Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
A-1 Roof Trusses
4451 St Lucie Blvd
Site Information: Fort Pierce, FL 34946
Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE
Lot/Block: 77 Model: BERKSHIRE 2177
Address: 9716 STARBOARD DRIVE Subdivision:
City: County: State: FL
Name Address and License # of Structural Engineer of Record, If there is one, for the building.
Name: License #:
Address:
City:
General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading
Conditions):
Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products
Wind Code: ASCE 7-16 Wind Speed: 160
Roof Load: 37.0 psf Floor Load: 55.0 psf
This package includes 46 individual, dated Truss Design Drawings and 16 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules.
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
No.
Seq #
Truss Name
Date
1
2559
A01
3/10/21
13
2560
A13
3/10/21
25
2478
FL06E
3/10/21
2
2526
A02
3/10/21
14
2537
B01
3/10/21
26
2571
FL07
3/10/21
3
2527
A03
3/10/21
15
2538
B02
3/10/21
27
2480
FL07GE
3/10/21
4
2528
A04
3/10/21
16
2539
B03
3/10/21
28
j 2556
HJ7
3/10/21
5
2529
A05
3/10/21
17
2481
FG01
3/10/21
29
2557
HJ7A
3/10/21
6
2530
A06
3/10/21
18
2568
FG02
3/10/21
30
2558
HJ76
3/10/21
7
2531
A07
3/10/21
19
2577
FL02
3/10/21
31
2540
A
3/10/21
8
2532
A08
3/10/21
20
12473
FL02GE
3/10/21
32
2541
AA
3/10/21
9
2533
A09
3/10/21
21
2474
FL03
3/10121
33
12542
AB
3/10/21
10
2534
A10
3/10/21
22
2475
FL03GE
3/10/21
34
2543
J3
3/10/21
11
2535
1 All
3/10/21
23
2574
FL05
3/10/21
35
2544
J3A
3/10/21
12
12536
1 Al2
3/10/21
1 24
2477
FL06
3/10/21
36
2545
J313
3/10/21
The truss drawing(s) referenced have been prepared byAupine Engineered Products, inc. under myairect supervision based on the parameters provided byA- i RoofTrusses, russes, Lid.
Truss Design Engineer's Name: Rama Pranav Kristam
My license renewal date for the state of Florida is February 28,2023.
NOTE: The seal on these drawings indicate acceptance of professional engineering
responsibility solely forthe truss components shown.
The suitability and use of components for any particular building is the responsibility of the building
designer, perANSI/rPl-1 Sec. 2.
The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction
documents (also referred to at times as'Structural Engineering Documents') provided by the Building
Designer indicating the mature and characterof the work.
The design criteria therein have been transferred to Rama Pranav Kristam PE by [Al Roof Trusses or
specific location]. These TDDs (also referred to at times as'Structural Delegated'
Engineering Documents') are specialty structural component designs and maybe part of the project's
deferred orphaned submittals. Asa Truss Design Engineer (i.e., Specialty
Engineer), the seal here and on the TDD represents an acceptance of professional engineering
responsibilityforthe design of the single Truss depicted on the TDD only. The Building Designer is
responsible for and shall coordinate and review the TDDs for
compatibility with theirwritten engineering requirements. Please review all TDDs and all related notes.
AIV���'''
E N 5
No. 88 6 * "
ATE OF .:
Rama Pranav Kristam, P.E.
4451 St Lucie Blvd. Suite 201
Fort Pierce, FL 34946
Page 1 of 2
RE: Job CRMSBSB2
No.
Seq #
Truss Name
Date
37
2546
J5
3/10/21
38
2547
J5A
3/10/21
39
2548
J513
3/10/21
40
2549
J7
3/10/21
41
2550
J7B
3/10/21
42
2551
Vol
3/10/21
43
2552
V02
3/10/21
44
2553
V03
3/10/21
45
2554
VO4
3/10/21
46
2555
V05
3/10/21
47
STDL01
STD. DETAIL
3/10/21
48
STDL02
STD. DETAIL
3/10/21
49
STDL03
STD. DETAIL
3/10/21
50
STDL04
STD. DETAIL
3/10/21
51
STDL05
STD. DETAIL
3/10/21
52
STDL06
STD. DETAIL
3/10/21
53
STDL07
STD. DETAIL
3/10/21
54
STDL08
STD. DETAIL
3/10/21
55
STDL09
STD. DETAIL
3/10/21
56
STDL10
STD. DETAIL
3/10/21
57
STDL11
STD. DETAIL
3/10/21
58
STDL12
STD. DETAIL
3/10/21
59
STDL13
STD, DETAIL
3/10/21
60
STDL14
STD. DETAIL
3/10/21
61
STDL15
STD. DETAIL
I 3/10/21
62
STDL16
STD. DETAIL
3/10/21
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3
These truss designs rely on lumber values established by others.
Page 2 of 2
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
Job I r iuwb i yNc v..tty I riy vuf ivrcvc i
CRMSBSB2 A01 HIPS 1 1 2559
T
s4:
1 ate' A
256# 189# 189# 189# 189# 189#
+ 189# + 1891 + 189 + + 189 + + 189#4 + 256#
---- 7'0-3/8"
7' 20'8" -}- 7' --�{
oH0710 =5X6 =H0710(++) aH0710
C D EF G
6
12(87R
=5X1H(
(a)
(a)
N M L K J I
III1.5X4=H0510=4X10=7X10=H0510 1111.5X4
34'8"
W/4
�---- 7'0-3/8" 3/8 2, 2, I 2, 2, 1/F 2, 2, 2, 2, 2'0-3/8" i
440# 109 109# 109 109# 10909# 109t 109# 10) 109# 462#
Loading Criteria (psr) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.47 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30; T2,T3 2x6 SP 2400f-2.OE;
Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:;
B2 2x6 SP 2400f-2.OE;
Webs: 2x4 SP #3; W2 2x4 SP #2;
Lt Wedge: 2x4 SP #3;Rt Wedge: 2x4 SP #3;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.46 to 62 plf at 7.00
TC: From 31 plf at 7.00 to 31 plf at 27.67
TC: From 62 pif at 27.67 to 62 pif at 34.67
BC: From 14 pif at 0.00 to 14 plf at 7.03
BC: From 7 plf at 7.03 to 7 pif at 27.64
BC: From 14 plf at 27.64 to 14 plf at 34.67
TC: 256 lb Conc. Load at 7.03,27.64
TC: 189 lb Conc. Load at 9.06,11.06,13.06,15.06
17.06,17.60,19.60,21.60,23.60,25.60
BC: 440 lb Conc. Load at 7.03
BC: 109 lb Conc. Load at 9.06,11.06,13.06,15.06
17.06,17.60,19.60,21.60,23.60,25.60
BC: 462 lb Conc. Load at 27.64
Plating Notes
(++) - This plate works for both joints covered.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 27.67
BC 41 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
fl
37R) '-
v
1
Code / Misc Criteria Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code:FBC 7th Ed. 2020 Res. PP Deflection in loc L/defl
L/# Gravity Non -Gravity
TPI Std: 2014 VERT(LL): -0.572 E 721
360 Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Varies by Ld C se6RT(CL): 0.805 E 512
240 B 3208 /- /- /- /2456 /-
FT/RT:10(0)/10(10) HORZ(LL):-0.161 I -
- H 3129 /- /- /- 12380 /-
Plate Type(s): HORZ(TL): 0.228 1
Wind reactions based on MWFRS
WAVE, HS
Creep Factor: 2.0
B Br Width = 3.5 Min Re 2.7
9 q
Max TC CSI: 0.847
H Brg Width = 3.5 Min Req = 2.6
Max BC CSI: 0.963
Bearings B & H are a rigid surface.
Max Web CSI: 0.804
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 184.1 Ibs
A - B 39 - 36 E - F 6820 - 8828
VIEW Ver: 20.02.0 AA.1209.11
B - C 4894 -6361 F - G 6820 -8828
Wind
C - D 6757 - 8753 G - H 4929 - 6410
D - E 6817 - 8825
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - N 5605 -4302 K - J 5634 -4331
N - M 5587 -4298 J - 1 5632 -4331
M - L 5588 -4298 1 - H 5652 -4336
L - K 8838 - 6856
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
N - C 496 -103 E - K 1161 - 988
C - L 3545 - 2751 K - G 3563 - 2772
L - D 1188 -1022 G -1 534 -123
D-K 44 -14
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Co-hoht n 2016 A-1 Roof Tmsses - Renrnduotinn of this dnnument in env form. is nrohlhited without the written -mission of A-1 Roof Tnisses
joo I russ I r uss I ype Qty r-ly uJ/ I ulzuz t
CRMSBSB2 A02 HIPS 1 1 1 2526
�I
j- 9' -}- - 168" -i- 9' —�
1Vf16"
%7X6(R) 1111.5X4 =H0308 N7X6(R)
C D E F
1111.5X3 =3X6 =3X8 =3X6 1111.5X3
34'8"
1
_m
In
=4X4(A2) I
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.154 D
999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.291 D
999 240 B 1413 /- I- /844 /937 /214
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.057 H
- - G 1321 /- /- /737 /864 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.108 H
Wind reactions based on MWFRS
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 2.0
B Brg Width = 3.5 Min Req = 1.7
NCBCLL: 10.00
TCDL: 5.0 sf
p
Max TC CSI: 0577
G Brg Width = 3.5 Min Req = 1.6
Load Duration: 1.25
BCDL: 4.2 psf
.
Bearings B & G are a rigid surface.
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.954
C&C Dist a: 3.47 ft
Max Web CSI: 0.699
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Loc. from endwall: not in 9.00
Wgt: 156.8 Ibs
GCpi: 0.18
A - B 39 0 D - E 2782 -2553
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 2217 -2335 E - F 2782 -2553
Lumber
C - D 2782 -2553 F - G 2224 -2346
Top chord: 2x4 SP M-30;
Bot chord: 2x4 SP #2;
Maximum Bot Chord Forces Per Ply (Ibs)
Webs: 2x4 SP #3;
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - L 1987 -1861 J - 1 2004 -1825
L - K 1992 -1859 I - H -1825
(a) Continuous lateral restraint equally spaced on
K - J 1992 -1859 H - G 1999 1999 -1827
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacirl oc) Start(ft) End(ft)
TC 24 9.00 25.67
BC 55 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C -L 312 0 J -F 625 -824
C- J 639 - 849 H- F 314 0
D - J 830 - 508
"`WARNING"" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvnnht n 201
a A-1 Ronf Tnissn., — Rnnrnrl—m— of thi., Annimant in anv fnrm i., nrohihited withniit tha written nertnlccinn of A-1 Rnnf Tri ac
moo
CRMSBSB2
iivaa
A03
yP.
HIPS
—y y
1 1
2527
1p4,,
11'
12'8" 11'
III 1.5X3
=3X4=4X6 =3X8=4X6=3X4
34'8"
4X4(A2)
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.149 E
999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.266 E
999 240 B 1413 /- /- /855 /935 /254
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.050 1
- - H 1321 /- /- 1747 /862 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.096 1
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2
B Br Width = 3.5 Min Re 1.7
g q
NCBCLL: 10.00 TCDL: 5.0 psf
0.
Max TC CSI: 0.571
H BrWidth = 3.5 Min Re4 1.6
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.984
Bearings B & H are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
Max Web CSI: 0.678
Maximum Top Chord Forces Per Ply (Ibs)
C&C Dist a: 3.47 ft
Chords Tens.Comp. Chords Tens. Comp.
Loc. from endwall: not in 9.00
Wgt: 173. E Ibs
GCpi: 0.18
A - B 39 0 E - F 2170 -2067
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 2135 -2427 F - G 1951 -2085
Lumber
C - D 1947 -2077 G - H 2147 -2443
D - E 2170 - 2067
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30; B2 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Purlins
B - M 2106 -1839 K - J 1798 -1469
In lieu of structural panels or rigid ceiling use purlins
M - L 1792 -1510 J - 1 1798 -1469
to laterally brace chords as follows:
L - K 1792 -1510 I - H 2124 -1812
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.00 23.67
BC 72 0.15 34.52
Maximum Web Forces Per Ply (Ibs)
Apply purlins to any chords above or below fillers
Webs Tens.Comp. Webs Tens. Comp.
at 24" OC unless shown otherwise above.
C - M 421 - 357 K - F 356 - 512
Wind
D-M 412 -116 F-1 416 -127
Wind loads based on MWFRS with additional C&C
D - K 364 -525 1- G 435 -372
member design.
E - K 651 -413
Wind loading based on both gable and hip roof types
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvnnht f) 2016 A-1 Rnnf Tmcsrs - Rpnrndnrtinn of thi, dnnum,nt in anv form is nmhihited withI the wdfi--i-inn of A-1 Rnnf Tni«r+.a
goo I russ I I runs I ype try I rly U6/ I U/LUG I
CRMSBSB2 A04 HIPS 1 1 1 2528
W—UP11
W4,
13' — 8'8" i 13
:o5X6 =3X4 =5X6
E F G
1111.5X3 =3X6=3X8 =3X8=3X6 III1.5X3
34'8"
4X4(A2)
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity
Non
-Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.134 F 999 360
Loc R+ / R- / Rh
/ Rw
/ U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.254 F 999 240
B 1413 /- I-
/859
/665 /294
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.058 J - -
1 1321 /- /-
/752
/614 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.110 J
Wind reactions based on
MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 20.
B Br Width = 3.5
9
Min Re 1.7
q
NCBCLL: 10.00 TCDL: 5.0 psf
p
Max TC CSI: 0.506
I Brg Width = 3.5
Min Req = 1.6
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.988
Bearings B & I are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Max Web CSI: 0.541
Maximum Top Chord Forces Per
Ply (Ibs)
C&C Dist a: 3.47 ft
Chords Tens.Comp.
Chords
Tens. Comp.
Loc. from endwall: not in 9.00
Wgt: 183.4 Ibs
GCpi: 0.18
A - B 39 0
E - F
1620 -1642
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 1871 -2427
F - G
1618 -1644
Lumber
C - D 1663 -1916
G - H
1680 -1918
D - E 1681 -1846
H - 1
1885 - 2444
Top chord: 2x4 SP #2;
Bat chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bat Chord Forces Per
Ply (Ibs)
Chords Tens.Comp.
Chords
Tens. Comp.
Purlins
B - O 2093 -1594
L - K
2109 -1568
In lieu of structural panels or rigid ceiling use purlins
O - N 2091 -1596
K - J
2109 -1568
to laterally brace chords as follows:
N - M 2091 -1596
J - 1
2111 -1567
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 13.00 21.67
M - L 1717 -1318
BC 71 0.15 34.52
Apply purlins to any chords above or below fillers
Maximum Web Forces Per Ply (Ibs)
at 24" OC unless shown otherwise above.
Webs Tens.Comp.
Webs
Tens. Comp.
Loading
O- C 203 0
F- L
276 -195
Truss passed check for 20 psf additional bottom chord
C - M 438 -525
L - G
487 - 374
live load in areas with 42%high x 24"-wide clearance.
