Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED RODDEWIG-MANUAL J&D
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-05 09:04:15 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1 ...ocuments\Wrightsoft HVAC\RODDEWIG ADDIITION.rup Calc = MJ8 Front Door faces: N Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information RODDEWIG ADDITIONFor:10316 INVERNESS WAY, PORT ST. LUCIE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh36672 Structure Btuh26524 Ducts Btuh11734 Ducts Btuh17149Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh48405 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh41490 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh3236 Ducts Btuh4848Central vent (0 cfm) Btuh0 CoolingHeating (none)34433443Area (ft²) Equipment latent load Btuh8084 3098730987Volume (ft³)Air changes/hour 0.150.28 Equipment Total Load (Sen+Lat)Btuh49573 Equiv. AVF (cfm) 77145 Req. total capacity at 0.70 SHR ton4.9 Heating Equipment Summary Cooling Equipment Summary Make Make TraneTrade Trade EXISINTG A/C Model Cond 4TTV0060A1AHRI ref Coil AHRI refEfficiency 80 AFUE Efficiency 12.4 EER, 20 SEER Heating input kW0 Sensible cooling Btuh39900Heating output Btuh0 Latent cooling Btuh17100 Temperature rise °F0 Total cooling Btuh57000Actual air flow cfm1900 Actual air flow cfm1900 Air flow factor cfm/Btuh0.039 Air flow factor cfm/Btuh0.044Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-05 09:04:15Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1...ocuments\Wrightsoft HVAC\RODDEWIG ADDIITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House EXISTING 2 Exposed wall 358.0 ft 327.0 ft 3 Room height 9.0 ft 9.0 heat/coolft 4 Room dimensions ft3215.0x1.0 5 Room area 3443.0 ft²3215.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 441 369 1477 807 333 261 1045 571 .GG 4A5-2ob4A5-2ob 0.5600.560 nn 15.6815.68 16.1616.16 30 0 470 485 30 0 470 485 .DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 42 42 459 434 42 42 459 434 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 909 735 2943 1608 909 735 2943 1608 11 GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 30 4 470 1259 30 2 470 1259 GG 4A5-2ovd4A5-2ovd 0.4700.470 ee 13.1613.16 35.7935.79 144 13 1895 5154 144 6 1895 5154 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 702 582 2330 1273 702 582 2330 1273 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 60 120 2134 2086 60 60 2134 2086 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 60 120 2134 2086 60 60 2134 2086 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 675 645 2583 1411 504 474 1898 1037 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 30 4 1067 2612 30 2 1067 2612 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 495 495 1261 523 495 495 1261 523 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 3443 3443 3085 5509 3215 3215 2881 5144 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 3443 358 9914 0 3215 327 9055 0 6 c) AED excursion 0 0 Envelope loss/gain 32222 25247 30042 24272 12 a) Infiltration 4450 1277 3995 1146 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)36672 26524 34036 25418 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 36672 26524 34036 25418 15 Duct loads 32%65%11734 17149 32%65%10891 16434 Total room load 48405 43673 44927 41852 Air required (cfm)Air required (cfm)1900 1900 1763 1821 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Feb-05 09:04:15Right-Suite® Universal 2019 19.0.21 RSU08101 Page 2...ocuments\Wrightsoft HVAC\RODDEWIG ADDIITION.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name NEW SITTING NEW BATH 2 Exposed wall 11.0 ft 20.0 ft 3 Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft12.0x11.0 ft12.0x8.0 5 Room area 132.0 ft²96.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 13A-4ocs13A-4ocs 0.1430.143 nn 4.004.00 2.192.19 0 0 0 0 108 108 432 236 .GG 4A5-2ob4A5-2ob 0.5600.560 nn 15.6815.68 16.1616.16 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 .WW 13A-4ocs13A-4ocs 0.1430.143 ee 4.004.00 2.192.19 0 0 0 0 0 0 0 0 11 GG 4A5-2ob4A5-2ob 0.5600.560 ee 15.6815.68 41.9541.95 0 0 0 0 0 0 0 0 GG 4A5-2ovd4A5-2ovd 0.4700.470 ee 13.1613.16 35.7935.79 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ss 4.004.00 2.192.19 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 WW 13A-4ocs13A-4ocs 0.1430.143 ww 4.004.00 2.192.19 99 99 396 217 72 72 288 158 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 87.0687.06 0 0 0 0 0 0 0 0 PP 12C-0sw12C-0sw 0.0910.091 --2.552.55 1.061.06 0 0 0 0 0 0 0 0 CC 16B-30ad16B-30ad 0.0320.032 --0.900.90 1.601.60 132 132 118 211 96 96 86 154 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 132 11 305 0 96 20 554 0 6 c) AED excursion 0 0 Envelope loss/gain 819 428 1361 547 12 a) Infiltration 162 46 294 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)981 474 1654 632 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 981 474 1654 632 15 Duct loads 32%65%314 307 32%65%529 408 Total room load 1295 781 2184 1040 Air required (cfm)Air required (cfm)51 34 86 45 Bold/italic values have been manually overridden 2021-Feb-05 09:04:15 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 1 ...ocuments\Wrightsoft HVAC\RODDEWIG ADDIITION.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information RODDEWIG ADDITIONFor: 10316 INVERNESS WAY, PORT ST. LUCIE, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.250 / 0.250 in H2O in H2O0.250 / 0.250 Lowest friction rate in/100ft0.323in/100ft0.323 Actual air flow cfm1900cfm1900 Total effective length (TEL) ft155 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk 00VlFx0x0001661603812cEXISTING 00VlFx0x0001651603805cEXISTING-A 00VlFx0x0001651603805cEXISTING-B 00VlFx0x0001651603805cEXISTING-C 00VlFx0x0001651603805cEXISTING-D 00VlFx0x0001651603805cEXISTING-E 00VlFx0x0001651603805cEXISTING-F 00VlFx0x0001651603805cEXISTING-G 00VlFx0x0001651603805cEXISTING-H 00VlFx0x0001651603805cEXISTING-I 00VlFx0x0001651603805cEXISTING-J st1115.040.0VlFx0x06.00.32345862184hNEW BATH st1115.039.3VlFx0x06.00.32434511295hNEW SITTING Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 137 79 0.323 391 8.0 0x0 VinlFlx 2021-Feb-05 09:04:15 Right-Suite® Universal 2019 19.0.21 RSU08101 Page 2 ...ocuments\Wrightsoft HVAC\RODDEWIG ADDIITION.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb2 0x 19000 1900 0 0 0 0 x0 0 VlFx