Pro ect Summa D°be -�- wrightsoft � � Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 .Fax 772-466-6796 Email: QUl For: WYNNE DEV. THE MAJESTIC, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 18090 Btuh Ducts 5901 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 23991 Btuh Infiltration Method Construction quality Fireplaces Area (f:2) Volume (ft3) . Air changes/hour Equiv.AVF'(cfm) Simplified Average 0 Heating Cooling 1608 1608 15115 15115. 0.38 0.20 96 50 Heating Equipment Summary Make Carrier Trade CARRIER AIR'CONDITION ING Model 25HBC536A*030 AHRI ref 7914585 Efficiency .8.5 HSPF Heating input Heating output 34600 Btuh @ 47°F Temperature rise 27 . OF Actual air flow 1160 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Space thermostat Summer Design Conditions Outside db 90 OF. Inside db .75 OF Design TD 15 OF Daily.range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible. Cooling Equipment Load Sizing Structure 15679 Btuh Ducts 8918 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95. Equipment sensible load 23367 Btuh Latent Cooling Equipment Load Sizing Structure 2105 Btuh Ducts 2427. Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 4532 Btuh Equipment total load 27899 Btuh Req. total capacity at 0.70 SHR 2.8 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN((B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btu PF �. Actual air flow 1 80i '4 Air flow factor 0. ' cf Static pressure 0n 2©�' Load sensible heat ratio, 0. 4 Calculations approved.byACCA to meet all requirements of Manual J 8th Ed. " wrightsoft` Right -Suite® Universal 2017 17.0.03 RSU08101 2016-Aug-26 1Page I 9 k CalcslDocuments\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJB Front Door faces: N FF wrightsoft° Right-J® Worksheet °b Entire House Date: QUICK CALLS, INC. By: 317 ST.. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 -Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire. House MASTER BEDROOM 2 F�cised wall 141.0 ft 38.0 ft 3 Room height 9.4 ft d 9.4 ft heat/cool 4 Room dimensions 14.0 x 17.0 ft 5 Room area 1608.0 ftz 238.0 ft2 Ty Construction LI-value Or HTM Area (ftj Load Area number (Btuh/ft-'F) (Btuh/ftz) or perimeter (ft) (Btuh) . or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 1Ac1om 0'"143 1:270 ne . fie 4 Q0 35:56 2 5$ 7043 461 7 437 0 1751 247 1113 488 160 _ 160 640 ` 2 407 1Ac1om :` ,1270 ne 35 56 Z0:43 16 0 ,581 _ '". 1151 0 4 .' Q A13A4ocs 0.143 se 4.00 2.55 75 52 210 134 0' 0 0 0 1-1 11DO 73A flocs 4AS 2 0.390 0:.143 0 770 se swfi 10.92 4 U0, 21 56 11.31 2 55 27 53 23 470 41 .23 429 22 248 1716 "893 257 1091 11 0 66 0 66 0 ' 263 0 167 13A4ocs 0.143 nw 4.00 2.55 320 246 985. 626 132 9 -G 1Ac1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 -G 4A5-2omd 0.770 nw 21.66 36.90 41 0 880. 1505 0 vg4226 16A-30md 0.032 0.90 2 32 1608 1608 1441 3731 238 23 01989 27,69 000 16p8 , 141 3905. 238 :3 vs _ _ 11621 14781 6 c)AED e»ursion 1666 636 Envelope loss/gain 15144 14848 3727 3492 12 a) Infiltration 2946 831 794 224 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to,13) 18090 15679 4521 3716 Less odemal load 0 0 0 0 Less transfer 0 0 0 6 Redistribution 0 0 0 0 14 Subtotal 18090 15679 4521 3716 151 Duct loads 33% 570/a 5901 .8918 33% 57%1 1475 .2114 Total room load 23991 24597 - 1 5996 .2901 5830 Air required (cfm) 1160 1160 275 .A} Wrightsoft� Right -Suite® Universal 2017 17.0.03 RSU08101 k Caics\Documents\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N 2016-Aug-26 10:19:23 Page 1 I + wrIgMsoft: Right-@ Worksheet Job: Entire Hoe Date:. . . . QUICK CALCS, INC.' By: 317 ST LUCIE.I.N., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCSL&AOL.COM I Room name WIC :MASTER BATH 2 ..Bq)osed will 0 ft 8.