HomeMy WebLinkAboutAPPROVED, Windload Docs - Don & Ruth Decker - 7403 Ocala AvenueCertified By
Florida Licensed Professional Engineer or Architect
FL16107 R14 Equiv 20200812 - EBg - A5TM 1886-1996 equiv pdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
02/16/2021
Date Validated
02/16/2021
Date Pending FBC Approval
02/22/2021
Date Approved
04/13/2021
Summary of Products
Go to Page = Page 2 / 3 10
FL #
Model, Number or Name
Description
16107.21
21 W8-16 DSIE-11`471: GD2SP,
Double -skin Insulated EPS (exterior skin 27 ga. min.; interior
GR2SP, GD2LP, GR2LP, AR2SP,
skin 27 ga. min,) Double -Car (9'2" to 16'2" wide) WINDCODEO
AR21P, ED2SP, ED21P, 4302, HDGL,
W8 Garage Door with Optional Impact -Resistant Lites
6202, MFC68, 4305, HDGR, 6205,
SFR68, MFR68
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R14 II 104786-Rev06.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by independent Third Party: No
Design Pressure: +46 PSF/-52 PSF
Evaluation Reports
Other: Max. Wind Speed (V ult): 170 MPH. Solid doors or
FL16107 R14 AE CBPC 130214-A.pdf
doors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.22
22 W6-09 DSIE-1F171: 4400, 4401,
Double -skin Insulated EPS (exterior skin 27 ga. min.; Interior
4301, 4300, 4301, 4310, HDG,
skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODEO W6
HDGL, HDGF, 66, 66G, 67, 67G, 68,
Garage Door with Optional Impact -Resistant Lites
SP200, SF200, SE200, 6200, 6201,
6203
Limits of Use
Installation Instructions
Approved for use in HVHZ; Yes
ELI6107 R14 11 101526-A-Rev22.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant; Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Max, Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 R14 AE CBPC 130214-A.pdf
doors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.23 23 W6-09 DSIE-1F171: 4400, 4401, Double -skin Insulated EPS (exterior skin 27 ga, min.; Interior
4300, 4301, 4310, HDG, HDGL, skin 27 ga, min.) Single -Car (up to 9'0" wide) WINDCODEO W6
HDGF, 66, 66G, 67, 67G, 68, SP200, Garage Door
SF200, SE200, 6200, 6201, 6203
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R14 II 101526-B-Rev22.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF aluatIonjR&ports... ..
Other: Doors with standard glazing-i�eet-the n load FL16107 R14 AE C-� el�ir'"13A2t4 A.pdf
iilding cocle but DO NOT meet the Impact Created by Independent Third Party:
for windborne debris regions,
16107.24 24 W6-09 PAN-21`153: 84A, 94, 73, Steel Pan (min, 25 ga.) Single -Car (up to 9'0" wide)
75, 1500, 190, 411ST, 4RSF, 4F, WINDCODEO W6 Garage Door with Optional impact_ Resistant
6RST, 6RSF, 48, 42, 55, 488, 42B, Lites
555, GOSS, GDSSV, GRSS, GRSSV,
ARSS, AR5SV, ED5S, EDSSV
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL16107 R14 II 10134 - e 19.p
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other; Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R14 AE CBPC 130214-A.pdf
doors with optional impact -resistant glazing are Impact- Created by Independent Third Party: No
-resistant (large missile impact), '
y
Z
'O;p
D
iH
Z
vm
.f .9
m
1 ^
m
0
rrrr
-\� Y 9
C • '
d
�^
F
A
L
m � b
N� gN rgs
E_l
Crl
N
0
n
L
§
�
§
\_ ` fi x Z
h w
k§\ /c) r 8\
`
:a
r \ © a \J./\ v.
©\\ iSol
!/|)�� �k )
)o ,,
.\i/ a \ t\ \ '(
\� '� ^t ( \
I;O= ) \ t #_ 0
J§: ! . ; g a
Lod
# z /a\
_
�)�) -
> _ ^
1 n I
n
�A
W
Fn
ebb
0~=9�
aR
9 M@s�
= �P52P
��z'�o8
�m
C) �
W
N
w
GIs
r.
< OPENING HUG Hf DOOR HEIGHT
0
w
February 14, 2013 (Revised 8/5/20)
Evaluation Report for Clopay Corporation Sectional Garage Doors, W6 through W8
I have evaluated the wind load door designs as shown on the drawings listed below. I
have reviewed the test reports, which were generated by accredited Independent
laboratories as required by the relevant Florida Administrative Rule, the engineering
rational analysis, and the product drawings. The test reports are listed below. Assembly
testing was conducted by American Test Lab North Carolina. Component testing was
conducted by HETI and ETC.
