Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED, Manual J - 9 Juarez
Wrightstofto Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phor-:772-466-6799 Email: 4UICKCALCS@pOL.C,W Project• • For: WYNNE BUILDING CORP THE COTTAGE, FT. PIERCE, FL Notes: �~ C� Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 16327 Btuh Ducts 4013 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heating Cooling Area (ft2) 1306 1306 Volume (fF) 10579 10579 Air changeslhour 0.45 0.23 Equiv.AVF (cfm) 79 41 Heating Equipment Summary Make Carrier Trade CARRIER Model CHI4NBO3000GOA0 AHRI ref 9162387 Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 °F Backup: 8.2 HSPF 28000 Btuh @ 47°F 26 OF 967cim 0.048 cfmBtuh 0.50 in H2O Input = 5 kW, Output =18005 Btuh, 100 AFUE Job: Date: By. Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Dailyrange M Relative humidity 50 Moisture difference 61 gdlb Sensible Cooling Equipment Load Sizing Structure 15622 Bich Ducts 5251 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/sWn multiplier Equipmen le load 0.95 sensi 19734 Btuh Latent Cooling Equipment Load Sizing Structure 2094 Btuh Ducts 1524 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3618 Btuh Equipment Total Load (Sen+Lat) 23352 Btuh Req. total rapacity at 0.70 SHR 2.3 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond CH14NBO3000GOA0 Coil FX4DNB043L AHRi ref 9162387 Efficiency 11.5 EER,14 SEER Sensible cooling 20300 Btuh Latent cooling 8700 Btuh Total cooling 29000 Btuh Actual airflow 967 cfm Airflowfactor 0.047 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.85 Calculations approved byACCAto meetaii requirements of Manual J 8th Ed. wriigl'Atsa t- 2021-,iarr121321.40 Ri9Yt-Sute@Uriwrsa1201919.021RSUD8101 irL4.:rS Page 1 1wrgHsotHVACtiWYNNESUIDLING-THECOT7AGE.rup Calc=W8 FrorlDoor toes: SN! AL wrightsoftt Right -A) Worksheet JON Entire House °abe: eY QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@,40L.COM 1 Roam name Entire House MASTER BEDROOM 2 Bposedwall 145.0 ft 31.0 ft 3 Room height 8.1 ft 8.1 R headmol 4 5 Room dimenSions Room area 1306.0 V 13.0 x i8.0 ft 234.0 ft� Ty Construction U-value Or HTM Area {) Load Area (V) Load number (BWhIR2-°Fj (BWhiftTj or perimeter (ft) (Btuh) or perimeter (R) (Biuh) Heat Gool Gross N1P1S Heat Cool Gross NIPIS Heat Cool 6 L�! �—G 13A4ocs 0.143 n 4.00 2.19 446 427 1710 934 0 0 0 0 2gla ing,droutr, 1.040 n 29.12 21.68 18 0 537 400 0 0 0 0 13A-4ocs 0.143 e 4.00 2.19 162 129 516 282 0 0 0 0 2gla2ing,drota, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 1100 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 13A-4= 0.143 s 4,00 2.19 284 277 1107 605 146 146 584 319 G 2 gIwang, dr outr, 1.044 s 29,12 21.68 7 7 202 150 0 0 0 0 V[:93A-4ocs 0.143 w 4.00 2.19 284 192 767 419 105 7-3291 159 1A-clom 1270 w 35.56 34.77 41 41 1451 1419 0 0 0 0 1A hiom 1270 w 3556 61-76 18 $ 655 1139 0 0 0 0 C