Loading...
HomeMy WebLinkAboutDock PlanGENERAL NOTES: k "� 1.) STAGING OF EQUIPMEN'i AND MATERIALS 12.) NO SEAGRASSES ENCOUNTERED DURING SITE INVESTIGATION.- WILL BE ON THE LOT. PLATFORM TO BE CONSTRUCTED IN SANDY/MUDDY AREA 2.) THE CONTRACTOR WILL USE A 10'X20' BARGE AND 13.)ALL CONSTRUCTION SHALL BE IN CONFORMANCE WITH - USE JETTING OF THE PILES. , :LOCAL, STATE, & FEDERAL RULES, PERMIT �.) THE DOCK WILL USE 64: PILINGS. CONDITIONS OR EXEMPTIONS AS APPROPRIATE. 4.) DOCK CONSTRUCTION IS ESTIMATED TO TAKE FIFTEEN 14•) TOTAL AREA OF THE DOCK IS: PLATFORM = .144 SF. DAYS WITH 5 PILES A DAY AVERAGE. WALKWAY OVER WATER = 800 SF. WALKWAY OVER LAND. 5.) THE ONLY, NOISE FACTORS WILL BE POSSIBLE = 160 SF. TOTAL DOCK IS 1,104 SF (OVER WATER = 944 SF). n HAMMERING AND DRILL GUNS. NO PILE DRIVING OR 15.) CONSTRUCTION OF THE WALKWAY, DOLPHIN PILES & ROCK CRUSHING IS EXPECTED FOR THIS SITE. BOAT LIFT SHALL BE FROM BARGE & LAND, ACCESS AT LOT. THE PILES SHALL BE SHALL @E FROM BARGE 6.) THE PROJECT WILL ONLY BE COMPLETED DURING -& LAND, ACCESS AT LOT. THE PILES §HALL BE .DAYLIGHT HOURS. JETTED INTO PLACE, TURBIDITY WILL BE CONTROLLED 12' X 12' 7.) ONLY ONE BARGE WILL BE USED FOR THE WITH TURBIDITY CLOTH OR BOOMS. PLATFOR 11 CONSTRUCTION OF THE SITE. (144 SF� _ ja 8.) A SPOTTER WILL BE USED TO PREVENT IMPACTS TO SEA TURTLES, SMALLTOOTH SAWFISH, ETC. USE JETTING OF THE PILES. I. 4' 4' 9.) MAXIMUM PILING SPACING IS 10 FEET. 10.) MEAN HIGH WATER LINE (0.73' N.A.V.D.) ESTABLISHED DOUGLASUREAUHOF SURVEYINGGMPSON & MAPPING 'FDEP' ON 2/8/95. 4 11.) DOCK TO AVOID MANGROVES AND ALL INDIGENOUS WETLAND VEGETATION. II--_4'-0• WIDTH OF DECKING I 3'-8• BETWEEN PILINGS 2x6 COMPOSITE OR PT DECKING r� 4,-O• B• DOCK PLAN FASTENED MDECK SCREWSWS AT AT EACHACH CROSSING (1/2' GAP BETWEEN EACH BOARD SCALE: N.T.S. 41 6X6 PT AFTER SHRINKAGE) 8• DIA PT BUTT PILES nl OC FASTEN 2X8 STRINGER TO 2X8 2XB BENT h - W 2) N92X68X3" SS SCREWS, 2X8 PT STRINGERS F TO AT 2P' FOR WOOD WITH (4) i9X3' SS SCREWS AND 16" FOR COMPOSITE 6' (TYP) FASTEN W/ (2) 1/2• DIA. SS ® THREADED ROD W/ 1 #" ROUND ® ® SS WASHERS EACH SIDE 2x8 PT BENTS (1 EACH 2p? SIDE OF POST) WALKWAY 2X PT BLOCKING BETWEEN WATER X-BRACING FASTENED W/ OVER00 SF) 1/2' SS THREADED Roo 40' X 4' AND I }• ROUND SS WALKWAY WASHER OVERLA ,D IN FASTEN X-BRACE W/ 160 SF 1 /2• SS TREADED ROD W/ -My imill. Elm ROUND SS WASHER -1. MLIL NAVD ._2X8 PT X-BRACING ONE EACH SIDE 0.030" THICK HIGH DENSITY POLYETHYLENE PILE WRAP' 10 EMBED PILES TO A MINIMUM 6' DEPTH WITHIN CLEAN '.. SAND (TYP.). DRILL THROUGH CAPROCK IF NECESSARY /\// 4 WALKWAY SECTION SCALE: N.T.S. LOCATION MAP MIDWAY ROAD North PROJECT SITE PROPERTY OWNERS _DWARD KLINE 5003 S. INDIAN RIVER DRIVE FORT PIERCE, FL 34982 ADJACENT PROPERTY OWNERS 1.) ROLANDO MELJEM 5001 S. INDIAN RIVER DRIVE FORT PIERCE, FL 34982 J ROBERT ESSAY 5005 S. INDIAN RIVER DRIVE FORT PIERCE, FL 34982 PURPOSE TO CONSTRUCT A DOCK DATUM: M.S.L. IN: FORT PIERCE, FL AT: 5003 S. INDIAN RIVER DRIVE PARCEL ID NO.: 3401-602-0001-01C COUNTY OF: ST. LUCIE STATE: 4' X 40' WALKWAY SECTION OVER LAND SCALE: N.T.S. 12'-0• WIDTH OF DECKw6 -- it'-8' BETWEEN PILINGS— - - FASTEN 2X8 STRINGER TO 2X6 2x5 COMPOSITE OR PT DECKING W (2) ¢BX3" 58 5(XtEWS, F,ISTENS / (2) mcr SS DEC( 8• DIA PT CREWS AT EACH CROSSING BUTT PILES FAS1Ef1 2X6 TO 2X8 BENT PATH (4) /9X3• SS SCREWS ('1/2" GAP BETWEEN EACH BOARD AFTER SHRINKAGE) h 2X8 PT STRINGERS OR WDOD-, AT 24 FO AND 18" FOR - COIPOSITE ® \�200 PT OEM } WE OF POS'h (1 FACT IIITIINEAOED FASTEN W� w i�OUIIDIF SS WABIU SIDE �y -073' WWL NAVD_ -1NAVD 2X8 PT FASTEN X-BRACE W/ X-BRACING 2X PT BLCNG BETWEEN EACH SIDE Y(I 1/M 55 TREADED ROD W/ 1 r ROUND 4S WASHER X-11RACNG FASTENED W/ 1/2' SS THREADED ROD 0.030" THICK HIGH -. AND 1 >)" ROUND SS DENSITY POLYETHYLENE WASHER PEE WRAP DRILL THROUGH CAPROCK AND EMBED PILES TO POINT OF REFUSAL AND A MINIMUM OF 6' BELOW LISTING I� I. BOl'EON: GRADE (TYP.) \X/ 12' X 12'1' PLATFORM SECTION SCALE: N.T.S. 4-lL8jC0Ry a I'ZKI R I WED FOR CODE COMPLIANCE ST. L CIE COUNTY BOCC 11-714 G-8 REVIEW ALL SHOP DRAWINGS FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS AND FOR COMPLETENESS AND ANSWER ALL CONTRACTOR RELATED QUESTIONS. STAMP AND INITIAL ALL SHEETS PRIOR TO SUBMITTING SHOP DRAWINGS TO ARCHITECT/ENGINEER FOR REVIEW. NON-COMPLIANCE WITH THIS REQUIREMENT WILL RESULT IN REJECTION OF SUBMITTAL. D-4 SEISMIC: ZONE 0 D-5 GEOTECHNICAL REPORT WOOD REQUIRED MAXIMUM POST LOAD 1700 POUNDS COMPRESSION. WD-1 ALL WOOD CONSTRUCTION AND CONNECTIONS. SHALL CONFORM TO SEE NOTE DF-2 FOR REQUIRED CAPACITY. PILES SHALL BE ARC "AMERICAN INSTITUTE OF TIMBER CONSTRUCTION" MANUAL, INSTALLED TO A DEPTH TO A611EVE REQUIRED CAPACITY EDITION, AND THE "NATIONAL DESIGN SPECIFICATIONS" FOR WOOD CONSTRUCTION, 1991 EDITION, AND FLORIDA BUILDING CODE, CHAPTER 23. GENERAL NOTES WD-2 ALL TIMBER TO PRESSURE TREATED (2.5CCA PILES), (0.40ACQ FRAMING) G-1 REVIEW ALL PROJECT DOCUMENTS PRIOR TO FABRICATION AND START OF CONSTRUCTION. REPORT ANY DISCREPANCIES TO ARCHITECT OR WD-3 DIMENSIONED LUMBER SHALL BE DRESSED S4S, AND SHALL BEAR STRUCTURAL ENGINEER PRIOR TO PROCEEDING WITH WORK. THE GRADE STAMP OF THE MANUFACTURER'S ASSOCIATION. G-2 IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT EXISTING WD-4 ALL LUMBER NUMBER i GRADE AND SHALL BE SOUND, SEASONED, FACILITIES, STRUCTURES AND UTILITY LINES FROM ALL DAMAGE AND FREE FROM WARP. STRUCTURAL RA DESIGN RIT RA DURING CONSTRUCTION. G-3 NO STRUCTURAL MEMBER SHALL BE CUT, NOTCHED OR OTHERWISE WD-5 ALL CONNECTION HARDWARE IN CONTACT WITH PRESSURE TREATED D-1 CODES: - 2017 FLORIDA BUILDING CODE REDUCED IN SIZE OR STRENGTH WITHOUT PRIOR APPROVAL IN WOOD SHALL BE 316 SERIES STAINLESS STEEL, ALL OTHER WRITING FROM THE STRUCTURAL ENGINEER. CONNECTORS SHALL BE SUPPLIED BY SIMPSON STRONG -TIE CO., INC.,OR APPROVED EQUIVALENT MANUFACTURER