Loading...
HomeMy WebLinkAboutAPPROVED Windload Docs - Linda Grant - 6706 Salerno RoadCertified By Florida Licensed Professional Engineer or Architect EL16107 R14 Equiv 20200812 - FBC - ASTM 1886-1996eaiLpdf Sections from the Code Product Approval Method Method 1 Option D Date Submitted 02/16/2021 Date Validated 02/16/2021 Date Pending FBC Approval 02/22/2021 Date Approved 04/13/2021 Summary of Products Go to Page � 0 0 0 Page 2/ 3 4 0 FL # Model, Number or Name Description 16107,21 21 W8-16 DSIE-IF471: GD2SP, Double -skin Insulated EPS (exterior skin 27 ga. min,; Interior GR2SP, GD2LP, GR2LP, AR2SP, skin 27 ga. min.) Double -Car (9'2" to 16'2" wide) WINDCODE0 AR2LP, ED2SP, ED2LP, 4302, HDGL, W8 Garage Door with Optional Impact -Resistant Lites 6202, MFC68, 4305, HDGR, 6205, SFR68, MFR68 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R14 II 104786-Rev06.pd Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party; No Design Pressure. +46 PSF/-52 PSF Evaluation Reports Other: Max, Wind Speed (V_ult): 170 MPH, Solid doors or FL16107 R14 AE CBPC 130214-A.pdf doors with optional impact -resistant glazing are Impact- Created by Independent Third Party: No resistant (large missile Impact), 16107.22 22 W6-09 DSIE-1F171: 4400, 4401, Double -skin Insulated EPS (exterior skin 27 ga, min,; Interior 4301, 4300, 4301, 4310, HDG, skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W6 HDGL, HDGF, 66, 66G, 67, 67G, 68, Garage Door with Optional Impact -Resistant Lites SP200, SF200, SE200, 6200, 6201, 6203 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R14 11 101526-A-Rev22,W Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PF 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure. +38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R14 AE CBPC 130214-A,p�f doors with optional Impact -resistant glazing are Impact- Created by Independent Third Party: No resistant (large missile Impact). 16107.23 23 W6-09 DSIE-IF171: 4400, 4401, Double -skin Insulated EPS (exterior skin 27 ga, min.; interior 4300, 4301, 4310, HDG, HDGL, skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODEO W6 HDGF, 66, 66G, 67, 67G, 68, SP200, Garage Door SF200, SE200, 6200, 6201, 6203 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R14 II 101526-B-Rev22.pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load EL16107 R14 AE CBPC 130214-A,pdd requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.24 24 W6-09 PAN-2F153: 84A, 94, 73, Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide) 75, 1500, 190, 4RST, 4RSF, 4F, WINDCODE(& W6 Garage Door with Optional Impact -Resistant 6RST, 6RSF, 48, 42, 55, 48B, 42B, Lites 55S, GD5S, GDSSV, GR5S, GRSSV, AR5S, AR5SV, EDSS, EDSSV Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R14 II 101348 ev ILdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other. Max, Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R14 AE CBPC 130214-A.pdf doors with optional Impact -resistant glazing are Impact- Created by Independent Third Party: No resistant (large missile Impact). 16107,25 25 W6-09 PAN-2F153: 84A, 94, 73, Steel Pan (min. 25 ga,) Single -Car (up to 9'0" wide) 75, 1500, 1901 4RST, 4RSF, 4F, WINDCODEW W6 Garage Door 6RST, 6RSF, 481 42, 55, 48B, 42B, 55S, GD5S, GDSSV,. GR5S, GRSSV, ARSS, AR5SV, ED5S, ED5SV Limits of Use Installation Instructions Approved for use In HVHZ: No FL16107 R14 II 101348-B-Rev19.pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R14 AE CBPC 130214-A.pdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windborne debris regions, 16107,26 26 W6-09 PAN-2F156: 76, 76V, 2RST I Steel Pan (min, 25 ga.) Single -Car (up to 9'0" wide) WINDCODEO W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R14 II 101348-A-Rev19 pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R14 AE CBPC 130214-A.pdf doors with optional Impact -resistant glazing are impact- Created by Independent Third Party: No resistant (large missile Impact). 16107.27 27 W6-09 PAN-2F156: 76, 76V, 2RST Steel Pan (min. 25 ga,) Single -Car (up to 9'0" wide) WINDCODE® W6 Garage Door Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R14 II 101348-B-Rev19 pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet tthy..wind-I 107 BP&-130 4- .p_df requirements of the building co a-bnt-'DO NOT meet the Impact Created by Independent Third Party: No - resistant requiremenVorWEnchorne debris regions. 16107. 28 W6-09 DSIE-SA171: 2050, 2051, Double -skin Insulated EPS(exterior skin 27 ga, 2053, 4050, 4051, 4053, 62, 64, 65, skin 29 9a. min.) Single -Car (up to 9'0" wide)' 62G, 62LG, 64G, SDP38, SFL38, Garage Door SRP381 134, 135, 136, 6130, 6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16107 R14 II 104814-A-Rev01 p� �yproved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 I&Ip4ct Resistant: Yes Created by Independent Third Party: No Design ssure: +36 PSF/-44 PSF Evaluation Reports Other: Max, indpeed (V_ult): 170 MPH. Solid doors are FL16107 R14 AE CBPC 130423-A.pdf Impact -resistant (larg`e hitssil Impact). Created by Independent Third Party: No W6 16107.29 29 W6-09 DSIE-1A171: 2050, 20 , ou a-s m nsu a e EPS(exterior skin 27 ga. min.; Interior 2053, 4050, 4051, 4053, 62, 64, 65, skinmin,) Single -Car (up to 9'0"wide) WINDCODE® W6 62G, 62LG, 64G, SDP381 SFL38, Garage Door SRP38, 134, 135, 136, 6130, 6131, 6133 Limits of Use Installation Instructions Approved for use in HVHZ: No FL16107 R14 II 104814-e-Rev0l. pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 Impact Resistant: No Created by Independent Third Party: No Design Pressure: +36 PSF/-44 PSF Evaluation Reports Other: Doors with standard glazing meet the wind load FL16107 R14 AE CBPC 130423-A.pdf requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No resistant requirement for windborne debris regions. 16107.30 30 W6-09 DSIE-1F471; GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED25P, ED2LP, 4302, HDGC, 6202, MFC68, 4305, HDGR, 6205, SFR68, MFR68 Double -skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODEp W6 Garage Door with Optional Impact -Resistant Lltes Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL36107 R14 II 103954-A-Rev06.pdf Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286 impact Resistant: Yes Created by Independent Third Party: No Design Pressure: +38 PSF/-44 PSF Evaluation Reports Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or FL16107 R14 AE CBPC 130423-A pdf doors with optional impact -resistant glazing are impact- Created by Independent Third Party: No resistant (large missile Impact). 16107.31 131 W6-09 DStE-1F471: GD2SP, � Double -skin Insulated EPS (exterior skin 27 9a. min.; Interior d / I - §� s y �\ A\ ! !!\;4: ; ,l,Gn::, , April 23, 2013 (Revised 2/12/21) Evaluation Report for Clopay Corporation Sectional Garage Doors, W6 through W8 I have evaluated the wind load door designs as shown on the drawings listed below. I have reviewed the test reports, which were generated by accredited laboratories as required by the relevant Florida Administrative Rule, the engineering rational analysis, and the product drawings. The test reports are listed below. Assembly testing was conducted by American Test Lab North Carolina. Component testing was conducted by HETI and ETC. For the doors listed in Tables 1 through 5, Static Pressure Tests were conducted in accordance with TAS 202-1994, ASTM-E330-2002 and ANSI/DASMA 108-2005. Missile Impact and Cyclic Pressure Tests were conducted in accordance with TAS 201-1994 and TAS 203-1994 and ASTM E1886-2005 and ASTM E1996-2009 and ANSI/DASMA 115-2005. The pressures listed on the drawings are either direct results of these tests or results obtained through engineering rational analysis based on actual tests. I have concluded that the door designs listed below in Tables 1 through 5 are in compliance with these High Velocity Hurricane Zone test requirements of the Florida Building Code and therefore are qualified as impact -resistant assemblies (large missile impact). 103954-A-Rev06, max. door size 9'0" x 16'0"; +36/-44 PSF (design I 104119-Rev059 max. door size 9'0" x 16'0"; +54/-60 PSF (design 1 TABLE 2• Drawinas for doors with Manufacturina Product Code (MPC) DSIE-1A171: 104814-A-Rev05, max. door size 9'0" x 16'0"; +36/-44 PSF (design load) 103488-A-Rev10, max. door size 9'0" x 16'0"; +38/-44 PSF (design load) 104790-A-Rev10, max. door size 16'2" x 16'0"; +38/-42 P5F (design load) 103488-A-Rev09, 104790-A-Rev09, max. max. door door size 9'0" x 16'0'; size 16'2" x 16'0"; +38/-44 +38/-42 PSF PSF (design (design load) load) TABLE 5• Drawings 104790-A-RevO9, for max. doors door with Manufacturina size 16'2" x 16'0"; Product Code +38/-42 (MPC) PSF SPO-2F449: (design load) For the doors in Tables 6 through 10, Static Pressure Tests were conducted in accordance with ASTM-E330-2002 and ANSI/DASMA 108-2005. The pressures listed on the drawings are either direct results of these tests or results obtained through engineering rational analysis based on actual tests. I have concluded that the door designs listed below in Tables 6 through 10 are in compliance with these test requirements of the Florida Building Code, TABLE 6• Drawinas for doors with Manufacturina Product Code (MPC) DSIE-iF471: 103954-B-Rev06, max. door size 9'0" x 16'0";PSF (design load) Pnce 1 of 3 Fire; CBPC_130423-A.7 EVALUATION REPORT FOR CLOPAY CORPORATION SECTIONAL GARAGE DOORS, TABLE 7• Drawinas for doors with Manufacturina Product Code (MPC) DSIE-1F471: 104814-B-RevO5, max. door size 9'0" x 16'0"; +36/-44 PSF (design load) 488-B-Rev09, max. door size 9'0" x 16''0 +38/-44 PSF (design load) 790-B-RevO9, max, door size 16'2" x 16"; +38/-42 PSF (design load) 103488-B-Rev10, 104790-B-Rev10, max. door size max. door size 9'0" x 1 '0"; 1612" x 16'0"; +38/-44 P5F +38/-42 PSF (design (design load) load) TABLE 30 Drawings 104790-B-Rev09, for doors with max. door size Manufacturina 16'2" x 16'0"; Product Code (MPC) SPO-2F449: +38/-42 PSF (design load) Test Reports: ATL-0115.01-13R (3/18/13), ATL-0117.01-13 (3/18/13), ATL-0102.01-13 (2/20/13), ATL-0304.01-13 (5/1/13), ATL-0308.01-13 (5/l/13), ATL-0213.01-13 (4/29/13), ATL-0326,01-13 (5/1/13). These reports document compliance with the TAS testing standards and are signed and sealed by David Johnson, FL PE 61915. Product Description for doors with MPC DSIE-SF471: These doors consist of 2" double -skin Insulated sections with an EPS core laminated to both skins. Both inner and outer skins are min. 27 ga. (0.016") G40 per ASTM A653. The maximum section height is 24". These doors may have optional Impact -Resistant Glazing (Aluminum). Optional Impact -Resistant Glazing is an aluminum front frame and a separate polycarbonate glazing. The following models are at least structurally equivalent to the tested door: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED21.13, 4302, HDGC, 6202, MFC68, 4305, HDGR, MFR68, 6205, SFR68. Not all models may be shown on a given drawing. Product Description for doors with MPC DSIE-1A171: These doors consist of 1-3/8" double -skin insulated sections with an EPS core laminated to both skins. Outer skin is min. 27 ga. (0,016") and inner skin is min. 29 ga. (0,012) G40 per ASTM A653. The maximum section height is 21". The following models are at least structurally equivalent to the tested door: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 64G, 65G, DP38, F1.38, RP38, 134, 135, 136, 6130, 6131, 6133, Not all models may be shown on a given drawing. Product Description for doors with MPC PAN-2F443: These doors consist of 2" thick steel pan doors with min. 24 ga. (0.022") outer skins. The steel skin is at least G40 per ASTM A653. The maximum section height is 24". The sections may have EPS foam