For the doors listed in Tables 1 through 5, Static Pressure Tests were conducted in
accordance with TAS 202-1994, ASTM-E330-2002 and ANSI/DASMA 108-2005. Missile
Impact and Cyclic Pressure Tests were conducted in accordance with TAS 201-1994
and TAS 203-1994 and ASTM E1886-2005 and ASTM E1996-2009 and ANSI/DASMA
115-2005. The pressures listed on the drawings are either direct results of these tests
or results obtained through engineering rational analysis based on actual tests. I have
concluded that the door designs listed below in Tables 1 t;hrough 5 are in compliance
with these High Velocity Hurricane Zone test requirements of the Florida Building Code
and therefore are qualified as Impact -resistant assemblies (large missile impact).
TABLE is
DPawinas
for
doorswj.�h
Manufactiarina
roduct
Code: (MPC)
PAN-2F153:
101348-A-Rev19,
max.
door
size 9'0""
x 1
0'; +38/-44 PSF
(des
g
o�ca
TABLE 2: Drawing
f r do
rs
Ifh
Manu aeturina
Pr duct
Gode
(MPC)
PAN-2F156:
load)
101348-A-Rev19,
max, door
size 9 0"' x 1
'0";
+38/-44
PSF (design
max. door size
gn
TABL 4
s-for"
i
ufa
to
P
oduc
Co
e"
P
D
IU-
s
104778-Rev059
maz. ,00r
size 16 2" x
16'0';
+46.-52
PSF
esign
load)
104785, A-Rev04, max. 'door size 16'2" x 16'U"; +38[-42 PSF (desi
104786-Rev06, max. door size 16'2" x 16'0"; +46/-82 PSF (design
For the doors in Tables 6 through 9, Static Pressure Tests were conducted in
accordance with ASTM-E330-2002 and ANSI/DASMA 108-2005. The pressures listed on
the drawings are either direct results of these tests or results obtained through
engineering rational analysis based on actual tests. I have concluded that the door
designs listed below in Tables 6 through 9 are in compliance with these test
requirements of the Florida Building Code.
TABLE 6: Drawings
ford
with
Manufacturing
Rroduct
Code
O•4PC)
2
153;
101348-i3-Rev19,
max.
:door
size
9`0"" x 16'0";
+38/--44
PSF (esign
load)
TA E 8' a
fo
doo
s
actinf
o c'C e
PC'
SIE-iF171:
101526-B-Rev22,
max.
oor
size 9 Q"' x 1
-0 +38/-44
PSF
(des gn load)
PACEl or3 Fae: CBPC 130214-A.4
EVALUATION REPORT FOR CLOPAY. CORPORATION SECTIONAL GARAGE DOORS, W6 - WS
TABLE
4:
Drawings
for
doors
with
Maniafact
ring Product
Code O
DSIE-1F471:
1047$S-B-Rev04,
max.
oor
size 16'2" x
16'0";
+38/-42 P5F
(design
load)
Test Reports:
ATL-0107.01-13 (2/20/13), ATL-1206.01-12 (1/23/13), ATL-0801.01-12 (8/15/12),
ATL-0827.01-12 (10/9/12), ATL-0115.01-13R (3/18/13), ATL-0117.01-13R (3/18/13),
These reports document compliance with the TAS testing standards and are signed and
sealed by David Johnson, FL PE 61915.
Product Description for doors with MPC PAN-2F153:
These doors consist of 2" thick steel pan sections with min. 25 ga. (0.019")
skins. The steel skin is at least G40 DDS per ASTM A653. The maximum section height
is 21". These doors may have optional Impact -Resistant Glazing (Molded). Optional
Impact -Resistant Glazing is a one-piece injection -molded front frame and glazing. The
following models are at least structurally equivalent to the tested door: 84A, 94, 98,
73, 75, 1500, 190, 4RST, 4F, 4RSF, 6RST, 6RSF, 48, 48B, 42, 42B, 55, 55S, GD5S,
3D5SV, GR5S, GR5SV, AR5S, ARSSV, ED5S, ED5SV. Not all models may be shown on
given drawing.
Pi`oduct Descriptjpn for doors with MPC-PAN-2F156:
These doors consist of 2" thick steel pan sections with min. 25 ga. (0.019")
skins. The steel skin is at least G40 DDS per ASTM A653. Sections may have 1-5/16"
insulation captured in the cavity of the pan section. The maximum section height is
21". These doors may have optional Impact -Resistant Glazing (Molded). Optional
Impact -Resistant Glazing Is a one-piece Injection -molded front frame and glazing, The
following models are at least structurally equivalent to the tested door: 76, 76V, 2RST.