AND SHALL BE D-2 DESIGN DEAD LOADS: 0-4 COORDINATE STRUCTURAL AND OTHER DRAWINGS THAT ARE PART OF 316 SERIES STAINLESS STEEL. USE EQUIVALENT MATERIALS FOR SELFWEIGHT THE CONTRACT DOCUMENTS FOR ANCHORED, EMBEDDED OR SUPPORTED NAILS AND SCREWS AS FASTENER. DESIGN LIVE LOADS: ITEMS WHICH MAY AFFECT THE STRUCTURAL DRAWINGS (I.E. MECHANICAL, SINGLE FAMILY DOCKS 40 PSF ELECTRICAL, PLUMBING, DUCTWORK, ETC.) WO-7 FRAMING MEMBERS SHALL BE FASTENED TOGETHER IN ACCORDANCE WITH SECTION 2306 OF THE FLORIDA BUILDING CODE, EXCEPT WHERE G-5 ALL DETAILS AND SECTIONS ON THE DRAWINGS ARE INTENDED TO BE FASTENING SCHEDULES ARE MORE STRINGENT IN THESE PLANS. D-3 ULTIMATE DESIGN WIND SPEED, Vult: 160 MPH (3 SECOND GUST) TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR NOMINAL DESIGN WIND SPEED, Vult: 124 MPH (3 SECOND GUST) SITUATION ELSEWHERE ON THE PROJECT EXCEPT WHERE A SEPARATE WD_8 PROVIDE ADDITIONAL UPLIFT CONNECTORS TO RESIST UPLIFT LOADS IN RISK CATEGORY: I DETAIL IS SHOWN. ACCORDANCE WITH CONNECTORS SPECIFIED ON PLAN OR ON DETAILS. WIND EXPOSURE CATEGORY: D - HEIGHT, H: 5.0 Fr G-6 THE INTENTION OF THE PLANS AIJD SPECIFICATIONS IS TO PROVIDE DEEP FOUNDATION LATTICE FRAMEWORK (CLEAR WIND. FLOW) ALL NECESSARY DETAILS TO CONSTRUCT A COMPLETE STRUCTURE. NET FORCE COEFFICIENT: CN = VARIES 1.3 TO 1.8 WHEN SPECIFIC INFORMATION IS ,MISSING OR IS IN CONFLICT. THE CONFLICTS SHALL BE BROUGHT TO THE ATTENTION OF THE DF-1 PILES SHALL BE PRESSURE TREATED 8" OR 10' DIA BUTT PILES (2.5CCA) ARCHITECT/ENGINEER. ASSUMPTIONS: DF-2 ALL PILES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE. A. BUILDING IS ASSUMED TO BE A LATTICE FRAMEWORK STRUCTURE G-7 THE ENGINEER SHALL NOT BE RESPONSIBLE FOR LAYOUT, RECOMMENDATIONS OF THE SOILS ENGINEER AND PROVIDE THE AS DEFINED BY ASCE 7-10 DIMENSIONAL ERRORS OR DISCREPANCIES RESULTING FROM Nt FOLLOWING CAPACITIES REPRODUCTION AND USE OF CONTRACT DRAWINGS FOR ERECiTMN AND 1.7 K KIPS COMPRESSION C. OWNER OR CONTRACTOR SHALL OBTAIN NECESSARY INSTALLATION .SHOP DRAWINGS. USE OF CONTRACT DRAWINGS REPRODUCE@ IN 0.50 KIPS LATERAL SPECIFiCATI0N5 AND INSPECTIONS REQUIRED TO COMPLY WITH WHOLE OR ANY PART IN SHOP DRAWINGS SHALL NOT RELIEV@E - MANUFACTURERS RECOMMENDATIONS FOR INSTALLATION OF CONTRACTOR NOR SUBCONTRACT' RS FROM THEIR RESPONSI BNL%TlH TO ACCURATELY LAYOUT, COORDINATE, DETAIL, FABRICATE AND DF-3 CONTRACTOR TO REVIEW GEOTECHNICAL REPORT FOR CONSTRUCTION, COMPONENTS AND CLADDING FOR HURRICANE PRONE REGIONS. INSTALL A COMPLETE STRUCTURE. LENGTH, INSPECTION, AND TESTING REQUIREMENTS FOR PILES. U z J �U a) M N J a ¢a) W fN LL N Q 00 U W O W J O m Q 2 d o W L tit ui {'//r T o ,��( N {O a) Z O N rn W W =WO s=�h J C.D�U)N oo� _j 00LL W Z W � � LLI W W Y Q >>04 �co J Qa 2 Ln ZN � rn VJ �~ U Z O Q LLJ C) > Ld —C) �:j V) 0 > � Q Ld JO''s3R W,SCH6.XE 1. REG MC` 4704t - - ys' fJ0 57396 ^ R: STOD7DSA;qRgD� . NO 555� / b F DA1 ^ d y SHc T 1 PROJECT N0. 20-173