HomeMy WebLinkAboutAPPROVED Windload Docs - Linda Grant - 6706 Salerno RoadCertified By
Florida Licensed Professional Engineer or Architect
EL16107 R14 Equiv 20200812 - FBC - ASTM 1886-1996eaiLpdf
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02/16/2021
Date Validated 02/16/2021
Date Pending FBC Approval 02/22/2021
Date Approved 04/13/2021
Summary of Products
Go to Page � 0 0 0 Page 2/ 3 4 0
FL #
Model, Number or Name
Description
16107,21
21 W8-16 DSIE-IF471: GD2SP,
Double -skin Insulated EPS (exterior skin 27 ga. min,; Interior
GR2SP, GD2LP, GR2LP, AR2SP,
skin 27 ga. min.) Double -Car (9'2" to 16'2" wide) WINDCODE0
AR2LP, ED2SP, ED2LP, 4302, HDGL,
W8 Garage Door with Optional Impact -Resistant Lites
6202, MFC68, 4305, HDGR, 6205,
SFR68, MFR68
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R14 II 104786-Rev06.pd
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party; No
Design Pressure. +46 PSF/-52 PSF
Evaluation Reports
Other: Max, Wind Speed (V_ult): 170 MPH, Solid doors or
FL16107 R14 AE CBPC 130214-A.pdf
doors with optional impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact),
16107.22
22 W6-09 DSIE-1F171: 4400, 4401,
Double -skin Insulated EPS (exterior skin 27 ga, min,; Interior
4301, 4300, 4301, 4310, HDG,
skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODE® W6
HDGL, HDGF, 66, 66G, 67, 67G, 68,
Garage Door with Optional Impact -Resistant Lites
SP200, SF200, SE200, 6200, 6201,
6203
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R14 11 101526-A-Rev22,W
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PF 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure. +38 PSF/-44 PSF
Evaluation Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 R14 AE CBPC 130214-A,p�f
doors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107.23
23 W6-09 DSIE-IF171: 4400, 4401,
Double -skin Insulated EPS (exterior skin 27 ga, min.; interior
4300, 4301, 4310, HDG, HDGL,
skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODEO W6
HDGF, 66, 66G, 67, 67G, 68, SP200,
Garage Door
SF200, SE200, 6200, 6201, 6203
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16107 R14 II 101526-B-Rev22.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other: Doors with standard glazing meet the wind load
EL16107 R14 AE CBPC 130214-A,pdd
requirements of the building code but DO NOT meet the Impact
Created by Independent Third Party: No
resistant requirement for windborne debris regions.
16107.24
24 W6-09 PAN-2F153: 84A, 94, 73,
Steel Pan (min. 25 ga.) Single -Car (up to 9'0" wide)
75, 1500, 190, 4RST, 4RSF, 4F,
WINDCODE(& W6 Garage Door with Optional Impact -Resistant
6RST, 6RSF, 48, 42, 55, 48B, 42B,
Lites
55S, GD5S, GDSSV, GR5S, GRSSV,
AR5S, AR5SV, EDSS, EDSSV
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R14 II 101348 ev ILdf
Approved for use outside HVHZ: Yes
Verified By: Scott Hamilton FL PE 63286
Impact Resistant: Yes
Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation Reports
Other. Max, Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 R14 AE CBPC 130214-A.pdf
doors with optional Impact -resistant glazing are Impact-
Created by Independent Third Party: No
resistant (large missile Impact).
16107,25 25 W6-09 PAN-2F153: 84A, 94, 73, Steel Pan (min. 25 ga,) Single -Car (up to 9'0" wide)
75, 1500, 1901 4RST, 4RSF, 4F, WINDCODEW W6 Garage Door
6RST, 6RSF, 481 42, 55, 48B, 42B,
55S, GD5S, GDSSV,. GR5S, GRSSV,
ARSS, AR5SV, ED5S, ED5SV
Limits of Use Installation Instructions
Approved for use In HVHZ: No FL16107 R14 II 101348-B-Rev19.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R14 AE CBPC 130214-A.pdf
requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No
resistant requirement for windborne debris regions,
16107,26
26 W6-09
PAN-2F156:
76,
76V, 2RST
I Steel Pan (min, 25 ga.) Single -Car
(up to
9'0" wide)
WINDCODEO W6 Garage Door
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16107 R14 II 101348-A-Rev19 pdf
Approved for use outside HVHZ: Yes
Verified By:
Scott Hamilton FL
PE 63286
Impact Resistant: Yes
Created by
Independent Third
Party: No
Design Pressure: +36 PSF/-44 PSF
Evaluation
Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 R14
AE CBPC 130214-A.pdf
doors with optional Impact -resistant glazing are impact-
Created by
Independent Third
Party: No
resistant (large missile Impact).
