Loading...
HomeMy WebLinkAboutProduct Approval (3) MIMIAMI- MIAMI-DARE COUNTY UNUM PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474 T(786)315-2590 F(786)315-2599 NOTICE OF ACCEPTANCE (NOA) www•niiamidade.gov/sera Crown Building Products of Florida LLC 6018 HWY 72 Arcadia,FL.34266 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section (in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this product or material tested for quality assurance purposes.If this product or material fails to perform in the accepted manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein,and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Tuscany Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city,state and following statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product, for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then it shall be done in its entirety. INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 14-1006.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Freddy Semino — � NOA No.:19-1003.02 CMIAMAD LINTY Expiration Date:01/29/25 Approval Date:11/28/19 Page 1 of 7 i r ROOFING ASSEMBLY APPROVAL Category Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Tuscany Roof Tile manufactured by Crown Building Products of Florida LLC in Arcadia,Fl.as described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements,as determined by applicable Building Code does not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Crown Tuscany Roof Tile L= 17.0" TAS 112 Low profile interlocking,concrete roof tile. For W= 13.0" Type—lb direct deck,batten nail-on,mortar or adhesive set 0.50"thick nominal Class III applications 2.3"high Trim Pieces Length:varies TAS 112 Accessory trim,concrete roof pieces for use at Width:varies hips,rakes,ridges and valley terminations varying thickness manufactured for each tile profile. 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) ICP Adhesives Polyset AH-160 Two component polyurethane ICP Adhesives and Sealants,Inc. foam adhesive. TILE BOND'Roof Tile Adhesive Single component polyurethane The Dow Chemical Company foam roof file adhesive. "Tile Tite"Roof Tile Mortar Premixed,pre-bagged roof tile Bermuda Roof Co.Inc. mortar. Bonsai Roof Tile Mortar Premixed,pre-bagged roof tile Bonsai American mortar. "Quikrete"Roof Tile Mortar,FL-15 Premixed,pre-bagged gray roof The Quiluete Companies,Inc. tile mortar. NOA No.:19-1003.02 MIAMMADE COUNTY ...� � Expiration Date:01/29/25 Approval Date:11/28/19 Page 2 of 7 1 • 2.2 MANUFACTURING LOCATION 2.2.1. Arcadia,Fl. 2.3 SUBMITTED EVIDENCE: Test Agency Test Identifier Test Name/Report Date Redland Technologies 7161-03 Appendix III PA 102&PA 102(A) Dec. 1991 Letter PA 108(Nail-On) Aug. 1994 P0631.01 PA 108(Mortar Set) July 1994 P0402 Withdrawal Resistance Testing of screw Sept. 1993 vs. smooth shank nails The Center for Applied 94-083 PA 101 (Adhesive Set) April 1994 Engineering,Inc. 94-084 PA 101 (Mortar Set) May 1994 25-7094-(1,4&7) PA 102 Oct. 1994 25-7183-(1,2&7) PA 102 Nov. 1994 25-7214-(2&6) PA 102 Feb. 1995 25-7487-(1) PA 102 March, 1995 25-7496(2&3) PA 102 Sep. 1996 25-7804-5 Celotex Corporation 528454-2-1 PA 101 Sept. 1998 Testing Services 520109-2 PA 101 December 1998 Walker Engineering,Inc. Calculations 25-7094 February 1996 Calculations 25-7496 April-1-996 Calculations 25- 594 December 1996 Calculations— 25-7804b-8 December 1996 Calculations 25-7804-4&5 December 1996 Calculations 25-7848-6 December 1996 Calculations 25-7183 March 1995 Evaluation Calculations Aerodynamic Multiplier April 1999 Evaluation Calculations Two Paddy Adhesive Set System April 1999 American Test Lab of South RT0908.02-14 TAS 112 09/18/14 Florida RT0912.02-14 Restoring Moment Aerodynamic Multiplier 09/18/14 RT1021.01-15 TAS112 12/10/15 RT1211.01-15 Restoring Moment 12/11/15 RT1211.01-15 Aerodynamic Multiplier 12/11/15 RT1203.02-18 TAS 112 12/11/18 RT0531.02-19 TAS 112 05/31/19 GMMIAMH�MDE COUNTY NOA No.:19-1003.02 . . Expiration Date:01/29/25 Approval Date: 11/28/19 Page 3 of 7 3. UmTATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications,a static field uplift test in accordance with TAS 106 may required,refer to applicable building code. 3.3 Applicant shall retain the services of a Miami-Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112,appendix`A'.Such testing shall be submitted to the Building and Neighborhood Compliance Department—Product Control Section for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 4/12 Minimum slope for mechanically attached tiles. 