HomeMy WebLinkAbout7112-21-200-002- Soil Density - Busby ResidenceTested For: Marshall Landscapes
1563 SW Seagull Way
Palm City, Florida - 34990
Attention: Anthony Marshall
Title: Project Manager
Cc: Anthony Marshall (marshalllandscapeservices@€
General Location: Pool deck
Test Method: ASTM D-6938 (Nuclear)
Gauge Make: Troxler
Gauge Model: 3430 Gauge S/N: 28286
Vertical Reference:
Test Date Proctor Number
05/03/2021 L1 Grav fine sand
Test Elevation or Pepth
No Re -Test No I (Inch) Test Location
1
Pad
12
1 Center East side
2
Pad
12
Center North side
3
Pad
12
Center West side
4
Pad
12
Center South side
Field Compaction Tests
Report Date: 05/04/2021 Permit #: 2101-0159
Project #: 7112-21-200-002
Project: Busby Residence
Address: 18700 Mach 1 Drive
Port St. Lucie, Florida - 34987, United States
Inspector: Joel Hernandez
Field Activity Date: 05/03/2021
Project Specifications: 95 %
Modified Proctor(AASHTO T-180)
Retest Required: Yes X No
Soil Description
Max. Dry
Optimum
Density (pcf)
Moisture (/o)
102.0
11.0
Proctor
Field
Percent
Spec:95
Max
Field
Meet
Density
Proctor
Percent
Density
Compaction
7bs/ft^3)
(lbs/ft^3)
(%)
Spec ?
102.0
11.0
9.8
101.8
99.8
Yes
102.0
11.0
10.3
102.5
100.5
Yes
102.0
11.0
9.2
101.2
99.2
Yes
102.0
11.0
10.8
100.8
98.8
Yes
Remarks:
Notes: As requested, a representative from our company arrived on site as scheduled and performed the above test. These test results apply only to
the specific locations noted and do not represent any other location. Reports may not be reproduced except in full, without permission.
Report Copied to:
Harold Marsh
•�
*: 5M
p STATE O �AQ ZZ
� 10
lorida�ce &lio6381
2765 Vista Parkway, Suite H-10 • West Palm Beach, Florida 33411
561-687-8536 • www.TSFGeo.com
State of Florida Professional Engineers License # 28073