IA-hlom 16C30ml 1270 0.032 w 35.56 0.90 63.40 128 33 1306 5 1305 1162 1170 2072 1672 33 234 5 234 1162 210 2072 F 22A-tp1 0.989 27.69 0.00 1306 145 Ii 4015 0 234 31 8w 300 0 6 c)AEDexcursion s 3591 997 Envelopeloss(gain 13885 13393 3105 3847 12 a) Infiltration 2441 668 522 143 b) Room ventilation 0 0 0 0 13 Interralgalm O=pants@ 230 2 460 0 0 Applianoeslother 10001 0 Subtotal (lines 6 to 13) 16327 15522 3627 3990 Less e)L-mal load 0 0 0 0 Lees,iransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16327 15522 3627 3990 15 Duct loads 251% 34% 4013 5251 25% 34% 8921 1352 Total room toad 20340 20773 4518 5342 Airrequired(dm) 967 967 1215 249 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigiazsc rem 2021-Ar021321:40 A RightSuite@ Uriversal 201919.021 RSU08101 Page 1 lwrigMoftWAaWYNNEBUIDLiNG-THECOTTAGE.nq Calc=NETS Front Door faces: SW # - wrightsow RiOW@ Worksheet Job: Entire House D ft QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone; 772.466-6799 Emaii: QUICKCALCS@AOL.COM 1 Room name DEN SINKAREA 2 F�osed vQll 24.0 ft 7.0 & 3 Roam height 4 Roam dimensions 8.1 ft heatlmol 8.1 R heattoaol 5 Room area 12.0 x 144.0 ft' 12.0 ft 42.0 fe OD x 7.0 ft Ty Consirudion U-value Or HTM Area Lead I (f) Load number I (&uhflt{°F) (ewi, } or perimeter (ft) (6h�h} area (ft) Heat Cool Grass NlP/S Heat Coo! Gross N/P!S Heat Cool 6 V 13A-4ocs a143 n 4.00 2.19 97 97 369 213 0 0 0 0 G 2glaang,drouir, 13A-4ocs 1.040 n 29.12 21.68 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr ou7, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10:92 10,34 0 0 0 0 0 0 0 0 0 W 13A-4oCs �--G 0.143 s 4.00 2,19 0 0 fl 0 57 57 227 124 2 glazing, dr,,L&, 13A = 1.040 s 29.12 21.68 0.143 w 4.00 2.19 0 97 0 79 0 315 0 172 0 0 0 0 0 0 1A-Clom 1270 w 3556 $4.77 0 0 0 0 0 0 0 0 0 0 IA-hlom 1270 w 3556 61.76 18 3 $56 1139 0 0 0 0 1.4h1cm 1270 w 35.55 63.40 0 0 0 0 0 0 0 0 C 16C-30m1 F 22A-tpi 0.032 0:90 128 0.989 27.69 0.00 144 144 129 184 42 42 38 64 144 24 665 0 42 7 194 0 6 c)AEDe=rsion 574 -3 Envelope loss+aain 2154 2283 459 175 12 a) Infiltraflon I 404 ill1110 118 32 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianombther 0 0 Subtotal (lines6 tD 13) 25M 2394 576 207 Less edemal load 0 0 0 0 Lesstranster 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2556 2394 576 207 151 Dudtoads 25% 3eo/n 629 811 25% 34% 142 70 Total room load $187 3205 718 278 Air required (cfm) 152( 149 34 13 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed `�'}� aivrigh#sof`t� h.S2021-Jan 121321e2 ACACK Rigufle®Uriversat201919.021 RSU08101 Paget 1WrigtYsoftHVAG1WYNNEBUIDLING-THEdB COTrAGE.np Calc=MFrorltDoor faces: SW - wrightsoft° RighW@ Worksheet Job: Entire House Date: By. QUICK CALLS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore:772-466-6799 Email: QUICKCALCS@AOL.CDM 1 Room name CLOSET GREAT ROOM 2 Exposed wall p It 32.D ft 3 Room height 4 Room dimensions 8.1 ft heat/cool 8.1 ft heathml 5 Roam area 9.0 63.0 fF x 7.0 tt 452A ftz 1.0 x 452.0 It Ty Construction number U-value Or HTM (Btuhlftz-°F) (BbrhAt�j Area or ped e� (ft) Load (Shah) Area Load or perimeter (ft) (Bluh) Heat Cool Gross NlP/S Heat Cool Gross N1P/5 Heat Cool 6 13A4ocs �--G 2 0.143 n 4A0 219 0 D 0 0 178 160 640 3$D giaang, drout. 