Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
i RECEIVED }. wrightsoft Project Summary Date- July 21, 2019 Entire House AUG 1 � 2019 By. Adams Homes ST. Lucie County, Permitting I 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 For: 5811 Balsam Dr, Adams Homes 5811 Balsam Dr, Fort Pierce, FI Notes: A/C Contractor Richard Hunt - Air Conditioning Unlimited Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 °F Design TD 15 °F Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17700 Btuh Ducts 6198 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification Piping Equipment load Infiltration Method Construction quality Fireplaces 0 Btuh 0 Btuh 23898 Btuh Simplified Average 0 Heating Cooling Area (ft2) 1762 1762 Volume (fP) 17903 17903 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 113 60 Heating Equipment Summary Make Carrier Trade CARRIER Model 25HBC537AO030 AHRI ref 10487322 Efficiency 8.5 HSPF Heating input Heating output 34600 Btuh @ 47°F Temperature rise 27 °F Actual air flow 1167 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Space thermostat Capacitybalance point = 33 °F Backup: Input = 7 kW, Output = 23954 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 16315 Btuh Ducts 9354 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 1707 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 26007 Btuh Latent Cooling Equipment Load Sizing Structure 3493 Btuh Ducts 2546 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 6039 Btuh Equipment Total Load (Sen+Lat) 32046 Btuh Req. total capacity at 0.75 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER Cond 25HBC537AO030 Coil FX4DNF037L AHRI ref 10487322 Efficiency 12.5 EER, 15.5 SEER Sensible cooling 26250 Btuh Latent cooling 8750 Btuh Total cooling 35000 Btuh Actual air flow 1167 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0 in H20. nA Load sensible heat ratio 0.82`` F`V Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -1"k VW1r19ft ¢=per« 2019-Jul-21 15:15:27 w .• m-- .•�« Right -Suite® Universal 2019 19.0.08'RSU06570 Page 1 I&K ...ransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE 1 wrightsoft, Right-M Worksheet Job: Entire House Date: July 21, zols By: Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 1 Room name Entire House bedrm 2 2 Exposed wall 161.0 ft 25.0 ft 3 Room height 10.2 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 164.0 ft 5 Room area 1762.0 ft2 164.0 ft' Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) I Load number (Btuh/ft2-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W _ 12B4Osw .. . ne._... 2.72 , 2.58 96 _._ . . _ 13A-4ocs _ _ _0.097 0.143 , ne 1 4.00 _. 2.55 _ ._ .•_ 272 _ ..,.. __96 183 _ ._ ._L261. 733 __. _ ..248:0: 466 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 7 0 92 198 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 47 0 616 1324 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 14 0 184 396 0 0 0 0 '�=D 11POe_._ .. -.-_0.290...ne_ -._..,8.12- 8.41.. ._.__.?1 _. _21 - _j7_t -.._. __177 _.0 _._. - 0.143 se. 0 2.55 286 ..... 276 7 1089 t93 0 0 0 .. 4A5-2ov_,._. 0.470 -se. 13.t6', 22:79 - ___209, .. 362 __ _ _ _ _0 ._-.. _ _. 