16107.27 27 W6-09 PAN-2F156: 76, 76V, 2RST Steel Pan (min. 25 ga,) Single -Car (up to 9'0" wide)
WINDCODE® W6 Garage Door
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R14 II 101348-B-Rev19 pdf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +38 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet tthy..wind-I 107 BP&-130 4- .p_df
requirements of the building co a-bnt-'DO NOT meet the Impact Created by Independent Third Party: No -
resistant requiremenVorWEnchorne debris regions.
16107. 28 W6-09 DSIE-SA171: 2050, 2051, Double -skin Insulated EPS(exterior skin 27 ga,
2053, 4050, 4051, 4053, 62, 64, 65, skin 29 9a. min.) Single -Car (up to 9'0" wide)'
62G, 62LG, 64G, SDP38, SFL38, Garage Door
SRP381 134, 135, 136, 6130, 6131,
6133
Limits of Use
Installation Instructions
Approved for use
in HVHZ: Yes
FL16107 R14
II 104814-A-Rev01 p�
�yproved for use
outside HVHZ: Yes
Verified By:
Scott Hamilton FL
PE 63286
I&Ip4ct Resistant:
Yes
Created by
Independent Third
Party: No
Design ssure:
+36 PSF/-44 PSF
Evaluation
Reports
Other: Max, indpeed (V_ult): 170 MPH. Solid doors are
FL16107 R14
AE CBPC 130423-A.pdf
Impact -resistant (larg`e
hitssil Impact).
Created by
Independent Third
Party: No
W6
16107.29 29 W6-09 DSIE-1A171: 2050, 20 , ou a-s m nsu a e EPS(exterior skin 27 ga. min.; Interior
2053, 4050, 4051, 4053, 62, 64, 65, skinmin,) Single -Car (up to 9'0"wide) WINDCODE® W6
62G, 62LG, 64G, SDP381 SFL38, Garage Door
SRP38, 134, 135, 136, 6130, 6131,
6133
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL16107 R14 II 104814-e-Rev0l. pdf
Approved for use outside HVHZ: Yes Verified By: Scott Hamilton FL PE 63286
Impact Resistant: No Created by Independent Third Party: No
Design Pressure: +36 PSF/-44 PSF Evaluation Reports
Other: Doors with standard glazing meet the wind load FL16107 R14 AE CBPC 130423-A.pdf
requirements of the building code but DO NOT meet the Impact Created by Independent Third Party: No
resistant requirement for windborne debris regions.
16107.30 30 W6-09 DSIE-1F471; GD2SP,
GR2SP, GD2LP, GR2LP, AR2SP,
AR2LP, ED25P, ED2LP, 4302, HDGC,
6202, MFC68, 4305, HDGR, 6205,
SFR68, MFR68
Double -skin Insulated EPS (exterior skin 27 ga. min.; interior
skin 27 ga. min.) Single -Car (up to 9'0" wide) WINDCODEp W6
Garage Door with Optional Impact -Resistant Lltes
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL36107 R14
II 103954-A-Rev06.pdf
Approved for use outside HVHZ: Yes
Verified By:
Scott Hamilton FL
PE 63286
impact Resistant: Yes
Created by
Independent Third
Party: No
Design Pressure: +38 PSF/-44 PSF
Evaluation
Reports
Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or
FL16107 R14
AE CBPC 130423-A pdf
doors with optional impact -resistant glazing are impact-
Created by
Independent Third
Party: No
resistant (large missile Impact).
16107.31 131 W6-09 DStE-1F471: GD2SP, � Double -skin Insulated EPS (exterior skin 27 9a. min.; Interior
d
/ I
-
§�
s y
�\ A\
!
!!\;4:
;
,l,Gn::,
,
April 23, 2013 (Revised 2/12/21)
Evaluation Report for Clopay Corporation Sectional Garage Doors, W6 through W8
I have evaluated the wind load door designs as shown on the drawings listed below. I
have reviewed the test reports, which were generated by accredited laboratories as
required by the relevant Florida Administrative Rule, the engineering rational analysis,
and the product drawings. The test reports are listed below. Assembly testing was
conducted by American Test Lab North Carolina. Component testing was conducted by
HETI and ETC.
