Loading...
HomeMy WebLinkAboutCompaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:213398-1d/JM/bm NUC #215 Nuc Model:MC-1DR-P Nuc Serial #:MD80404215 8124 Amalfi Circle Lot 27, Waterstone Ft Pierce, Florida Compacted Foundation Fill DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 N.W.0" - 12"13D 107.5 110.8 97.0% 2 N.E."12D 106.9 "96.5% 3 Center "14D 108.5 "97.9% 4 S.E."13D 107.1 "96.7% 5 S.W."14D 108.2 "97.7% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets 5/6/2021 Email to: rick.johnson@adamshomes.com PE # 81439 8.8% 12.0% Respectfully Submitted: Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. Proudly Serving Florida since 1990 Soil Description: ITEM TESTED: 110.8 TEST LOCATION OF SAMPLE SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 May 5, 2021DATE TESTED: PERMIT #: CONTRACTOR:Adams Homes 2103-0155 Bryan E. Dahlke, P.E. V.P. of Engineering Certified Women Owned Business - WBE Minimum Requirement for Staked Foundation JOB LOCATION: Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Brown Sand In Place Moisture: 105.0 106.0 107.0 108.0 109.0 110.0 111.0 112.0 7 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight