Approval F'
(Zone 2n: x L =x W:=_.--j -W: cos r =Fon Product Approval F'
(Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W:= ) -W: cos r 4r3e Product Approval F'
(Zone 3r: x L =x W:= ) -W; cos r =Fr3r Product Approval F'