E - M 485 -364
L - H
458 - 544
M- F 281 -199
H- J
206 0
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Knstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRO, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvnnht n 2016 A-1 Rnnf — Ranrn —.mn of thi., dnnimnnt in anv form Is nmhlhitnd without thn wnttnn nermicainn of A-1 Rnnf Tm��es
JVu ivaa i ivaa frPc utrY r iY ��r ivlc�c i
CRMSBSB2 A05 HIPS 1 1
2529
4- n
W4„
15' 4'8" i 15'
=5X6
1111.5X3 =3X6 =3X4 =3X8 =3X6 1111.5X3
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
SCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.47 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.00 19.67
BC 70 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
34'8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.126 M 999 36
VERT(CL): 0.239 M 999 24
HORZ(LL): 0.057 J - -
HORZ(TL): 0.109 J
Creep Factor: 2.0
Max TC CSI: 0.679
Max BC CSI: 0.984
Max Web CSI: 0.301
Wgt: 179.2 Ibs
VIEW Ver: 20.02.01A.1209.11
=4X4(A2)
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1413 A /-
/858 /662 /333
1 1321 /- /-
/751 /611 /-
Wind reactions based on
MWFRS
B Brg Width = 3.5
Min Req = 1.7
1 Brg Width = 3.5
Min Req = 1.6
Bearings B & I are a rigid
surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A- B 39 0
E- F 1381 -1490
B - C 1642 - 2396
F - G 1412 -1741
C - D 1382 -1773
G - H 1382 -1767
D - E 1414 -1756
H -1 1653 -2411
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - O 2056 -1375 L - K 2070 -1346
O - N 2054 -1377 K - J 2070 -1346
N - M 2054 -1377 J - 1 2072 -1345
M - L 1488 - 924
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
O- C 268 0 L- F 424 - 249
C - M 518 - 647 L - H 539 - 668
E- M 422 - 206 H- J 272 0
E - L 214 -210
*'WARNING'" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvriaht n 2016 A-1 Roof Tni«P, — Renrodnntion of thi, dornment in nov form is nrohlhited Mthout the waft- nertni-ion of A-1 Roof Tme
dw i i ��� I yN� .sty ry .,.,� 1 u,��4
CRMSBSB2 A06 HIPS 1 1 2530
17'
F
17'
1111.5X3 =3X6 =3X8 =3X6 III1.5X3
34'8"
I A"
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.117 K
999 360 Loc R+ I R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.221 K
999 240 B 1413 /- /- /850 /645 /374
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.057 1
- - H 1321 /- /- /743 /594 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.109 1
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 2
B Br Width = 3.5 Min Re 1.7
g q
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0. 0.645
H BrWidth = 3.5 Min Req 1.6
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.997
Bearings B & H are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Max Web CSI: 0.735
Maximum Top Chord Forces Per Ply (Ibs)
C&C Dist a: 3.47 ft
Chords Tens.Comp. Chords Tens. Comp.
Loc. from endwall: not in 9.00
Wgt: 163. 8 Ibs
GCpi: 0.18
A - B 39 0 E - F 1092 -1568
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 1339 -2345 F - G 1058 -1614
Lumber
C - D 1046 -1613 G - H 1364 -2358
D - E 1086 -1604
Top chord: 2x4 SP M-30; T2,T3 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - M 1999 -1088 K - J 2011 -1068
(a) Continuous lateral restraint equally spaced on
M - L 1997 -1089 J - 1 2011 -1068
member.
L - K 1997 -1089 1 - H 2O14 -1067
Plating Notes
(**) 1 plate(s) require special positioning. Refer to
Maximum Web Forces Per Ply (Ibs)
scaled plate plot details for special positioning
Webs Tens.Comp. Webs Tens. Comp.
requirements.
M- C 306 0 K- G 633 -771
Purlins
C- K 616 -755 G- 1 308 0
E - K 842 - 505
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spaclr in oc) Start(ft) End(ft)
BC 70 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvr ,ht n 201a A-1 Rnnf Tnr,sea - Renrn —Amn of thi.., dnr .nt in — form ii, nrnhihited without the wdlten nermiczion of A-1 RoofTo—,
goo ��' �� yN, ,,y y 6 ,
CRMSBSB2 A07 COMN 1 1
2531
:pi
17'4" -i 17'4"
1111.SX3 =3X6 =3X8 =3X6 III1.5X3
34'8"
W4,
Loading Criteria (psf Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl
L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.117 K 999
360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.221 K 999
240 B 1413 /- /- /850 /659 /380
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
1-101 L): 0.057 1 -
- H 1321 /- /- /742 /608 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.109 1
Wind reactions based on MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
B Brg Width = 3.5 Min Req = 1.7
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.645
H Br q
Width = 3.5 Min Re 1.6
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.995
Bearings B & H are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to In
Max Web CSI: 0.733
Maximum Top Chord Forces Per Ply (Ibs)
C&C Dist a: 3.47 ft
Chords Tens.Comp. Chords Tens, Comp.
Loc. from endwall: not in 9.00
Wgt: 163. 8 Ibs
GCpi: 0.18
A - B 39 0 E - F 1127 -1568
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 1371 -2345 F - G 1094 -1614
Lumber
C - D 1081 -1613 G - H 1400 -2358
D-E 1121 -1604
Top chord: 2x4 SP M-30; T2,T3 2x4 SP 42;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - M 1999 -1114 K - J 2011 -1100
(a) Continuous lateral restraint equally spaced on
M - L 1997 -1115 J - 1 2011 -1100
member.
L - K 1997 - 11 15 1 - H 2O14 -1099
Plating Notes
(") 1 plate(s) require special positioning. Refer to
Maximum Web Forces Per Ply (Ibs)
scaled plate plot details for special positioning
Webs Tens.Comp. Webs Tens. Comp.
requirements.
M - C 306 0 K - G 628 - 772
Purlins
C- K 610 -755 G- 1 308 0
E - K 843 - 504
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 69 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
*`WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. Ti defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in Ti
C ..nnht n 2n1a A-1 Rnnf Tni<cev — Renrodii 1— of thi., dnriimant in anv fort, i., nrnhlhited withrnit the wnft,, hP .,. i n of A-1 Rnnf T--ec.
auu r i uss i t uss i ype sty rry V3/ I V/LUL I
2532
CRMSBSB2 A08 HIPS 1 1
¢ILN.
j- 17' 8 7- 17'
F
III1.5X3 =3X6 =3X8 =3X6 III1.5X3
34,8„
A2)
IVA"
1P/16"
y11
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.118 L 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.223 L 999 240
B 1411 /- /- /851 /644 /398
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.057 J - -
H 1411 /- /- /851 /643 /-
EXP: C Kzt: NA
Des Ld: 37.00
Plate Type(s):
HORZ(TL): 0.108 J
Wind reactions based on MWFRS
s S
Mean Height: 25.00 ft
WAVE, HS
Creep Factor: 2.0
B Br Width = Min 1.7
9 q =
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.643
H Brg Width = 3.5 Min Req = 1.7
Load Duration: 1.25 BCDL: 4.2 psf
"
Max BC CSI: 0.964
Bearings B & H are a rigid surface.
Spacing: 24.0 MWFRS Parallel Dist: h/2 to It
C&C Dist a: 3.47 ft
Max Web CSI: 0.711
Maximum Top Chord Forces Per Ply (Ibs)
Loc. from endwall: not in 9.00
Chords Tens.Comp. Chords Tens, Comp.
Wgt: 166.E Ibs
GCpi: 0.18
A - B 39 0 E - F 1082 -1600
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 1331 -2340 F - G 1042 -1609
Lumber
C - D 1042 -1609 G - H 1331 -2340
D- E 1082 -1600 H- 1 39 0
Top chord: 2x4 SP M-30; T2 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Bracing
B - N 199-99L - K 1992 -992
(a) Continuous lateral restraint equally spaced on
N - M 19922 - 998 K - J 1992 - 992
member.
M - L 1992 - 998 J - H 1995 - 991
Plating Notes
(") 2 plate(s) require special positioning. Refer to
Maximum Web Forces Per Ply (Ibs)
scaled plate plot details for special positioning
Webs Tens.Comp. Webs Tens. Comp.
requirements.
N- C 306 0 L- G 615 -753
Purlins
C- L 615 -753 G- J 306 0
In lieu of structural panels or rigid ceiling use purlins
E - L 834 -489
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 72 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent orthe Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvnnht n 201
6 A-1 Roof Tnissas - Ranmrtn&,,n of this do—mant in anv form is nrohihitad wilhnnt the —nan nannission of A-1 Rnnf T.—s
J00 liuoa II— iyNc
CRMSBSB2 A09 HIPS
4-Htl5•
IV/A„
15'
1 1 1
4'8" 15' -
=5X6
1111.5X3 =3X6=3X4 =3X8=3X6 III1.5X3
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.47 ft
Loc. from endwall: not in 9.00
GCp1: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 15.00 19.67
BC 73 0.15 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
34'8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.128 N 999 36,
VERT(CL): 0.240 N 999 24,
HORZ(LL): 0.057 K - -
HORZ(TL): 0.108 K
Creep Factor: 2.0
Max TC CSI: 0.634
Max BC CSI: 0.987
Max Web CSI: 0.300
Wgt: 179.2 Ibs
VIEW Ver: 20.02.01A.1209.11
2533
1V/A„
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1411 /- /-
/859 /661 /357
1 1411 /- /-
/859 /661 /-
Wind reactions based on MWFRS
B Brg Width = 3.5
Min Req = 1.7
1 Brg Width = 3.5
Min Req = 1.7
Bearings B & I are a rigid
surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
A-B 39 0
F-G 1401 -1720
B - C 1635 - 2392
G - H 1373 -1761
C - D 1377 -1768
H - 1 1634 - 2392
D- E 1405 -1727
I- J 39 0
E - F 1376 -1485
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - P 2053 -1286 M - L 2051 -1282
P - O 2051 -1287 L - K 2051 -1282
O - N 2051 -1287 K - I 2053 -1281
N - M 1483 - 832
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
P- C 268 0 M- F 423 - 239
C - N 520 - 649 M - H 523 - 652
E- N 421 - 205 H- K 269 0
E - M 213 - 209
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Convdoht n 2nte A-1 Roof Tm,ue, - R--d-1— of fhia doraimont in anv form i.e nrohihit,d without tho wnnen onof A-1 Roof Tnii i, c
Joo I runs 1 Fuss I ype l,lLy rly US/lU/LULI
CRMSBSB2 A10 HIPS 1 1 2534
4-112"
I- - 13' , i 8'8" 13'
1V/16"
o5X6 =3X4 5X6
E F G
1111.5X3 =3X6=3X8 =3X8=3X6 1111.5X3
34'8"
A2)
1P/A„
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity
Non
-Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.135 F 999 360
Loc R+ / R- / Rh
/ Rw
/.0 / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.255 F 999 240
B 1411 /- /-
/860
/663 /317
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.058 L - -
J 1411 /- /-
/860
/663 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.110 L
Wind reactions based on
MWFRS
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
B Brg Width = 3.5
Min Req = 1.7
NCBCLL: 10.00 TCDL: 5.0 psf
Max TC CSI: 0.494
J Brg Width = 3.5
Min Req = 1.7
Load Duration: 1.25 BCDL: 4.2 psf
Max BC CSI: 0.989
Bearings B & J are a rigid surface.
Spacing: 24.0 " MWFRS Parallel Dist: h/2 to h
Max Web CSI: 0.523
Maximum Top Chord Forces Per
Ply (Ibs)
C&C Dist a: 3.47 ft
Chords Tens.Comp.
Chords
Tens. Comp.
Loc. from endwall: not in 9.00
Wgt: 184.8 Ibs
GCpi: 0.18
A - B 39 0
F - G
1612 -1638
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
B - C 1863 -2422
G - H
1672 -1841
Lumber
C - D 1654 -1911
H - 1
1654 -1911
D - E 1672 -1841
1 - J
1863 -2422
Top chord: 2x4 SP #2;
E - F 1612 -1638
J - K
39 0
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per
Ply (Ibs)
Purlins
Chords Tens.Comp.
Chords
Tens. Comp.
In lieu of structural panels or rigid ceiling use purlins
B - Q 2089 -1504
N - M
2087 -1501
to laterally brace chords as follows:
Q - P 2087 -1506
M - L
2087 -1501
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 13.00 21.67
P - O 2087 -1506
L - J
2089 -1499
BC 74 0.15 34.52
O - N 1712 -1224
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
Webs
Tens. Comp.
Loading
Truss passed check for 20 psf additional bottom chord
Q - C 203 0
F - N
278 -195
live load in areas with 42"-high x 24"-wide clearance.
C - O 439 -526
N - G
484 -362
E - O 484 - 362
N - 1
440 - 526
Wind
O- F 278 -196
1- L
203 0
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Knstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Coo-oht n 20 Jr, A-1 Roof — Rpnrndnrtinn of thi, dnriim,nt in — form is nroh'ihil,d without the wditpn nermicsion of A-1 Roof Tm .—,
CRMSBSB2 Al HIPS 1 1
2535
oT
1 N� all
a -sty^
i 11' 12'8"
�5X6 =3X4 =5X10
D E F
12 _ Ill1.5X3=3X6=4X10
IP/4" 11'l-1/2"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.47 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30; T3 2x4 SP #2;
Bot chord: 2x4 SP M-30; B3 2x4 SP #2;
Webs: 2x4 SP #3; W6 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 11.00 23.67
BC 56 0.15 11.12
BC 57 11.12 18.65
BC 76 18.73 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
7'5-1/2"
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/l0(10)
Plate Type(s):
WAVE, HS
'34,8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.393 E 999 36,
VERT(CL): 0.742 E 556 241
HORZ(LL): 0.236 J - -
HORZ(TL): 0.444 J
Creep Factor: 2.0
Max TC CSI: 0.614
Max BC CSI: 0.977
Max Web CSI: 0.961
Wgt: 176.4 Ibs
VIEW Ver: 20.02.01A.1209.11
A2 )
16-1" 45-9/411
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1414 /- /- /854 /933 /278
H 1411 /- /- /855 /932 /-
Wind reactions based on MWFRS
B Erg Width = 3.5 Min Req = 1.6
H Brg Width = 3.5 Min Req = 1.7
Bearings B & H are a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 39 0 E- F 4002 -4241
B - C 3765 -4419 F - G 1927 -2062
C - D 3428 - 3931 G - H 2134 - 2425
D- E 3232 - 3527 H- 1 39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - N 4001 - 3289 K - J 25 - 26
N - L 4271 - 3603 J - H 2106 -1751
M-K 25 -26
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - N
552 - 397
L - J
2014 -1574
D - N
1286 - 916
L - F
2811 - 2541
N - E
1011 - 795
J - F
713 - 729
E - L
348 -116
J - G
438 - 376
L-M
27 -3
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-I. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C-nnht n 2016 A-1 Rnnf Tni ., - RenrnduNinn of thi[ don-ent in -form. i., nrohlbited without the written nenniccion of A-1 Rnnf Tmc
duu ,,ubb12 Itubb ,yye vety rry u�r ,urcuc,
CRMSBSB2 AHIPS 1 1 2536
i 9'i 168" i9' ®'{
05X6 =3X8=H03081111.5X3 6X12
C D E F G
■I
i+t
27-T
1 if2• �.
a a 1111.5X4 =3X6 =3X8
12
1'5-9/1
9'1-1/2"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.47 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30; T2 2x4 SP #2;
Bot chord: 2x4 SP M-30; B3,B4 2x4 SP #2;
Webs: 2x4 SP #3; W7 2x4 SP #2;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 9.00 25.67
BC 58 0.15 9.12
BC 54 9.12 18.73
BC 58 18.73 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
�MWI
9'5-1/2"
fl
A2)
1
16'1" .1'5-94"
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code:FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.509 F 811 360
Loc R+ / R- / Rh / Rw / U / RL
B 1414 /- /- /844 /935 /238
Rep Factors Used: Yes
VERT(CL): 0.958 F 430 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.258 J - -
H 1411 /- /- /845 /935 1-
Plate Type(s):
HORZ(TL): 0.486 J
Wind reactions based on MWFRS
WAVE, HS
Creep Factor: 2.0
B Brg Width = 3.5 Min Req = 1.6
Max TC CSI: 0.908
H Brg Width = 3.5 Min Req = 1.7
Max BC CSI: 0.996
Bearings B & H are a rigid surface.
Max Web CSI: 0.784
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 168.0 Ibs
A-B 39 0 E -F 5178 -5118
VIEW Ver: 20.02.01A.1209.11
B - C 3931 -4266 F - G 5127 -5063
C - D 3717 - 3782 G - H 2204 - 2326
D -E 5178-5118 H - 1 39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - O 3832 - 3400 M - K 63 - 59
O - N 4611 - 4290 K - J 63 - 59
N - L 4614 - 4293 J - H 1979 -1759
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C-O
1432-1226
L-M
81 0
O - D
1197 - 926
L - J
1997 -1761
D - N
172 - 80
L - G
3268 - 3285
D - L
555 - 647
J - G
651 - 529
F - L
566 - 334
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvnnht n 2016 A-1 Rnnf Tn,ssns - Renrnd,iMinn of this dnn, nt in anv fnnn is nrnhihited without the wrift- nermL Sinn of A Rnnf Tn, ..,
jVu
CRMSBSB2 A13 HIPS 1 2
2560
208# 187,14
87# 187
187# # 187# 187#7# 18g# 189# 189# 189# 256#
d d d i i d i i d d i �_ 7'0-3/8" {
7' + 20'8"
=H0710 =H0510=4X10
C D E
T
M
T
ih ,•e-iie• 04;
d 3 1111.5X3 =6X10 III1.5X3
12
011.5X4 m5X10 =5X6
F G H
34'8"
7' �{
1�9/16 7'3-1/8" -i 11'3-7/8" + 16'1" 45-9/16"
�- 7'0-3/8" •-"12 3/ 2, I 2, I 2, f 2, 6 1 /! 2, 2, � 2, 2, 2'0-3/J
503# 10 109# 10 109# 10 9# 10 109# 10 109# 440
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 0.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.47 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x6 SP 2400f-2.OE; T1 2x4 SP M-30;
T4 2x4 SP #2;
Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:; B3,
B4 2x4 SP #2;
Webs: 2x4 SP #3; W5,W6 2x4 SP #2;
W7 2x4 SP M-30;
Bracing
(a) Continuous lateral restraint equally spaced on
member.
