HomeMy WebLinkAboutAPPROVED, Energy Calcs - 9 JuarezFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance
Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT
Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE (� `Q-Z
"\ Q
permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number.
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type01718.3 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int lnsul, Exterior
R=4.1 1478.30 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
;. NIA
R= ft2
4. Number of Bedrooms 1
d. NIA
R= ft2
5. Is this a worst case? Yes
11. Ceiling Types (1336.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above grade (ft2) 1306
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ftZ) 0
c. NIA
R= ft2
7. Windows(128.9 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Sgl, U=1.02 76.04 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.03 40.00 ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
29.0 SEER:14.00
o. U-Factor: S91, U=11.02 12.85 ft2
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth: 4.701 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.281
a. Electric Heat Pump
27.0 HSPF:8.20
8. Skylights Area
c. U-Factor.(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
9. Floor Types (1306.0 sqft.) Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ftz
b. Conservation features
EF: 0.600
b. NIA R= ft2
None
c. NIA R= ft2
16. Credits
None
Glass/Floor Area: 0.099 Total Proposed Modified
Loads: 41.30
PASS
Total Baseline Loads: 43.21
1 hereby certify that the plans and specifications covered by
Review of the plans andnj]L�E�
this calculation are in compliance with the Florida Energy
specifications covered by this
;. p
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
w
DATE: 1-12-20
this building will be inspected for,.�'71�-
compliance with Section 553.908
I hereby certify that this building, as designed,_ is i ompliance
with the Florida Energy CodeWE
Florida Statutes.
* ,
OWNER/A E T:
BUILDING OFFICIAL:
_
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403-3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/12/2021 1:40 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 IKIPIIT RI IMMARV CN1=ct[I ICT oocnOT
PROJECT
Title: WYNNE BUIDLING-THE CO Bedrooms: 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 1306
Lot #
Owner Name: WYNNE BUILDING CORP. Total Stories: 1
Block/Subdivision,
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, .Tip:
FT. PIERCE,
Family Type: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1306 10576.2
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfI ID Finished Cooled
Heated
1 MASTER BEDROO
234 1895.4 No 0
1
1 Yes
Yes
Yes
2 DEN
144 1166.4 No 0
1 Yes
Yes
Yes
3 SINK AREA
42 340.2 No 0
1 Yes
Yes
Yes
4 CLOSET
63 510.3 No 0
1 No
Yes
Yes
5 GREAT ROOM
452 3661.2 No 2
1 Yes
Yes
Yes
6 MASTER BATH
50 405 No 0
1 Yes
Yes
Yes
7 POWDER
25 202.5 No 0
1 No
Yes
Yes
8 KITCHEN
232 1879.2 Yes 0
1 Yes
Yes
Yes
9 LAUNDRY
40 324 No 0
1 No
Yes
Yes
10 STORAGE
24 192 No 0
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 31 ft 0
234 ft-
_
0 1
0
2 Slab -On -Grade Edge Insulatio
DEN 24 ft 0
144 ft
—
0 1
0
3 Slab -On -Grade Edge Insulatio
SINK AREA 7 ft 0
42 ft'
_
0 1
0
4 Slab -On -Grade Edge Insulatio
CLOSET 1 ft 0
63 fF
_
0 1
0
5 Slab -On -Grade Edge Insulatio
GREAT ROOM 32 ft 0
452 ft'
—
0 1
0
6 Slab -On -Grade Edge Insulatio
MASTER BATH 5 ft 0
50 ft'
_
0 1
0
7 Slab -On -Grade Edge Insulatio
POWDER 1 ft 0
25 ft'
_
0 1
0
1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab
-On -Grade Edge Insulatio KITCHEN 38 ft 0
