Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING Piorida Department of Busi -a -P-EIME i�al�R��egulation - Residential ECEIVEi� J CONSTRUCTION Peflormance Method Project Name: 5811 Balsam Dr AUG 14 2aig Bi iilder Name: Adams Homes of Northwest Florida. Inc. S 1 eet: 5811 Balsam Dr P rma office: St Lucie County City, State, Zip Fort Pierce, FL , 34982 5T, Lucie Count Permittin Permit Number. Y ' 9J Wrier: Adams Homes --- iisdiction: 611000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1477.8 sgft.) insulation Area a, Concrete Block - int Insu1, Exterior R=4.1 1312.50 fta 2.,Single family or multiple family Single-family b. Frame - Wood. Adjacent R=13.0 155.33 fe 3. Number of units, if multiple family I c, NiA R= ft2 4. Number of Bedrooms 4 d. NIA 10. Ceiling Types (182$,0 sgft.) R= fill insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 1760.00 ft' 6. Conditioned floor area above grade (fill) 1760 b. Knee Wall (Vented) R=19.0 68.00 ft' c. NIA R= ftl Conditioned floor area below grade (ft') 0 11. Ducts R It" 7. Windows(211.9 sgft.) Description Area a. Sup: Attic, Ret: Main, AH: Main 6 300 a. U-Factor. Dbl, U=0.34 110.46 fF SHGC: SHGC=0.31 Cooling systems kBtuAir Efficiency b. U-Factor: Qbl, U=G.33 64.15 It' a. Cenhal Unit a, 35.0 SEER:15.00 SHGC: SHGC=0.28 c. U-Factor: Dbl, U= 0.34 32.38 ft' SHGC. SHGC=0.23 13. Heating systems kBtulhr Efficiency d U-Factor, other (see details) 4,92 fi' a. Electric Heat Pump 34.6 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth- 4.448 ft. Area Weighted Average SHGC: 0.288 14. Hot water systems a. Electric Cap:40 gallons 8. Floor Types (1760.0 sgft.) Insulation Area EF: 0.920 a. Slab -On -Grade Edge Insulation R=0.0 1760.00 fP b. Conservation features b. NIA R= fe None c. NIA R= ft' 15. Credits Pstat Total Proposed Modified Loads: 56.71 PA �± Glass/Floor Area: 0.120 Total Baseline Loads: 58.60 �7 I hereby certify that the plans and specifications covered by Review of the plans and Tktf _P4,�, this calculation are in compliance with the Florida Energy specifications covered by this zkp' Code. calculation indicates compliance � A with the Florida Energy Code. PREPARED BY. Before construction is completed DATE: ,vL - r�l. l _.., __.,. _ this building will be inspected for compliance with Section 553.90E ¢ *sr , I hereby certify that this building, as designed, is in compliance Florida Statutes. CDU 6b'E with the Florida Energy de. OWNER/AGENT. _ BUILDING OFFICIAL DATE. DATE.- - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies.gs'�� certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4 .1 1&ar is project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402,4.1.2). It000 7/21I2019 2:49 PM EnergyGauge4D USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 �.. ­r nA4 7 Dint IT ct tMMAPV rWIzrKI IAT REPORT t-VMIVI r[VVJ-CV 1 r Sims v . V....... r. — �— — — -- -- - - PROJECT Title: 5811 Balsam Dr Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1760 Lot # Owner Name: Adams Homes Total Stories. 1 Block/Subdivision• # of Units: 1 Worst Case: No PlatBook: Builder Name. Adams Homes of Northwest FI Rotate Angle. 