For the doors listed in Tables 1 through 5, Static Pressure Tests were conducted in
accordance with TAS 202-1994, ASTM-E330-2002 and ANSI/DASMA 108-2005. Missile
Impact and Cyclic Pressure Tests were conducted in accordance with TAS 201-1994
and TAS 203-1994 and ASTM E1886-2005 and ASTM E1996-2009 and ANSI/DASMA
115-2005. The pressures listed on the drawings are either direct results of these tests
or results obtained through engineering rational analysis based on actual tests. I have
concluded that the door designs listed below in Tables 1 through 5 are in compliance
with these High Velocity Hurricane Zone test requirements of the Florida Building Code
and therefore are qualified as impact -resistant assemblies (large missile impact).
103954-A-Rev06, max. door size 9'0" x 16'0"; +36/-44 PSF (design I
104119-Rev059 max. door size 9'0" x 16'0"; +54/-60 PSF (design 1
TABLE 2• Drawinas for doors with Manufacturina Product Code (MPC) DSIE-1A171:
104814-A-Rev05, max. door size 9'0" x 16'0"; +36/-44 PSF (design load)
103488-A-Rev10,
max. door
size 9'0"
x 16'0";
+38/-44
PSF (design
load)
104790-A-Rev10,
max. door
size 16'2"
x 16'0";
+38/-42
P5F (design
load)
103488-A-Rev09,
104790-A-Rev09,
max.
max.
door
door
size 9'0" x 16'0';
size 16'2" x 16'0";
+38/-44
+38/-42
PSF
PSF
(design
(design
load)
load)
TABLE 5• Drawings
104790-A-RevO9,
for
max.
doors
door
with Manufacturina
size 16'2" x 16'0";
Product Code
+38/-42
(MPC)
PSF
SPO-2F449:
(design load)
For the doors in Tables 6 through 10, Static Pressure Tests were conducted in
accordance with ASTM-E330-2002 and ANSI/DASMA 108-2005. The pressures listed on
the drawings are either direct results of these tests or results obtained through
engineering rational analysis based on actual tests. I have concluded that the door
designs listed below in Tables 6 through 10 are in compliance with these test
requirements of the Florida Building Code,
TABLE 6• Drawinas for doors with Manufacturina Product Code (MPC) DSIE-iF471:
103954-B-Rev06, max. door size 9'0" x 16'0";PSF (design load)
Pnce 1 of 3 Fire; CBPC_130423-A.7
EVALUATION REPORT FOR CLOPAY CORPORATION SECTIONAL GARAGE DOORS,
TABLE 7• Drawinas for doors with Manufacturina Product Code (MPC) DSIE-1F471:
104814-B-RevO5, max. door size 9'0" x 16'0"; +36/-44 PSF (design load)
488-B-Rev09,
max. door size 9'0" x
16''0
+38/-44
PSF (design
load)
790-B-RevO9,
max, door size 16'2" x
16";
+38/-42
PSF (design
load)
103488-B-Rev10,
104790-B-Rev10,
max. door size
max. door size
9'0" x 1 '0";
1612" x 16'0";
+38/-44 P5F
+38/-42 PSF
(design
(design
load)
load)
TABLE 30 Drawings
104790-B-Rev09,
for doors with
max. door size
Manufacturina
16'2" x 16'0";
Product Code (MPC) SPO-2F449:
+38/-42 PSF (design load)
Test Reports:
ATL-0115.01-13R (3/18/13), ATL-0117.01-13 (3/18/13), ATL-0102.01-13 (2/20/13),
ATL-0304.01-13 (5/1/13), ATL-0308.01-13 (5/l/13), ATL-0213.01-13 (4/29/13),
ATL-0326,01-13 (5/1/13). These reports document compliance with the TAS testing
standards and are signed and sealed by David Johnson, FL PE 61915.
Product Description for doors with MPC DSIE-SF471:
These doors consist of 2" double -skin Insulated sections with an EPS core
laminated to both skins. Both inner and outer skins are min. 27 ga. (0.016") G40 per
ASTM A653. The maximum section height is 24". These doors may have optional
Impact -Resistant Glazing (Aluminum). Optional Impact -Resistant Glazing is an
aluminum front frame and a separate polycarbonate glazing. The following models are
at least structurally equivalent to the tested door: GD2SP, GR2SP, GD2LP, GR2LP,
AR2SP, AR2LP, ED2SP, ED21.13, 4302, HDGC, 6202, MFC68, 4305, HDGR, MFR68, 6205,
SFR68. Not all models may be shown on a given drawing.
Product Description for doors with MPC DSIE-1A171:
These doors consist of 1-3/8" double -skin insulated sections with an EPS core
laminated to both skins. Outer skin is min. 27 ga. (0,016") and inner skin is min.
29 ga. (0,012) G40 per ASTM A653. The maximum section height is 21". The following
models are at least structurally equivalent to the tested door: 2050, 2051, 2053, 4050,
4051, 4053, 62, 64, 65, 62G, 64G, 65G, DP38, F1.38, RP38, 134, 135, 136, 6130,
6131, 6133, Not all models may be shown on a given drawing.
Product Description for doors with MPC PAN-2F443:
These doors consist of 2" thick steel pan doors with min. 24 ga. (0.022") outer
skins. The steel skin is at least G40 per ASTM A653. The maximum section height is
24". The sections may have EPS foam insulation inserted into the pan cavity. These
doors may have optional Impact -Resistant Glazing (Aluminum). Optional Impact -
Resistant Glazing is an aluminum front frame and a separate polycarbonate glazing.
The following models are at least structurally equivalent to the tested door: G4S, GS4,
GD4S, GR4S, G4SV, GS4V, GD4SV, GR4SV, E4S, ED4S, E4SV, ED4SV, MR4S, SS4,
AR4S, MR4SV, SS4V, AR4SV. Not all models may be shown on a given drawing.
Product Description for doors with MPC PAN-2F446:
These doors consist of 2" thick steel pan doors with min. 24 ga. (0.022") outer
skins. The steel skin is at least G40 per ASTM A653. The maximum section height is
PAGE 2 OF 3 FILE: CBPC_130423-A.7
EVALUATION REPORT FOR CLOPAY CORPORATION SECTIONAL GARAGE DOORS, W6 - W8
24". The sections may have EPS foam insulation inserted into the pan cavity. These
doors may have optional Impact -Resistant Glazing (Aluminum). Optional Impact -
Resistant Glazing Is an aluminum front frame and a separate polycarbonate glazing.
The following models are at least structurally equivalent to the tested door: G4L, GL4,
3D4L, GR4L, G4LV, GL4V, GD4LV, GR4LV, E4L, ED4L, E4LV, ED4LV, MR4L, SL4, AR4L,
MR4LV, SL4V, AR4LV, BD4E, BD4EV, BR4E, BR4EV, PR4E, PR4EV, RR4E, RR4EV, BD4N,
BD4NV, BR4N, BR4NV, PR4N, PR4NV, RR4N1 RR4NV. Not all models may be shown on a
given drawing.
Product Description for doors with MPC SPO-2F449:
These doors consist of 2" thick steel pan doors with min. 24 ga. (0,022") outer
skins. The steel skin is at least G40 per ASTM A653. The maximum section height is
24". The sections may have decorative overlays. The following models are at least
structurally equivalent to the tested door: GHnn, GHRnn, GHRvnn, SPnn, SPVnn, SMnn
where "nn" represents the configuration of the overlays. Not all models may be shown
on a given drawing.
Impact Resistant Glazino (Aluminum):
The optional impact resistant glazing is an aluminum front frame and a separate
polycarbonate glazing that is an approved C1 plastic in accordance with testing
required by FBC-B 2606 and complies with FBC-B 2615 testing requirements. Approved
polycarbonate materials are Sabic IP Lexan 9034 (versions also approved: MR10, 9030,
90318, 90316, 90317, 90311, 90314, 90355) and Bayer Makrolon GP (versions also
approved: SL, AR, 15). Approval based on review of NOA 13-0717,01 (Sabic) and NOA
12-0605.05 (Bayer) and manufacturer's product datasheets.
Limitations:
The drawings) cited above are an explicit part of this evaluation report. The
text of this report does not attempt to address all design details and relies on the
illustrations and text of these drawings as well.
Jambs, lintels, sills or other structural elements required to prepare openings
are not covered. The design of the supporting structural elements shall be the
responsibility of the professional of record for the building or structure and in
accordance with current building codes for the loads listed on the drawing(s) referenced
above.
Installation requirements per the relevant Florida Administrative Rule, including
attachments, are detailed on the drawing(s) listed above. Installation must be in
accordance with manufacturer's installation instructions and must be as shown on the
drawing(s) listed above. The manufacturer's licensed design professional listed on the
drawing(s) has reviewed the attachment details and installation requirements.
Signatur}e: ,�-(rHAM��� iiz�
Scot HC�iIIIItOt1`DigitallysignedbyScottHamiltonJgC:��GENSF.000 0
Date: 2021.02.1619:39:22-05'00' No 63286 4110
Old
Scott Hamilton, P. E.
Florida P. E. No. 63286
This document has been digitally signed and is valid without a
physical Is; Third -party verification of the PDF can attest
that the document has not been changed since it was signed.
The printed document is just a copy and cannot be verified.
�0'.STATE OF
<[/
O. �tCs''#6 O R I �.P`,G'��,�
PAGE 3 OF 3
FILE: CBPC_130423-A.7