0 _ _ _ _.0 ._:0 0.143 sw 4.00 2.55 614 483 1936 1231 104 88 353 224 10D-v 0.490 sw 13.72 9.84 19 19 264 190 0 0 0 0 V13A-4ocs 4A5-2ov 0.470 sw 13.16 22.79 80 30 1046 1812 16 6 209 362 4A5-2ov, _.... ... --.0.47Q sw _13.16.. 13.55. . -32 _- _ _32 __..-. -_4.18 431. -, -0 _ 0 __ _._0, 0- W .. 13A;4ocs___. ..._ __.-0.1,43 .nw - :.4:00. _-..2.55 .288: .. 288 1153 _733. 96_._ _...96 _ _ 384 _-----:244 ,C - _, 1613_30ad., _. , ._ 0.032 - ,-. - 0,90- 1.68 1762 __ 1762 _ .-, 1579.. -, 2960. _ _ , _ „164 -_ - 164 147. 276, F 22A-tpl _ _ _ _ ., 0.989. _ .- . _ . 27.69 ,t _ . _ 0.00.::.., _1762 '_ . _. 161 _..... 4458 , . _ _ _ 0 _ _ _ _ -164 .. -- . e 25 ' _ _ . _ 692 . , _ 61 c) AED excursion 1 9611 1 1 1 147 Envelope loss/gain 1 14211 12181 1 1 1786 1254 12 a) Infiltration 3489 984 448 126 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 1 230 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17700 16315 2234 1610 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 93 48 14 Subtotal 17700 16315 2326 1658 15 Duct loads 35% 57% 6198 9354 35% 57% 815 950 m load 28I 21691 31 2619Airrequ ir (c m) I 1167 167 I I 53 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrAg/wtq�tf 2019-Jul-2115:15:27 Right -Suite® Universal 2019 19.0.08 RSU06570 Page 1 ransfer\Manual J15811 Balsam Dr Adams Homes.rup Cale = MJ8 Front Door faces: NE -�- Wrightsoft° Right-M Worksheet Job: Entire House Date: July z,, zo,s Adams Homes By: 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 1 Room name c2 h bath 2 Exposed wall 2.0 It 6.0 ft Room height 8.0 ft heat1cool 8.0 ft heaticool 4 5 Room dimensions Room area 1.0 x 18.0 ft 18.0 ft' 10.0 x 6.0 ft 60.0 ft' Ty Construction U-value Or HTM Area (ft') Load I Area (ft') I Load I number (Btuh/ft2- (Btuh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 12B Osw 13A-40cs _ _=._0.097 0.143 . ne _ ne .. ,2 72. 4.00 ._ ._2.58 2.55 _ 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 -_�- 11P0._ - ----0.290 _,pe - -8.12. _8.41, _ _0 _ _. 0 ., .,_. _. 0 Vy - 13A-4ocs 0.143 .se 4.00 2.55 . 0 o. 0 0 0 0 0 0 L-� 4A526v_, _ _ _ _ .0.470 _,se_. _ _; 13.16: :22:79. _ , _.._ _0 , -._ 0 -_ --- _'_0 _..._ ._.. -0 .__ _ __ -_0 - -._ , ._0 _ _.'_ .. .0. _ - -.. 0 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10D-v 0.490 sw 13.72 9.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 0 0 0 0 4A5-2ov „- ._ ,- 0.470 ..sw 13.16. 0 0 0 0. 0 0 W_ .__ 13A,4ocs_.. __._. , _ __0.143 "nW -, -_...4.00_ ,-1155 _ _,2Z5 : _ _ .._16 ., _ -_____..16 _0 --. 41. _ _ .__.48 _. _0 _ __- 48 -_-, .-_ .-_- 192 122 C .F. . - , 1613-30ad 22A-tpl' ,._ 0.032, 0.969 r. .0.90 ...i 27:69 1.68 _ 6.00 18 . ._ .18 _ _ -18. ._ .._...•. _.2 - .. _. _16 .... _ ,55 - 30 _ . _ _ _ 0 _ -_ 60 . , _,._ _60 - -_ 60 .. _ 6 _ - 54 , _._ 166- - _ _ 101 .. _ . _0 6 c) AED excursion -3 -8 Envelope loss/gain 136 68 412 215 12 a) Infiltration 36 10 107 30 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 171 78 520 245 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -171 -78 176 92 14 Subtotal 0 0 696 337 15 Duct loads 35% 57% 0 0 35% 57% 244 193 room load Air 946 401 524I requi ed (c m) I 0 0 I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -rig- wvrrNg9�t��att�" 2019-Jul-21 15:15:27 ^� ^^ Right -Suite® Universal 2019 19.0.08 RSU06570 Paget ransfer\Manual A5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE _Pb_ wwreghtsloft` Right-J® Worksheet Job: Entire House Date: July 21, 2019 Adams Homes By: 751se Part St Lucie Blvd., Port St Lucie, FI 34984 1 Room name c3 1 2 Exposed wall 2.