0 Street: 5811 Balsam Df Permit Office: St Lucie County Cross Ventilation' County: St. Lucie Jurisdiction: 611000 Whole House Fan. City. State, Zip. Fort Pierce , Family Type: Single-family FL , 34982 New/Exisfing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp �l Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH-!MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blocki 1760 14080 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1760 14080 Yes 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 182.8 ft 0 1760 ft' -- 0 0 t ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor Tested Tested Insul. (deg) 1 Gable or shed Composition shingles 1968 ft' 440 ft' Medium N 085 No 0.9 No 0 26.6 ATTIC V f # Type Ventilation Vent Ratio (t in) Area RIBS IRCC 1 Full attic Vented 300 1760 fP N N CEILING V # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ t Under Attic (Vented) Main 30 Blown 1760 ft' 0,11 Wood 2 Knee Wall (Vented) Main 19 Blown 68 it' 0.11 Wood 7/212019 2:49 PM EnergyGaugeO USA 6.0.02 (Rev 1) - FfaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 fwfnf I Of taanAAOV rucrLofl ICT Mll=OnRT t-UKIVI 114UD-LU 1 /- WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below �f # Omt To Space Wall Type R-Value Ft In Ft . In _ Area A:Value Fraction Absor_ _.Grade°!o 1 SE Exterior Concrete Block • Int Insul Main 4.1 25 1 8 200.7 ft 0 0.6 0 _ •_ 2 SE Exterior Concrete Block - Int Insul Main 4.1 8 11 10 89.2 ft' 0 0.6 0 3 SE Garage Frame - Wood Main 13 20 8 8 165.3 ft' 0.16 0.75 0 4 SW Exterior Concrete Block - Int Insul Main 4.1 36 8 8 293.3 ft' 0 0.6 0 ° 5 NW Exterior Concrete Block - Int Insul Main 4.1 41 2 8 329.3 ft' 0 0.6 0 6 NE Exterior Concrete Block - Int Insul Main 4.1 36 4 8 290.7 fF 0 0.6 0 7 NW Exterior Concrete Block - Int Insul Main 4.1 13 8 8 109.3 f? 0 0.600000 0 ' DOORS # Ornt Door Type Space Storms U-Value Ft Width Width In Ft Area ° 1 SE Wood Main None 21 2 8 6 8 17.8 ft' 2 SE Insulated Main None .21 3 6 8 20 ft' WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang I # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 .Vinyl Low-E Double Yes 0.33 0.28 N 46.4 ft' 1 ft 4 in 1 ft 0 in None None _ 2 SE 2 Vinyl Low-E Double Yes 0 31 0.29 N 4.9 ft' 9 It 4 in 1 ft 0 in None None 3 SW 4 Vinyl Low-E Double Yes 0.34 0.31 N 16.2 ft' 1 ft 4 in 1 ft 0 in None None _ 4 NW 5 Vinyl Low-E Double Yes 0.34 0.31 N 80.9 fl' 1 ft 4 in 1 ft 0 in None None 5 NW 7 Vinyl Low-E Double Yes 0.33 028 N 17 8 It' 11 ft 7 in t ft 0 in None None 6 SE 2 Vinyl Low-E Double Yes 0.34 0.31 N 13.3 ft' 9 ft 4 in 3 ft 0 in None None 7 NW 7 Vinyl Low-E Double Yes 0,34 0.23 N 32.4 ft' 11 it 7 in 1 ft 0 in Drapes/blinds Exterior 5 GARAGE t # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 427.232 ft' 427.232 fP 62 ft 8 It 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 I Wholehouse Proposed ACH(50) 000254 1173.3 64.41 121.14 .0881 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtuthr 1 sys#1 V21/2019 2:49 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 MIMI IT ZI tneAawoV 1-ucr-V1 ICT RFDCIRT 1-UKM K4U7-LV I I nor v vv.�......,.. — — — COOLING SYSTEM V . # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Uniti None SEER. 15 35 kBhVhr 1050 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 4 1 Electric None Garage 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM V/ FSEC Collector Storage Geri # Company Name System Model # Collector Model # Area Volume FEF None None ft� DUCTS _- Supply — - Return --. Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 300 ft' Main 88 ft, Default Leakage Main (Delauft) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans. Cooling [ ll Jan Feb Feb Mar Xj Mar ( Apr May (X] Jun X Jul ( Apr May [ ] Jun j Jul X Au Aug Sep ri Se (j Oct [ j Oct [ j Nov [X] Nov ( Dec [X Dec Heating 4X] Jan Jan Feb [[X Mar [X Apr l May [ } Jun JUI t l Aug t Sep [X] Oct [X) Nov [ Dec Venting jjjjj 1 Thermostat Schedule: HERS 2006 Reference Hours 12 Schedule Type 1 2 3 4 5 6 7 8 9 10 1 1 Cooling (VVD) PM 80 8 78 78 78 80 78 78 78 78 78 78 78 78 so 78 80 78 80 78 80 78 Cooing (WEH) AM PM 76 78 78 78 78 78 78 78 78 78 78 78 78 78 78 6 78 78 Heating (WO) AM PM 68 66 66 66 66 68 68 68 68 68 68 8 66 68 68 68 68 68 66 68 66 68 66 Heating (WEH) PM 68 68 68 68 68 68 68 68 68 68 68 66 68 66 MASS Mass Type Area Thickness Fumiture Fraction Space Default(8 lbsis .ft. 0 ft;1 0 ft 0.3 Main 7/21/2019 2:49 PM EnergyGauge4l) USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DiSPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* : 97 The lower the Energy; Performance Index, the more efficient the home: 1. New home or, addition 1. New (Front Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Bindle -family b) Return ducts R­ 6,0 c) AHU location Main 3. No, of units (if multiple -family) 3 1. 4. Number of bedrooms 4, 4 13. Cooling system: Capacity_ 35.0 a) Split system SEER 5. is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP� 6. Conditioned floor area (sq, ft.) 6. V 1760 d) Room unit/PTAC EER e) Other .15.0 7. Windows, type and area a) U-factor:(weighied average) 7a. 0.336 bj Solar Heat Gain Coefficient (SHGC), 7b. 0.288__ e) Area 7e.� 21�1.9 8. Skylights a) U-factor:(weighted average) b) Solar Heat Gain Coefficient (SHGC) 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (insulation R-value) 2. Masonry (insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed Sa. NA 8b. NA 9b. 9c. 10A1.- 10A2. 4.1 10B1 13.0 10B2. 11a. 30.0 _ 11 b. 11c. 19.0 11 d. No 14, Heating system. Capacity 34.6F a) Split system heat pump HSP b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE� fi Other 8.50 15. Water heating system a) Electric resistance EF 0,92 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 16, HVAC credits claimed (Performance Method) a) Ceiling farts b) Cross ventilation _ _ No c) Whole house fan No d) Multizone.cooling credit e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with 'the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or, exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature:�E��- - Date. 7 / City/FL Address of New Home: 5811 Balsam Dr Zip. Fort -Pierce, FL 34982 i 7/21/2019 2:49:26 PM EnergyGauge44 USA 6.0.02 (Rev. 1) - FtaRes2017 FBC 6th Edition (2017) Compriant Software Page 1 of i Envelope Leakage Test Report (Blower Door Test) • Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction. 611000 Permit #: Builder: Adams Homes of Northwest Fldi Watrtcwity Lot. NA Address: 5811 Balsam Dr City Fort Pierce State: FL Zip: 34982 x 60 r 14080 = CFM(50) Building Volume ACH(50) FIPASS El When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Method for calculating building volume: 0 Retrieved from architectural plans . Code software calculated O Field measured and calculated R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSURESNETIICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statues or individuals licensed as set forth in Section 489 105(3)(0, (g). or (I) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3 Interior doors, if installed at the time of the test, shall be open 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if Installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open Company Name. Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Printed Name of Tester: License/Certification #: Date of Test: Issuing Authority: 7121/2019 2:49:40 PM EnergyGauge® USA 6.0,02 (Rev. 1) - FlaRes2017 FOC 6th Edition (2017) Compliant Software Page 1 of 1