HomeMy WebLinkAboutAPPROVED Snapmax FBCBCIS Home I Log In I User Registration I Hot Topics 1 Submit Surcharge I Stats & Facts I Publications 1 Contact Lis 1 BCI5 Site Map ' Links ' search
F� rida
pr
Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
FL25621-R2
Revision
2020
Approved
Extreme Metal Fabricators, LLC
2160 SW Poma Drive
Palm City, FL 34990
�772] 872-8034
fivalidation@)yahoo.com
Richard McKuhen
flval idation @ya hoo.com
Roofi n g
Metal Roofing
Evaluation Report from a Florida Registered Architect or a
Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
David Eng
PE-81377
Keystone Certifications, Inc.
04/22/2024
James R Wally, PE
Validation Checklist - Hardcopy Received
FL25621 _R2_COI _26ga_S na n Max_p 1ywood . pd f
Standard
Year
TAS 100
1995
TA5 125
2003
UL580
2006
Method 1 Option ❑
12/16/2020
12/17/2020
12/26/2020
02/09/2021
Summary of Products
FL*
Model, Number or Name
Description
25621.1
01: 26ga SnapMax on Plywood
26ga (min) SnapMax 1.0" nail strip on 15/32" (min)
plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL25621_R2_II_26ga_SnapMax _plywood.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.25
Evaluation Reports
Other: Refer to evaluation report
FL25621_R2_AE=26 a_SnapMax_plywood.pdf
Created by Independent Third Party: Yes
25621.2 02: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0"
Plywood nail strip on 15/32" (min) plywood or 3/4" wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621_R2_II_032_SnapMax_plywood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-78.5 Evaluation Reports
Other: Refer to evaluation report FL25621_R2_AE_032_SnapMax_plywood.pdf
Created by Independent Third Party: Yes
25621.3 03: 032 Aluminum 12" SnapMax Nominally 0.032" aluminum (or thicker) SnapMax 1.0"
on Plywood nail strip with 12" coverage on 15/32" (min) plywood or
3/4" wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621_R2_II_032_SnapMax _12in_Plywood.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-69.25 Evaluation Reports
Other: Refer to evaluation report FL25621_R2_AE_032_SnapMax_12in_P1ywood.pdf
Created by Independent Third Party: Yes
25621.4 04: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min)
plywood or 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621_R2_II_26ga_SnapMax_plywood_D.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-121.75 Evaluation Reports
Other: Refer to evaluation report FL25621_R2_AE_26ga_SnapMax_plywood_D.pdf
Created by Independent Third Party: Yes
25621.5 05: 26ga SnapMax on Plywood 26ga (min) SnapMax 1.0" nail strip on 15/32" (min)
HVHZ plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL25621_R2_II_26ga_SnapMax_plywood_HVHZ.pdf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-176
Evaluation Reports
Other: Refer to evaluation report
FL25621_R2_AE_26ga_SnapMax_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.6 06: 24ga SnapMax on Plywood
24ga (min) SnapMax 1.0" nail strip on 15/32" (min)
plywood or 3/4" (min) wood plank
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL25621_R2_II_24ga_SnapMax _plywood.odf
Approved for use outside HVHZ: Yes
Verified By: David Eng, PE 81377
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-206
Evaluation Reports
Other: Refer to evaluation report
FL25621_R2_AE_24ga_SnapMax _plywood.pdf
Created by Independent Third Party: Yes
25621.7
07: 032 Aluminum SnapMax on
Nominally 0.032" aluminum (or thicker) SnapMax 1.0"
Plywood
nail strip on 15/32" (min) plywood or 3/4" wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621_R2_1I_032_SnapMax_plywood_d.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5 Evaluation Reports
Other: Refer to evaluation report FL25621_R2_AE_032_SnapMax _plywood_d�df
Created by Independent Third Party: Yes
25621.8 08: 032 Aluminum SnapMax on Nominally 0.032" aluminum (or thicker) SnapMax 1.0"
Plywood HVHZ nail strip on 15/32" (min) plywood or 3/4" wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL25621_R2_II_032_SnapMax_plywood_HVHZ.pdf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-175 Evaluation Reports
Other: Refer to evaluation report FL25621_R2_AE_032_SnapMax_plywood_HVHZ.pdf
Created by Independent Third Party: Yes
25621.9
09: 26ga 19" TopMax on Plywood
26ga (min) TopMax IS' nail strip with 19" coverage on
15/32" (min) plywood or 3/4" (min) wood plank
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL25621_R2_II_26ga_TopMax_19in_plymod.ndf
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-63.5 Evaluation Reports
Other: Refer to evaluation report FL25621_R2_AE_226ta_TopMax_19in_plywood.pdf
Created by Independent Third Party: Yes
25621.10 1 • " aluminum for thicker) TopMax 1.5" nail
01yW000 HVHZ strip on 15/32" (min) plywood or 3/4" wood plank