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 8.0 x 2.0 It 2.0 x 2.0 ft 5 Room area 16.0 ft' 4.0 ft' Ty Construction U-value Or HTM Area (ft') I Load Area (ft') Load number (Btuh/ft'-'F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 12BOsw.___ 0.097 , ne 272," .` -2.58 _0 ._.__':'0 _0 _ __0 _ __ .0 _.___._ _0 .:._ _0. 13A-flocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 4A5-2ov 0,470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 -ne_ ._.. _.8.12 8.41 0 �. 0 0_ W 13A-40cs 0.143 se 4.00` 2.55 0 0 0 - 0 - ... _0 0 _ . _..0 0 -- - 0 ___ __..__0. 0 4A5;2ov, _,-0.470 _se- . ,13.16 _-22.79 _ 0 0 _... __'._ 0 _,-._.__0 __1__.__0 _ ------ ._0 ..__,.___.0 Vh13A-4ocs 0. sw 4.. 0 0 0 0 0 0 0 0 10D-v 0.490 490 sw 13.72 72 9.8484 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 0 0 0 0 4A5-2ov _ _ -_- . -0.470 - sw, _ , 13.16_ 1.3.55 _- . . 0 0 W _ .._ 13A-4ocs- - ._ _ 0.143 .:nw:.._ ._4:00: _ c .2.55 _ _ „ ... _ :. 16 '- _. 16 ._ 41.. __... _ _ C,. ,,. 16t3-30ad._. 0.032 .. - .,„.0.90 _. .1.68. 16 76 _._14 ._. _?? ._._...._4 ..,.._ .4 7 F '..., °22A,tpl ... 0.989 4. _ -°, : ., 27.69. ' .-.. 0.00. ' . _ , 16 2 .._. ... _- ..55 _..- = 0 _, :4 : _, . _ .. ' 0 _..__.. _4 0. _. 0. 61 c) AED excursion 1-21 10 Envelope loss/gain 134 65 4 7 12 a) Infiltration 36 10 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 170 75 4 7 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -170 -75 -4 -7 14 Subtotal 0 0 0 0 15 Duct loads 35% 57% 0 0 35% 57% 0 0 Total room load OI 0 O O Air required (cfm) 0 0 I 0 I 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jul-2115:15:27 -r •""' Right -Suite® Universal 2019 19.0.08 RSU06570 Page ransferlManual J15811 Balsam or Adams Homes.rup Calc = MJ8 Front Door faces: NE - !- wrightsoft* Right-M Worksheet Job: Entire House Date: July 27, zo,s Adams Homes By: 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 1 Room name bedrm 3 a/h 2 Exposed wall 24.0 ft 0 ft Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 13.0 x 11.0 ft 3.0 x 3.0 ft 5 Room area 143.0 ft' 9.0 ft' Ty Construction U-value Or HTM Area (ft') I Load I Area (ft') Load number (Btuh/f?-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yV ._' 12B,6sw' -'ne'- . , .72' .2.58 _ _ 0 _0 _ __ _0 _ __ 0 0 _ . _0 - _ 0 _ . 0 13A-4ocs 0.143 ne 4.00 2.55 104 81 323 205 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 23 0 308 662 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 - 11P0_. - - - 0.290 _ne- ---,.8.12. 8.41 _, 0 --.... _. _ 0• 0, _0 . Vy 13A 4ocs 0.143 se " _se_ 4.00. �.93.16 _ '2.55 :. , 22.79 0 0 0 , - -,_ 0 0 .. __ _0 0 . 0.-_-0 0 0 _. ___._0 -- 0 _ ._ ___0' 0 __. __0' 13A-4ocs 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10D-v 0.490 sw 13.72 9.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 0 0 0 0 . .. 4A5-2ov.. _ 0.470 _. sw.. 13.16, .. 13.55 0 0. .. 0 _0 0. W . _.. 13A,cs. 4o.. 0.1 _ . _ 43. . nw _ _, 4.00 2.55 .._ 88 _. _ 88 . _ : : 352 •--_' _.224. .-- _ _-- 0 . _0 _� _ _ _ 0 C - 16B-30ad_- _,-- 0.032 - _ .. - 0.90- 1_.68 - _ .143 143 - 128. .. _ ,.240 _9 _ 8 15 F _ _.:.. 22A,tpl ..... _ _ -. _ _ _. _ _ ._0.989 _ 9 _ ..',27.69 ,.:D.00 _.._ ,,. _ 143 .. 