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 62 plf at -1.46 to 62 plf at 7.00
TC: From 31 plf at 7.00 to 31 plf at 27.67
TC: From 62 plf at 27.67 to 62 plf at 36.13
BC: From 14 plf at 0.00 to 14 plf at 7.26
BC: From 7 plf at 7.26 to 7 plf at 27.64
BC: From 14 plf at 27.64 to 14 plf at 34.67
TC: 208 lb Conc. Load at 7.03
TC: 187 lb Conc. Load at 9.06,11.06,13.06,15.06
17.06,17.60
TC: 189 lb Conc. Load at 19.60,21.60,23.60,25.60
TC: 256 lb Conc. Load at 27.64
BC: 503 lb Conc. Load at 7.03
BC: 109 lb Conc. Load at 9.06,11.06,13.06,15.06
17.06,17.60,19.60,21.60,23.60,25.60
BC: 440 lb Conc. Load at 27.64
T
7
1
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -1.066 F 386 360
Loc R+ / R- / Rh / Rw / U / RL
B 3210 I- /- /- /2449 /-
Rep Factors Used: No
VERT(CL): 1.501 F 274 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.466 K - -
1 3200 /- !- /- /2451 /-
Plate Type(s):
HORZ(TL): 0.658 K
Wind reactions based on MWFRS
WAVE, HS
Creep Factor: 2.0
B Brg Width = 3.5 Min Req = 1.5
Max TC CSI: 0.849
1 Brg Width = 3.5 Min Req = 1.9
Max BC CSI: 0.997
Bearings B & I are a rigid surface.
Max Web CSI: 0.953
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 371.0 Ibs
A - B 20 -18 F - G 7387 - 9478
VIEW Ver: 20.02.01A.1209.11
B - C 4526 -5884 G - H 3006 -3887
C D 4254 5556 H I 2430 3152
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
TC 24 7.00 27.67
BC 60 0.15 7.26
BC 46 7.26 18.73
BC 68 18.73 34.52
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
D - E 4254 - 5556 1 - J 20 -18
E -F 7489 - 9617
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - P 5419 - 4146 N - L 125 - 98
P - O 8136 - 6302 L - K 2765 - 2130
O - M 8144 - 6306 K - 1 2775 - 2133
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - P
2366 -1730
M - G
5837 - 4569
P - E
2142 - 2698
M - L
4220 - 3268
E - O
212 - 63
G - L
1986 - 2398
E - M
1532 -1228
L - H
1415 -1104
F - M
317 - 220
H - K
242 - 68
M-N
58 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvdnht 0 2016 A-1 Ronf Tnj. fiP - Ren di,rtinn of thin dor--t in anv f m, is nrnhihit.d without thn waft- nr:rmiccinn of A-1 Rnnf Tmcans
./oo I runs I Fuss I ype tally rly ua/ IU/zucl
CRMSBSB2 B01 GABL 2 1 2537
■■
M
l
4-3/16"
D=4X4
7'
n
QO
N
i . 1'5-9/16" i
1'5-9/1
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res,
PP Deflection in loc L/deft L/# Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): 0.001 H
999 360 Lot- R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.001 H
999 240 F* 101 /- /- /47 /75 /18
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.001 H
- - Wind reactions based on MWFRS
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.001 H
F Big Width = 84.0 Min Req = -
Des Ld: 37.00 Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Bearing B is a rigid surface.
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Max TC CSI: 0.369
Maximum Top Chord Forces Per Ply (Ibs)
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
Max BC CSI: 0.072
Chords Tens.Comp. Chords Tens. Comp.
C&C Dist a: 3.00 ft
Max Web CSI: 0.075
A - B 39 0 D - E 110 -29
Loc. from endwall: Any
Wgt: 32.2 Ibs
B - C 31 -32 E - F 31 -42
GCpi:0.18
C-D 113 -12 F-G 39 0
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
Lumber
Maximum Bot Chord Forces Per Ply (Ibs)
Top chord: 2x4 SP #2;
Chords Tens.Comp. Chords Tens. Comp.
Sot chord: 2x4 SP #2;
B - J 250 -52 1 - H 263 -55
Webs: 2x4 SP #3;
.1 - I 263 - 55 H - F 245 - 55
Plating Notes
All plates are 1.5X3 except as noted.
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp.
Purlins
C - J 289 -83 H - E 289 -83
In lieu of structural panels or rigid ceiling use purlins
D - 1 121 -106
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 6.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for gable wind bracing and other
requirements.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrmht ,1) 2016 A-1 in anv form is nmhlhitarl withniR the written nertniscinn ni A-1 Ronf Tmz
Jon
CRMSBSB2
I Iubb
B02
I l u55 I yhC �.tly I
GABL 1 1 ly
Uot Iu/LVG I
2538
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
�i
I— 3'6" 3'6"
1'5��
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 6.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for gable wind bracing and other
requirements.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
D=4X4
1'5��
T
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.001 H 999 360
Loc R+ / R- / Rh / Rw / U / RL
F* 101 /- !- /47 /75 /18
VERT(CL): 0.001 H 999 240
HORZ(LL): -0.001 J - -
Wind reactions based on MWFRS
HORZ(TL): 0.001 H
F Brg Width = 84.0 Min Req = -
Creep Factor: 2.0
Bearing B is a rigid surface.
Max TC CSI: 0.369
Bearing B requires a seat plate.
Max BC CSI: 0.072
Maximum Top Chord Forces Per Ply (Ibs)
Max Web CSI: 0.061
Chords Tens.Comp. Chords Tens. Comp.
A - B 39 0 D - E 110 -29
B-C 31 -32 E -F 54 -42
C - D 113 -12 F - G 39 0
Wgt: 32.2 Ibs
VIEW Ver: 20.02.01A.1209.11
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - J 250 - 52 1 - H 263 - 55
J - 1 263 - 55 H - F 245 - 55
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp.
C - J 289 - 83 H - E 289 _83
D -1 121 -106
`*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Vedfy design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPIA.
(:nnvrinht f1 2016 AA Rnnf Tnissas - Renrodurtinn of this dnrnmant in anv forn,. is nmhihit.d without tha —,ffan nannissinn of A-1 Rnnf Tnicsas
ion I russ I russ I ype t.tty my UJ/l U/2UY I
2539
CRMSBSB2 B03 COMN 2 1
- 3'6"
T 12
6
M
=2X4(A1) B
4.3/16
1 T •
A
SEAT PLATE REQ.
1'5�'�
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
EXP: C Kzt NA
Plate Type(s):
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 80 0.15 6.85
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Left bottom chord exposed to wind.
C= 3X4
7'
3'6"
D=2X4(A1)
SEAT PLATE REQ.
1'5i'�
n
DefI/CSI Criteria
♦ Maximum Keactlons (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.012 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.017 999 240
B 354 /- /- /371 /243 /125
HORZ(LL): -0.007 - -
D 354 /- /- /233 1229 /-
HORZ(TL): 0.008
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.5
Max TC CSI: 0.404
D Brg Width = 8.0 Min Req = 1.5
Max BC CSI: 0.371
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Max Web CSI: 0.000
Maximum Top Chord Forces Per Ply (Ins)
Wgt:26.6lbs
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.02.01A.1209.11
A - B 39 0 C - D 524 -266
B- C 546 _266 D- E 39 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - D 204 - 201
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C.—nnht n 2016 A-1 Rnnf Tniccec — RenrndnHinn of this d--ent in anv form is nrohihit.d without the wntten nenn,of A-i Ronf Tnicves
JOD
CRMSBSB2
t i uaa i i uaa i yNc
FG01 FLAT
..,ty rty w, iwcuc i
5 2
2481
118"
- 157-3/8"
=3X10 1111.5X3 =4X4
A B C
T
v
L
SEAT PLATE REQ.
3X4
D
III 1.5X3 = 7X6
E F
1113X4 =5X12 III1.5X4 III1.5X3 =7X10
15'9"
�-- 21-1 /4" 2' -�- 2' 2' - j-- 2' - - 2' - t_ 37-3/4"
536# 536# 536#
536# 536# 536#
Loading Criteria (psf) Wind Criteria
TCLL: 40.00 Wind Std: NA
TCDL: 10.00 Speed: NA mph
BCLL: 0.00 Enclosure: NA
BCDL: 5.00 Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00 Mean Height: NA ft
NCBCLL: 0.00 TCDL: NA psf
Load Duration: 1.00 BCDL: NA psf
Spacing: 24.0 " MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 :SP 2400f-2.OE + SP M-31:;
Webs: 2x4 SP #3; W1 2x6 SP #2; W2,W6 2x4 SP #2;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @ 6.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
----(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00)
TC: From 50 plf at 0.00 to 50 plf at 11.97
TC: From 100 plf at 11.97 to 100 plf at 15.61
BC: From 5 plf at 0.00 to 5 plf at 11.97
BC: From 10 plf at 11.97 to 10 plf at 15.61
BC: 536 lb Conc. Load at 1.97, 3.97, 5.97, 7.97
9.97.11.97
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Sid: 2014
Rep Factors Used: No
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.14 15.75
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
The TC of this truss shall be braced with attached spans
at 24" oc in lieu of structural sheathing.
Additional Notes
Truss must be installed as shown with top chord up.
Defl/CSI Criteria
PP Deflection in loc L/defi L/#
VERT(LL): 0.323 1 579 360
V E RT(C L ): 0.445 1 421 240
HORZ(LL): 0.047 A - -
HORZ(TL): 0.065 A
Creep Factor: 2.0
Max TC CSI: 0.677
Max BC CSI: 0.937
Max Web CSI: 0.947
Wgt: 148.4 Ibs
VIEW Ver: 20.02.01A.1209.11
G
III3X3
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
L 2234 /-/-
G 2042 /-/-
L Brg Width = 7.5 Min Req = 1.5
G Brg Width = 3.5 Min Req = 1.5
Bearings L & G are a rigid surface.
Bearing L requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 0- 2806 D- E 0- 3340
B- C 0- 2806 E- F 0- 3340
C-D 0-4415
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
L-K 80 0 1 - H 4371 0
K- J 4352 0 H- G 98 0
J - 1 4415 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-L
0 -1012
1 - D
318 0
A- K
2884 0
D- H
0 -1078
B-K
0 -9
E -H
0 -139
K- C
0 -1658
H- F
3356 0
C- J
454 0
F- G
0 - 985
• WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht n 201A A-1 Roof Tmsses — Renrndnntinn of this dnniment in — fnon is nrnhlhited withn,it thn written nenniscion of A-1 Roof To—,
Jon 1 russ I russ 1 ype arty t-ly
CRMSBSB2 FG02 FLAT 1 2
u6/I U/LUCI
2568
L
11,10-1 /8'°
A 4X12 =JX4 1111�X3 1111DX3 =VX6 -5X6F
_K H. G
SEAT PLATE REQ.
11'll 0-1 /8"
�-- 2'1-3/4" 2' 2' 2' 2' V3-1/2�'3 3/a"
836# 836# 836# 1
836# 836# 836#
Loading Criteria (Psq
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 0.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x6 SP 2400f-2.OE;
Webs: 2x4 SP #3; W1 2x6 SP #2; W2,W6 2x4 SP #2;
Nailnote
Nail Schedule:0.131"x3", min. nails
Top Chord: 1 Row @12.00" D.C.
Bot Chord: 2 Rows @ 6.00" D.C. (Each Row)
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
(1) 1/2" bolts may be used for
(2) 0.131"x3", min. nails on
The Bottom Chord Only.
Special Loads
------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00)
TC: From 50 plf at 0.00 to 50 plf at 11.59
BC: From 5 plf at 0.00 to 5 plf at 11.59
BC: 836 lb Conc. Load at 2.02, 4.02, 6.02, 8.02
10.02,11.31
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: No
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacir in oc) Start(ft) End(ft)
BC 120 0.12 11.72
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
The TC of this truss shall be braced with attached spans
at 24" oc in lieu of structural sheathing.
Additional Notes
Truss must be installed as shown with top chord up.
Deft/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.164 J 847 360
VERT(CL): 0.226 J 616 240
HORZ(LL): 0.027 A - -
HORZ(TL): 0.037 A
Creep Factor: 2.0
Max TC CSI: 0.680
Max BC CSI: 0.553
Max Web CSI: 0.857
Wgt: 131.6 Ibs
VIEW Ver: 20.02.01A.1209.11
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
L 2349 /- /- /- /- /-
G 3307
L Brg Width = 7.5 Min Req = 1.5
G Brg Width = 5.5 Min Req = 1.5
Bearings L & G are a rigid surface.
Bearing L requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 0- 2979 D- E 0- 3673
B -C 0-3704 E -F 0 -2118
C - D 0 - 3698
Maximum Bat Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
L- K 83 0 1- H 2388 0
K- J 3075 0 H- G 45 0
J - 1 3698 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
A-L
0 -978
D - 1
0 -161
A- K
3038 0
1- E
1569 0
K -B
0 -322
E -H
0 -911
B- J
668 0
H- F
2338 0
J -C
37 0
F-G
0 -1136
-WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise slated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(',mvnnht n 2016 A-1 — Re mdnrtlnn of thi., 6--ent in anv fort, is nrnhlhitnd mthn,t the wnften n"nni«inn of A-1 Rnnf Tni,cws
dOD ituaa iivaa iyPc W riy vJfiuf<u<i
CRMSBSB2 FL02 SY42 6 1 2577
3 5/8 1.5X3(R;
=1.5X3(R;
2'6"
(TYP)
6'11-7/8" _1
�---- 5'3" 14'11-7/8"
III1.5X3 =3X6 1111.5X3 1111.5X3 =3X4 1111.5X3 =3X6
A B C D E F G
IS
N NPIP ap'' I lEh".iM
P Ep, N i , " ���
=3X6
1'7-3/8'
SEAT PLATE REQ.
14'11-7/8"
Loading Criteria (psf) Wind Criteria
TCLL: 40.00 Wind Std: NA
TCDL: 10.00 Speed: NA mph
BCLL: 0.00 Enclosure: NA
BCDL: 5.00 Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00 Mean Height: NA ft
NCBCLL: 0.00 TCDL: NA psf
Load Duration: 1.00 BCDL: NA psf
Spacing: 24.0 " MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP M-30;
Bot chord: 4x2 SP M-30;
Webs: 4x2 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.25 14.80
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
See detail STRBRIBR1014 for bracing and bridging
recommendations.
Truss must be installed as shown with top chord up.
=1.5X3(R) 3-5/8"
=31, IL 1112X4(R)
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.249 D
702 360 Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): 0.345 D
506 240 M 814/-
FT/RT:10(0)/10(10)
HORZ(LL): 0.022 J
- - 1 808/-
Plate Type(s):
HORZ(TL): 0.030 J
M Brg Width = 7.5 Min Req = 1.5
WAVE
Creep Factor: 2.0
1 Brg Width = 3.5 Min Req = 1.5
Max TC CSI: 0.548
Bearings M & I are a rigid surface.
Max BC CSI: 0.580
Bearing M requires a seat plate.
