HomeMy WebLinkAboutEnergy CodeFORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
FT. PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Nurnber of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.54
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
SHGC: SHGC=0.25
c. U-Factor. N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1327.80 ft2
b. Frame - Wood, Adjacent
R=11.0
352.00 ft2
1
c. N/A
R=
ft2
2
d. NIA
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1608.00 ft2
1608
b. WA
R=
ft2
Area
c. N/A
R=
ft2
11. Ducts
R ft2
97.44 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
41.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
13. Heating systems
a. Electric Heat Pump
4.073 ft.
0.250
Area
14. Hot water systems
1608.00 ft2
a. Electric
ft2
ft2
b. Conservation features
None
15. Credits
i certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ate: `k ``,p
Address of New Home: ��lj City/FL Zip�S�
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.95
CF, Pstat
O� v4E STAT6
�C
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of"11 ;,
r
FORM R405-2014
'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE MAJESTIC
Builder Name: WYNNE DEVELOPMENT
/
Street: CS v,tz)0 j
Permit Office: ST. LUICE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1679.8 sqft.)
Insulation Area
2. Single amily or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1327.80 ft2
b. Frame - Wood, Adjacent
R=11.0 352.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1608.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1608.00 ft2
6. Conditioned floor area above grade (ft2) 1608
b. N/A
R= ft2
Conditioned floor area below grade (W) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(138.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sal, U=0.54 97.44 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 41.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: WA ft2
SHGC:
13. Heating systems
kBtufnr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.073 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1608.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1608.00 ft2
b. Conservation features
EF: 0.950
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
CF, Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 50.56
PASS
Total Baseline Loads: 50.90
1 hereby certify that the plans and specifications covered by
Review of the plans and
-TO E S�,11�
this calculation are in compliance with the Florida Energy
specifications covered by this
O�
Code.
calculation indicates compliance
A?awith
the Florida Energy Code.
mnr'"� - ° '��''�"� ,� O
;;
PREPARE B
Before construction is completed
�
DATE:
this building will be inspected for
compliance with Section 553.908
LJ
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
WE
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
�t
FORM R405-2014
PROJECT
Title: THE MAJESTIC
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1608
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225
Street:
Permit Office: ST. LUICE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
' New/Existing: New (From Plans)
Comment:
CLIMATE
v
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
' 1 Entire House
1608 12864
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO
238 1904 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
589 4712 No
0
1
Yes
Yes
Yes
8 KITCHEN
228 1824 Yes
0
1
Yes
Yes
Yes
9 BATH 2
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
82 656 No
0
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 38 ft 0
238 ft2
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft2
____
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft2
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 It 0
36 ft2
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft 0
180 ft2
0 1
0
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft
0
589 ft2
0
1
0
8 Slab -On -Grade Edge Insulatio KITCHEN 12 ft
0
228 ft2
0
1
0
•
9 Slab -On -Grade Edge Insulatio BATH 2 5 It
0
50 ft2
___
0
1
0
10SIab-On-Grade Edge Insulatio HALL 1 ft
0
25 f12
0
1
0
11SIab-On-Grade Edge Insulatio FOYER 9 ft
0
82 ft2
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
!/
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1695 ft2
268 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
• V
# Type Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1608 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) MASTER BEDRO
30
Blown
238 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented) LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented) DINING/GREAT
30
Blown
589 1`1:2
0.1
Wood
8 Under Attic (Vented) KITCHEN
30
Blown
228 ft2
0.1
Wood
9 Under Attic (Vented) BATH 2
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented) HALL
30
Blown
25 111:2
0.1
Wood
11 Under Attic (Vented) FOYER
30
Blown
82ft2
0.1
Wood
WALLS
/
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Below
V it
Ornt 10 'Wail T ype Soave R-Value Ft In Ft
in
Area
R-Value Fraction
Absor.