24 _ _ ._ _665 - ... _ . _..0 . _ 9 .. __ _ -0 _ . _ - _. 0. .. _ . 0 - , 61 c) AED excursion 1 -541 0 Envelope loss/gain 1 1776 1277 1 1 8 15 12 a) Infiltration 430 121 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 2206 1629 8 15 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 90 48 -8 -15 14 Subtotal 2296 1676 0 0 15 Duct loads 35% 57% 804 961 35% 57% 0 0 al room load31511 2620 Air requi d (c m) I 1 I 0 O Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. -1°}#^ wr7�fl�sC4at�k' 2019-Jul-21 15:15:27 •� Rig ht-Suite® Universal 2019 19.0.08 RSU 0 6570 Page 4 ransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE AIL wrightsoft° Right-M Worksheet Job: Entire House Date: July 21, 2019 By: Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 1 Room name c4 bedrm 4 2 Exposed wall 0 ft 17.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 1.0 x 16.5 ft 1.0 x 152.0 ft 5 Room area 16.5 ft' 152.0 ft' Ty Construction U-value Or HTM I Area (ft') Load Area (ft') Load number (Btuh/ft'-°F (BtuNW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W _ , , 128-Osw- _ _. _ _ 0.097 .-ne _ _ 2.72 _ 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 104 81 323 205 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 23 0 308 662 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 w !. -..0 11P0 _ _. 13A 4ocs. 4A52ov ..:_ 0290 0 143 ..___.0.470 •ne_ se .se.` 812 '4 00 ? 13:16' 8.41. 2.55 d .22.79 0 0 ..._ _... _ 0 0 A .. A __ 0 0 _ _ _ _0 0 0 -_.___._ 0 _ 0 32 -0 _.. 0 32 ._ _ 0 0 128 y . _._ _0. 0 81 0.143 sw 4.00 2.55 0 0 0 0 0 0 0 0 10D-v 0.490 sw 13.72 9.84 0 0 0 0 0 0 0 0 N13A-4ocs 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 0 0 0 0 4A5-29(_0.470, -sw , 13AS, . - - 13.55 ... .. __ 0 ._ 0 _ , . ._ 0. . 0 W.. . _ 'j3A-4.oa___':._0_ 143 ..nw _ .-. 4.0.0- _ =2.55 .,. • : -0 .._,'.. _ 0 .:. 0 - 0 - _0 .-. _D C 16_B-30ad, _ _ 0.032 0.90 , 1.68 - _,. _ . 17 17 _ _ 15 . -.- _ _ 28 1.52 , -- 152 -_ -, 136 .. 255 F :.... - 22A;tpl,. __ . .._ ___._0.989 _ o _'27.69. . _._.0.00 17 _ r-_ ._:0 0 - _. . __0. _ ___152 __. ... 17 _'._.471. _ _ . _..0 61 c) AED excursion -1 -49 Envelope loss/gain 15 27 1366 1155 12 a) Infiltration 0 0 305 86 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 15 27 1670 1471 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -15 -27 150 79 14 Subtotal 0 0 1821 1550 15 Duct loads 35% 57% 0 0 35% 57% 638 889 2120I 2 Airre quroomi d (cfm) I 0 0 I 111 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. iF wirlaaaPfi" 2019-Jul-2115:15:27 •� Right -Suite® Universal 2019 19.0.08 RSU06570 Page 5 ransferWanual J15811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE J. " " wrighisof° Right-J® Worksheet Entire House Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 Job: Date: July 21, 2019 By: Calculations atioroved by ACCA to meet all requirements of Manual J 8th Ed. _0- w :t90w aFfi" 2019Jul-21 15:15:27 Right -Suite@) Universal 2019 19.0.08 RSU06570 Page 6 ransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE wrightsof° Right-J® Worksheet Job: Entire House Date Adams Homes By: 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 July 21, 2019 1 Room name great rm h 2 Exposed wall 17.0 ft 0 ft .; Room height 14.0 ft heaUcool 8.0 ft heat/cool 4 Room dimensions 1.0 x 338.5 ft 3.0 x 8.0 ft 5 Room area 338.5 ft' 24.