Max Web CSI: 0.780
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 82.6 Ibs
A-B 1 0 D-E 0 -2316
VIEW Ver: 20.02.01A.1209.11
B- C 0 -2303 E- F 0 -1487
C- D 0- 2320 F- G 0 -1487
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
M- L 1403 0 K- J 2232 0
L-K 2320 0 1-1 0 -2
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens, Comp
N-O
0 -4
E -J
0
-823
A-M
0 -116
F -J
0
-274
M-B
0 -1559
J -G
1638
0
B -L
1013 0
G-H
0
-796
L-C
0 -338
1 - H
0
-11
D-K
0 -127
H - 1
0
-801
K - E
400 -137
•'WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(;nnvnnht n 2n1fi A-1 Rnnf Tnitte� — Remmdiitilon of thi[ dnniiment. in anv fnrm is nrnhihited without the written nerr i.—on of A-1 Ronf Tniase[
JOu IrUSS
CRMSBSB2 FL02GE
I russ I ype
SY42
uty I rly U,5/ I U/LUL l
6 1
2473
=1.5;
� =1
�— 1'4"
(TYP)
1 /4" - 13'3-1 /4" 14' 11-7
2'7 1/4"
=3X3
A B C D E F G H I J K L
X W V U T S R Q P O
=3X3
r 14'11-7/8"
Loading Criteria (psf)
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
13CLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 0.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP #2;
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
Bracing
Sheathing is required for any longitudinal(drag) forces.
All connections to be designed by the building designer.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels
or rigid ceiling use purlins
to laterally brace chords
as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 120
0.25 14.74
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up
.5X3(R) 3� 5/8
.5X3(R)
3-5/8"
Code / Misc Criteria
Deft/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Code:FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.000 L 999 360
Loc R+ / R- / Rh / Rw / U
/ RL
Rep Factors Used: Yes
VERT(CL): 0.001 L 999 240
N* 108/-
FT/RT:10(0)/10(10)
HORZ(LL): -0.000 B - -
N Brg Width = 179 Min Req = -
Plate Type(s):
HORZ(TL): 0.000 B
Bearing Y is a rigid surface.
WAVE
Creep Factor: 2.0
Maximum Top Chord Forces Per Ply (Ibs)
Max TC CSI: 0.117
Chords Tens.Comp. Chords Tens.
Comp.
Max BC CSI: 0.012
A- B 1 0 G- H 1
0
Max Web CSI: 0.036
B- C 7 0 H- I 1
0
Wgt: 84.0 Ibs
C- D 1 0 1- J 1
0
D-E 1 0 J -K 1
0
VIEW Ver: 20.02.01A.1209.11
E- F 1 0 K- L 1
0
F-G 1 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Cori Chords Tens.
Comp.
Y-X 0 -1 S -R 0
-1
X-W 6 0 R-Q 0
-1
W-V 0 -1 Q-P 0
-1
V-U 0 -1 P-O 0
-1
U-T 0 -1 O-N 0
-1
T-S 0 -1
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
Z-AA 0 -3 L-N 0
-66
A-Y 0 -52 M-AB 0
-3
X-C 0 -18
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens.
Comp.
B-X 0 -129 G-S 0
-133
C-W 0 -121 H-R 0
-133
D-V 0 -138 1 - Q 0
-135
E-U 0 -132 J -P 0
-128
F-T 0 -134 K-O 0
-156
"WARNING' Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (Too) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineer
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and Ti The approval of the TDD and any field
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. Ti defines the responsibilities and duties of the Truss
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in Ti
(:nnvnnht n 2016 A-1 R—f T,—, — Renrnd-1— of thin dnrarment in anv fnnn I.., nmhlhited with—t the written nPrmiasinn of A-1 Ronf Tnissec
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JOD
CRMSBSB2
11— yN�
FL03 SY42
..try 1.y
1 1
2474
3-5 =1.5X3(R)
=1.5X3(R)
3-5/8"
2'6"
(TYP)
7'10-1/2"
III1.5X3 =3X10 III1.5X3
A B C
10,
3X4
=3X4 1111.5X3
D E F
0
SEAT PLATE REQ.
18'11"
Loading Criteria (psf)
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 0.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP M-30;
Bot chord: 4x2 SP M-30;
Webs: 4x2 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.25 18.73
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Deflection
Max JT VERT DEFL: LL: 0.39" DL: 0.20". See detail
DEFLCAMB1014 for camber recommendations.
Additional Notes
+ 2x6 continuous strongback. See detail
STRBRIBR1014 for bracing and bridging
recommendations.
Truss must be installed as shown with top chord up.
— 18,111,
1111.5X3 =3X10 1111.5X3
G H I
' 3-5/8"
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.393 E 564 360
Loc R+ / R- / Rh / Rw / U / RL
P 1030/-
Rep Factors Used: Yes
VERT(CL): 0.502 E 441 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.049 K - -
K 1024/-
Plate Type(s):
HORZ(TL): 0.068 K
P Brg Width = 7.5 Min Req = 1.5
WAVE
Creep Factor: 2.0
K Brg Width = 3.5 Min Req = 1.5
Max TC CSI: 0.483
Bearings P & K are a rigid surface.
Max BC CSI: 0.748
Bearing P requires a seat plate.
Max Web CSI: 0.675
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 103.6 Ibs
A-B 1 0 E -F 0 -3826
VIEW Ver: 20.02.01A.1209.11
B-C 0-3125 F-G 0 -3161
C-D 0 -3125 G-H 0 -3161
D- E 0- 3830 H- 1 2 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
P- O 1843 0 M- L 3777 0
O- N 3828 0 L- K 1884 0
N - M 3830 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
Q- R
0 - 4
M- F
474
- 248
A-P
0 -111
F -L
0
-681
P- B
0- 2048
G- L
0
- 254
B -O
1417 0
L-H
1412
0
C - O
22 - 287
H - K
0
- 2083
O-D
0 -988
1 - J
0
-105
D-N
128 -60
K-J
0
-11
E-M
118 -288
J -K
0
-114
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r,nvnnht cn 2016 A-1 Rnnf Tmssas — Renrnd—Ainn of this dnnimanf in anv form is nrnh,hit,.d withnut the wntlen nem,ission of AA Rnnf Tnic
goo r runs I runs I ype �ry riy U6/Ill/LUCI
2475
CRMSBSB2 FL03GE SY42 1 1
�-1'4" 1'4" -{
(TYP) (TYP)
41/ 9'3-1/4"-- 96r 17'6-1/4" 1811
2'7 1 /4" 0'10-1 /4'
=3X3 =3X3
A B C D E F G H I J K L M N O P
=MH
1.5X3 ) 4AJ
1.5X3(R)
1.5X3(R) 1.5X3(R)
A 3-5l8"
AG AF A AD AC AB AA ZY X W V U S
3X3 =3X3
SEAT PLATE REQ.
18'11"
Loading Criteria (psf) Wind Criteria Code / Misc Criteria
Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or *=PLF
TCLL: 40.00 Wind Std: NA Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity
Non -Gravity
TCDL: 10.00 Speed: NA mph TPI Std: 2014
VERT(LL): 0.000 P 999 360 Loc R+ / R- / Rh
/ Rw / U / RL
BCLL: 0.00 Enclosure: NA Rep Factors Used: Yes
VERT(CL): 0.000 P 999 240 R* 109/-
BCDL: 5.00 Category: NA FT/RT:10(0)/10(10)
HORZ(LL): 0.000 P - - R Brg Width = 226
Min Req = -
EXP: NA Kzt: NA Plate Type(s):
HORZ(TL): 0.000 P Bearing AG is a rigid surface.
Des Ld: 55.00 Mean Height: NA ft WAVE
Creep Factor: 2.0 Bearing AG requires a seat plate.
NCBCLL: 0.00 TCDL: NA psf
Load Duration: 1.00 BCDL: NA psf
Max TC CSI: 0.082 Maximum Top Chord Forces Per Ply (Ibs)
Spacing: 24.0 " MWFRS Parallel Dist: NA
Max BC CSI: 0.008 Chords Tens.Comp.
Chords Tens. Comp.
C&C Dist a: NA ft
Max Web CSI: 0.032 A- B 1 0
1- J 8 0
Loc. from endwall: NA
Wgt: 109.2 Ibs B- C 7 0
J- K 1 0
I: NA GCpi: NA
C- D 3 0
K- L 1 0
Wind Duration: NA
VIEW Ver: 20.02.01A.1209.11 D- E 3 0
L- M 1 0
Lumber
E- F 3 0
M- N 1 0
F- G 3 0
N- O 1 0
Top chord: 4x2 SP #2;
G- H 3 0
O- P 1 0
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
H - 1 3 0
Bracing
Maximum Bot Chord Forces
Per Ply (Ibs)
Sheathing is required for any longitudinal (drag) forces.
Chords Tens.Comp.
Chords Tens. Comp.
All connections to be designed by the building designer.
AG-AF 0 -1
Y - X 1 0
Plating Notes
AF-AE 4 0
X- W 0 1
AE-AD 0 -3
W - V 0 1
All plates are 1.5X3 except as noted.
AD -AC 0 -3
V- U 0 1
Purlins
AC -AB 0 -3
U- T 0 1
AB -AA 0 -3
T - S 0 -1
In lieu of structural panels or rigid ceiling use purlins
Z 0
AA 3
S- R 0 1
to laterally brace chords as follows:
Z - Y 0 -3
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.25 18.67
Apply purlins to any chords above or below fillers
Maximum Web Forces
Per Ply (Ibs)
at 24" OC unless shown otherwise above.
Webs Tens.Comp.
Webs Tens. Comp.
Additional Notes
AH-AI 0 -3
1- X 0 -12
Truss must be installed as shown with top chord up.
A -AG 0 -52
P - R 0 -51
AF- C 0 -15
Q -AJ 0 -3
Maximum Gable Forces
Per Ply (Ibs)
Gables Tens.Comp.
Gables Tens. Comp.
B -AF 0 -129
Y- 1 0 - 65
C-AE 0 -123
X-J 0 -134
ID -AD 0 -138
K-W 0 -133
E-AC 0 -132
L-V 0 -133
F-AB 0 -133
M-U 0 -133
G-AA 0 -138
N-T 0 -134
H-Z 0 -82
O-S 0 -134
"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet
before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal
on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading
conditions, suitability and use of this Truss for any Building is the
Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field
# 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and
Contractor. All notes set out in the TDD and the practices and
4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance.
TPI-1 defines the responsibilities and duties of the Truss
Fod Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Convrinht n?n16 A.1 Rnnf Tnivae<— RenrnAm�tinn nt this rinrmmant in env form ix nrmhihitetl withrnir the wntten nerrnitcimn of A-1 Rmnf Tm—,
JOB t ivaaFL0SY42 1 i iuoa i yPc ..try r 1 iy vur ivr�u� i
CRMSBSB2 5 2574
3-5/8"
3-5/8"
1.5X3(R)
1.5X3(R) p
N
2'6" ---�
(TYP)
671 /2" 8'8-1 /2" 15'9"
III1.5X3 =4X6 1111.5X3 =3X3 =3X3 III1.5X3 =4X6 1112X4
A B C D E F G H
O
M L K J I
=3X6 =3X8 1111.5X3 III1.5X3 =3X8 =3X6
SEAT PLATE REQ.
15'9"
Loading Criteria (psf) Wind Criteria
TCLL: 40.00 Wind Std: NA
TCDL: 10.00 Speed: NA mph
BCLL: 0.00 Enclosure: NA
BCDL: 5.00 Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00 Mean Height: NA ft
NCBCLL: 0.00 TCDL: NA psf
Load Duration: 1.00 BCDL: NA psf
Spacing: 24.0 " MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP #2;
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.25 15.50
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
See detail STRBRIBR1014 for bracing and bridging
recommendations.
Truss must be installed as shown with top chord up.
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.227 K
805 360 Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): 0.295 E
619 240 N 852 /- /- /-/-
FT/RT:10(0)/10(10)
HORZ(LL): 0.034 1
- - 1 866/-
Plate Type(s):
HORZ(TL): 0.046 1
N Brg Width = 7.5 Min Req = 1.5
WAVE
Creep Factor: 2.0
1 Brg Width = 3.5 Min Req = 1.5
Max TC CSI: 0.718
Bearings N & I are a rigid surface.
Max BC CSI: 0.923
Bearing N requires a seat plate.
Max Web CSI: 0.471
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Wgt: 88.2 Ibs
A-B 1 0 E-F 0 -2376
VIEW Ver: 20.02.01A.1209.11
B- C 0 -2371 F- G 0 -2376
C-D 0 -2371 G-H 3 0
D - E 0 - 2604
Maximum Bot Chord Forces Per Ply (lbs)
Chords Tens.Comp. Chords Tens. Comp.
N- M 1482 0 K- J 2605 0
M- L 2603 0 J- 1 1480 0
L - K 2604 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
O-P
0 -4
K-E
97
-106
A-N
0 -108
E-J
32
-531
N- B
0 -1647
F- J
26
- 243
B- M
983 0
J- G
990
0
C- M
55 - 227
G- 1
0
-1647
M-D
28 -559
1 - H
0
-15
D-L
124 -100
H - 1
0
-113
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Toss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C:nnvrinht n 2016 A-1 Roof Th., - RPnmdnntinn of thin, dnrnment in anv form Ic nrnhihitt'd without the wnttan nP--on of A-1 Roof Tni«r+.v
uoo 1 russ truss 1 ype Uty fry Ub/ 1 U/LUL I
CRMSBSB2 FL06 SY42 1 1 2477
1.5X3(R)
=1.5X3(R)K
Loading Criteria (psf)
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 0.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP 42;
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 117 0.25 10.00
Apply puffins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Hangers / Ties
(J) Hanger Support Required, by others
Additional Notes
Truss must be installed as shown with top chord up.
2'6"
(T'P)
i 2-9„ 1 4,9„ 10'
III1.AX3 =:C4 1111CX3 _ff4 IIII.PX3
1111.5X3 =&3 _3X4
_�X4
SEAT PLATE REQ.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
1' 10-1 /2"
10,
Defl/CSI Criteria
PP Deflection in loc L/defl 1_4
VERT(LL): 0.176 C 663 3E
VERT(CL): 0.268 C 436 2
HORZ(LL): -0.028 D -
HORZ(TL): 0.042 D -
Creep Factor: 2.0
Max TC CSI: 0.885
Max BC CSI: 0.736
Max Web CSI: 0.306
Wgt: 53.2 Ibs
VIEW Ver: 20.02.01A.1209.11
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
40 1 550
- F 536 /- /- /- /- A
I Brg Width = 7.5 Min Req = 1.5
F Brg Width = - Min Req = -
Bearing I is a rigid surface.
Bearing I requires a seat plate.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens, Comp.
A-B 1 0 C-D 0 -996
B -C 0 -1000 D-E 0 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
I -H 994 0 G-F 881 0
H - G 1000 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
J -K 0 -4 C-G 0 -81
A- 1 24 -105 G- D 277 0
1 - B 0-1105 D-F 0 -970
B -H 135 0 E -F 0 -98
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
(:nnvnnht n 2n1e A-1 Roof Tniases - Ranrndnntinn of this d-iiment in anv fnrn is nrohlhitad with—t th, woftP ns--ion of A-1 Roof Tnicsns
Job
CRMSBSB2
I I ubb I t ubb 1 yPG
FL06E SY42
=1.5X3(R)
1.5X3(R)F
I
Loading Criteria (psf)
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA KA: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 0.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA It
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP #2;
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
Bracing
Sheathing is required for any longitudinal (drag) forces.
All connections to be designed
by the building designer.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels
or rigid ceiling use purlins
to laterally brace chords
as follows:
Chord Spacing(in
oc) Start(ft) End(ft)
BC 114
0.25 9.75
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up
f11-1/44-- 2'11-1/4"
W iLy f-ly VJ/ IVIG U41
1 1 2478
2'
(TYP)
8'11-1/4" 10'
A B CX3 D E F III�X4
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defi
L/# Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.000 E 999
360 Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): 0.000 E 999
240 H* 109
FT/RT:10(0)/10(10)
HORZ(LL): -0.000 B -
- H Brg Width = 120 Min Req = -
Plate Type(s):
HORZ(TL): 0.000 B
Bearing N is a rigid surface.
WAVE
Creep Factor: 2.0
Bearing N requires a seat plate.
Max TC CSI: 0.184
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.020
Chords Tens.Comp. Chords Tens. Comp.
