HomeMy WebLinkAboutAPPROVED Contract WaltonIM5V Panel
?gga-(miR)-24"-W5de 5V panel on 15/32" plywood
Florida Product Approval Number 29444.4
. CoMpliance statement:
Manufacturer:
Product:
Material:
Fastener: .
Substrate/Deck:
Underiayment:
Slope.
Technical Documentation:
This product as described has demonstrated compliance with
Florida Building Code 2020, Section 1504.3.2, as required by Rule
61 G20-3, method 1 D
Integrity Metals, LLC 12640 Piper Dr, Ste. B, Vero Beach, FL
32960 1 772-584-2654 l www.intregritymetaisfi.com
iM5V is an exposed fastener 5V style panel with a 24" coverage,.:.,s.
and nominal rib height of 7/16."
This product is manufactured from 26ga (min) steel with corrosion
resistance per FBC 1507.43..,
#10 x 1-1/2" fastener with sealing washer, compliant with FBC
1506.6. Larger diameter and longer lengihfasterers :are
acceptable. Stainless steel fasteners maybe used.
Minimum 15/327 thick plywood
Comply with FBC 1507 1 A where applicable.
Comply WithFBC 1507 4 2 where applicable.
This product has been tested to the UL 580-06 and UL 1897-04
(rev sed.200) ) standard by.lntertek Testing (TST-1527), report
17226 03-450-44 R0. This test report is owned by Quality Metal
Roof Fabricators, who has given written authorization for Integrity
Metals to use this report.
116Psf ( install fasteners in 12-12" pattern (one fastener
per rib), at 12" o.c. max.
Installation Requirements: Factor of Safety of 2.0 applied to calculate allowable loads.
Evaluated,By. David Eng PE
Timberlake Cove,'-.,.
LLC
tip„ ►, �, r, 3324` W Univ. Ave # 206; Gainesville fk 32607
PJID E. ��,�i PE L!C No: 81377
p .. • y CA Lic. No: 33344
www.timberiakecove.com
Rio. 8137T
OF
www.integrityMetaisFi.com Page 1
INTEGRITY
METALS
META! ROOFING MADE HERE
Panel Accessories:
FL29444A
2604 Piper St Ste B
Vero Beach FL 32609
(772) 584-2654
The manufacturer does not require the use of closures,
sealants, butyl, or other similar accessories between bottom
edge of panel and drip edge, or in other locations. The use
of closures and sealants may be advisable in some cases,
however that decision is the discretion of the project owner
and the installer.
David Eng, PE and Timberlake Cove, LLC do not haVe nor
will acquire a financial interest in any company
manufacturing or distributing products under this evaluation.
The same entities do not have, nor will acquire, a financial,
interest in any other entity involved in the approval press.
of the product.
Design of deck and roof structure (to include attachment of,'
plywood or wood plank) shall be completed by others Fire
classification and; shear diaphragm design are outside the
scope of this evaluation.
This report is limited to compliance with structural wind load
requirements of FBC1504.3.2, as required by Rule 611320.-
3. Neither. Timberlake' Cave nor the. manufacturer shall :be
responsible for any conclusions interpretations; or designs
made by others based on this evaluabon;.report This report
is limited solely to documenting compliance'Wit.• Rule
61G20 3:and 'rnakes no exoress•or`imotied:warranty
design code in force, using allowable stress. These load
tables are based on ASCE 7-16. Use of these tables
assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions
and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or
_ instability, ror does it,have`a site iacationfor which
channeling or buffeting warrant consideration
Engneennganalysis'rriay be„completed by other licensed,
engineers for project specific approval by local authorities
having jurisdiction.
www.IntegrityMeta[sFi.com
Page 2
INTEGRITY
METALS
METAL RODflNG MADE HERE
Design Load Tables:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone
concept. For the load tables below, the worst case
was taken for each zone and reported using the
standard zones 1-2-3:
Zone 1 includes zones 1 and V
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
2604 Piper St Ste B
Vero Beach FL 32609
(772) 584-2654
.: mx C.LFl.S�„glOviK"aKHSq" 090H Vn KJKKA65Y4tFR,6"f Mf
lESi LIMY ty„n{♦'.mlCAft W,tlt6viKOsKN9S11d19T104M,
ORASOGIU",MCOBYGf:.hG""N Oi1;"AMUCxBtECOpC
ROOF ZONES FOR GENERIC BUILDING
Combining these zones creates a clear, simple scheme, at the expense of some design efficiency.
Contact the manufacturer for further information, or consult a licensed design professional.
FASTENER PATTERN AT 12" O.C.
Method A: Install fasteners in 9-
12-12" paftem (one fastener per
rib), at 12" o.c. max
NR: Consult a design
`professional to assess the
#10 X 1-12" WOOD SCREW W/ proposed installation
SEALING WASHER
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gablelhip roof with max slope of 45°
Have a mean roof height of 30 feet or less
FL29444.4: 26pa IMSV on 15132" ptvwood
Wind 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A A
Zone 2: A AAA A A A A
Zone 3: A A AA AAA
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gable/hip roof with max slope of 45,
Have a mean roof height of 30 feet or less
FL29444.4: 26pa IM5V on 15/32" olvwood
I
a
Use this toad table for structures which meet the following criteria: Use this load table for structures which meet the following criteria:
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with Have either a flat roof less than 7°, hip roof with
max slope of 45°, or gable roof with slope between 20° and 450 max slope of 451, or gable roof with slope between 20° and 45°
Have a mean roof height of 30 feet or less Have a mean roof height of 30 feet or less
FL29444.4: 26 a IM5V on 15132" plywood FL29444.4: 26 a tM5V on 15/32" plywood
Wind 120 130 140 150 160 170 180 190 200 Wind 120 130 140 150 160 170 18AA
Zone 1: A A A A A A A A A Zone 1: A A A A A A A
Zone 2: A A A A A A A A A Zone 2: A AAA A
Zone 3: A A A A A A A AIR Zone 3: A A A
FL29444.4 www.inte-rityMetaisFI.com Page 3