13A-4aa 1.040 n 29.12 21.68 0.143 a 4,00 2.19 0 0 0 0 0 0 18 0 537 400 2gWjng,drou1r, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 0 0 0 V1! 13A-flocs 0.143 s 4.00 2.19 0 0 0 0 0 0 �--G 2gla2jng,drout,, 13A4o 1.040 s 29.12 21.68 0.143 w 4.00 2.19 0 0 D 0 0 0 0 0 0 0 0 1A-clom 1270 w 35.56 34.77 0 0 0 0 0 0 0 81 41 40 161 88 1A-hlom 1270 w 35.56 61.76 0 0 0 0 0 41 1451 1419 IA-hlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 0 0 0 C 16C-30mi F 22A-1p1 0.032 0.90 128 63 63 56 81 452 452 406 579 0.989 27.69 0.00 63 0 0 0 452 32 886 0 6 c) AED exit rdon I I -1 2069 Envelope losslgain 56 80 4080 4903 12 a) Irttiltation 539 148 b) Room ventilation 0 0 Of 0 13 Internalgains: Ocaapants@ 230 0 p 2 460 Appliances/other p 0 Submtal(lines 6to13) 56 80 4619 5511 Lew e arnalload 0 0 0 0 Less tansfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 80 4619 5511 15 Dud loads 25% 34% 14 27 26% 34% 1135 1868 Total mom load 70 107 5274 7379 Air required (cfm) 3 5 4 343 Calculations approved b ACCA to meet all r ulrements of Manual J 8th Ed. �- wr�lhsts�vTt^ RightSutaUriversal201919.021 RSU08101 2021-iarr12132140 1Wrigi=ftWAC1WYNNESUIDLING-THECOTrAGE.np Calc=W8 Fror2Door faces: SW Page$ wrightsoft° Right J@ Worksheet Job. Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone:772-466-6799 Email: RUICKCALCS@,AOL.COM 1 Room name N44STER BATH POWDER 2 Eposed wall 5.0 It 0 ft 3 Room height 8.1 it heaticocl 8.1 ft heakool 4 Room dimensions 10.0 x 5.0 ft 5A x 5.0 ft 5 Room area 50.0 IF 25.0 1P Ty Construction U-value Or HTM Area Load number (BtithAP--°F) (Bhiit7R�) or perimeter (ft) (Btuh) or perimeteter (a) (Bluh) Heat Cool Gross NIPS Heat Cooi Gross N/P!S Heat Cool 6 W 13A-4ots 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 �G 2gla7ing,droup, 1.040 n 29.12 21.68 0 0 0 0 D 0 0 0 13A-40cs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glazing,drouT, 1.040 a 29.12 39,42 0 0 0 0 0 0 0 0 11 11 DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 tyJ 13A-0as 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 G 2 glazing, dr ou7, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Aciom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1270 w 3556 61.76 0 0 0 0 0 0 0 0 lXhlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 c 16C-3oml 0.032 - ox 128 50 50 45 64 25 25 22 32 F 22A 1pl 0.989 27.69 0.00 50 5 138 0 I 25 0 0 0 6 c) AM excursion -4 0 Envelope IossIgain 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Room*ntilation 0 0 0 0 13 Intemalgains: Ocupants@ 230 0 0 0 0 Appfianceslother 