Max Web CSI: 0.047
A- B 1 0 D- E 3 0
Wgt: 56.0 Ibs
B- C 9 0 E- F 3 0
C-D 3 O F-G 3 0
VIEW Ver: 20.02.01A.1209.11
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
N-M 0 -1 K-J 0 -3
M-L 7 0 1-1 0 -3
L-K 0 -3 1 - H 0 -3
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
O-P 0 -2 H-G 0 -15
A-N 0 -19 G-H 0 -17
M-C 0 -19
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Camp
B-M 0 -157 E -J 0 -206
C-L 0 -198 F - 1 0 -165
D-K 0 -201
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-I.
(;nnvdnht 0-) 2016 A-1 Rnnf Tn,s n., — Rnnrndurtinn of this dnrn 1 in anv fnnn I�, nrnhihited without th, wdhen nen m—n of A-1 Rnnf Tni—
juu Russ Muss type pity rly UO/IU/LULI
CRMSBSB2 FL07 SY42 1 1 2571
2'6" —�
(TYP)
6'7-1/2"
III1.5X3 =4X6
A B
=1.5X3(R)
1.5X3(R) F
r
3X6
8'8-1/2"
1111.5X3 =3X3
C D
1 5'5-1/2" -{
=3X3 1111.5X3 =3X8 III1.5X3
E F IS H
=3X6 IIII.bX3 IIII.bX3 =3X6 =3X6
1'11-1 /2"
SEAT PLATE REQ.
1 5'5-1/2"
Loading Criteria (psf) Wind Criteria
TCLL: 40.00 Wind Std: NA
TCDL: 10.00 Speed: NA mph
BCLL: 0.00 Enclosure: NA
BCDL: 5.00 Category: NA
EXP: NA KA: NA
Des Ld: 55.00 Mean Height: NA ft
NCBCLL: 0.00 TCDL: NA psf
Load Duration: 1.00 BCDL: NA psf
Spacing: 24.0 " MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP #2;
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 120 0.25 15.46
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Hangers / Ties
(J) Hanger Support Required, by others
Additional Notes
See detail STRBRIBR1014 for bracing and bridging
recommendations.
Truss must be installed as shown with top chord up.
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/# Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.226 K
806 360 Loc R+ / R- / Rh / Rw / U / RL
Rep Factors Used: Yes
VERT(CL): 0.293 E
623 240 N 850
FT/RT:10(0)/10(10)
HORZ(LL): 0.034 1
- - 1 836
Plate Type(s):
HORZ(TL): 0.046 1
N Brg Width = 7.5 Min Req = 1.5
WAVE
Creep Factor: 2.0
1 Brg Width = - Min Req = -
Max TC CSI: 0.704
Bearing N is a rigid surface.
Max BC CSI: 0.908
Bearing N requires a seat plate.
Max Web CSI: 0.469
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Camp.
Wgt: 85.4 Ibs
A-B 1 0 E -F 0 -2394
VIEW Ver: 20.02.01A.1209.11
B- C 0 -2362 F- G 0 -2394
C-D 0-2362 G-H 0 0
D - E 0 -2591
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
N- M 1478 0 K- J 2591 0
M- L 2590 0 J- 1 1537 0
L - K 2591 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
O-P 0 -4 K -E 99 -112
A-N 0 -108 E -J 57 -510
N- B 0 -1642 F- J 36 - 235
B -M 978 0 J -G 948 0
C- M 53 - 226 G- 1 0 -1692
M-D 29 -551 H - 1 0 -106
D -L 121 -100
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C.—rinht C) 2016 AA Rnnf Tr„.-— — Renrnd"rtinn of thi- Ano-ent in anv fnnn is nrnhihited withrnR film wnften nannis.i.n of A-1 Rnnf Tn,«ws
JOb i ruaa i tuaa i yNG ly riy tr�1 ivfctrc t
CRMSBSB2 FL07GE SY42 g 1 2480
�--2'---�
(TYP)
1'8" —+— 3'8" 13'8"
A
3-5/8" =1.5X3(R)S
1.5X3(R)T
R
Loading Criteria (psf)
Wind Criteria
TCLL: 40.00
Wind Std: NA
TCDL: 10.00
Speed: NA mph
BCLL: 0.00
Enclosure: NA
BCDL: 5.00
Category: NA
EXP: NA Kzt: NA
Des Ld: 55.00
Mean Height: NA ft
NCBCLL: 0.00
TCDL: NA psf
Load Duration: 1.00
BCDL: NA psf
Spacing: 24.0 "
MWFRS Parallel Dist: NA
C&C Dist a: NA ft
Loc. from endwall: NA
I: NA GCpi: NA
Wind Duration: NA
Lumber
Top chord: 4x2 SP #2;
Bot chord: 4x2 SP #2;
Webs: 4x2 SP #3;
Bracing
Sheathing is required for any longitudinal(drag) forces.
All connections to be designed
by the building designer.
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels
or rigid ceiling use purlins
to laterally brace chords
as follows:
Chord Spacing(in
cc) Start(ft) End(ft)
BC 120
0.25 15.21
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Additional Notes
Truss must be installed as shown with top chord up
15'5-1 /2"
=3X3 1112X4
B C D E F G H I
R)
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.000 1 999 360
Loc R+ / R- / Rh / Rw / U / RL
J* 109
Rep Factors Used: Yes
VERT(CL): 0.001 1 999 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.000 B - -
J Brg Width = 185 Min Req = -
Plate Type(s):
HORZ(TL): 0.000 B
Bearing R is a rigid surface.
WAVE
Creep Factor: 2.0
Bearing R requires a seat plate.
Max TC CSI: 0.180
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.018
Chords Tens.Comp. Chords Tens. Comp.
A- B 1 0 E- F 3 0
Max Web CSI: 0.047
Wgt: 78.4 Ibs
B- C 10 0 F- G 3 0
C-D 3 0 G-H 3 0
VIEW Ver: 20.02.01 A.1209.11
D- E 3 0 H- 1 3 0
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
R-Q 0 -1 N-M 0 -3
Q-P 7 0 M -L 0 -3
P-O 0 -3 L-K 0 -3
O-N 0 -3 K-J 0 -3
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
S-T 0 -3 1-1 0 -15
A-R 0 -64 1-1
0 -66
Q-C 0 -21
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp
B -Q 0 -187 F-M 0 -200
C-P 0 -192 G-L 0 -202
D-O 0 -204 H-K 0 -192
E -N 0 -199
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPIA. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht (�) 2n1fi A.1 in anv form itt nmhihited withn"t th" wnttrn n"rmiccinn of A-1 Rnnf Tni—,
.roo I runs I fuss I ype u[y fly US/'I U/LOCI
CRMSBSB2 HJ7 HIP 2 1 2556
T
A-311 fi'
� 1'11-13/16"
-25# 255#
129#
t i �_ 2'8-11 /16" --�
9' 10-1 /16" 1
1'5-1/�- �- i 2'9-15/16"
10#
86 2'9-15/16"
as#
155#
Loading Criteria (psf) Wind Criteria
Code / Misc Criteria
Deft/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res. PP Deflection in loc L/defi L/#
Gravity Non -Gravity
TCDL: 10.00 Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.023 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed
Rep Factors Used: Varies by Ld C %OERT(CL): 0.053 F 999 240
B 321 /- /- /- /401 /-
BCDL: 7.00 Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): 0.009 F - -
E 331 I- /- /- /232 /-
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.022 F
D 68 /- /- /- /86 /-
Des Ld: 37.00 Mean Height: 25.00 It
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
NCBCLL: 10.00 TCDL: 5.0 sf
p
Max TC CSI: 0520
B Brg Width = 4.2 Min Req = 1.5
Load Duration: 1.25 BCDL: 4.2 psf
"
.
Max BC CSI: 0.981
E Brg Width = 1.5 Min Req = -
Spacing: 24.0 MWFRS Parallel Dist: 0 to h/2
D Brg Width = 1.5 Min Req = -
C&C Dist a: 3.00 ft
Max Web CSI: 0.264
Bearing B is a rigid surface.
Loc. from endwall: not in 4.50
Wgt: 40.6 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
GCpi:0.18
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60
VIEW Ver: 20.02.01A.1209.11
Lumber
A-B 19 -20 C-D 78 -66
B - C 624 -494
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
Special Loads
B- F 487 -555 F- E 0 0
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From -0 plf at -1.98 to 61 plf at -0.10
TC: From 2 plf at -0.10 to 2 plf at 9.84
Maximum Web Forces Per Ply (Ibs)
BC: From 2 plf at 0.00 to 2 pif at 9.84
Webs Tens.Comp.
TC: -25 lb Conc. Load at 1.46
TC: 129 lb Conc. Load at 4.29
C - F 603 -529
TC: 255 lb Conc. Load at 7.12
BC: 10 lb Conc. Load at 1.46
BC: 86 lb Conc. Load at 4.29
BC: 155 lb Conc. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use puriins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 115 0.15 9.84
Apply puffins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvdnht Z 2016 A-1 Ronf Tma .., - Renrnduntinn of thi., do .-ent in env form I.., nrnhihited without the written n,rmi%.,,n of A-1 Rnnf Tnicves.
JOD uaa i yNc fry r ry vur i �tav� �
CRMSBSB2 HJ7A HIP 1 1 2557
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NC13CLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
T
a31i6'
1
f 1-11-13/16"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP M-30;
Webs: 2x4 SP #3;
Special Loads
-----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From -0 plf at -1.98 to
61 plf at -0.10
TC: From 2 plf at -0.10 to
2 plf at 9.84
BC: From 2 plf at 0.00 to
2 plf at 9.84
TC: 9 lb Conc. Load at 1.46
TC: 144 lb Conc. Load at 4.29
TC: 263 lb Conc. Load at 7.12
BC: 19 lb Conc. Load at 1.46
BC: 90 lb Conc. Load at 4.29
BC: 157 lb Conc. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 113 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
9# 144# 263#
+ + �_ 78-11/16"
0
9' 10-1 /16"
1'5-1/�---- /2" 2'9-15/16"- 1 2-9-15/16"
90#
19# 157#
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defi L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.025 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
B 359 /- /- /- /369 /-
Rep Factors Used: Varies by Ld C
%q-RT(CL): 0.053 F 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.010 F - -
E 353 /- /- /- /241 /-
Plate Type(s):
HORZ(TL): 0.022 F
D 67 /- /- /- /90 /-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.571
B Brg Width = 4.2 Min Req = 1.5
Max BC CSI: 0.975
E Brg Width = 1.5 Min Req = -
Max Web CSI: 0.288
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 40.6 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.02.01A.1209.11
A - B 19 - 20 C - D 80 - 68
B - C 628 - 548
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B- F 530 - 568 F- E 0 0
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - F 616 - 576
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Convdoht nc 2016 A-1 Rnnf Tni .,, - Ranrod,rotm of thi., doom .t in anv form is nroh,biloil with-t the written nenniacion of A-1 Rnnf Tni«r+,
auu 11 u�a I t u�a I yNe �ry rry VJ/ I V/LUL I
2558
CRMSBSB2 HJ7B HIP 1 1
17#
126#
? d
12
4.24 p
III1.5X3 C
d,
2X4(A1)B H =3X4
4-3 tl 6'
A I o 2.12
12
1'11-13/16"
9'10-1/16" �-
Loading Criteria (pet)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: C KZt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 fit
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From -0 plf at -1.98 to
61 plf at -0.10
TC: From 2 plf at -0.10 to
2 plf at 9.84
BC: From 2 plf at 0.00 to
2 plf at 9.84
TC: -17 lb Conc. Load at 1.46
TC: 126 lb Conc. Load at 4.29
TC: 251 lb Conc. Load at 7.12
BC: 2 lb Conc. Load at 1.46
BC: 84 lb Conc. Load at 4.29
BC: 155 lb Conc. Load at 7.12
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 70 0.15 9.84
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Additional Notes
Shim all supports to solid bearing.
251#
2'8-11/16"
E
T
:3X6 D v
c?
fV
GF -c5X6
�o 'v
m
1
1'5-1/�- " 2'9-15/16" �� 2'9-15/16"
84#
2# 155#
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defi L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.062 C 999 360
Loc R+ / R- / Rh / Rw / U / RL
1 322 /- /- /- /401 /-
Rep Factors Used: Varies by Ld C
§q-:RT(CL): 0.081 C 999 240
FT/RT:10(0)/10(10)
HORZ(LL): -0.017 H - -
F 394 /- /- /- /319 /-
Plate Type(s):
HORZ(TL): 0.022 H
E 22 /-1 /- /1 /- 1-
WAVE
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.291
1 Brg Width = 4.2 Min Req = 1.5
Max BC CSI: 0.991
F Brg Width = 1.5 Min Req = -
Max Web CSI: 0.516
E Brg Width = 1.5 Min Req = -
Bearing I is a rigid surface.
Wgt: 47.6 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.02.01A.1 209.1 1
A-B 19 -20 C-D 1008 -1118
B-C 1031 -1116 D-E 7 -12
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 1065 - 956 G - F 69 - 56
H - G 688 - 629
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - H 138 - 40 D - G 650 - 684
H - D 454 - 346
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SECA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized lemis are as defined in TPI-1.
Cnnvnnht (.) 2016 A-1 Rnnf - Rnnrndnntinn of thir; don--t in anv form is nrnhihit.d withnut thn wnftnn nnrmiccinn of A-1 Rnnf Tm."sns
Job rivao iivaa iyNc .fry I riy v.n nncuci
CRMSBSB2 J1 JACK 7 1 2540
4-333"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 10.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 7.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 25.00 ft
NCBCLL: 10.00
TCDL: 5.0 psf
Load Duration: 1.25
BCDL: 4.2 psf
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
12 C
6
2X4(A1) B T
10-3/16" CO
L0 r
A D
i - 1' ---I
1'5-9/16" --�
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): NA
Loc R+ / R- / Rh / Rw / U / RL
B 218 /_ /_ /243 /181 180
VERT(CL): NA
HORZ(LL): 0.000 D
D 5 /-14 /- /28 /24 /-
HORZ(TL): 0.001 D
C - /-40 /- /66 /68 /-
Creep Factor: 2.0
Wind reactions based on MWFRS
Max TC CSI: 0.410
B Brg Width = 3.5 Min Req = 1.5
Max BC CSI: 0.058
D Brg Width = 1.5 Min Req = -
Max Web CSI: 0.000
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Wgt: 5.6 Ibs
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.02.01A.1209.11
A-B 39 0 B -C 91 -34
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
**WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted an the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:onvnoht n 2n16 A-1 Roof Tmc .., — Renrod,intinn of thi., docmm,nt. o anv form. i< nrnhlbitud without thr. wdnp.n ne. ni%cion of A-1 Roof Tnicves
Joo truss I runs I ype Qry My UJ/ I U/LUG I
CRMSBSB2 J 1 A JACK 1 1 2541
4-3331
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
12
6
2X4
1.9
A1)
A
10-3/16"
1
C
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria I♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/# Gravity Non -Gravity
VERT(LL)- NA I Loc R+ / R- I Rh / Rw / U / RL
VERT(CL): NA
HORZ(LL): -0.000 C
HORZ(TL): 0.000 C
Creep Factor: 2.0
Max TC CSI: 0.022
Max BC CSI: 0.016
Max Web CSI: 0.000
Wgt: 4.2 Ibs
VIEW Ver: 20.02.01A.1209.11
A 45 /- /-
/28 /15 /35
C 14 /- I-
/9 /5 /-
B 22 /- /-
116 /29 /-
Wind reactions based on MWFRS
A Brg Width = 3.5
Min Req = 1.5
C Brg Width = 1.5
Min Req = -
B Brg Width = 1.5
Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A - B 10 - 40
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
,*WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1,
Convnoht n 9Me A-1 Roof Toisses - Rnnrndnrfinn of thi, do,.--t in wnv form I.c nrnhihited with-t the written nennl«inn of A-1 Roof Tnicce[
Job
CRMSBSB2
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
IIUJB.
J 1
IIJACK U,J IyNG ..ely
1
rly VJ/IU/c
1
VGI
12
C
T
1
6
2X4(A1) B
T
T
10-3
CO
4-3/�16"
D
2-1 ia"
j
r
A
a 3
12
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 10 0.15 1.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Shim all supports to solid bearing.