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (Btuh/ft'-°F (Btuh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 _W,,... _ :12B Osw_-,." . _ _0.097 ..ne-, a__272; _ _ 2♦58 _._ _0 ._. 0 :_,_-...._ 0:.._. 0 -_ __- -0 -- - ., L0- _ ._._ .-0 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 Vy 11P0, r 13A 4oc"s - 4A52ov_ 0290_ne_. 0.143 0.470 se _ se - .,. 8.12 4:00; - 13.16, ,-.8.41,._ 2.55 �'. 22;79, _0 0 ._ .__0 _0......_-._ Ok _ . 0 0_..._;._ 0 _.. _. 0 0 0 _ - _ 0 ..__.-_ 0 0 _. _0 � 0 . _ ._ _. _0 ....... .0 . 0 t _ _ __ _ 0- 0 0 13A-4ocs 0.143 sw 4.00 2.55 238 187 748 476 0 0 0 0 10D-v 0.490 sw 13.72 9.84 19 19 264 190 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 0 0 0 0 W, 4A5 2ov - 13A4ocs:. ._.. 0.470, 0.143: . , sw- nw, 13.16 4.0Q 13.55 , _ 2.55 32 _.:0 32 _. 0 418 0 431 _-. 0. 0 _,. D--__ 0 ._ ___0 0 -..- -0 0 ..__ 0 C , F,:--... 16B-30ad _ 22A•tpl ; 0.032 _0.489 _ n,. _ 0.90 _ ,27:69 . _ - 1.68. ... ; 0.00 , 339. •_ ,.- 339 __339 .. ;:, .>17 303. _- ... . 471 569 _ ..., 0 ,. - „ - 24 .. ._'. ,._ 24 _-, _ _- 24 ,..,.._ . _. 0 _ ..._ 22 0. 40. 0. 61 c) AED excursion 1 578 -1 Envelope loss/gain 2205 2243 22 39 12 a) Infiltration 533 150 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2738 2393 22 39 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 518 767 -22 -39 14 Subtotal 3256 3160 0 0 15 Duct loads 35% 57% 1140 1812 35% 57% 0 0 Total room load 4316 4972 0 0 Air required (cfm) 215 226 1 1 0I 0 Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. _rfo" we 140 'ga p ^ 2019Jul-21 15:15:27 - Right -Suite® Universal201919.0.08RSU06570 Page7 "AMransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE J. wrightsoft, Right-M Worksheet Job: Entire House Date: July 21, 2019 By: Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 1 Room name dining kitchen 2 Exposed wall 12.0 ft 0 It 3 Room height 14.0 ft heat/cool 14.0 ft heat/cool 4 Room dimensions 1.0 x 152.0 ft 1.0 x 144.0 ft 5 Room area 152.0 ft' 144.0 ft' Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 W ._ - 12B4Osw- . _ . , . _ _ 13A-40cs _ _ _-nea 0.143 ne 2.72. 4.00 . u 2;58 2.55 . ,_.: .._ 0 0 , 0 0 0 0 0 0 0 4A5-20v 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 7777D, V)I 11P0,..._.. , _ 13A 4ocs ._.. _0.290..ne. 0.143 se 8.12- 4.00 - _8.41.. 2.55 0 0 _. 0 0 . _.,__ 0...,_. - 0 , 0. 0 ._.. __..0.,_,,. 0 .. .0 ; ' . 0 .... _..0 0 w_0 0, 4A5-2ov .:. _ , ..__. _ . .. _ _ 0.470 ,se. , _..13.16 '_ .22.79. _.. ,_ 0 , _.. .10 .'_ _ ._0 _ _s„__. 0 ...:._. 0 _ .. _ . _0 0, 13A-4ocs 0.143 sw 4.00 2.55 168 136 545 347 0 0 0 0 10D-v 0.490 sw 13.72 9.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 32 12 418 725 0 0 0 0 W 4A5-2ov - _ , _. 13A-4ocs.. ,= ...,... 0,470- 0:143 sw- riw _ „13.16,, 4.00 13.55 .2:55 - 0 :.____ _ 0 _ 0 . _ 0 0 . - 0 ,.__- .0. ,.- 0 .__ _ C 16B730ad 0.032 0.90 1.68 152 152 136 255 144 144 129 242 F ., 22A-tpl_... 6.989 . ; 27.69' .- '., 0.00._ .,.', 152 .,,_... 12 _ _ _332 .;, .. ._ 0 . ,._..,144 _. 