232 ft-
0
1
0
9 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft 0
40 ft2
_
0
1
0
10SIab-On-Grade Edge Insulatio STORAGE 21 ft 0
24 ft2
_
0
0
1
ROOF
/
Roof Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1376 ft2 0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
`�
#
Type Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented 150
1306 ft2
N
N
CEILING
#
Ceiling Type Space R-Value
Ins Type
Area
Framing Free
Truss Type
1
Under Attic (Vented) MASTER BEDRO 30
Blown
234 ft2
0.1
Wood
2
Under Attic (Vented) DEN 30
Blown
144 ft2
0.1
Wood
3
Under Attic (Vented) SINK AREA 30
Blown
42 ft2
0.1
Wood
4
Under Attic (Vented) CLOSET 30
Blown
63 ft2
0.1
Wood
5
Under Attic (Vented) GREAT ROOM 30
Blown
452 ft2
0.1
Wood
6
Under Attic (Vented) MASTER BATH 30
Blown
50 ft2
0.1
Wood
7
Under Attic (Vented) POWDER 30
Blown
25 ft2
0.1
Wood
8
Under Attic (Vented) KITCHEN 30
Blown
232 ft2
0.1
Wood
9
Under Attic (Vented) LAUNDRY 30
Blown
40 IF
0.1
Wood
10
Under Attic (Vented) STORAGE 30
Blown
24 ft2
0.11
Wood
11
Knee Wall (Vented) GREAT ROOM 19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar Below
0
1
S=>N
Exterior Concrete Block - Int Ins6AASTER BE 4.1 18
0 8
1
145.5 ft2
0
0
0.3
0
2
W= E
Exterior Concrete Block - Int InSCAASTER BE 4.1 13
0 8
1
105.1 ft2
0
0
0.3
0
3
N=>S
Exterior Concrete Block - Int Insul DEN 4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
4
W=>E
Exterior Concrete Block - Int Insul DEN 4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
5
S=>N
Exterior Concrete Block -Int InsLSINK AREA 4.1 7
0 8
1
56.6 ft2
0
0
0.3
0
_ 6
N=>S
Exterior Concrete Block- Int InsGREAT ROO 4.1 22
0 8
1
177.8 ft2
0
0
0.3
0
_ 7
WEE
Exterior Concrete Block - Int InsGREAT ROO 4.1 10
0 8
1
80.8 fI
0
0
0.3
0
_ 8
S=>N
Exterior Concrete Block - Int InsMASTER BA 4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
_ 9
N=>S
Exterior Concrete Block - Int InsulKITCHEN 4.1 17
0 8
1
137.4 ft2
0
0
0.3
0
10
E=>W
Exterior Concrete Block - Int InsulKITCHEN 4.1 16
0 8
1
129.3 ft2
0
0
0.3
0
11
SIN
Exterior Concrete Block - Int InsulKITCHEN 4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRer202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPIIT SIIMIMARY CHPRIII IRT RI:PnaT
WALLS
Adjacent
Space Cavity Width
Height Sheathing Framing Solar Below
12 N=>S Exterior Concrete Block - Int InsulKITCHEN 4.1 35 8
_13 N=>S Exterior Concrete Block - Int InsuBTORAGE 4.0999 6 8
14 N=>S Exterior Concrete Block - Int InsuSTORAGE 4.0999 5 8
15 N=>S Garage Frame - Wood MASTER BE 11 30 8
1 282.9 ft- 0
48.0 ft' 0
40.0 ft' 0
0 240.0 ft= 0
0 0.3
0 0.3
0 0.3
0.23 0.3
0
0
0
0
DOORS
# Omt
Door Type Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1 E=>W
Insulated KITCHEN None
.32 3
6 8
20 f12
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
_ / Wall
V Omt ID Frame
Panes NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1 W=>E 2 Metal
2 W=>E 4 Metal
3 N=>S 6 Metal
4 W=>E 7 Metal
5 S=>N 8 Metal
6 E�W 10 Metal
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.03 0.27 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.26 N
32.4 ft' 1 ft 5 in 1 ft 5 in
18.4 ft' 1 ft 5 in 1 ft 5 in
18.4 ft' 1 It 5 in 1 It 5 in
40.0 ft2 12 ft 0 in 1 ft 5 in
6.9 fF 1 It 5 in 1 ft 5 in
12.8 ft' 1 ft 5 in 1 ft 5 in
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 280 ft-
280 ft- 35 ft
8.1 It
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000257 881.4 48.35 90.78 .0907 5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.2
27 kBtulhr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR
Block
Ducts
1 Central Unit/