1-5-9/16" --�
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.000 D 999 36
VERT(CL): 0.000 D 999 24
HORZ(LL): 0.000 D - -
HORZ(TL): 0.000 D
Creep Factor: 2.0
Max TC CSI: 0.410
Max BC CSI: 0.050
Max Web CSI: 0.000
Wgt: 7.0 Ibs
VIEW Ver: 20.02.01A.1209.11
♦ Maximum Reactions (Ibs)
Gravity
Loc R+ / R- / Rh
2542
Non -Gravity
/Rw /U /RL
B 218 /- /-
/238 /182 /80
D 1 /-23 /-
142 /39 /-
C - /-31 /-
/51 /52 /-
Wind reactions based on MWFRS
B Brg Width = 3.5
Min Req = 1.5
D Brg Width = 1.5
Min Req = -
C Brg Width = 1.5
Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 39 0 B-C 70 -25
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 31 -10
.*WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C.nnvdnht n 201R A-1 Roof — Renrndnotinn of thin dnr e.nt in anv form ix nrohihit,d without the wdhen nennL nn of A-1 Roof Tnl.,ces
doo 1 runs t fuss 1 ype Qly fry U3/ I U/GUCI
CRMSBSB2 J3 JACK 2 1 2543
4-3"
1'5-9/16"
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
rO
3'
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D
HORZ(TL): 0.002 D
Creep Factor: 2.0
Max TC CSI: 0.417
Max BC CSI: 0.057
Max Web CSI: 0.000
Wgt: 11.2 Ibs
VIEW Ver: 20.02.01A.1209.11
T
MI
Ln
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 233 /- /- /213 /154 /155
D 43 /- /- /22 /1 /-
C 64 /- /- /37 /85 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens, Comp.
A-B 39 0 B-C 29 -104
Maximum Bot Chord Forces Per Ply (Ibs)
Chords TenS.Coni
B -D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent orthe Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvdnht n 2n16 AA Rnnf Tmsses - Rnnmd,, t,nn of this dor.--t in anv forn,. is nmhihit.d without this wdhr+n—nnissinn M A-1 Rnnf T.,—,
Job
CRMSBSB2
I rubs
J3A
[rust I ype v.Ity rry
JACK 1 1
VJ/ I V/GVL I
2544
Loading Criteria (psi
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
2X4(A
4-331
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 34 0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
12 B
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defi L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.002 C
HORZ(TL): 0.002 C
Creep Factor: 2.0
Max TC CSI: 0.311
Max BC CSI: 0.183
Max Web CSI: 0.000
Wgt: 9.8 Ibs
VIEW Ver: 20.02.01A.1209.11
1
1
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 120 /- /-
/76 /51 /109
C 47 /- /-
/26 /6 /-
B 79 /- /-
/57 /101 /-
Wind reactions based on MWFRS
A Brg Width = 3.5
Min Req = 1.5
C Brg Width = 1.5
Min Req = -
B Brg Width = 1.5
Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 36 -144
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kdstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:ownnht n 201R A-1 Roof Tonto, - Renrnd-Mon of this doonment in anv form is nmhihitsd withnnt the wntten ne--inn of A-1 Roof Trnsse
Joa I russ I russ I ype Uty cry ua/'I U/ZU21
CRMSBSB2 GB LACK 1 1 2545
T
7
T
O
T
T
i
4_,
C
12
�- 1'5-9/16" w I m 3' -1
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C KZt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 35 0.15 3.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Shim all supports to solid bearing.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.003 D 999 36
VERT(CL): 0.004 D 999 24
HORZ(LL): 0.002 D - -
HORZ(TL): 0.003 D
Creep Factor: 2.0
Max TC CSI: 0.410
Max BC CSI: 0.058
Max Web CSI: 0.000
Wgt: 12.6 Ibs
VIEW Ver: 20.02.01A.1209.11
I.,
T
T
N
T
T
z.;
LO
N
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 234 /- /- /209 /155 /155
D 42 /- /- /23 /3 /-
C 63 /- /- /38 /82 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 39 0 B-C 28 -99
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B -D 10 -8
`*WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r:nnvdnht n 2016 A-1 Rnnf Tmccnc - Renrnd-1— of thi., dnnimant in anv fnnn . nroh,hit,d with—t the whf ,.n rem inn of A-1 Rnnf Trcv
Job 1 russ I runs 1 We Qry rry Ubrl ulzuz 1
CRMSBSB2 J5 JACK 1 1 2546
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
4.3T6"
1r5-9/1 6"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Stal End(ft)
BC 58 0.15 5.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
5-
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.007 D
HORZ(TL): 0.008 D
Creep Factor: 2.0
Max TC CSI: 0.572
Max BC CSI: 0.256
Max Web CSI: 0.000
Wgt: 18.2 Ibs
VIEW Ver: 20.02.01A.1209.11
C
♦ Maximum Reactions (Ibs)
Gravity
Loc R+ / R- / Rh
Non -Gravity
/Rw /U /RL
B 299 /- /-
/248 /179 /229
D 77 /- /-
137 /2 /-
C 127 /- /-
/86 /163 /-
Wind reactions based on MWFRS
B Brg Width = 3.5
Min Req = 1.5
D Brg Width = 1.5
Min Req = -
C Brg Width = 1.5
Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A-B 39 0 B-C 57 -163
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional er ineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav KHstam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvrinht n 2016 A-1 Roof Tmaces — RPnrndnotinn of this doonment in anv form is nrnhihitad witho t the wHf.n n is mn of A-1 Roof T.—s
Job I russ I russ l ype uty cry US/'I U/LU2 1
CRMSBSB2 J5A JACK 1 1 I 2547
= 2X4(A'
4-„
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 58 0.15 5.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
5' _ I
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.010 C
HORZ(TL): 0.011 C
Creep Factor: 2.0
Max TC CSI: 0.624
Max BC CSI: 0,358
Max Web CSI: 0.000
Wgt: 15.4 Ibs
VIEW Ver: 20.02.01A.1209.11
1
r
M
O
i
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 197 /- /-
/126 /87 /183
C 80 /- 1-
/44 /9 /-
B 136 /- /-
/97 /171 /-
Wind reactions based on MWFRS
A Brg Width = 3.5
Min Req = 1.5
C Brg Width = 1.5
Min Req = -
B Brg Width = 1.5
Min Req = -
Bearing A is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-B 61 -170
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A-C 0 0
'*WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineedn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvnnht n 211C A-1 Rnnf Trr,. _v - Rnnrntlunlinn of thi., dnnnment in anv form is nrnhihit.d without the written nenniscinn of A-1 Rnnf Trutce<
Job I rubb I r usb I ype ury rry UJ/ I U/LUL I
CRMSBSB2 J5B JACK 2 1 2548
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
co
M
O
�-- 1'5-9/16"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 60 0.15 5.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Shim all supports to solid bearing.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Sid: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
5'
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.019 D 999 36,
VERT(CL): 0.021 D 999 24,
HORZ(LL): -0.011 D - -
HORZ(TL): 0.013 D
Creep Factor: 2.0
Max TC CSI: 0.535
Max BC CSI: 0.292
Max Web CSI: 0.000
Wgt: 19.6 Ibs
VIEW Ver: 20.02.01A.1209.11
C
♦ Maximum Reactions (Ibs)
Gravity
Loc R+ / R- / Rh
Non -Gravity
/Rw /U /RL
B 300 /- /- /245 /180 /229
D 77 /- /- /38 /7 /-
C 125 /- /- /86 /158 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 39 0 B-C 56 -158
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B-D 19 -16
—WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Vent' design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Con—irt Cc 2016 A-1 Roof Tmssws - R"nrnd,,otinn of this dot. ment in anv formis prohibited without the wnttan narmissinn of AA Roof Tms[
Job I cuss I runs I ype Uty NIy UJ/1U/2U21
2549
CRMSBSB2 J7 EJAC 1 1
4_3„
Loading Criteria (psr) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: 11
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Stal End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
7
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.020 D
HORZ(TL): 0.024 D
Creep Factor: 2.0
Max TC CSI: 0,572
Max BC CSI: 0.495
Max Web CSI: 0.000
Wgt: 23.8 Ibs
VIEW Ver: 20.02.01A.1209.11
C
1
v�
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 371 /- /- /292 /211 /303
D 109 I- /- /54 /4 /-
C 189 I- /- /131 /238 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A-B 39 0 B-C 84 -211
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B -D 0 0
"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 84946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
Cnnvnaht 0 2016 A-1 Rnnf TniceP, — R—rod-Amin of thi, dor,i ,nt in anv form is nmhihit,d without th, wnttPn nP .,. no of A-1 Roof Toicc
Job
CRMSBSB2
n usb
J7B
hubs iypu
EJAC
Wfy riy U01 i uf4U4 t
1 1
2550
Loading Criteria (psr)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NCBCLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
4_3„
1'5-9/16"
7'
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP M-30;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.15 7.00
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Shim all supports to solid bearing.
Code / Misc Criteria
Code: FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.056 D 999 36,
VERT(CL): 0.071 D 999 24,
HORZ(LL): -0.032 D - -
HORZ(TL): 0.040 D
Creep Factor: 2.0
Max TC CSI: 0.550
Max BC CSI: 0,537
Max Web CSI: 0.000
Wgt: 25.2 Ibs
VIEW Ver: 20.02.01A.1209.11
C
11
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 372 /- /- /289 /211 /303
D 109 /- /- /56 /8 /-
C 187 /- /- /131 /233 /-
Wind reactions based on MWFRS
B Brg Width = 3.5 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A- B 39 0 B- C 84 - 207
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - D 26 - 25
*"WARNING" Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ('BUYER") ACKNOWLEDGMENT' form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvnaht n 2n16 A-1 Ronf Tnissos - Rnnmdnntinn of this dnnimaM in anv fn- is ornhihited withnut the written n—ission of A.1 Ronf Tni—,
ion I russ I russ 1 ype wfy rry U6/ I U/LUZ I
CRMSBSB2 Vol GABL 1 1 2551
6_P/ =" 8'9-1/16" 8'9-1/16" 71- 4.1
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Plating Notes
All plates are 1.5X3 except as noted.
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 18.71
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for gable wind bracing and other
requirements.
9'6-1 /8"
Code / Misc Criteria
Code:FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Factors Used: Yes
FT/RT:10(0)/10(10)
Plate Type(s):
WAVE
E=4X4
18'8-9/16" _I
9'2-3/8"
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): -0.008 J 999 360
VERT(CL): 0.015 J 999 240
HORZ(LL): 0.004 J - -
HORZ(TL): 0.005 J
Creep Factor: 2.0
Max TC CSI: 0.167
Max BC CSI: 0.113
Max Web CSI: 0.065
Wgt: 88.2 Ibs
VIEW Ver: 20.02.01A.1209.11
♦ Maximum Reactions (Ibs), or *=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
R* 76 /- /- /37
/50 /9
Wind reactions based on MWFRS
R Brg Width = 224 Min Req = -
Bearing R is a rigid surface.
Maximum Top Chord Forces Per
Ply (Ibs)
Chords Tens.Comp. Chords
Tens. Comp.
A-B 124 -170 E -F
210 0
B -C 98 -33 F-G
116 -7
C-D 121 -8 G-H
99 -34
D-E 214 0 H - 1
125 -168
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
A-Q
222 -105
M-L
241
-113
Q-P
233 -110
L-K
236
-111
P-O
239 -112
K-J
231
-110
O-N
243 -114
J - 1
219
-104
N-M
241 -113
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
E -M 0 -139
Maximum Gable Forces Per Ply (Ibs)
Gables Tens.Comp. Gables Tens. Comp
B-Q 312 -197 L -F 273 -123
C - P 210 - 99 K - G 208 - 98
D - O 269 -121 J - H 308 -198
"'WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-11. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved.. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
C.nn ht n 2n1R A-1 Rnn(Tnitsr_a - RenrndllMinn of Ihic dnnnment in anv form m nrohihited without the wntten nenni, e,nn of A-1 Rnnf Tniea
Job
CRMSBSB2
I Huss I russ I We Ury rly
V02 VAL 1 1
U31 IU/LUL I
2552
Loading Criteria (psf)
TCLL: 20.00
TCDL: 10.00
BCLL: 0.00
BCDL: 7.00
Des Ld: 37.00
NC13CLL: 10.00
Load Duration: 1.25
Spacing: 24.0 "
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
6-P/10" 69-1 /16"
C= 3X4
�-,-2X4(D81R) G 1112X4 F 1112X4
14'8-9/16"
r 610-1/4"—3'0-5/16"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 25.00 ft
TCDL: 5.0 psf
BCDL: 4.2 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Start(ft) End(ft)
BC 75 0.00 14.71
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for valley details.
69-1 /16" 717/16"
5'10"
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): -0.028 F 999 360
Loc R+ / R- / Rh / Rw / U / RL
H* 76 /- /- /36 /48 /9
Rep Factors Used: Yes
VERT(CL): 0.048 F 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.011 F - -
Wind reactions based on MWFRS
Plate Type(s):
HORZ(TL): 0.017 G
H Brg Width = 176 Min Req = -
WAVE
Creep Factor: 2.0
Bearing H is a rigid surface.
Max TC CSI: 0.467
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.251
Chords Tens.Comp. Chords Tens. Comp.
A - B 306 -508 C - D 188 -201
Max Web CSI: 0.202
Wgt: 53.2 Ibs
B - C 184 -195 D - E 306 - 504
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.02.01A.1209.11
A - G 580 -199 F - E 579 -199
G - F 595 - 208
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
B - G 680 - 379 F - D 662 - 374
"WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineehn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
r:nnvrinht n 2M6 A-1 Roof Tmsces — Renrodnofinn of this tlnraiment in anv fnrrn is nmhihitwf withait thF• written ne.--ion of A-1 Roof To,c %
Jon I russ I russ I ype Uty my U:d/1U/2U21
2553
CRMSBSB2 V03 VAL 1 1
6-p/lg' 4'9-1/16" 14'9-1/16" i /W
NZ
B=4X4
10'8-9/16" NEI
i- 62-5/8" 3i /211 52-3/8"
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
TCLL: 20.00
Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl
L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.027 D 999
360
Loc R+ ! R- / Rh / Rw / U / RL
E* 76 !- /- /35 /46 /8
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.037 D 999
240
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.010 D -
-
Wind reactions based on MWFRS
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.013 D
E Brg Width = 128 Min Req = -
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Bearing E is a rigid surface.
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.497
Maximum Top Chord Forces Per Ply (Ibs)
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.383
Chords Tens.Comp. Chords Tens. Comp.
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
A - B 420 -473 B - C 429 -481
C&C Dist a: 3.00 ft
Max Web CSI: 0.235
Loc. from endwall: not in 4.50
Wgt: 37.8 Ibs
GCpi: 0.18
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 20.02.01A.1209.11
Wind Duration: 1.60
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - D 559 -326 D - C 569 -333
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
Purlins
B - D 789 -581
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacirl oc) Start(ft) End(ft)
BC 75 0.00 10.71
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for valley details.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineenn
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Knstam, P.E.
responsibility of the Owner, the Owners authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in Ti
Convn,ht n 201a A-1 Roof Tnrtse� — Re md,iotlon of thi, rinrument in env form is nrohihit.d without the wnftan nertnL jinn of A-1 Roof Tnrs�es.
Job
CRMSBSB2
I fuss I russ I ype vary rry
VO4 VAL 2 1
UJ/ I U%LUL I
2554
6f15/16" 2'9-1/16"---I--- 2'9-1/16" - f- /191
E
12
6 B=4X4
02X4(MR)
III 1.5X4
68-9/16" -I
1 32-5/8" f $1 32-3/8"
Loading Criteria (psf)
Wind Criteria
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
TCLL: 20.00
Wind Std: ASCE 7-16
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 10.00
Speed: 160 mph
TPI Std: 2014
VERT(LL): -0.006 D
999 360
Loc R+ / R- / Rh / Rw / U / RL
E* 76 /- /- /34 /41 /8
BCLL: 0.00
Enclosure: Closed
Rep Factors Used: Yes
VERT(CL): 0.009 D
999 240
BCDL: 7.00
Risk Category: II
FT/RT:10(0)/10(10)
HORZ(LL): -0.002 D
- -
Wind reactions based on MWFRS
EXP: C Kzt: NA
Plate Type(s):
HORZ(TL): 0.003 D
E Brg Width = 80.0 Min Req = -
Des Ld: 37.00
Mean Height: 25.00 ft
WAVE
Creep Factor: 2.0
Bearing E is a rigid surface.
