BLOWER DOOR TEST FORM
House Infiltration Test Certification e
Prescriptive and Performance Method
Date: Permit#: 1-
Contractor: a�� —(, ,►� ��
Job Address:
Construction: �� New Construction —Complete ( Existing—After Addition
House Infiltration Test Results SLC Climate Zone 2
CFM (50)_ Test Date: f 1 �� 1-'--1
Volume=
ACH (50)=CFM (50)x 60/Volume= s,� Mechanical Ventilation required less than 3 ACH
Passing results must be&ACH (50)or less (Pass ( ) Fail
FBC, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or(7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g)or(i) or an
approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building
thermal envelope.
FBC,Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w.c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation
the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3.
Testing Company
Company Name: Pro-Duct Services Address: 1915 Rio Vista Drive, Ft, Pierce, FL 34949 I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Sec on R402.4.1.2 Climate Zone 2.
Signature:
Printed Name: Martin Klein
License/Certification M. 5061633
Planning& Development Services
Building&Code Regulation Division
2300 Virginia Ave, Rm 201
Fort Pierce, FL 34992
772462-2165 Fax 772462-6443
e
FBC ENERGY CONSERVATION CODE
Duct sealing Certification
Prescriptive and Performance Method
Date: 1' A Pennil#: 'I-0 o d(t 2 Lot#: 2 �—
contractor: �o� �.�r l Address: 2 b A
Consh)cbm: ,most Construction Test ❑Rough-in Test
Test Conditions:
Date 21 Floor Area(ft2): 2 S
r
Time: i 1 :tf Primary Location of Supply Ductwork
Indoor Temperature(F): Primary Location of Return Ductwork r i1�✓
Outdoor Temperature(F): $1
Tout i eakacre Test(Otgodel
Duct Leakage: ❑Default �erop.Leak Free ja-Proposed On=
Test Pressure: _�.S(Pa)
Baseline Duct Pressure(optional) o(t (Pa)
Duct Press.(Pa) Flow Ring Fan Press Flow(cfm) Results:N+ass a Fail
Installed Pa r
Z d Total Leakage(cfm): C7
Total Leakage per 100 sgft: ev ° • t-�
CFM25 x 100 divided by the CFA=Duct LeaiuMp CF1W100 sgtt.
Te:;bno Ccetoarw n /' �c
�vwy fang; Pro-Dml Somees Addrw: t�J V i l.9 r w 1�. t_ i�� r t F� T�'
I hereby oerbfy that Bn ebm Duct 6selinp Leakep mw b detnonetmto complienoe whh P Edition FBC Energy Conseewrft MgrirenW&In aeeordenes wish
Section R40322.
WV __—
Prinded NW": Martin Klein LioenealCettltioate tf: 5061§33