0 0 Subtotal (lines 6 to 13) 604 307 22 32 Less ademal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 604 307 22 32 15 Duct loads 25°/k 349/6 148 104 25%1 34°/a 6 11 Total room load 752 411 28 42 AirmgWred (tfm) 36 19 1 2 Calculations approved by_AC_CAto meet all requirements of Manual J 8th Ed. - wrlighitsoll� 2021-Jan-121321:40 RightSuteJUriversal201919,021 RSU08101 Page IW6gitsoftWACIWYNNEBUIDLtNG-THECOTTAGE.n,p Calc=MJ8 Frort Door faces: SW -F� wrightsoft° Right-JO Worksheet Job; Entire House Date. QUICK CALCS, INC. By, 317 ST. LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-468-6799 Email: QUICKCALCS a@ACL.COM 1 Room name KrCHEN LAUNDRY 2 En)osad v.911 3$.0 R 0 It 3 Room height 4 Room dimensions 8.1 It heat/cool 8.1 it heaV000l 5 Room area 1.0 x 2320 ft 232.0 ft 40A fF 4.0 x 10.0 It Ty Construction U-value Cr HTM Area Load Load number (Bh�tJR�"F� (Bhi } or perimeter (ft) (Bblh) or�perimeetter (ft) (Bh.ih) Heat Cool Gran NIPIS Heat Coos Gross NIPIS Hat Coal 6 VjJ 13A-0acs 0-143 n 4.00 2.19 138 138 551 301 0 0 0 0 _C 2glazing, drouir, ' 13A- ocs 1.040 n 29,12 21.68 0.143 a 4,00 2.19 0 130 0 97 0 387 0 211 0 0 0 0 0 0 ng, dr outr, ll—.DG 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 0 0 11 13 D0 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 u�! 13A- ocs �--G 0.143 s 4.00 2.19 41 41 162 89 0 0 D D 2 glazing, drautr, VE13A-0ocs 1.040 s 29.12 21.68 0,143 w 4.00 2.19 0 0 0 0 0 0 0 0 0 0 0 0 1Aa1am 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35-M 61.76 0 0 0 0 0 0 0 0 1.4h1om 1270 w 35M 63.40 0 0 0 0 0 0 0 0 c 16C-30mi 0.032 0.90 128 232 232 208 297 40 40 36 51 F 22A-ipl 0.989 27.69 0.00 232 38 1052 0 40 0 0 0 6 c) AM excursion 1 Envelope losslgain 2951 1570 36 51 12 a) Infiltration 640 175 0 0 b) Room ventilation 0 0 0 0 13 Intemalgains: 230 0 i 0 0 0 Appliances/other I 1000 0 Subtotal (lines 6 to 13) 3591 2745 36 51 Lessexbemalload 0 0 0 0 Lesstransfer 0 fl 0 0 Redislifbullon 0 0 0 0 14 Subtotal W91 2745 361 51 15 Dud loads 25% 349/o 883 931 25% 34% 9 17 Total room load 1 4474 3676 44251 5 68 Airrequired(cll 213 171 2 3 Calculafions approved b ACCA to meet all requirements of Manua[ J ft Ed. Aft�+- wrJlgia�ors� Righl-Sute®Universal 201919.021 RSUD8101 2021-Jan-121 :21 J8 1WrigMoftHVACIWYNNEBUIDLING-THEC07iAGE.rup Ca1c=MFrork Door toes: SW Page 5 wrightsoft REOW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore:772466-6799 Email QUICKCALCS al( AOL.COM 1 Room name STORAGE 2 Expo_edvrall 8.0 ft 3 Room height 8.1 ft heatf=l 4 Room dimensions 4.0 x 6.0 ft i 5 Room area 24.0 fF Ty Construction U-value Or HTM Area Load Load number (BtuhAl2F) (StuhflF�) or perimetr (ft) ors perimeter Heat Cool Gross MRS Heat Cool Gross N1P/S Heat Cool 6 V�f 13A4ocs �—G 0.143 n 4.00 2.19 32 32 130 71 2glaang,droutr, 13A-4ocs 1.040 0,143 n a 29.12 4.00 21B8 0 0 0 0 2.19 32 32 130 71 2 glazing, droutr, 1.040 a 29.12 39.42 