HomeMy WebLinkAboutAPPROVED APOC Peel and Stick (1)4/12/2021 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquOAT9TZVWgsdCpXv0foRuQtsEa8PjUsEAZvJ7tQHy3xg%3d%3d 1/2
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #FL26482-R6
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer APOC, Sub of Gardner-Gibson Inc.
Address/Phone/Email 4161 E. 7th Avenue
Tampa, FL 33605
(813) 248-2101
akhan@gardner-gibson.com
Authorized Signature Amir Khan
akhan@gardner-gibson.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the
Evaluation Report
Robert Nieminen
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL26482_R6_COI_2020_01_COI_NIEMINEN.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D1970 2015
ASTM D4533 (tear strength)2015
ASTM D4798 (weathering)2011
ASTM D4869 (liquid transmission)2016
ASTM D5035 (tensile)2011
FRSA/TRI, Sixth Edition 2018
TAS 103 2020
UL 1897 2015
Equivalence of Product Standards
Certified By
4/12/2021 Florida Building Code Online
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquOAT9TZVWgsdCpXv0foRuQtsEa8PjUsEAZvJ7tQHy3xg%3d%3d 2/2
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/17/2020
Date Validated 12/19/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
FL #Model, Number or Name Description
26482.1 Gardner Roof Underlayment (HVHZ)Roofing underlayments for use in FBC HVHZ jurisdictions
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to Section 5 for Limits of Use.
Installation Instructions
FL26482_R6_II_2020_12_17_FINAL_ER_APOC_FL26482-R6
(HVHZ).pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL26482_R6_AE_2020_12_17_FINAL_ER_APOC_FL26482-R6
(HVHZ).pdf
Created by Independent Third Party: Yes
26482.2 Gardner Roof Underlayments (NON-
HVHZ)
roofing underlayments for use in FBC non-HVHZ jurisdictions
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-135
Other: 1.) The design pressure noted herein pertains to
particular underlayment system for use under adhesive-set tile
roof systems. Refer to ER Section 5.8.3 for details. 2.) Refer to
ER Section 5 for Limits of Use.
Installation Instructions
FL26482_R6_II_2020_12_17_FINAL_ER_APOC_FL26482-R6
(NON-HVHZ).pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL26482_R6_AE_2020_12_17_FINAL_ER_APOC_FL26482-R6
(NON-HVHZ).pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
NEMO|etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION REPORT
APOC, sub of Gardner Asphalt Corp.
4161 E. 7th Avenue
Tampa, FL 33605
(813) 248-2101
Evaluation Report 1-GG-18-001.02.18-R4
FL26482-R6 (NON-HVHZ)
Date of Issuance: 02/27/2018
Revision 4: 12/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7th Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION: Gardner® Roof Underlayments, for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert
Nieminen, P.E. on 12/17/2020. This does not serve as
an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
©2019 NEMO ETC, LLC
NEMO|etc.
NEMO ETC, LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL26482-R6 (NON-HVHZ)
Gardner® Roof Underlayments; (813) 248-2101 Revision 4: 12/17/2020
Page 2 of 7
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Gardner® Roof Underlayments, as produced by Gardner Asphalt Corp., have
demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1504.3.1 Wind resistance UL1897 2015
1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1,
R905.2.8.2
Material standard ASTM D1970 2015
1507.1.1.1(2&3, Exception), 1507.1.1.1(5) /
R905.1.1.1(2&3, Exception), R905.1.1.1(5)
Tear strength ASTM D4533 2015
1507.1.1.1(2&3, Exception), 1507.1.1.1(5) /
R905.1.1.1(2&3, Exception), R905.1.1.1(5)
Tensile strength ASTM D5035 2011
1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES:
Entity Examination Reference Date
NEMO Traceability FBC Cross-Listing 12/10/2020
PRI (TST5878) ASTM D226 (physicals) GGI-176-02-01 9/26/2016
PRI (TST5878) ASTM D1970, D4798 GGI-178-02-01 10/24/2016
PRI (TST5878) ASTM D1970, D4798 GGI-194-02-01 4/19/2017
PRI (TST5878) FRSA/TRI, ASTM D4798, TAS 103 GGI-196-02-01 7/26/2017
PRI (TST5878) ASTM D226, D4533, D4869 GGI-132-02-06 12/11/2017
PRI (TST5878) ASTM D226, D4533, D4869 GGI-199-02-02 12/11/2017
PRI (TST5878) ASTM D1970, D4798 GGI-178-02-01 1/26/2018
PRI (TST5878) ASTM D4798 GGI-178-02-02 1/26/2018
PRI (TST5878) ASTM D1623, TAS 103 GGI-201-02-01 1/26/2018
PRI (TST5878) UL1897 GGI-212-02-01 5/9/2018
PRI (TST5878) Criticality, ASTM D1876 GGI-209-02-01 5/18/2018
PRI (TST5878) ASTM D903, D1970 GGI-211-02-01 6/6/2018
PRI (TST5878) ASTM D1623, TAS 103 GGI-202-02-01 8/9/2018
PRI (TST5878) UL1897 GGI-243-02-01 5/29/2019
PRI (TST5878) ASTM D1970 397T0016 12/16/2020
PRI (TST5878) ASTM D1623, D4798 397T0018 12/16/2020
UL, LLC. (QUA9625) Quality Assurance Service Confirmation 02/12/2020
UL, LLC. (QUA9625) Quality Assurance Florida BCIS Current
4. PRODUCT DESCRIPTION:
Product Material Standard Plant(s) Description
4.1 Gardner® Gard-Lock ASTM D1970 Springville,
AL
nominal 60-mil thick, glass-fiber reinforced, polymer
modified asphalt, granulated self-adhering underlayment
4.2 Weather-Armor® FT3
Tile Underlayment
FRSA/TRI 09-18 Springville,
AL
nominal 60-mil thick, self-adhering membrane of elastic
polymers, bitumen and polyester and glass
reinforcement
NEMO|etc.
NEMO ETC, LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL26482-R6 (NON-HVHZ)
Gardner® Roof Underlayments; (813) 248-2101 Revision 4: 12/17/2020
Page 3 of 7
Product Material Standard Plant(s) Description
4.3 Eagle-Armor by Apoc FRSA/TRI 09-18 Springville,
AL
nominal 60-mil thick, self-adhering membrane of elastic
polymers, bitumen and polyester and glass
reinforcement
4.4 TriBuilt Fleece Tile
Underlayment
FRSA/TRI 09-18 Springville,
AL
nominal 60-mil thick, self-adhering membrane of elastic
polymers, bitumen and polyester and glass
reinforcement
4.5 Weather-Armor® HT2
High Temp Premium
Roof Underlayment
ASTM D1970 Springville,
AL
nominal 60-mil thick, self-adhering membrane composed
of elastic polymers, bitumen, glass reinforcement and a
cross-laminated sheet surface, gray in color
4.6 Weather-Armor® HT3
High Temp Premium
Roof Underlayment
ASTM D1970 Springville,
AL
nominal 60-mil thick, self-adhering membrane composed
of elastic polymers, bitumen, glass reinforcement and a
cross-laminated sheet surface, black/yellow in color
4.7 Weather-Armor® SB-1
Self-Bond® Roof
Underlayment
ASTM D1970 Springville,
AL
nominal 60-mil thick, glass-fiber reinforced, polymer
modified asphalt, granulated self-adhering underlayment
4.8 TriBuilt Ice and Water
Underlayment
ASTM D1970 Springville,
AL
nominal 60-mil thick, glass-fiber reinforced, polymer
modified asphalt, granulated self-adhering underlayment
4.9 Gator-Skin™ Synthetic
Roof Underlayment
1507.1.1.1(2&3,
Exception), 1507.1.1.1(5)
/ R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
Hangzhou,
China
synthetic roof underlayment comprised of layers of
polyolefin film
