HomeMy WebLinkAboutAPPROVED Underlay Specs WaltonZt D fr' MEMO I etc. U(4 2 Certificate of Authorization #32455 353 Christian Street Unit #13 Oxford, Cr 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT e •s• Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.08-R12 One Owens Corning Parkway FL11602-RII Toledo, OH 43659 Date of Issuance:11/03/2008 (740) 321-6345 Revision 12:12/16/2020 SCOPE: This Evaluation Report is issued under Rule 614520-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 72h Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: Titanium' Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: t y+I L 3�i `• t... iGt Robert J.M. Nleminen P.E.'- Florida Registration No. 59266, Florida DCA ANE2983 • The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12116/2020. This does not serve as an electronically signed document CERTInCATlON OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. @2018 NEMO ETC, LLC installation Requirements and Limitations / Conditions of Use set forth herein. Section Pro a Standard Year 1504.3.1 Wind resistance UL1897 2015 1507.1.1,1507.2.4,1507.2.9.2 / R905.1.1, Material standard ASTM D1970 2015 R905.2.8.2 1507.1.1.1(2&3, Exception),1507.1.1.1(5) / Tear strength ASTM D4533 2015 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception),1507.1.1.1(5) / Tensile strength ASTM D5035 2011 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 TAS 110 Accelerated Weathering ASTM D4798 2011 EntitV Examination Reference Date ERD (TST6049) Various, system tests 135520.06.11 06/15/2011 ERD (TST6049) Wind Uplift 13SS20.08.11-1 08/12/2011 ERD (TST6049) FRSA/TRI, the slippage 4j-OC-19-SSUDL-01.A 06/14/2019 ITS(TST1509) FRSA/TRI, partial 3126617COQ-005 10/31/2007 ITS (TST1509) ASTM D4869, LWT 101823107COQ 007A 12/09/2014 Owens Corning Product equivalency Declaration 06/18/2018 PRI (TSTS878) ASTM D2970 OCF-341-02-01 09/20/2017 PRI (TSTS878) FRSA/TRI, partial OCF-343-02-01 12/09/2017 PRI (TSTS878) ASTM D4798, D1970 OCF-341-02-01 11/27/2017 PRI (TST5878) TAS 117(8); Pull -through OCF-422-02-02 04/03/2018 PRI (TSTS878) FRSA/TRI, partial OCF-425-02-01 08/13/2018 PRI (TSTS878) UL1897 137ST002 07/10/2019 PRI (TSTS878) ASTM D1623, TAS 103 OCF-507-02-01 08/13/2019 PRI(TST5878) UL1897 137ST0117 10/20/2020 PRI(TST5878) ASTM D4533,D4798,D5035 1378T011o 10/15/2020 PRI (TSTS878) ASTM D4533, D4798, DS035 1378T0111 10/15/2020 PRI (TSTS878) ASTM D4533, D4798o D5035 1378TO112 10/15/2020 ITS (QUA1673) Quality Control Service Confirmation 12/09/2020 ITS (QUA1673) Quality Control Florida SCIS Current Product Material Standard Plant(s) Description 4.1 Titanium- PSU-30 ASTM D1970 and Dubai, UAE unreinforced polymer modified bitumen material FRSA/TRI 09-18 Brentwood, NH adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24lbs/square NEMO ETC, LLC Evaluation Report 111980.11.08-R32 Certificoteof AuModzodon #32455 7- EDITION 12020) FBC NON-HVHZ EVALUATION FL11602-R31 Titanium Roof Underfayments Revision 12:12/16/2020 Page 2 of 8 NNEMOletc. Product Material Standard Plant(s) Description 4.2 Titanium- UDL-2S 1507.1.1.1(2&3, Qingdao, China synthetic sheet -type underlayment comprised of Exception), 1507.1. 1.1(5) / a woven core coated on one side with a polymer R905.1.1.1(2&3, coating. Unit weight2.5lbs./square Exception), R905.1.1.1(5) 4.3 Titanium— UDL-30 1507.1.1.1(2&3, Qingdao, China synthetic sheet -type underlayment comprised of Exception),1507.1.1.1(5) / a woven core coated on both sides with a R905.1.1.1(2&3, polymer coating. Unit weight 4.0 lbs./square Exception), R905.1.1.1(5) 4.4 Titanium- UDL-50 1507.1.1.1(2&3, Qingdao, China synthetic sheet -type underlayment comprised of Exception),1507.1.1.1(5) J a woven core coated on both sides with a R905.1.1.1(2&3, polymer coating. Unit weight 4.7 lbs./square Exception), R905.1.1.1(5) 5.1 This is a bu11 1ng code evaluation. Neither NEMO ETC, LlC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami - Dade Counties). 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Titanium— Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS F11CSectlon: 1507.2 2507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 Clay and Concrete Tile Underia ment Y Asphalt Metal Panels SlateorSiate• Wood Shingles and Mechanical Adhesive- Shingles Attach Set and Shingles Type Shingles Shakes Titanium PSU-30 Yes Yes Yes Yes Yes Yes gaintstdps,1507.1.131 (See 5.6.1) R90S.S.L3) Titanium UDL-25 Yes No No Yes Yes No Yes Yes Titanium UDL-30 Yes (Base Sheet to (Base Sheet In Yes Yes No 2-ply system) 2-plysystem) Titanium UDL-50 Yes No No Yes Yes No NEMO ETC, U.0 Evaluation Report 111980AL08-R32 Certykate ofAuthorkatfon k3245S 7" EDITION (2020) FBC NON•HVHZ EVALUATION FL11602-R11 Titanium Roof Underlayments Revision 12:12/16/2020 Page 3 of 8 NNEMOletc. 