HomeMy WebLinkAboutSurveyFLOOD ZONE AE
PATER MANAGEMENT TRACT 3
` R=345.00'
108
VACANT
D.E 0' D.E.1 0
1 o
I
I
I
I
I
PROPOSED
COVERED
LANAI
7R R7' 11 nn' 11.39'
11.39' I
I
I
o
o
I
1
1
�
o
1
10711.00'
o
6y ;
VACANT
PROPOSED
r-
Li
1
co
MODEL 4EBB/D
N
Eo
� F.F.E.=18.60
GARAGE F.F.E.=18.10
q a
EXISTING BUILDING i•
a
PAD EL=18.60 tO
r-CLLO
Z
�
I
PROPOSED
COVERED
I
ENTRY 4.33'
4.67' 4.67'
16.1 6'
71 14 nn'
16.16'
I I
PROPOSE
WATER SERVI�E
I I Lj N
_���L I
to
.ter R//it 16.61
INLET STRUCTURE a' I
GRATE EL. =16.07 10
I t6
PROPOSED v'
_CONCRETE' N —
DRIVEWKY.
— ��
4' CONC. 76
1°6:00' WALK 82
L=76.04'
�_. i; ;; ;a� GRAPHIC SCALE
,Q LOT 107 AREA SUMMARY IN SQUARE FEET
x SOD: 5716f 1. bwh - E0 tL
DRIVEWAY/WALKWAY: 671 t
M N. SET ACK REQ.
FR NT
SI ES LL EGADESCRIPTION
CN SIDES Being all of Lot 107, according to the plat of CREEKSIDE PLAT NO. 4, as
RE R recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida.
ZN .
T vA Containing 0.196 acres, more or less.
106
VACANT
ZONE
PROPOSED
SANITARY
SER112CE — — —
1W—
CONC'
pRIVAROAD-• `
'POTOMAC DRIVE FLOOD. ZONE AE 1 50.Oo R/W
0 - 6j
R .5Q0.00' 8 t,
—13E{�16FNNi4R1E--_-500�OQ�
SANITARY MANHOLE-16 34 2$
RIM EL=1:6.60: - 4
_PROPERTY ADDRESS
9308 POTOMAC DRIVE, FORT PIERCE, FLORIDA
GENERAL NOTES
1. The last dale of field work was 06-14-19
2. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of
the signing party or parties.
3. Reproductions of this map are not valid without the original signature and raised seal of a Florida Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights -of -way, easements of record, ownership, abandonment's, deed
restrictions, or Murphy Act Deeds. This information should be obtained through appropriate title verification.
5. All above ground fixed improvements, if any, have been located and shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.9, according to the Flood Insurance Rate Map, Community
Panel No. 12111CO170 J, effective date February 16, 2012. The exact designation can only be determined by an elevation certificate. No
additional search of the public records has been preformed. There may be additional map Amendments affecting this property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the East line of Lot 107 which bears South 05'28'50"
West and all bearings are relative thereto.
10. No easements are shown hereon other than those depicted on the plat. No search of the public records has been performed to find
additional easements that may exist.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
12. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior
to design or construction.
_ 13. All improvements relating to this plat are either proposed or under construction.
LEGEND 8t ABBREVIATIONS
BB DENOTES BEARING BASE O.S.T. DENOTES OPEN SPACE TRACT
CB DENOTES
DENOTES CHORD BEARING SDI TANCE DENOTES PROFESSIONAL LAND SURVEYOR(i DENOTES TRUCTURE P.S.M. DENOTES PROFESSIONAL SURVEYOR & PER
P.L.S.P.
I D.E. DENOTES DRAINAGE NTER NEASEMENT R DENOTES RADIUS
�J .....
. _ F.F.E. DENOTES FINISH FLOOR ELEVATION R/W DENOTES RIGHT OF WAY
U. E. DENOTES UTILITY ENT
FND DENOTES FOUND W.M.T. DENOTES WATER MANAGEMENT TRACT
-. IR/C DENOTES IRON ROD AND CAP A DENOTES INCLUDED ANGLE
-LB. DENOTES LICENSED BUSINESS -/� DENOTES DRAINAGE FLOW
Sjp:' N/D DENOTE DENOTES NAIL AND DISK ARC LENGTH DENOTES PROPOSED ELEVATION
THOMAS P. KIERNAN °00°°:., �'° DATE
Professional Surveyor & Mapper
Florida Certificate No. 6199
.. I CI CJtL I V—., tKz)w I -
CL OF HOMESTEAD �9'10 22 CL TRINITY CIRCA E
DRIVE L=.05' 80
t ° .PROPOSED 4' C0NC.'' WALK'
Boundary, Topographic &
Site Plan Survey -Lot 107
For: D. R. HORTON
CULPEPPER &
Date:12-17 20207
�
FB: N/-17-2020
FB: N A
TERPENING INC
SCALE 1 "=20'
2980 SOUTH 25th STREET . FORT PIERCE, FLORIDA 34981
DRAWN BY: RMR
PHONE 772-464-3537 . FAX T72-464-9497 . v w .ct-eng.com
FIELD: PK
STATE OF FLORIDA BOARD OF PROFESSIONAL
ENGINEERS AUTHORIZATION NO.4286