insulation inserted into the pan cavity. These doors may have optional Impact -Resistant Glazing (Aluminum). Optional Impact - Resistant Glazing is an aluminum front frame and a separate polycarbonate glazing. The following models are at least structurally equivalent to the tested door: G4S, GS4, GD4S, GR4S, G4SV, GS4V, GD4SV, GR4SV, E4S, ED4S, E4SV, ED4SV, MR4S, SS4, AR4S, MR4SV, SS4V, AR4SV. Not all models may be shown on a given drawing. Product Description for doors with MPC PAN-2F446: These doors consist of 2" thick steel pan doors with min. 24 ga. (0.022") outer skins. The steel skin is at least G40 per ASTM A653. The maximum section height is PAGE 2 OF 3 FILE: CBPC_130423-A.7 EVALUATION REPORT FOR CLOPAY CORPORATION SECTIONAL GARAGE DOORS, W6 - W8 24". The sections may have EPS foam insulation inserted into the pan cavity. These doors may have optional Impact -Resistant Glazing (Aluminum). Optional Impact - Resistant Glazing Is an aluminum front frame and a separate polycarbonate glazing. The following models are at least structurally equivalent to the tested door: G4L, GL4, 3D4L, GR4L, G4LV, GL4V, GD4LV, GR4LV, E4L, ED4L, E4LV, ED4LV, MR4L, SL4, AR4L, MR4LV, SL4V, AR4LV, BD4E, BD4EV, BR4E, BR4EV, PR4E, PR4EV, RR4E, RR4EV, BD4N, BD4NV, BR4N, BR4NV, PR4N, PR4NV, RR4N1 RR4NV. Not all models may be shown on a given drawing. Product Description for doors with MPC SPO-2F449: These doors consist of 2" thick steel pan doors with min. 24 ga. (0,022") outer skins. The steel skin is at least G40 per ASTM A653. The maximum section height is 24". The sections may have decorative overlays. The following models are at least structurally equivalent to the tested door: GHnn, GHRnn, GHRvnn, SPnn, SPVnn, SMnn where "nn" represents the configuration of the overlays. Not all models may be shown on a given drawing. Impact Resistant Glazino (Aluminum): The optional impact resistant glazing is an aluminum front frame and a separate polycarbonate glazing that is an approved C1 plastic in accordance with testing required by FBC-B 2606 and complies with FBC-B 2615 testing requirements. Approved polycarbonate materials are Sabic IP Lexan 9034 (versions also approved: MR10, 9030, 90318, 90316, 90317, 90311, 90314, 90355) and Bayer Makrolon GP (versions also approved: SL, AR, 15). Approval based on review of NOA 13-0717,01 (Sabic) and NOA 12-0605.05 (Bayer) and manufacturer's product datasheets. Limitations: The drawings) cited above are an explicit part of this evaluation report. The text of this report does not attempt to address all design details and relies on the illustrations and text of these drawings as well. Jambs, lintels, sills or other structural elements required to prepare openings are not covered. The design of the supporting structural elements shall be the responsibility of the professional of record for the building or structure and in accordance with current building codes for the loads listed on the drawing(s) referenced above. Installation requirements per the relevant Florida Administrative Rule, including attachments, are detailed on the drawing(s) listed above. Installation must be in accordance with manufacturer's installation instructions and must be as shown on the drawing(s) listed above. The manufacturer's licensed design professional listed on the drawing(s) has reviewed the attachment details and installation requirements. Signatur}e: ,�-(rHAM��� iiz� Scot HC�iIIIItOt1`DigitallysignedbyScottHamiltonJgC:��GENSF.000 0 Date: 2021.02.1619:39:22-05'00' No 63286 4110 Old Scott Hamilton, P. E. Florida P. E. No. 63286 This document has been digitally signed and is valid without a physical Is; Third -party verification of the PDF can attest that the document has not been changed since it was signed. The printed document is just a copy and cannot be verified. �0'.STATE OF <[/ O. �tCs''#6 O R I �.P`,G'��,� PAGE 3 OF 3 FILE: CBPC_130423-A.7