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 Wj 13A4ocs 0.143 s 4.00 Z.19 0 0 0 0 —G 2glazing, droutr, 1.040 s 29.12 21.68 0 0 0 0 13A-4oas 0.143 w 4.00 2.19 0 0 0 0 1A-dom 1.270 w 3556 34.77 0 0 0 0 1A-hiom 1270 w 35,56 61.76 0 0 0 D 1A hlom 1270 w 35.56 63.40 0 0 0 0 C 16C-30mi 0.032 - 0.90 128 24 244 22 31 F 22A-1AI 01989 - 27.69 0.00 24 8 222 0 6 c) AED excursion -3 Envelope Io:Jgain 502 170 12 a) InfiirTation 135 37 b) Room ventilation 0 0 13 Internalgains: Oocupants@ 230 0 0 Applianceother 0 Subtotal (lines 6to 13) 637 207 Lessextemaiload 0 0 Less ti anslier 0 0 Redistribution 0 0 14 Subtotal 637 207 15 Duct loads 25% 29%j 157 60 Total room load 794 266 Air required (dm) 381 12 Calculations approved b ACCA to meet all requirements of Manual J ft Ed. .w'r�g��soTe� RightS[ite0 Urivei^sa1201919.022021-Jar~1213:21:401 RSU08101 Page 6 lWrighsoftHVAMWYNNEBUIDce LING-THECOTTAGE.np Calc=M18 FrontOoortas:5N1 + wrightsoft® Duct System Summary o Entire House By. QUICK CALCS, INC. 317 ST. LUCE LANE, FORT PIERCE, FL34946 Phcre:772-466-6799 Email: QUICKCALCS AOL.COM Projecta • For, WYNNE BUILDING CORD THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowestfriciion rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110 / 0.110 in H2O 0.080 i n/100ft 967 ci1T1 126 ft Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110 / 0.110 in H2O 0.080 in/100ft 967 ch Design Htg Cig Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (Cim) (cfm) FIR (in) (in) Mats Ln (ft) Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.01 Ox 0 VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 TO Ox 0 MFx 33.5 90.0 SO GREATROOM C 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREAT ROOM -A C 3689 137 172 0.080 8.0 OX 0 VIFx 16.1 70.0 KrrCHEN h 4474 213 171 0.080 7.0 Ox 0 VIFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox 0 VIFx 5.4 70.0 MASTERBATH h 752 36 19 0.080 4.0 Ox 0 VIFx 32.9 90.0 st1 MASTERSEDROOM C 2671 107 124 0.080 7.0 Ox0 VIFx 27.9 90.0 stl MASTER BEDROOM -A c 2671 107 124 0.080 7.0 Ox 0 VIFx 35.9 90.0 sit POWDER C 42 1 2 0.080 4.0 OxO VIFx 292 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 OxO VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 1 Ox 0 VIFx 11.2 70.0 Supply TrunDetail • Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (Cirri) FIR (fpm) (in) (in) Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VinIFIX ` Wrightsofi, 2021-Jar021321:41 '40a •� »�-. �.- Ri9t tSuGe®Uriversa1201919.0.21 RSU08101 Page 1 1WrigitoftWAaWYNNEBUIDLING-Tt1ECOTTAGE.rtp Calc=M18 Frort Door toes: SW Return Detail - Table Griile Htg Clg TEL Design Veloc Diam H x W Stucvioist Duct Name Size (in) (Cim) (Cfm) 00 FR (fpm) (in) (in) Opening (in) Malt Trunk rb1 Ox 0 967 967 0 0 0 01 Ox 0 ViFx wrightsoftm 2021-Jar}121321:41 RigItSute®Uriversa1201919.021 RSU08101 Paget 1WdghsoftHVACSWYNNEBUIDLING-lHEC,OTTAGE.rp Calc=MJ8 FrortDoorfaces:SW