3.6 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.7 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Crown Tuscany Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118,RAS 119,and RAS 120. 4.2 Data For Attachment Calculations. Table 1: Average Weight(W) and Dimensions (I x w) Tile Profile Weight-W(lbf) Length-1 (ft) Width-w (ft) Tuscany Crown Roof Tile 10.0 1.42 1.08 Table 2: Aerodynamic Multipliers -A(ft3) Tile A(ft3) A(ft3) Profile Batten Application Direct Deck Application Tuscany Crown Roof Tile 0.289 0.313 Table 3: Restoring Moments due to Gravity-M9(ft.-lbf) Tile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or Profile greater Tuscany Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Crown Deck Deck Deck Deck Deck Deck Roof Tile N/A 7.06 N/A 6.99 6.88 6.88 6.73 6.74 6.57 6.57 6.39 6.39 NOA No.:19-1003.02 MLAMwaoeCouNnr Expiration Date:01/29/25 Approval Date:11/28/19 Page 4 of 7 ill . Table 4: Attachment Resistance Expressed as a Moment -Mr(ft.-Ibf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15132" (min. 19/32" plywood) plywood) Tuscany Crown Roof 2-10d Ring Shank Nails 27.8 37.4 28.8 Tile 1-10d Smooth or Screw Shank 8.8 11.8 4.1 Nail 2-10d Smooth or Screw Shank 16.4 21.9 7.1 Nails 1 #8 Screw 25.8 25.8 22.9 2#8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw Shank 24.3 24.3 24.2 Nail Field Clip) 1-10d Smooth or Screw Shank 19.0 19.0 22.1 Nail Eave Clip) 2-10d Smooth or Screw Shank 35.5 35.5 34.8 Nails Field Clip) 2-10d Smooth or Screw Shank 31.9 31.9 32.2 Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment -Mf(ft.-Ibf) for Mechanically Attached Systems Tile Fastener Type Direct Deck Direct Deck Battens Profile (min 15/32" (min. 19132" plywood) plywood) Tuscany Crown Roof 2-10d Ring Shank Nails' 43.0 67.5 50.9 Tile 1 Installation with a 4"the headlap and fasteners are located a min.of 2'/2"from head of tile. Table 6: Attachment Resistance Expressed as a Moment Mf(ft.-Ibf) for Two Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Tuscany Crown Roof Adhesive' 26.12 Tile 1 See manufactures component approval for installation requirements. 2 TILE BONDTM Roof Tile Adhesive;Average weight per patty 11.4 grams. ICP Adhesives and Sealants, Inc.'s ICP Adhesives Pol set AH-160;Average weight per patty 8 grams. NOA No.:19-1003.02 MUWWAoeeoutvW Expiration Date:01/29/25 Approval Date: 11/28/19 Page 5 of 7 Table 7: Attachment Resistance Expressed as a Moment-Mf(ft-lbf) for Single Patty Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Tuscany Crown Roof ICP Adhesives Pol set AH-160 86.613 Tile ICP Adhesives Pol set AH-160 45.54 3 Large paddy placement of 54 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Pol set AH-160. 4 Medium paddy placement of 24 grams of ICP Adhesives and Sealants, Inc.'s ICP Adhesives Pol set AH-160. Table 8:Attachment Resistance Expressed as a Moment -Mf(ft.-Ibf) for Mortar Set Systems Tile Tile Attachment Profile Application Resistance Tuscany Crown Roof Mortar Sets 20.6 Tile 5 Seespecific mortar manufacturers Notice of Acceptance 5. LABELING 5.1 All tiles shall bear the imprint.or identifiable marldng of the manufacturer's name or logo as detailed below,or following statement: "Miami-Dade County Product Control Approved". 1 i --i IJk ... ---.--- - - --. ---- I'AA-1 e:�1 I I , F ' I LABEL FOR CROWN TUSCANY ROOF TILE (LOCATED ON THE UNDERSIDE OF TILE NOA No.:19-1003.02 M AMIDADe CoutM Expiration Date:01/29/25 Approval Date:11/28/19 Page 6 of 7 6. BUILDING PERMIT REQuiimmENTs: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWING TUSCANY Ftv?FfI`d;R HOLE c i f 17" 1311 { CROWN TUSCANY ROOF TILE END OF THIS ACCEPTANCE NOA No.:19-1003.02 MIAMEDADE COUNTY Expiration Date:01/29/25 Approval Date:11/28/19 Page 7 of 7