Loading...
HomeMy WebLinkAboutAPPROVED St. Lucie County Roofing Permit Information SheetT. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5.6.7. Metal Roofs A, B, D 1,2,3,4,5,6,7 Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1, Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5, Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 Section A (General Information) Master Permit No. Process No. Contractors Name: The Roofing General LLC License # CCC1331769 Job Address 143 NE Jardain Rd. Port Saint Lucie FL 34983 0 Low Slope M Asphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) 500 _ ROOF CATEGORY ❑ Mechanically Fastened Tile ❑ Metal Panel/Shingles ❑ Prescriptive BUR-RAS 15C ROOF ROOF TYPE. ❑ Maintenance ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 15.25 ❑ Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ® Reroofing ❑ Recovering Total (SF) 20°25 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. 4�4" _ 4,,L.. ,-,... 2Z$.. 2.51• IQQa zQ•-tQ" 38°to-°° ,•,• 2a1Q" az•. ,. a..�.. 2XIO e t 4" 711w, LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: P (� Product Approval No.: 1(e5q "'R 27 w —zoo Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':'3? Zone 1: '(**y Zone 2: - egZone 3: 'qD Max. Design Pressure, from the specific product approval system: " 90.0 c c o �a n n G Zoe�e Deck: ,� Type: 51 CDX 1ly000d Gauge Thickness: Slope: 0.112 Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: P4 )y a I U-� S 1�V _-Se 1_F adhe'&4 Insulation Ilse Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_._." oc @ Lap, # Rows— @ "00 Zone 1:_..._." oc @ Lap, # Rows @"oC Zone 2:,r,._" oc @ Lap, # Rows @ "oc Zone 3:_.._." oc @ Lap, # Rows @ "oo Number of Fasteners Per Insulation Board: Zone 1': Zane 1: Zone 2: Zone 3:____. Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Section D (Steep Slope Roof System) Roof System Manufacturer: Tamko Shingles Notice of Acceptance Number: 18355-R6 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): .Zone 1:-7Zone 2e: -74Zone 2n:-108Zone 2r:-10$Zone 3e:-108 Zone 3r: -128 7Type S 8 CDX Plywood derlayment: peel and Stick Roof Siope:2 12ulation: N/A Fire Barrier: N/A Ridge Ventilation? Fastener Type & Spacing: 1 1/4 Nails 6 nails per Shingle Nailed every4" OC Adhesive Type: ^ N/A Type Cap Sheet: Mean Roof Height: _ '1i FT Roof Covering: Shingles Type & Size Drip 2X2 GALV DRIP EDGE Edge: Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: x A -_ Mg: -_ M', Product Approval M, (Zone 2e: x - = ) -ling: = M". Product Approval Mf (Zone 2n: x k ___,_,= w.) -� Mg: = Me Product Approval Mf (Zone 2r• x% _ )-Mg. =Mra, Product Approval Mf (Zone 3e: x), = -) ^ M9 = M,�,- Product Approval Mf, (Zone 3r: x ).-= ----- - Mgt = M,ar Product Approval Mf Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 *Must be used in conjunction with a list of moment based the systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: _x L =x W:= ) -W: cos r =Fri_ Product Approval F' (Zone 2e: x L_ =x W:= ) -W: cos r =F,2e- Product Approval F' (Zone 2n: x L =x W:= ) -W: - cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:= ) -W: cos r_ =F,3e Product Approval F' (Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope 6 Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity M, Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance M, Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application.