Loading...
HomeMy WebLinkAboutAPPROVED Roddewig Truss PlanEN'r31f URED TUBER THUSS SYSTEMS ' FRODUCiS WARNING* ALL BEARING POINTS MUST BE INSTALLED PRIOR TO INSTALLING ANY TRUSSES! FAILURE TO 0 SO MAY RESULT IN DAMAGED TRUSSES AND WILL OID ALL WARRANTIES. CHIS IS A PLACEMENT FLAN FOR ENGINEERED COMPONENTS AS DEFINED BY WTCA 1 - 1995. DIAPHRAMS HAVE NOT BEEN ANALYZED BY i EAST COAST TRUSS. =0R ERECTION AND INSTALLATION OF TRUSSES ! FOLLOW INSTRUCTIONS ON THE BCSI-131 SUMMARY SHEETS AND SEALED ENGINEERED TRUSS DRAWINGS 11 ADDITION NOTE:.. IT IS THE BUILDERS RESPOR$151LLTY TO ERIFY ALL EXISTING CONDITIONS, ECT CANNOT BE RESPONSIBLE FOR MATCHING EXISTING ROOF CONDITIONS. UPON SIGNING. BUILDER AGREES TO ALL CONDIT �1.. .. 1) FOR THE ERECTION BRACING FOLLOW NSTRUCTIONS ON THE BCSI-131 SUMMARY SHEETS 2) PERMANENT BRACING FOR THE STRUCTURE IS HE RESPONSIBILITY OF OTHERS. 3) INSTALL WEB BRACING AS STATED ON SEALED ENGINEERING TRUSS DRAWINGS. STRUCTURAL DATA, NUMBER OF GIRDER AND TRUSS PLIES AND THE CONNECTION INFORMATION. OUR DESIGN DEPARTMENT MUST APPROVE ALTERATIONS AND/OR REPAIRS TO TRUSSES IN ADVANCE. BACK CHARGES WILL NOT BE ACCEPTED UNLESS DU DESIGN DEPARTMENT APPROVES THEM IN ADVANCE ALL HANGERS ARE SIMPSON STRONG -TIE OR USP UNLESS OTHERWISE NOTED. INSTALL HANGERS kCCORDING TO THE CURRENT SIMPSON STRONG -TIE )R USP CATALOG BEARING ELEVATIONS EXISTING ASSUMED @ 10'-0" A. F.F. EXISTING @ 12'-2€€ A.F.F. 12 6� 4 3/16" HEEL 3 i9. 12 2€ 0€t TYPICAL END DETAIL '_c C)f= LraA.95 tk_� s44 At;E L F u P, Indicates Let End ,0Of Truss On Layout & Engineeri Sheets SHQP DRAWING BMITTAL RE I,JARPROV�p O REWSEAND RESUBh71 A OVSDAS NOTED 0 REJECTED SUBMITTAL WAS pr% ­..__ _ - ------ _ GENERAL CONFC ONLY. THE Co GONFtRMfNG AND FULL By.. - --A A Digitally signed IM`M Manuel Manuel Martine • Date: ,2021.02.23 w Ma rti ne ,18 , _ 42 M051001 F- Z ELT EAST COAST TRUSS 5285 ST. LUCIE BLVD. Fr. PIERCE. FL 34946 OFFICE: (772) 466-2480 FAX: (772)466-5336 CUSTOMER:Biosca Construction JOB NAME: Roddewig Addition ADDRESS:10316 Inverness Way CITYICOUNTY:Port St. Lucie / St/ Lucie I �•`�}cL' MART�`�e�f �rGGr rrAr.''.� rY 7 . M 4ri Vl q. 71.8 "' •r �' C� t +� � r � J1D'- SlIATE OFDATE 4+� U•'.. •.' + `` r • kt ...IN . SERIAL. # 400165OF1B6EIE10899A91IFBD8955F7 This drawing has been electronically signed and sealed by Manuel Martinez, P.E. (FL. Lit. #471.82) an the date shown above using a SHA-I authentication code. JOB # J41330 JOB # �+ MODEL:Custorn SQ FT 9 02/22/21 LATEST=/ 1 ACCORDANCE Tl ME PEMUDA ADMINISTRATIVE CODE 61G1SS-31.003 (3) (c), EAST COAST TRUSS Is the "Trutt Deslgn Engineer" Trusses are designed In accordance with the Florida Building Code NOTE: A printed topics of this document are not considered signed By approving this placement plan(s), signatured and sealed and the SHA-1. authentication code mast be anywhere On this sheet, the customer or his verified on any electronic copies. representitive acknowledges that this placement plan i complies with the structural intent of the project. The customer also acknowledges that this approval authorizes EAST COAST TRUSS to manufacture these trusses and deliver them to the project indicated on this drawing. The customer also acknowledges that he/she accepts financial responsibility for any repair, engineering, and Q labor required due to errors other than those of EAST COAST TRUSS, Z Signed: Date: LL W CODE = FBC 2020/TP12014 ASCE 7-16 0— DESIGN CRITERIA =MWFRS OCCUPANCY CATEGORY= 11 EXPOSURE = C MWF SPEED =160 BUILDING TYPE =ENCLOSED U) MEAN HEIGHT: 15 U) GRAVITY LOADS U) W FLOOR: DUR FACTOR= 1.0 Z , PSF=TCLL-TCDL-BCLL-BCDL 40.0110.010.0,5.0 ROOF: DUR FACTOR= 1.25 W PSF=TCLL-TCDL-BCLL-BCDL 20.0120.0,0.0J 0.0 Cn LOADS PER FBC & FRC U) *NON -CONCURRENT BC LL 10psf ry CONCURRENT BC STORAGE LL 30 psf �-- W U) DEFINITIONS MWF = MAIN WIND FORCE O C&C = COMPONENTS AND CLADDING �-- TOB = TOP OF BEARING W TC = TOP CHORD BC = BOTTOM CHORD U) LL = LIVE LOAD DL = DEAD LOAD psf = POUNDS PER SQUARE FOOT # = POUNDS O UPLIFT MUST BY-PASS FLOOR TRUSSES Z UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. O ALL GIRDER/COLUMN LOADS MUST ❑ BY-PASS FLOOR TRUSS UNLESS SHOWN ON ENGINEERED TRUSS DRAWING. !X6 STRONG BACK BRACING, 10'-0" O.C., 1S >— RECOMMENDED ON FLOOR TRUSSES (L SPANNING 20'-0" OR MORE O AUTION: SPANS GREATER THAN 30'-0" IUST BE SET WITH A SPREADER BAR. THE PREADER BAR SHOULD BE AT LEAST 112 J O �3 IN LENGTH AS THE SPAN OF THE TRUSS SING SET. ,EFER TO BCI-B1 FOR COMPLETE O RECTION AND SAFETY PROCEDURES. 0 ALL BEAMS BY BUILDER ry NOTE. TRUSSES DO NOT Q� SUPPORT ANY PLANT SHELVES 1- t- 2- y- 3- O 5- 6- r TRUSS PLACEMENT PLAN (1/4" if plotted 24x36) . Designed By: SJ