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS' Underlayment Adhesive Florida Product Approval Dupont "Tile Bond- Roof Tile Adhesive" FL22525 Titanium PSU-30 ICP Adhesives and Sealants "Polyset• AH-160" FL6332 ICP Adhesives and Sealants "Polyset• RTA-1" FL6276 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Substrates (designed to meet wind loads for project) Type Primer:::] Material(s) Titanium PSU-30 self -adhering Deck /sheathing (Optional) ASTM D41 Plywood Base sheet None ASTM D226, Type II felt ASTM o41 Titanium UDL-30 None Titanium UDL-30 (inverted) 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida Nigh Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -45 nsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies Titanium PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. ' Refer to Tile Manufacturer's or Adhesive Manufacturers Florida Product Approvol for Overturning Moment Resistance Performance NEMO ETC, LLC Evaluation Report 111980.11.08-R12 Cer*cate ofAuthorization 0324SS 7"EOITION(2020)FBC NON-HVHZEVALUATION FL11602-1111 Titanium Roof Undedayments Revision 12:12/16/2020 Page 4 of 8 #2 Maximum Design Pressure = -142 5 psf: NNEMOletc. Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Underlayment: One ply Titanium PSU-30, self -adhered and back -nailed max. 6" D.C. with 12 ga. galvanized annular rink shank nails through 32 ga, 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5.8.3.2 Mechanically -Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 2609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for enhancements. #3 Maximum Design Pressure = -30 Dsf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #4 Maximum Design Pressure = -30 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps. Spacing: 6-inch D.C. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. NEMO ETC, LLC Evaluation Report I11980.11.08-R12 Certificate ofAuthorization#32455 7a' EDITION (2020)FBC NON-HVHZEVALUATION FL11602-R31 Titanium Roof Underlayments Revision 12:12/1612020 Page 5 of 8 5.9 #5 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underiayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 96 Maximum Design Pressure =-45 vsf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga.,1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c, at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underiayment: One or two plies, Titanium PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published Installation requirements. Exposure Limitations: TABLE 3: ExposuRE LIMITATIONS nt Prepared Roof Cover installation Type Maximum Exposure (days) Titanium PSU-30 Mechanically attached 180 Adhesive -set the 30 - , Titanium UDL-30, Titanium UDL-50 Mechanically attached 280 NEMO ETC, LLC Evaluation Report 01980.21.08-R12 Certykate ojAuthorizoNon #32455 7' EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R11 Titanium Roof Underlayments Revision 12:12/16/2020 Page 6 of 8 5.10 MEMO ( etc. Tile Slippage Limitations: When loading roof tiles on the underiayment in direct -deck the assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMrrATIONS FOR DIRECT -DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Titanium PSU-30 Flat Max.10-tile stack 5:12 Flat Max 5-tile stack 6:12 Lugged Max.10-tile stack 4:12 Lugged Max. 5-tile stack 5:12 Lugged Max.10-tile stack (S over 5) 5:12 A 6.1 Titanium Roof Undertayments shall be installed in accordance witfi Owens Corning Roofing and Asphalt, !LC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Titanium"' UDL-25, Titanium UDL-30 or Titanium UDL-50: 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FEIC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or 11905.1.1.3. 6.4 1 Titanium"' PSU-30: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underiayment (ASTM D1970) in FBC 2507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type it felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. NEMO ETC, LLC Evaluation Report I11980.11.08-R72 Certifcare ofAuthodzatian #32455 7'" EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R31 Titanium Roof Underiayments Revision 12:12/16/2020 Page 7 of 8 6.4.2 Tile Applications: ONEN10jetc. Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof File Installation Manual, Sixth Edition, and the manufacturer's installation Instructions. Refer to Section 5.8.3 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.5 Titanium2-Ply System: 6.5.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11M-R12 CeWficote of Authorhotion#32455 7" EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R11 Titanium Roof Undedayments Revision 12:12/16/2020 Page 9 of 8