Not all models may be shown on a given drawing.
Protluct Deseriotionfior doors with. MPC DSIE-SF171:
These doors consist of 2"double-skin Insulated sections with an EPS core
laminated to both skins. Both Inner and outer skins are min. 27 ga. (0.016") G40 DDS
per ASTM A653. The maximum section height Is 21". These doors may have optional
Impact -Resistant Glazing (Molded). Optional Impact -Resistant Glazing is a one-piece
injection -molded front frame and glazing. The following models are at least structurally
equivalent to the tested door: 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67,
67G, 68, 6200, 6201, 6203, SP200, SF200, SE200. Not all models may be shown on a
given drawing.
Product
Description for doors with MPG DSIU-iF171:
These doors consist of 2" double -skin Insulated sections with polyurethane
insulation foamed in place between both skins. Both inner and outer skins are min. 27
ga. (0,016") G40 DDS per ASTM A653. The maximum section height is 21". These
doors may have optional Impact -Resistant Glazing (Molded). Optional Impact-Reslstant
Glazing is a one-piece injection -molded front frame and glazing. The following models
are at least structurally equivalent to the tested door: HDP20, HDPF20, HDPL20, 7200,
7201, 7203, 8200, 8201, 8203, 9200, 9201, 9203. Not all models may be shown on a
given drawing.
Product-Descripklon
for doors
with
MPC DSIE-1F471:
These
doors consist of
It double -skin Insulated sections with
an EPS core
laminated to
both skins. Both
inner and outer skins are min. 27 ga.
(0.016") G40 DDS
PAGE 2 OF 3 FILE: CBPC 130214-A.4
EVALUATION REPORT FOR CLOPAY CORPORATION SECTIONAL GARAGE DOORS, W6 - W8
per ASTM A653. The maximum section height is 24". These doors may have optional
Impact -Resistant Glazing (Aluminum). Optional Impact -Resistant Glazing is an
aluminum front frame and a separate polycarbonate glazing. The following models are
at least structurally equivalent to the tested door: GD2SP, GR2SP, GD2LP, GULP,
AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, MFC68, 4305, HDGR, MFR68, 6205,
SFR68, Not all models may be shown on a given drawing.
Ihinact Resistant Glazing (�lumihum�;
The optional impact resistant glazing is an aluminum front frame and a separate
polycarbonate glazing that is an approved C1 plastic in accordance with testing
required by FBC-B 2606 and complies with FBC-B 2615 testing requirements. Approved
polycarbonate materials are Sabic IP Lexan 9034 (versions also approved: MR10, 9030,
90318, 90316, 90317, 90311, 90314, 90355) and Bayer Makrolon GP (versions also
approved: SL, AR, 15). Approval based on review of NOA 13-0717,01 (Sabic) and NOA
12-0605.05 (Bayer) and manufacturer's product datasheets.
Impact Resistant Glazing fMoldedl;
The optional impact resistant glazing is an injection -molded polycarbonate front
frame and glazing (LEXAN SLX2432T) that is an approved C1 plastic in accordance with
testing required by FBC-B 2606. FBC-B 2615 compliance based on review of the
following tests:
HETI-06-A002 ASTM G155; HETI-06-T566 ASTM D638 (before); HETI-06-T634 ASTM
D638 (after); ETC-06-1024-17496.0 ASTM D2843, ASTM D635, ASTM D1929,
Limitations_:
The drawings) cited above are an explicit part of this evaluation report. The
text of this report does not attempt to address all design details and relies on the
Illustrations and text of these drawings as well.
Jambs, lintels, sills or other structural elements required to prepare openings
are not covered. The design of the supporting structural elements shall be the
responsibility of the professional of record for the building or structure and in
accordance with current building codes for the loads listed on the drawing(s) referenced
above,
Installation requirements per the relevant Florida Administrative Rule, Including
attachments, are detailed on the drawing(s) listed above. Installation must be in
accordance with manufacturer's installation instructions and must be as shown on the
drawings) listed above. The manufacturer's licensed design professional listed on the
drawings) has reviewed the attachment details and installation requirements.
Signature;
Scott Hamilton, P. E.
Florida P. E. No. 63286
Date: WIZ /zv
STATE OF 4i:
0�� c� O R `O P N
d/ONA '0NC?��.
PAGE 3 or 3 FILE: CBPC_130214-A.4