9 9
NCBCLL: 10.00
TCDL: 5.0 psf
Max TC CSI: 0.194
Maximum Top Chord Forces Per Ply (Ibs)
Load Duration: 1.25
BCDL: 4.2 psf
Max BC CSI: 0.152
Chords Tens.Comp. Chords Tens. Comp.
Spacing: 24.0 "
MWFRS Parallel Dist: 0 to h/2
A - B 165 -197 B - C 172 -196
C&C Dist a: 3.00 ft
Max Web CSI: 0.127
Loc. from endwall: not in 4.50
Wgt: 23.8 Ibs
GCpi: 0.18
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 20.02.01A.1209.11
Wind Duration: 1.60
Chords Tens.Comp. Chords Tens. Comp.
Lumber
A - D 282 -119 D - C 291 -125
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Webs: 2x4 SP #3;
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
Purlins
B - D 427 -268
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacir in oc) Start(ft) Eri
BC 75 0.00 6.71
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for valley details.
**WARNING** Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise staled on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kiistam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field 488906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPIA defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1.
(:nnvnoht n Pntfi A-1 Roof Tmsses - RenmAnrtinn of this Anniment in anv torn is nrnhihitetl without the wni nennission of A-1 Roof Tniss-
Job I russ I russ I ype Uty NIy U3/1 1
CRMSBSB2 V05 VAL 5 1 2555
T
8-1/4"
i==19=1 /4"
Loading Criteria (psf) Wind Criteria
TOLL: 20.00 Wind Std: ASCE 7-16
TCDL: 10.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 7.00 Risk Category: 11
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 25.00 ft
NCBCLL: 10.00 TCDL: 5.0 psf
Load Duration: 1.25 BCDL: 4.2 psf
Spacing: 24.0 " MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2;
Bot chord: 2x4 SP #2;
Purlins
In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows:
Chord Spacing(in oc) Stai End(ft)
BC 33 0.00 2.71
Apply purlins to any chords above or below fillers
at 24" OC unless shown otherwise above.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See Al Std Detail for valley details.
F-15/16�'S-1/16 9-1/16 7-7/16l
12
6
�2X4NR g 2X4(D8R)
A ) = 3X4
i 2'8-9/16"
Code / Misc Criteria
Defl/CSI Criteria
♦ Maximum Reactions (Ibs), or *=PLF
Code: FBC 7th Ed. 2020 Res.
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TPI Std: 2014
VERT(LL): 0.001 999 360
Loc R+ / R- / Rh / Rw / U / RL
D* 76 /- /- /28 /22 /5
Rep Factors Used: Yes
VERT(CL): 0.003 999 240
FT/RT:10(0)/10(10)
HORZ(LL): 0.001 - -
Wind reactions based on MWFRS
Plate Type(s):
HORZ(TL): 0.001
D Brg Width = 32.0 Min Req = -
WAVE
Creep Factor: 2.0
Bearing D is a rigid surface.
Max TC CSI: 0.034
Maximum Top Chord Forces Per Ply (Ibs)
Max BC CSI: 0.056
Chords Tens.Comp. Chords Tens. Comp.
A - B 150 -113 B - C 149 -111
Max Web CSI: 0.000
Wgt: 7.0 Ibs
Maximum Bot Chord Forces Per Ply (Ibs)
VIEW Ver: 20.02.01A.1209.11
Chords Tens.Comp.
A-C 119 -127
"'WARNING"• Please thoroughly review the "A-1 ROOF TRUSSES ("SELLER"), GENERAL TERMS and CONDITIONS CUSTOMER ("BUYER") ACKNOWLEDGMENT" form.
Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine
connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineerin
responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the Rama Pranav Kristam, P.E.
responsibility of the Owner, the Owner's authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field # 88906
use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and 4451 St. Lucie Blvd, Suite 201
guidelines of the Building Component Safety Infornation (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Fort Pierce, FL 34946
Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the
Building Designer or Truss System Engineer of any building. All capitalized terns are as defined in TPI-1.
Cnnvrinht n 2016 A-1 Rnnf Toms,.., - R—durtinn of thie dnnument in anv fnrn I.., nmhihited without the written of A-1 Rnnf Tni«es
10/28/2020 HIP/ KING JACK (TYPICAL) STDL 01.0
e
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL. 34946
(772)409-1010
ATTACH END JACKS USING (4)
0.131" 0 TOE NAILS AT TOP
CHORD & (3) 0,131" O TOE
NAILS AT BOTTOM CHORD.
ATTACH KING JACK USING
(3) 0.131" O TOE NAILS AT
TOP CHORD & BOTTOM
CHORD.
ATTACH CORNER JACKS USING
(2) 0.131" O TOE NAILS AT TOP &
BOTTOM CHORDS (TYP).
CORNERSET GENERAL SPECIFICATIONS:
MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60'
MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
5/28/2020 HIP/ KING JACK (HVHZ) STDL 02.2
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL. 34946
(772)409-1010
ATTACH KING & END JACK
WITH (1) THJA26 HANGER
OR EQUIVALENT AT
BOTTOM CHORD
ATTACH KING & END JACKS
WITH (1) LSTA12 TWIST STRAP
AT TOP CHORD WITH (10) 1Od
NAILS PER STRAP (MIN.) & (3)
0.131" 0 TOE NAILS.
ATTACH CORNER JACKS &
STD. JACKS WITH (1) LSTA12
TWIST STRAP AT TOP CHORD
& BOTTOM CHORD WITH (10)
1 Od NAILS PER STRAP
MINIMUM (TYP).
HIGH VELOCITY HURRICANE ZONE CORNERSET SPECIFICATIONS:
MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60,
MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT,
NOTE: IN ADDITION TO STRAPPING TOE- NAIL
BOTH CHORDS OF CORNER JACKS TO CARRYING
MEMBER PER THE FOLLOWING SCHEDULE:
• 2X4: (2) 0.131" 0 TOE NAILS
• 2X6: (3) 0.131" 0 TOE NAILS
LSTA12 TWIST STRAP WITH 1 OD NAILS,
MIN. (10). SEE MFR'S
RECOMMENDED CONNECTION.
HIP, OR KING JACK (TYP.)
JACK, OR CORNER JACK (TYP.)
IMPORTANT NOTE:
CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6--
2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED
PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS
IN HIGH VELOCITY HURRICANE ZONE.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
'FEBIRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03
A4#
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD,
FORT PIERCE, FL 34946
772409-1010
ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD
1'-3'MAX.
OIAG. BRACE
AT 1/3 POINTS
IF NEEDED
IT IS THE RESPONSIBILITY OF THE BLDG.
DESIGNER OR THE PROJECT ENGINEER/ARCHITECT
TO DESIGN THE CEILING DIAPHRAGM AND ITS
ATTACHMENT TO THE TRUSSES TO RESIST ALL
OUT OF PLANE LOADS THAT MAY RESULT FROM
THE BRACING OF THE GABLE ENDS.
HORIZONTAL BRACE
(SEE SECTION A -A)
END WALL
TRUSSSES @
24' O.C.
2X6 DIAGONAL BRACE SPACED 4B'
O.C. ATTACHED TO VERTICAL WITH
(4) - 16d NAILS, AND ATTACHED TO
BLOCKING WITH (5) - 10d COMMONS.
NAIL DIAGONAL BRACE TO
PURLIN WITH TWO 16d NAILS.
2X4 PURLIN FASTENED TO FOUR
TRUSSES WITH (2) - 16d NAILS
EACH. FASTEN PURLIN TO BLOCKING
W/ (2) - 16d NAILS (MIN.).
PROVIDE 2X4 BLOCKING BETWEEN
THE TRUSSES SUPPORTING THE
BRACE AND THE TWO TRUSSES ON
EITHER SIDE AS NOTED. TOENAIL
BLOCKING TO TRUSSES WITH (2) -
10d NAILS AT EACH ENO. ATTACH
DIAGONAL BRACE TO BLOCKING WITH
(5) - 10d COMMON WIRE NAILS.
CEILING SHEATHING
BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES
STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED:
METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE
OF THE STRUCTURAL GABLE AND FASTEN PER THE
FOLLOWING NAIL SCHEDULE.
METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL
MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING
NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG
SIZE, GRADE, AND SPECIES AS THE TRUSS VERTICALS. VERTICAL
NAILING SCHEDULE:
- FOR WIND SPEEDS 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE
7-10) OR LESS, NAIL ALL MEMBERS WITH ONE ROW OF 10d (.131'
X 3') NAILS SPACED 5' O.C.
- FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150
MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF 10d
(.131'X3') NAILS SPACED 6' O.C. (2X4 STUDS MINIMUM).
STRUCTURAL
GABLE TRUS'.
MAXIMUM STUD LENGTHS ARE LISTED ON PAGE 1. ALI
BRACING METHODS SHOWN ON PAGE 1 ARE VALID
AND ARE TO BE FASTENED TO THE SCABS OR
VERTICAL STUDS OF THE STANDARD GABLE TRUSS
ON THE INTERIOR SIDE OF THE STRUCTURE.
NOTE: THIS DETAIL IS TO BE USED ONLY FOR
STRUCTURAL GABLES WITH INLAYED
STUDS. TRUSSES WITHOUT INLAYED
\S ARE NOT ADDRESSED HERE. /
STANDARD GABLE /
TRUSS
UKAL
TRUSS
.1- , - aTUD
AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING
MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF
THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS.
THE BRACING SHOWN IN THIS DETAIL IS FOR
VERTICAL/STUDS ONLY.
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
12/23/19 PIGGY -BACK TRUSS STDT1t_04.1 ,i
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-444-1010
PIGGY -BACK DETAIL (TYPICAL)
180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
OR...
160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG.
LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00.
IMPORTANT NOTE:
TOP CHORDS OF TRUSSES SUPPORTING PIGGY -BACK CAP TRUSSES MUST BE ADEQUATELY
BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL
PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY
RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS.
MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C.
DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA,
STEEPLE, CHIMNEY OR DRAG STRUT LOADS.
"REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY -BACK AND BASE
TRUSS SPECIFICATIONS.'
PIGGY -BACK TRUSS. (REFER
TO ACTUAL TRUSS DESIGN
DRAWINGS FOR ADDITIONAL
INFORMATION.)
2'-0"
MAX
OPTION NO. 1 - TEE-LOK
3" x 8" TEE-LOK MULTI -USE CONNECTION PLATES SPACED
AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO
PIGGY -BACK TRUSS AT 4'-0" O.C. STAGGERED FROM
EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH
6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE
MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8"
TEE-LOK MULTI -USE CONNECTION PLATE (MINIMUM OF 2
PLATES) .
OPTION NO. 2 - APA RATED GUSSET:
8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS
EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d
COMMON (0.1 13" x 2") NAILS PER GUSSET: 4 (EACH) AT
CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP
CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C.
FRONT TO BACK FACES. MINIMUM TWO (2 EA.)
CONNECTIONS AT EACH TRUSS.
OPTION NO. 3 - 2X4 VERTICAL WOOD SCAB:
2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE.
ATTACH AT 8'-0" O.C. w/6 (EACH) 1 Od BOX NAILS (0.128"
x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND
3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE
STAGGERED 4'-0" O.C. FRONT TO BACK FACES.
MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS.
OPTION #1: TEE-LOK MULTI -USE
CONNECTION PLATE.
OPTION #2: APA RATED GUSSET.
OPTION #3: 2X4 VERT. SCAB.
ATTACH EACH PURLIN TO TOP
CHORD OF BASE TRUSS. PURLIN
& CONNECTIONS BY OTHERS.
BASE TRUSS. (REFER TO TRUSS
DESIGN DRAWINGS FOR
ADDITIONAL INFORMATION.)
PURLINS SPACED ACCORDING
TO MAX. SPACING OF TOP
CHORD OF BASE TRUSS.
SPACING IS NOT TO EXCEED 24"
O.C. & PURLINS TO BE LOCATED
AT JOINT OF EACH BASE TRUSS.
** IMPORTANT NOTE **
THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES
SPACED AT 24" O.C. OR LESS.
Rama Pranav Kristam, P.E.
488906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JULY 17, 2017 1 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05
AAO=
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
VALLEY TRUSS
(TYPICAL)
SECURE VALLEY TRUSS
W/ ONE ROW OF 10d
NAILS 6" O.C.
GABLE END, COMMON
TRUSS, OR GIRDER
TRUSS
DETAIL A
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2, WOOD SCREW = 4.5" SDS25412 SIMPSON OR
EQUIVALENT.
3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES.
4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND
SECURE TO BASE TRUSSES AS PER DETAIL "A".
5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE
INDIVIDUAL DESIGN DRAWINGS.
6. NAILING DONE PER NDS - 01.
7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
BASE TRUSSES
^"^'_E END, COMMON
3S, OR GIRDER TRUSS
TRUSS CRITERIA:
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
MAX TOP CHORD TOTAL LOAD = 50 PSF
ATTACH 2X4 CONTINUOUS #2 MAX SPACING = 24" O.C. (BASE AND VALLEY)
SYP TO THE ROOF W/ TWO MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
SIMPSON SDS25412 (1/4" X 4.5")
OR EQUIVALENT WOOD SCREWS
INTO EACH BASE TRUSS.
Rama Pranav Kristam. P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
FEBRUARY 5, 2018 ► TRUSSED VALLEY SET DETAIL
STDTL061-
GENERAL SPECIFICATIONS:
1. NAIL SIZE = 3" X 0.131" = 10d
2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT.
3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL_
„A„
4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN
DRAWINGS,
jA#= 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT
TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING.
A-1 ROOF TRUSSES 6. NAILING DONE PER NDS - 01.
4451 ST. LUCIE BLVD. GABLE END, COMMON
FORT PIERCE, FL 34946 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C.
TRUSS, OR GIRDER
772-409-1010 TRUSS 7
SECURE
W/(
VALLEY TRUSS —v I tl �� II I II IIBASE TRUSSES
(TYPICAL) II
(NO SHEATHING) N.T.S.
GABLE END, COMMON
TRUSS, OR GIRDER
P r2 VALLEY TRUSS TRUSS
(TYPICAL)
SEE DETAIL "A"
BELOW (TYP.)
WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH
WIND DESIGN PER ASCE 7-10: 170 MPH
MAX MEAN ROOF HEIGHT = 30 FEET
ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12
CATERGORY II BUILDING
EXPOSURE C
WIND DURATION OF LOAD INCREASE: 1.60
ATTACH 2X4 CONTINUOUS #2
MAX TOP CHORD TOTAL LOAD = 50 PSF
SYP TO THE ROOF W/ TWO
MAX SPACING = 24" O.C. (BASE AND VALLEY)
SIMPSON SDS25300 (1/4" X 3")
MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES.
OR EQUIVALENT WOOD
SCREWS INTO EACH BASE
TRUSS.
Rama Pranav Kristam. P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
JULY 17, 2017 I ` (HIGH WIND VELOCITY)
STDTL07
A-1 ROOF TRUSSES
4451 ST, LUCIE BLVD,
FORT PIERCE, FL 34946
772-409.1010
ATTA(
WIND DESIGN PER ASCE 7-98, ASCE 7-
WIND DESIGN PER ASCE 7-10: 170 MPI
MAX MEAN ROOF HEIGHT = 30 FEET
CATERGORY II BUILDING
EXPOSURE B OR C
WIND DURATION OF LOAD INCREASE:
MAX TOP CHORD TOTAL LOAD = 50 PSI
MAX SPACING = 24" O.C. (BASE AND VP
Z)W'I'UK I INU I KUJJCJ UIKCI.1 LT UNUCK VHLLCT I KUJJCJ MUJ I [SC
DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED
TOP CHORDS.
NOTES:
1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES.
2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER.
FOR BEVELED BOTTOM
CHORD, CLIP MAY BE APPLIED
TO EITHER FACE.
CLIP MAY BE APPLIED
TO THIS FACE UP TO A
NON -BEVELED MAXIMUM 6/12 PITCH NON -BEVELED
BOTTOM CHORD u I I BOTTOM CHORD
CLIP MUST BE APPLIED TO
THIS FACE WHEN PITCH
EXCEEDS 6/12 (MAXIMUM
12/12 PITCH)
Rama Pre 'stam, P.E.