Split Sing[ SEER: 14
29 kBtu/hr cfm 0.8
1
sys#1
1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
Tankless
Garage
0.6
1 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
n=
DUCTS
/ — Supply —
—
Return —
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat Cool
1 Attic
6 120 it-
Attic
45 it-
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablfe
Ceiling Fans:
1Thermostaf[t:l]N
Heating Lx1 Jan Feb
([1)
[x1 Mar
f 7
f 1 Apr
f
7 May
fXI (XI
f 7 Jun f 1 Jul
fX1
T 1 Aug
fX1
f 1 Sep
( j Oct
Nov
Dec
Venting [[ 11 Jan [[ ]] Feb
l l
[[�a77 Mar
[x1
[
]
[ j Jun [ 1 Jul
[ ] Au
[ ] Sep
L 1 OctetX
lxl
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling(WD) AM
PM
78
78
78
78
78
78
78
78
78 78
78
78
78
78 78
78
78
78
78
78
78 78
78
78
Cooling (WEH) AM
PM
78
78
78
78
78
78 78
78
78
78 78
78
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
PM
68
68
68
68
68
68 68
68
68
68 68
68
68
68
68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
68
68
68
68
68 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauft(8 lbs/sq.ft.
0 ft'
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft'
ft
0.3
DEN
Default(B lbs/sq.ft.
ft'
ft
0.3
SINKAREA
Default(8 lbs/sq.ft.
ft'
ft
0.3
CLOSET
Default(8 lbs/sq.ft.
ft'
ft
0.3
GREAT ROOM
Default(8 lbs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(S lbs/sq.ft.
ft'
ft
0.3
POWDER
Default(8 lbs/sq.ft.
ft'
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUNDRY
Default(8 lbs/sq.ft.
0 ft'
Oft
0.3
STORAGE
1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CORP. Jurisdiction:
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an y droppedceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned air
gnetl with the ar barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
above -garage
insulation.
maintain permanent contact with the underside of
and cantilevered
subfloor decking, or floor framing cavity insulation
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
Spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectricaVphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
Sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ]CC-400.
1/12/2021 1:40 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (fP)
7. Windows" Description
a. U-Factor. Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor. Sgl, U=1.03
SHGC: SHGC=0.27
c. U-Factor. Slit, U=1.02
SHGC: SHGC=0.26
d. U-Factor: WA
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): WA
SHGG(AVG): N/A
THE COTTAGE, FT. PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Detached
a. Concrete Block - Int Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
1
d. WA
Yes
11. Ceiling Type and insulation level
a. Under Attic (Vented)
1306
b. Knee Wall (Vented)
Area
c. N/A
76.04IF
12. Ducts, location & insulation level
a. Sup: Attic, Ret: Attic, AH: Attic
40.00 ft
13. Cooling systems
12.85 fe
a. Central Unit
ft'
4.701 it
0.281
Area
ft'
9. Floor Types Insulation Area
a. Slab -On Grade Edge Insulation R=0.0 1306.00 ft2
b. WA R= fN
c. WA R= fN
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featr ms
Builder Signature: Date: \A
Address of New Home: "\ �J V QC Q Z
_ City/FLZip:�S� ,
Insulation
Area
R=4.1
1478.30 fN
R=11.0
240.00 ft-
R=
ft.
R=
ft'
Insulation
Area
R=30.0
1306.00 ft'
R=19.0
30.00 ft'
R=
fN
R fts
6 120
kBtulhr Efficiency
29.0 SEER:14.00
kBtu/hr Efficiency
27.0 HSPF:8.20
Cap: 1 gallons
EF: 0.6
None
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
"'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/12/2021 1:40 PIA EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1