4.10 Gator-Skin 10™
Synthetic Roof
Underlayment
1507.1.1.1(2&3,
Exception), 1507.1.1.1(5)
/ R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
Guijarat,
India
synthetic roof underlayment comprised of layers of
polypropylene film
4.11 Weather-Armor®
CrossOver CX-L
Premium Hybrid Roof
Underlayment
1507.1.1.1(2&3,
Exception), 1507.1.1.1(5)
/ R905.1.1.1(2&3,
Exception), R905.1.1.1(5)
Hangzhou,
China
hybrid underlayment comprised of two layers of
polyolefin and polyester synthetic fabric with a layer of
modified bitumen between the two
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Gardner® Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL26482-R6 (NON-HVHZ)
Gardner® Roof Underlayments; (813) 248-2101 Revision 4: 12/17/2020
Page 4 of 7
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section: 1507.2 1507.3 1507.4 &
1507.5 1507.7 1507.8 & 1507.9
Underlayment Asphalt
Shingles
Clay and Concrete Tile Metal
Panels or
Shingles
Slate or
Slate-Type
Shingles
Wood Shingles
or Shakes Mechanical
Attach
Adhesive-
Set
Gardner® Gard-Lock YES NO NO NO YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Weather-Armor® FT3 Tile Underlayment YES YES Yes
(See 5.6.1) YES YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Eagle-Armor by Apoc YES YES Yes
(See 5.6.1) YES YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
TriBuilt Fleece Tile Underlayment YES YES Yes
(See 5.6.1) YES YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Weather-Armor® HT2 High Temp Premium
Roof Underlayment YES NO NO YES YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Weather-Armor® HT3 High Temp Premium
Roof Underlayment YES NO NO YES YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
TriBuilt High Temp Metal Underlayment YES NO NO YES YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Weather-Armor® SB-1 Self-Bond® Roof
Underlayment YES NO NO NO YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
TriBuilt Ice and Water Underlayment YES NO NO NO YES
YES
(joint strips, 1507.1.1.3
/ R905.1.1.3)
Gator-Skin™ Synthetic Roof Underlayment YES NO NO YES YES NO
Gator-Skin 10™ Synthetic Roof
Underlayment YES NO NO YES YES NO
Weather-Armor® CrossOver CX-L Premium
Hybrid Roof Underlayment YES NO NO YES YES NO
5.6.1 Adhesive-set tile is limited to use of the following underlayment / tile-adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE-ADHESIVE COMBINATIONS1
Underlayment Adhesive Florida Product Approval
Weather-Armor® FT3 Tile
Underlayment, Eagle-Armor by Apoc or
TriBuilt Fleece Tile Underlayment
DAP “Touch ‘n Seal StormBond Roof Tile Adhesive” FL14506
Dupont “Tile Bond™ Roof Tile Adhesive” FL22525
ICP Adhesives “Polyset® AH-160” FL6332
1 Refer to Tile Manufacturer’s or Adhesive Manufacturer’s Florida Product Approval for Overturning Moment Resistance Performance.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL26482-R6 (NON-HVHZ)
Gardner® Roof Underlayments; (813) 248-2101 Revision 4: 12/17/2020
Page 5 of 7
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS
Underlayment Substrates
Gardner® Gard-Lock, Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc, TriBuilt Fleece Tile
Underlayment, Weather-Armor® HT2 High Temp Premium Roof Underlayment, Weather-Armor® HT3 High
Temp Premium Roof Underlayment, TriBuilt High Temp Metal Underlayment, Weather-Armor® SB-1 Self-
Bond® Roof Underlayment, TriBuilt Ice and Water Underlayment
Plywood
Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc, TriBuilt Fleece Tile Underlayment, Weather-
Armor® HT2 High Temp Premium Roof Underlayment, Weather-Armor® HT3 High Temp Premium Roof
Underlayment, TriBuilt High Temp Metal Underlayment
OSB
Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc, TriBuilt Fleece Tile Underlayment, Weather-
Armor® HT2 High Temp Premium Roof Underlayment, Weather-Armor® HT3 High Temp Premium Roof
Underlayment, TriBuilt High Temp Metal Underlayment. *Note: minimum 73°F ambient application
temperature for structural concrete.