0 _ 61 c) AED excursion 1 343 -72 Envelope loss/gain 1432 1669 129 170 12 a) Infiltration 376 106 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 1809 1776 129 2170 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 44 747 -129 -2170 14 Subtotal 1853 2523 0 0 15 Duct loads 35% 57% 649 1446 35% 57% 0 0 al room l oad 2122 5021 3980 Air required (c m) I 0 I O Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A-1- 2019-Jul-21 15:15:27 a- RightSuite® Universal 2019 19.0.08 RSU06570 Page ransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE J. wrightsoffi Right-M Worksheet Job: Entire House Date By: Adams Homes 754 se Port St Lucie Blvd., Port St Lucie, FI 34984 July 21, 2019 1 Room name laundry wic 2 Exposed wall 3.0 It 6.0 ft 3 Room height 8.0 it heat/cool 8.0 It heat/cool 4 Room dimensions 9.0 x 6.0 It 12.0 x 6.0 ft 5 Room area 54.0 ft' 72.0 ft' Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .7 _0sw .: .. _._ 0,097..,ne. :, 2:72, '4.00 2,58 z ..-,.: 0 ... _.. .p :... ___0:..._ _ 0 . _: __.96 -._ ...--96 ----_-.261.: _ -._24a 13A-4ocs 0.143 ne 2.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 PO 0.290 ne„ 8 12, 8 41, 0 _. 0 0 0 _ 0, _ 0 0 0 13A 4ocs r 0.143 se, 4 00 2:55 0 0 0 0 48 48 7192 122 .4A5.2ov -,. _ ,__ ._': , , ,. _ ,0:470 _se_: ._-131.6: ,22.79. r _ _'.0 w> . _3-: 0 _.__;__- 0 _ _,.__0 - : _0 -_ _-.. _._0 _ _. _...0. _ 0 13A-4ocs 10D-v 0.143 0.490 sw sw 4.00 13.72 2.55 9.84 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 0 0 0 0 4A5 2ov - _ 0.470 ,.sw_, 13 16., 13.55 0 0 0 _ .. 0 ,... 0 0 0 0. W 13A4ocs:r:__ ,... _.:. 01_43 : nw; _ ,_4'-00: _:-2:55 ...._ ... 24 .. _ _ 24, ":, 96 .._,;': 61 _s _.... 0 :_._0 .. _.. 0 .01 C , ...:168-30ad. _ __ _ 0 032 -.. 0 90 1.68 _._...54 - 48 91 72.---._^ 72 65..-.-_ ._ 0.989 ` .,, r 27.69, _'6.00 n -y . ._,54 5 _83F. 0 2 6:4 _.__.-.121 xi o _ - X y 61 c) AED excursion 1-51 1 119 Envelope loss/gain 1 228 146 1 1 684 472 12 a) Infiltration 54 15 322 91 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 281 1621 1006 563 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 351 795 125 48 14 Subtotal 632 957 1131 611 15 Duct loads 35% 57% 221 549 35% 57% 396 350 Total. room load 8541 1505 15271 961 Air required (cfm) I 42 68 I I 75 44 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrr9g@�aa0 2019-Jul-2115:15:27 ^ Right -Suite@ Universal 2019 19.0.08 RSU06570 Page 9 ransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE qw 1r r ghtsoW Right-M Worksheet Entire House Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 Job: Date: July 21, 2019 By: 61 c) AED excursion 1 1-51 1 1 11 Envelope loss/gain 317 130 20 36 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 406 156 20 36 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -406 -156 13 219 14 Subtotal 0 0 33 255 15 Duct loads 35% 57% 0 0 35% 57% 11 146 Total room load 0 0 441 401 Air required (cfm) 0 0 I I 2 18 Calculations aDaroved by ACCA to meet all reouirements of Manual J 8th Ed. 2019-Jul-21 15:15:27 �— Right -Suite@ Universal 2019 19.0.08 RSU06570 Page 10 ransfer\Manual J\5811 Balsam Dr Adams Homes.rup Calc = 10J8 Front Door faces: NE vvrrightsoft Right-J® Worksheet Job: Entire House Date: By: Adams Homes 751'se Port St Lucie Blvd., Port St Lucie, FI 34984 July 21, 2019 1 Room name mstr bath mstr bedrm 2 Exposed wall 5.0 ft 29.0 ft 3 Room height 8.0 ft heat1cool 8.0 ft heat1cool 4 Room dimensions 1.0 x 88.0 ft 13.0 x 16.0 ft 5 Room area 88.0 ft2 208.0 ft' Ty Construction U-value Or HTM Area (ft') I Load Area (ft') I Load number (Btuh/W-T (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 W - _.. 