Grade%
1
NE=>W Exterior Concrete Block - Ext InNASTER BE
4.1 17
0 9
5
160.1 ft2
0
0
0.6
0
2
SW=>E Exterior Concrete Block - Ext InddASTER BE
4.1 7
0 9
5
65.9 ft2
0
0
0.6
0
3
NW=>S Exterior Concrete Block - Ext InsMASTER BE
4.1 14
0 9
5
131.8 f1:2
0
0
0.6
0
4
NE=>W Exterior Concrete Block - Ext InddASTER BA
4.1 8
0 9
5
75.3 ft2
0
0
0.6
0
5
NE=>W Exterior Concrete Block - Ext InsuM. BATH
4.1 7
0 9
5
65.9 ft2
0
0
0.6
0
6
NE=>W Exterior Concrete Block - Ext InMDROOM 2
4.1 12
0 9
5
113.0 ft2
0
0
0.6
0
_ 7
SW=>E Exterior Concrete Block - Ext In-4NNING/GRE
4.1 30
0 9
5
282.5 ft2
0
0
0.6
0
I-8
NW=>S Exterior Concrete Block - Ext InDMING/GRE
4.1 20
0 9
5
188.3 ft2
0
0
0.6
0 I
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FOOM R405-2014
WALLS
Adjacent
Space
Cavity Width Height
Sheathing Framing Solar
Below
°
Ornt TO Ilzype
R-ynt6e Et In Ft
In Area
R--V-alue
Fract4on Ahsor Grad
9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN
4.1 12 0 9
5 113.0 ft2
0
0 0.6
0
10 NE=>W Exterior Concrete Block - Ext Insul BATH 2
4.1 5 0 9
5 47.1 ft2
0
0 0.6
0
11 SE=>N Exterior Concrete Block - Ext Insul FOYER
4.1 8 0 9
5 75.3 ft2
0
0 0.6
0
12 SW=>E Exterior Concrete Block - Ext Insul FOYER
4.1 1 0 9
5 9.4 ft2
0
0 0.6
0
_ 13 N=>SW Garage Frame - Wood WIC
11 44 8
352.0 ft2
0.23 0.6
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
None
.39 3
3
7 22.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V # Omt ID Frame Panes NFRC
U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1 NW=>S 3 Metal Low-E Single Yes
0.54 0.25
32.9 ft2 2 ft 0 in
1 It 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5 Metal Low-E Single Yes
0.54 0.25
6.9 ft2 2 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6 Metal Low-E Single Yes
0.54 0.25
16.4 ft2 2 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7 Metal Low-E Single Yes
0.54 0.25
41.3 ft2 2 It 0 in
1 ft 4 in
None
None
5 NW=>S 8 Metal Low-E Single Yes
0.55 0.25
41.0 ft2 9 ft 0 in
1 ft 4 in
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 880 ft2 880 ft2
44 ft
9 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1500.8 82.39 154.95 .2598
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
= COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit Split
SEER: 15 34.8 kBtu/hr
cfm
0.8 1
sys#1
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.95 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
V FSEG
Collector
Storage
Cert #
Company Name
System Model # Collector.Model # Area
Volume
FEF
None
None
ft2
DUCTS
— Supply —
— Return—
Air
CFM 25
CFM25
HVAC #
J #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
1
Attic 6 325 ft2
Attic
105 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programabl[e Y
Ceiling Fans:
]Thermostat:
Heating (X] Jan
[[ ]]
HFeb [Xj Mar
Apr
Apr
[Xj
MaM:yy r� Jun [ ]Jul
Aug
Sep
ri0cj
L
OctX
Nov
Nov
Dec
D cVenting
[[ ]] Jan
Feb [ki Mar
Jun [ ]Jul
Aug
Sep
lx
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78
78
78 78 78
78
78
80
80
80
80
PM 80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78
78
78 78 78
78
78
78
78
78
78
PM 78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66
66
66 66 68
68
68
68
68
68
68
PM 68
68
68
68 68 68
68
68
68
68
66
66
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE MAJESTIC Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUICE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
I CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of t,le foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rini joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, iC rated, and sealed to the drywa11.
Plumbing and wiring.
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
I I
gasketed doors I
I
8/25/2016 7:19 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1