4889
4451 St. Lucie Blvd, Sul C
Fort Pierce, FL 34946
FEBRUARY 17, 2017 1 STANDARD GABLE END DETAIL 1 STDTL08
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TYPICAL 2X4 L-BRACE
NAILED TO 2X4 VERTICALS
W/SOd NAILS, 6' O.C.
VERT
STUD
SECTION B-B
TRUSS GEOMETRY AND CONDITIONS
SHOWN ARE FOR ILLUSTRATION ONLY.
VERTICAL
2X6 SP OR SPF
STUDPBRACE
#2 DIAGONAL
BRACE
(4) - 16d
NAILS16d
NAILS
SPACED 6' O.C.
(2) lOd NAILS
INTO 2X62X6
SP OR
SPF #2
2X4 SP OR
SPF #2L
HORIZONTAL
NAILED TO
RTICALS
SECTION A -A
W/(4) - IOd NAILS
DIAGONAL BRACE 4' - 0' D.C. MAX.
SEE INDIVIDUAL ENGINEERING DRAWINGS
FOR TRUSS DESIGN CRITERIA.
12 PROVIDE 2X4 BLOCKING BETWEEN
q Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED.
* TOENAIL BLOCKING TO TRUSSES
WITH (2) - 10d NAILS AT EACH END.
ATTACH DIAGONAL BRACE TO
BLOCKING WITH (5) - 10d NAILS
A
(4) Bd NAILS MINIMUM, ROOF
3X4= PLYWOOD SHEATHING TD r SHEATHING
B 2X4 STD SPF BLOCK 1
* DIAGONAL BRACING ** L - BRACING REFER v
V tt t
xh
/
REFER TO SECTION A -A TO SECTION B-B 24' MAX.
NOTE:
/
1. MINIMUM GRADE OF #2 MATERIAL IN H TGABLE
lOd
2. CONNECTION BETWEEN BOTTOM CHORD F END TRUSS AND WALL TO
12' MAX.
NAILS
BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT.
3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG.
ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF
SYSTEM.
4. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR
/
BETTER WITH ONE ROW OF lOd NAILS SPACED 6' O.C.
/ TRUSSES @ 24' O.C.
5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM
AT4'-0'O.C.
6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN
2X6 DIAGONAL BRACE
WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT
SPACED 4B' O.C. ATTACHED
THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE
_ TO VERTICAL WITH (4) -
STUDS WITH (3) 10d NAILS THROUGH 2X4 (REFER TO SECTION A -A)
16d NAILS, AND ATTACHED
7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240.
TO BLOCKING WITH (5) -
B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAG.
BRACE
10d NAILS.
9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3
POINTS
TRUSSES. IF
NEEDED
10. 10d AND 16d NAILS ARE 0.131'X3.0' AND 0.131'X3.5' COMMON WIRE NAILS
HORIZONTAL BRACE
RESPECTIVELY.
(SEE SECTION A -A)
11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12
BY SPIB/ALSC.
MINIMUM STUD
SIZE SPECIES
AND GRADE
STUD
SPACING
WITHOUT
BRACE
2X4
L - BRACE
DIAGONAL
BRACE
(2) DIAGONAL
BRACES AT
1/3 POINTS
MAXIMUM STUD LENGTH
2X4 SP #3 / STUD
12" O.C.
3-8-10
5-6-11
6-6-11
11.1.13
2X4 SP #31 STUD
1 16" O.C.
3.3.10
4-9.12
6-6-11
9-10.15
2X4 SP #3 / STUD
24" O.C.
2-8-6
3-11-3
5-4.12
8.1-2
2X4 SP #2
12" O.C.
3-10-15
5-6-11
6-6-11
11-8-14
2X4 SP #2
16" O.C.
3-6-11
4.9.12
6-6-11
10.8-0
2X4 SP #2
24" O.C.
1 3-1-4
1 3-11-3
1 6.2-9
9-3-13
DIAGONAL BRACES OVER 6' - 3- REQUIRE A 2X4 T-BRACE ATTACHED TO ONE
EDGE. DIAGONAL BRACES OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO
BOTH EDGES. FASTEN T AND I BRACES TO NARROW EDGE OF DIAGONAL BRACE
WITH 10d NAILS 6' D.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER
90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 OR SP #2.
END WALL
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
MAX MEAN ROOF HEIGHT = 30 FEET
EXPOSURE B OR C
ASCE 7.10 190 MPH STUD DESIGN IS BASED ON COMPONENTS AND CLADDING.
DURATION OF LOAD INCREASE: 1.60 CONNECTION OF BRACING IS BASED ON MWFRS.
r
FE'BRUARY 17, 2017
T-
WITH 2X BRACE ONLY
STDTL09
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
NOTES:
T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING
IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER 90% OF WEB LENGTH.
THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO
CONTINUOUS LATERAL BRACED WEBS.
NAILING PATTERN
T-BRACE SIZE
NAIL SIZE
NAIL SPACING
2X4 OR 2X6 OR 2X8
10d
6" O.C.
NOTE: NAIL ALONG ENTIRE LENGTH OF T—BRACE / I —BRACE (ON
TWO—PLY TRUSSES NAIL TO BOTH PLIES)
NAILS
BRACE
SIZE FOR ONE -PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T—BRACE
2X4 I —BRACE
2X6
2X6 T—BRACE
2X6 I —BRACE
2X8
2X8 T—BRACE
2X8 I —BRACE
BRACE
SIZE FOR TWO-PLY
TRUSS
SPECIFIED CONTINUOUS ROWS OF
LATERAL BRACING
WEB SIZE
1
2
2X3 OR 2X4
2X4 T—BRACE
2X4 I —BRACE
2X6
2X6 T—BRACE
2X6 I —BRACE
2X8
2X8 T—BRACE
2X8 I —BRACE
T—BRACE / I —BRACE MUST BE SAME SPECIES
AND GRADE (OR BETTER) AS WEB MEMBER.
NAILS
WEB
NAILS
1( NAILS
WEB
I -BRACE T - RE �A,, Qam,P.E.
# 66906
4451 StLucie Blvd, Suite 201
.
SECTION OETAILSFcrtPierce,FL34946
FEBRUARY 17, 2017
LATERAL BRACING RECOMMENDATIONS I STDTL10 `
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2X6 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET
ALONG A FLOOR TRUSS.
NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE
TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY
OF THE METHODS ILLUSTRATED BELOW.
NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE
BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS
FROM END TO END, CONNECTED WITH A METHOD OTHER THAN METAL FRAMING ANCHOR, AND PROPERLY
CONNECTED, BY OTHERS, AT THE ENDS.
USE METAL FRAMING
ANCHOR TO ATTACH
TO TOP CHORD
BLOCKING BEHIND THE VERTICAL
WEB IS RECOMMENDED WHILE
NAILING THE STRONGBACK
USE METAL FRAMING
ANCHOR TO ATTACH
TO BOTTOM CHORD
TRUSS
INSERT WOOD SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (00 NOT
ATTACH TO VERTICAL ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS)
WEB WITH (3) - 10d SCAB WITH (3) - 10d
NAILS (0.131' X 3') NAILS (0.131' X 3'). r ATTACH TO VERTICAL
WITH (N IBLS (0.1313)X 3')
ATTACH TO VERTICAL
WEB WITH (3) - 10d
NAILS (0.131' X 3')
ATTACH 2X4 VERTICAL
TO FACE OF TRUSS.
FASTEN TO TOP AND
BOTTOM CHORD WITH
(2) - 10d NAILS (0.131'
X 3') IN EACH CHORD
ATTACH TO VERTICAL
SCAB WITH (3) - 10d
NAILS (0.131' X 3')
2X6 4' - 0' WALL
STRONGBACK (TYPICAL SPLICE) (BY OTHERS)
ATTACH TO CHORD
WITH (2) #12 X 3'
WOOD SCREWS
(0.216' DIA.)
INSERT SCREW THROUGH
OUTSIDE FACE OF CHORD INTO
EDGE OF STRONGBACK (DO NOT
USE DRYWALL TYPE SCREWS)
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEQUATE SUPPORT,
DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - 0' LONG SCAB
CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0.131' X 3')
EQUALLY SPACED.
ALTERNATE METHOD OF SPLICING:
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) -
10d NAILS (0.131' X 3') STAGGERED AND EQUALLY SPACED (TO BE USED ONLY
WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL).
BLOCKING
(BY OTHERS)
Rama Pranav Kdstam, P.E.
4 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
�I STDTL11
FEBRUARY17,2017 LATERAL TOE -NAIL DETAIL
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409.1010
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45° WITH THE MEMBER
AND MUST HAVE FULL WOOD SUPPORT (NAIL MUST BE DRIVEN
THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER END AS
SHOWN).
2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL
BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO
SPECIES FOR MEMBERS OF DIFFERENT SPECIES.
TOE -NAIL SINGLE SHEAR VALUES
PER NOS 2001 (LB/NAIL)
DIA
SP
OF
HF
SPF
SPF-S
.131
88.0
80.6
69.9
68.4
59.7
o
J
.135
93.5
85.6
74.2
72.6
63.4
.162
108.8
99.6
86.4
84.5
73.8
r7
.128
74.2
67.9
58.9
57.6
50.3
0
p
J
.131
75.9
69.5
60.3
59.0
51.1
in
N
.148
81.4
74.5
64.6
63.2
52.5
n
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
THIS DETAIL IS ONLY APPLICABLE TO
THE THREE END DETAILS SHOWN BELOW.
VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY.
SIDE VIEW
(2X4) 3 NAILS
EXAMPLE: i NEAR SIDE
(3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES BOTTOM CHORD
NEAR SIDE
FOR LOAD DURATION INCREASE OF 1.15:
3 (NAILS) X 84.5 (LB/NAIL) X 1.15 (DOL) = 291.5 LB MAXIMUM CAPACITY NEAR SIDE
ANGLE MAY
VARY FROM
30° TO 60°
45.00'
SIDE VIEW
(2X6) 4 NAILS
NEAR SIDE
NEAR SIDE
NEAR SIDE
NEAR SIDE
ANGLE MAY
VARY FROM
30° TO 60°
45.00'
ma ranav Knstam, P.E.
q 88906
51 S . ucie Blvd, Suite 201
Fort PieKe, FL 3,4946
FEBRUARY 17, 2017 ( UPLIFT TOE -NAIL DETAIL I STDTL12
A-1 ROOF TRUSSES
4451 St LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
THIS DETAIL SHALL BE USED FOR A CONNECTION
RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER
IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS.
TOE -NAIL WITHDRAWAL VALUES
PER NOS 2005 (LB/NAIL)
DIA.
SP
OF
HF
SPF
SPF-S
0
.131
59
46
32
30
20
Z
O
J
.135
60
48
33
30
20
e
.162
72
58
39
37
25
J
2
O
.128
54
42
28
27
19
I-_
L7
Z
Z
JO
.131
55
43
29
28
19
LU
.148
62
48
34
31
21
-j
J_
N
Q
Z
.120
51
39
27
26
17
C�
z
.128
49
38
26
25
17
O
.131
51
39
27
26
17
J
.148
57
44
31
28
20
NOTES:
1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30° WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE
MEMBER END AS SHOWN.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION.
VALUES SHOWN ARE CAPACITY PER TOE -NAIL.
APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED.
EXAMPLE:
(3) - 16d NAILS (0.162' DIA. X 3.5') WITH SPF SPECIES TOP PLATE
FOR WIND DOL OF 1.33:
3 (NAILS) X 37 (LB/NAIL) X 1.33 (DOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
FOR WIND DOL OF 1.60:
3 (NAILS) X 37 (LB/NAIL) X 1.60 (DOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND
IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LEIS (177 LBS) BUILDING
DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION.
+►+►+ USE (3) TOE -NAILS ON 2X4 BEARING WALL
r+r+► USE (4) TOE -NAILS ON 2X6 BEARING WALL
NEAR SIDE
FAR S]
)E
TOP PLATE
OF WALL
VIEWS SHOWN ARE FOR
ILLUSTRATION PURPOSES ONLY
IL
NAIL
igWLm, P.E.
38906
44D i oi. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
SIDE VIEW
END VIEW
FEBRUARY 5, 2016 I TYP W NAILER ATTACHMENT I STDTLI3
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772-409-1010
1.0x4
2x2 NAILER ATTACHMENT
GENERAL SPECIFICATIONS
MAX LOAD: 55 psf Roof Load, 170 mph, ASCE
7-10, 29'-0" Mean Height, Exp. B, C or D.
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
April 11, 2016 I TYPICAL ALTERNATE BRACING DETAIL I STDTLI4
FO EXTERIOR FLAT GIRDER TRUSS
v " eI
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD. 12
ORT PIERCE, FL 34946
772-409-1010
F
VARIES
(4) 12d
TRUSS 24" O.C. --\ �i{ (4) 12d
UPLIFT CONNECTION
(SEE ROOF TRUSS)
EXTERIOR FLAT
GIRDER
MAX 3011 (21-611)
2x6 #2 SP (Both Faces)
24" O.C.
SIMPSON H5
Rama Pranav Kristam. P.E.
4451 St. Lucie Blvd, Suite 201
Fort Pierce, FL 34946
75RUARY 17, 2017
STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND I STDTLI5
DAMAGED OR MISSING CHORD SPLICE PLATES
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34W
772-409.1010
TOTAL NUMBER
OF NAILS EACH
SIDE OF BREAK
X
(INCHES)
MAXIMUM FORCE (LBS) 15% LOAD DURATION
SP
OF
SPF
HF
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
2X4
2X6
20
30
24"
1706
2559
1561
2342
1320
1980
1352
2028
26
39
30"
2194
3291
2007
3011
1697
2546
1738
2608
32
48
36"
2681
4022
2454
3681
2074
3111
2125
3187
38
57
42"
3169
4754
2900
4350
2451
3677
2511
3767
44
66
4B"
3657
5485
3346
5019
2829
4243
2898
4347
+� DIVIDE EQUALLY FRONT AND BACK
ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF
THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH 10d NAILS (TWO ROWS FOR 2X4, THREE
ROWS FOR 2X6) SPACED 4' O.C. AS SHOWN (.131' DIA. X 7).
STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN
THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE.
THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS)
THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C
�11a
ILI
TRUSS CONFIGURATION
AND BREAK LOCATIONS
FOR ILLUSTRATIONS ONLY
THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL TO
THE REQUIRED X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT
AND A MINIMUM OF S' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE).
DO NOT USE REPAIR FOR JOINT SPLICES
NOTES:
1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR
DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE
TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN
THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF
SUPPORTING THE LOADS INDICATED.
2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR
AND HELD IN PLACE DURING APPLICATION OF REPAIR. Rama Pranav Kristam, P.E.
3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID #88906
UNUSUAL SPLITTING OF THE WOOD. 4451 St. Lucie Blvd, Suite 201
4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID Fort Pierce, FL 34946
LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY.
6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS.
FEBRUARY 17, 2017 1 SCAB APPLIED OVERHANGS I STDTL16 ''
A-1 ROOF TRUSSES
4451 ST. LUCIE BLVD.
FORT PIERCE, FL 34946
772409-1010
TRUSS CRITERIA:
LOADING: 40-10-0-10
DURATION FACTOR: 1.15
SPACING: 24' O.C.
TOP CHORD: 2X4 OR 2X6
PITCH: 4/12 - 12/12
HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL
END BEARING CONDITION
NOTES:
1. ATTACH 2X-SCAB (MINIMUM #2 GRADE SPF, HF, SP, DF) TO ONE FACE OF TRUSS
WITH TWO ROWS OF 10d COMMON WIRE NAILS (.148' DIA. X 3') SPACED 6' O.C.
2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH
AS TO AVOID UNUSUAL SPLITTING OF THE WOOD.
3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO
AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES.
2X SC
NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED
WHEN OVERHANG HAS BEEN BROKEN OFF.
IMPORTANT
THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 40') SPACED 24'
O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD
LOADS NOT EXCEEDING 50 PSF.
TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY.
REFER TO INDIVIDUAL TRUSS DESIGN
FOR PLATE SIZES AND LUMBER GRADES
Rama Pranav Kristam, P.E.
# 88906
4451 St. Lucie Blvd, Suite 201
Fart Pierce, FL 34946