12BOsw_:_.., _...: 0.097, '.ne 2.72 __._.258: _ --o .r__0 - _.. _0.:.__._,._.,A . .`0 __._. _..0 13A-4ocs 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 ne 13.16 28.29 0 0 0 0 0 0 0 0 _ 11P0.. _. __ _. .__. __ 0.290 --ne.. ..... 8.12 _ 8.41 ._..... _ .._p _. _.. ..-0 .,._...._ -0 .... -. _. - .. --- -0 0 __._.-. __0 .._. ._..0 -- W 13A 4ocs 0,143 se " 4.00 2.55 40 40 160 102 128 112 449 285 „ ( 4A52ov.-, ._ _ :- . ._m. _0.470 .se_ 13.16. ,- 22.79. _ _:0 _,-_.- _.- 0 _,_ .' _ 0 _;.._- .0 r_ .__16 ,_- _a_'_.6 _ _ - -209. _.. _ _362 Vy 13A-4ocs 0.143 sw 4.. 0 0 0 0 104 72 289 184 10D-v 0.490 sw 13.72 72 9.8484 0 0 0 0 0 0 0 0 4A5-2ov 0.470 sw 13.16 22.79 0 0 0 0 32 12 418 725 II�CCGI W. 0,5-2ov.. 13Q-4ocs... 0.470_. _ 0.1-43 sw. riw- 13.16.. _, 4.00, _13.55 __„2.55 .. 0 -_ ,.._r 0 0 :'... w ...0 ._0 ._.._0 _ 0 _. '.,_ ._0 ..... .._ .0 . a0 .._..... _.0 .. 0 0 0 0, ..., _ .._0 C, 16B30ad- _ _ -, „0.032, -_ _0.90,- 1.68 88 . -88 79. - 148 -208 .. 208 -. _ 1.86, - _ 349 F .. .. _.:•_ 22A-tpl . _..- _. = '. _ .._' �_ _ -. _�__. 0:989 _._..,,_ _ e:`r •� � ;.;27.69 .ram ,... --.. _ 0.00' -. _'....` 88 -.�_ -__-,-- - - 5 _.w_ ,._-. .' .138 _ ._ _ _ 0. �__ z- _ -..__ 208 _._ _ .. 29 _:__. , ....: bM ___. 0. _ ._. �. 6 c) AED excursion 1 -91 1 1 1 155 Envelope loss/gain 377 241 2355 2030 12 a) Infiltration 90 25 520 146 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 467 266 2875 2667 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 301 436 13 219 14 Subtotal 768 702 2888 2886 15 Duct loads 35% 57% 269 402 35% 57% 1011 1654 Total room load 1037 1105 3899 4540 LAir required (cfm) I I I- 51 I 50I I I 190 I 206 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. v+rr�7glf w7C ea 2019Jul-21 15:15:27 Rig ht-Suite® Universal 2019 19.0.08 RSU06570 Page 11 ransferwanual JX5811 Balsam Dr Adams Homes.rup Calc = MJ8 Front Door faces: NE Sheet 1 12" 14 x 14 14 x 14 dining bedrm 2 mstr bedrm 12 x 1 x 12 153 cfm 10 x 10 T 180 cfm great rm T 14x8 206 cfm T 8 12 x 12 T 9 11 cz 8" 226 cfm 6 c 16 8 x 4 g!11 46 cfm 4" bath duct 10 x 6 5 " h bath to roof cap 4" bath 51 cfm fan by others '� ■ duct to mstr bath 12.. c4 x 9 I c3 ' 6 cfm roof cap 4" fan by x I' 18 cfm 12x12 7" 912x12 others toilet L 5" 5' foyer 10k6 12x6 10 x 6 he 120 cfm 151 cfm 68 cfm F bedrm 4 bedrm 3 10 x 6 wic laundr 75 cfm 4" bath duct to roof cap w/dryer vent box garage Job M Adams Homes Scale: 1 : 108 Performed for: Page 1 5811 Balsam Dr 751 se Port St Lucie Blvd. Right -Suite® Universal 2019 5811 Balsam Dr Port St Lucie, FI 34984 19.0.08 RSU06570 Fort Pierce, FI 2019-Jul-21 15:15:40 ...J\5811 Balsam Dr Adams Homes.r Manual S Compliance Report Job: 1i rightsof to Date: July 21, 2019 Entire House By: Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 Project Information • For: 5811 Balsam Dr, Adams Homes 5811 Balsam Dr, Fort Pierce, FI Cooling Equipment Design Conditions Outdoor design DB: 90.0°F Sensible gain: 27375 Btuh Entering coil DB: 79.2°F Outdoor design WB: 78.0°F Latent gain: 6039 Btuh Entering coil WB: 64.5°F Indoor design DB: 75.0°F Total gain: 33415 Btuh Indoor RH: 50% Estimated airflow: 1167 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1167 