Structural
concrete*
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with
the manufacturer’s installation instructions, but – for mechanically attached underlayments or base sheets - not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer’s installation
instructions, but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the
critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: None
Underlayment: Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile
Underlayment, self-adhered.
#2 Maximum Design Pressure = -135.0 psf:
Deck: Min. 19/32-inch APA span-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer: None.
Underlayment: Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile
Underlayment, self-adhered.
#3 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of -45 psf.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL26482-R6 (NON-HVHZ)
Gardner® Roof Underlayments; (813) 248-2101 Revision 4: 12/17/2020
Page 6 of 7
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover
Installation Type
Maximum
Exposure
(days)
Gator-Skin™ Synthetic Roof Underlayment, Gator-Skin 10™ Synthetic Roof
Underlayment, Weather-Armor® HT2 High Temp Premium Roof
Underlayment or Weather-Armor® CrossOver CX-L Premium Hybrid Roof
Underlayment
Mechanically attached 30
Gardner® Gard-Lock, Weather-Armor® SB-1 Self-Bond® Roof
Underlayment, TriBuilt Ice and Water Underlayment Mechanically attached 90
Weather-Armor® HT3 High Temp Premium Roof Underlayment, TriBuilt
High Temp Metal Underlayment Mechanically attached 180
Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc, TriBuilt
Fleece Tile Underlayment
Adhesive-set tile
(Polyset® AH-160) 30
Adhesive-set tile
(Tile Bond™ Roof Tile Adhesive or
Touch ‘n Seal StormBond Roof Tile
Adhesive)
90
Mechanically attached 180
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies, the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Weather-Armor® FT3 Tile Underlayment, Eagle-
Armor by Apoc, TriBuilt Fleece Tile Underlayment Flat or Lugged Max. 10-tile stack 6:12
6. INSTALLATION:
6.1 Gardner® Roof Underlayments shall be installed in accordance with Gardner® Asphalt Corp. published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Gardner® Gard-Lock, Weather-Armor® HT2 High Temp Premium Roof Underlayment, Weather-Armor® HT3 High
Temp Premium Roof Underlayment, TriBuilt High Temp Metal Underlayment, Weather-Armor® SB-1 Self-Bond®
Roof Underlayment or TriBuilt Ice and Water Underlayment:
6.3.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer’s installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.3.2 Multi-Ply Underlayment Systems:
Weather-Armor® HT3 High Temp Premium Roof Underlayment or TriBuilt High Temp Metal Underlayment
followed by Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment
(per Section 6.4) is allowable for use under mechanically attached prepared roof systems. Limits of use are those
associated with the top-layer material. This is not a requirement, but is allowable if a multi-ply underlayment
system is desired.
NEMO|etc.
NEMO ETC, LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL26482-R6 (NON-HVHZ)
Gardner® Roof Underlayments; (813) 248-2101 Revision 4: 12/17/2020
Page 7 of 7
6.4 Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile Underlayment:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed, and the manufacturer’s installation instructions.
When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer’s installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.5 Gator-Skin™ Synthetic Roof Underlayment, Gator-Skin 10™ Synthetic Roof Underlayment or Weather-Armor®
CrossOver CX-L Premium Hybrid Roof Underlayment:
6.5.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception),
1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer’s installation
instructions. FBC requirements take precedence over the manufacturer’s installation instructions.
6.5.2 Fasteners:
Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or FBC
Residential R905.1.1.1.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
9. QUALITY ASSURANCE ENTITY:
UL, LLC. (QUA9625); (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT –