Loading...
HomeMy WebLinkAboutAPPROVED Design Pressure Report (Foley) - Master Craft Aluminum ProductsProperty Information Owner:Foley Address:5 Danzar Ft Pierce, Fl 34951 Building Information Wind Zone:160 MPH. Exposure Category:B Minimum Building Dimension:24 ft. Mean Roof Height:15 ft. Risk Category:II Design Pressure Calculations Opening Number Location Zone Device Width (in) Device Height (in) Device Elevation (ft) Max Positive Pressure (psf) Max Negative Pressure (psf) 1 Int 53 62 7 30.7 -33.5 2 Int 53 55 7 31.0 -33.7 3 Int 53 55 7 31.0 -33.7 4 End 108 84 7 28.6 -35.7 5 End 101 84 7 28.7 -36.0 6 Int 113 84 7 28.5 -31.3 7 Int 74 62 7 30.0 -32.8 8 Int 26 38 7 32.5 -35.2 9 Int 26 38 7 32.5 -35.2 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1