cfm Sensible capacity: 28127 Btuh 103% of load Latent capacity: 5436 Btuh 90% of load Total capacity: 33563 Btuh 100% of load SHR: 84% Heating Equipment Design Conditions Outdoor design DB: 42.0°F Heat loss: 23898 Btuh Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1167 cfm Output capacity: 32254 Btuh 135% of load Supplemental heat required: 1 0 Btuh Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1167 cfm Output capacity: 7.0 kW 100% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. Entering coil DB: 69.17 Capacity balance: 33 °F Economic balance: -99 °F wrightSoft- 2019-Jul-21 15:15:28 ti ,k•r, «.,cm, a Right -Suite® Universal 2019 19.0.08 RSU06570 Page 1 ...ransfer\Manual J\5811 Balsam Or Adams Homes.rup Calc = MJ8 Front Door faces: NE . wrightsoft. Duct System Summary Entire House Adams Homes 751 se Port St Lucie Blvd., Port St Lucie, FI 34984 e-roject intormation For: 5811 Balsam Dr, Adams Homes 5811 Balsam Dr, Fort Pierce, FI Job: Date: July 21, 2019 By: Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O - Available static pressure 0 in H2O 0 in H2O Supply / return available pressure 0.000 / 0.000 in H2O 0.000 / 0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 1167 cfm 1167 cfm Total effective length (TEL) 189 ft Supp'ly Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk bedrm 2 h 2608 153 119 0 7.0 Ox 0 VIFx 17.4 100.0 bedrm 3 h 2638 151 120 0 7.0 Ox 0 VIFx 10.2 100.0 bedrm4 h 2439 120 111 0 6.0 Ox0 VIFx 5.2 100.0 dining C 3969 122 180 0 8.0 Ox 0 VIFx 24.9 125.0 st1 great rm-A c 4972 215 226 0 0 Ox 0 VIFx 7.4 100.0 h bath h 531 46 24 0 0 Ox 0 VIFx 8.0 100.0 laundry c 1505 42 68 0 5.0 Ox 0 VIFx 26.2 125.0 st1 mstr bath h 1105 51 50 0 5.0 Ox 0 VIFx 33.0 145.0 st2 mstrbedrm c 4540 190 206 0 8.0 Ox 0 VIFx 35.2 145.0 st2 toilet c 401 2 18 0 4.0 Ox 0 VIFx 34.2 145.0 st2 Wic h 961 75 44 0 5.0 Ox 0 VIFx 44.2 145.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 318 319 0 584 10.0 0 x 0 VinlFlx st1 st1 Peak AVF 482 567 0 722 12.0 0 x 0 VinlFlx Bold/italic values have been manually overridden V4/1•jghtsoft- 2019-Jul-21 15:15:28 Right -Suite® Universal 2019 19.0.08 RSU06570 Page 1 /+ ...ransfer\Manual J\5811 Balsam or Adams Homes.rup Calc = MJ8 Front Door faces: NE Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb1 Ox 0 1167 1167 0 0 0 0 Ox 0 VIFx f� �' • �.,..�...�,.,.q,.., Right-Suite®Universal 2019 19.0.08 RSU06570 'I'M ...ransfer\Manual J\5811 Balsam or Adams Homes.rup Calc = MJ8 Front Door faces: NE 2019-Jul-21 15:15:28 Page 2 � a Sheet 1 TP1z^ 14 x 14 14 x 14 dining bedrm 2 12 x mstr bedrm 1 x 12 153 cfm 10 x 10 T 180 cfm great rm T 14x8 206 cfm T 8 12 x 12 T 9„ c2 8" 226 cfm 6 c 16 8 x 4 8 46 cfm 4" bath duct 7\ 10 x 6 5.. h bath to roof cap 4" bath 51 cfm y fan by others duct to mstr bath nhc 2 „ c4 x 9 roof cap 4 „ i 6 cfm I c3 fan b x others li 18 cfm12 x 12 7 12 x 12 toilet ,yL 5" 10X6 6" 12x6 10 x 6 120 cfm 151 cfm bedrm 4bedrm 3 68 cfm 10 x 6 wic laund 75 cfm 4" bath duct to roof cap w/dryer vent box garage Job M Adams Homes Scale: 1 : 108 Performed for: Page 1 5811 Balsam Dr 751 se Port St Lucie Blvd. Right -Suite® Universal 2019 5811 Balsam Dr Port St Lucie, FI 34984 Fort Pierce, FI 19.0.08 RSU06570 2019-Jul-21 15:16:21 ... J\5811 Balsam Dr Adams Homes.r