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heat/c6d 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 7.0. x 8.0 ft 66.0 ftz Ty Construction number 1.1-value (Btuhfft *F) Or HTM (BtUWft2) Area (ft2) or perimeter (ft) Load (EBRt h) Area ' (ft2) or perimeter (ft) Load (Btuh) Heat cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 `. 13A�ocs A 0.143 ne : 4 00' 2 55 0 0A 6 0 `76 0. 0011- v; ;3;A �A -,'6 f56- 0 o -0 I IL13A400S 0.143 se 4.00 2.55 0 0 0 0 0 0- 0 0 —0 111130. 0.390 se 10.92 11.131. 0 0 0 0 SW!, �0 '0 b —0 .0 s 0 0 13A-4ccs; 1A-clom -4A5-2omd-, 0.143 1.270 nw nw .4.00, 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 c 16A30md 0.032 0.90 Z32 .63 63 56 146 56 . 56 -50 130 OR 21.N 060 :,0 I Yn R j, 6 cjAED e')cursion- -4 -9 Envelope loss/gain 56 143 573 312 12 a) Infiltration 0 0 167 47 b) Room ventilation 0 0 0 .0 1 1 3 Internal cons: Occupants @ .230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 143 740 359 Less external load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 143 740 359 15 Duct loads 33% 57% 18 81 33%1 57% 241 204 Total room load 75 224 981 W Air required (cfm) 41 11 47 27 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .444- wrlsoitboft- Right -Suite® Universal 2017 17.0.03 RSU08101 2016-Aug-26 10:19:23 ... k CalcskDocuments\WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N Page 2 vvriljhtsdft1.� R�WhW@ Worksheet Job: Entire House Date: By: QUICK CALC.S, INC. • 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM I Room name M. BATH LAUDRY 2 3 - =ed wall . height 7.0 ft 41 9.4 ft heat/cool 0 ft 9.4 ft . heat/cool 4 5 Room dimensions Room area 1.0 x 61.0 ft 61.0 ft2 . 6.0 x 6.0 ft 36.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area 01:2) Load number (Btuh/ft2L.-F) (BtUWft2) or perimeter (ft) (13tuh) or perimeter (ft) (13tuh) Heat I C.1 Gross I N/P/S Heat I Cool Gross I WPIS Heat I Cool 6 0143 Q`,:n 55 �66 160 0 No 4270 _76-43 �7 -0 247 488 0, "�j 27d 'ne, 10 43 -A 0 Y--LD 13A4ocs: 6.143 se 4.66 2.55 0 0 0 0 0 0 0 0 11 11DO OMO se 10.92 11.31 0 0 0 0 0 0 0 0 ji z 20b770 21,5fi 13A4ocs 0.143 nW 4.00 2.55 0 0 0 0 0. .0 0 0 1A,c1om .1*270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0770 nw 21.56 36.90 0 0 0 0 0 0 0 0 "vo --.146f 'A "o C 16Ar30Md 0.032 0.90 2.32 61 61 55 142 36 36 32 84 0. 86 - 7 A.64 "W w V, 4" wa d �r '-3 6 c)AED excursion -20 -2 I Envelope loss/gain 731 759 32 81 12 a) Infiltration 146 41 0 0 b) Room ventilation 0 0 6 0 13 Internal gains: Occupants@ 230 0 0 01 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 877 801 32. 81 Less external load .0 0 0 .0. Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 877 801 32 81 15, Duct loads 33%, 57%. 286, 455 33% 57% 11 46 Total room load 1163 1256 1 43 128 Air required (cfm) 56 59 21 61 Calculations approved byACCAto meet all requirements of Manual J-8th.Ed. Id wrightscoft. . 2016 .-Aug-26 10:19:23 Aftk Rig.ht-suite@) Uni.veirsal 2017 17.0;03 RSU08101 Page 3 ... kCaleskDocuments%WYNNE-MAJESTICMODr:L-1608.rup Calc=MJ8 Front Door faces: N lghtsiiife 0 Job: wr Right-J@ W rksheet Entire Hodse Date: QUICK CALCS, INC. By: 317 ST. LUCIE-LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-W96 Email: QUICKCALCS@AOL.COM I Room name BEDROOM 2 DINING/ . GREAT.ROOM .2 E)pwed wall 12.0 ft . 50.0 ft 3 Room height I 9.4 ft heat/cool 9.4 ft . heat/cool 4 Room dimensions 15.0 x 12.0 ft 1.0 x 589.0 5 Room area 180.0 ft2 589.0 ft2 - Ty Construction 1.1-value Or HTM Area (ft2) Load Area (ft2) Load number (Stuh/ft'L*F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -1,0143 00 5,t, 404,43 113, 1�40 `386 :�246;� z-, 0 0 �-270 `56 0. I LO 13A-4ocs 0.143 se 4 2.55 0 0 0 0 0 0 0 D 19 11100 0.390 se s, 16.'92 11.31 0 0 0 0 0 0 '94 0 0 AIN W r I3A-40cs U,714�1 nw 4.VU Z' on U U U V Im 14f _11tw ---G 1A-clorn 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 --G 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 .41 0 880 :-122,," 122•`-- 16k40md 0.032 0.90 2:32 180 180 161 418 589 589 528 . 0-1,999 1", 'A6 -A. pn A" W. —4. w tz v; -A 1 01 121 a)* Infiltration 251 71 10451. . 295 b) Room ventilation 0 0 .0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2023 1991 6282 6365 Less e)demal load 0 .0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2023 1991 6282 6365 .is Duct loads 33% 57% 660 1133 330/ol 57% 1 2049 3621 FTotal room'load [Air 2683 3124 1 1. 8331 9986 required (cfm) .130 147 . 403 471 Calculations approved by ACCA to meet all requirements of Manual J - 8th Ed. 4-id-' Wr igilliltst),ft• 2016-Aug-26 .10:19:23 Right -Suite® Universal 2017 17.0.03 RSU08101 Page 4 k Calcs%Docurrients%WYNNE-MAJESTIC MODEL-1608.nip Calo = MJ8 Front Door faces: N AL Job: at rF, wrightsoft Right-.JO Worksheet De: EntireHouseQUICK . CALCS, . INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-46"799 Fax 772-46"796 Email:- QUICKCALCS@AOL.COM 1 Room name KITCHEN BATH 2 2 =ed wall 12.0 ft 5.0 ft 3 height 9.4 ft heat/cool 9.4 ft heat/cool 4 5 Room dimensions Room area 19.0 x 12.0 ft 228.0 ft2 . 10.0 x 5.0 ft 50.0 ft2 Ty Construction number U-value (Btuhtft7-*F) Or HTM (Btuwft2) Area (ft2) or perimeter (ft) (13tuhLoad ) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool j Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 a-, I LO yJ I flocs 1A bM 13A4ocs 11D0. 13A4ocs IA-clom 4A5-2omd &14 io .270 6.143 0.390 0.143 1.270 0.770 n6 . . .ne.0 se se 5� nw nw nw 4M . . . . . . . . 4.00 10.92 .4.00 35.56 21.56 I 4335.56, 2.55 11.31 2.65 45.24 36.90 , 0 0 0 0 0 0 0 0 0 113 0 0 0 0. 01 0 0 0 0 0 0 .0 0 0 0 8M.- 6 0 0 '47; 0 0 0 0 0 0. 0 0 0 0 0 .0 0 0 0 Z! 0 0 0 0 0 .,1 22: -122 �157' C- 16A-30md 0.0ki 0.90 2.32 228 228 204 529 50 50 45 116 p A IT'.4, Q 00 2 A. 34 a k A "R K, 6 c)AED emursion -26 -7 Envelope loss/gain 1300 947 371,1 229 12 a) Infiltration . 251 71 .104 29 b) Room ventilation 0 0 .0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 1 15M 1018 476 259 Less eAemal load 0 .0 0 0. Less *transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1550 1018 476 259 15 Duct loads 33% 57% 506 579 33% 57% 155 147 Total room load 2056. 1597 631 406 Air required (cfm) 991 751 F 31, 19 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ewwrighti;o ft*' 2016-Aug-26 16:19:23 A& Right -Suite® Universal 2017 17.0.03 RSU08101 Page 5 ... k Caics%Docunients%WYNNE-MAJESTIC MODEL-1608.rup Calc = MJ8 Front Door faces: N wrig6tsoift' Right-.1®'Worksheet Job: Date: Endre House QUICK CALCS, INC. By: • 317 ST LUCIE LN., FT . PIERCE, FL 34946 Phone: 772466-6769 Fax 772-466-6796 Email:' QUICKCALCS@,AOL.COM I Room name HALL FOYER 2 ExIme d wall 0 It 9.0 ft 3 Room height 9.4 ft heat/cool 9.4 ft heaVcool 4 5 Room dimensions Room area 5.0 x 5.0 ft 25.0 ft2 1.0 x 820 ft 82.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft-) Load number (BtuIVftt-*F) (BtuWft2) or perimeter (ft) (13tuh) or perimeter (ft) (Btuh) Heat Coal Gross N/P/S Heat cool Gross N/PIS Heat Cool 6 IA� �,A:270 0. 1.2 rg . I - ... 10M .0:: -0: 0` - . -1 A :�o j- , :� _0_ 11 Y—Z 13AAocs 11DO '4odg - 0.143 0*.390 0,143 se se nw 4.00 10.92 11 4.00 2.65 11.31 27.-53 2.55 0 0 :0 ,. 0 0 0'A ..0 0 0 :0 0 0 0 0 01 75 23 , _-§ 0 52 23 �, -11. 0 210 . .. 248 0 134 257 0 Y13A-flocs —G 1A-c1orn 12701 nw 35.56 45.241 0 01 01 0 01 0 0 0 -.0 C 16A30md 0.032 0.90 Z32 25 25 22 58 82 82 73 190 4 p -25 A :O .�O 9 " E "r"i J: 41 J U_ 61 c) AED excursion -1 -22 Envelope loss/gain 22 57 1322 836 1.2 a), Infiltration 0 0 188 53 b) Room ventilation 0 0 .0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Olnes 6 to 13) 22 57 1510 . 889 Less external load 0 0 0 0 -Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 22 57 1510 889 15 Duct loads 331/6 57%. 7 32 33% 492 .506 FT6tal T -room load 30 89 21502 1394 Air required (cfm) '1 4 . 971 W Calculations Right -Suite@ Universal 2017 17.0.03 RSU08101 ... kCalcs%Docurrients%VvYNNE-MAJESTICMODEL-1608.rup Calc=MJ8 Front Door faces: N J 8th Ed. 2016-Aug46 16:19:23 Page 6