Loading...
HomeMy WebLinkAboutDemo Improve Plan (1)RECEPTION/WAITINGCLASSROOMCLASSROOMCLASSROOMCLASSROOMENTRY LOBBYRESTOOMSVESTIBULEMENWOMENJANITORAHUAHUMAIL/COPY/WORK AREABREAK ROOMEXECUTIVE DIRECTORACADEMY DEANOFFICETHERAPYCENTER ROOMCENTER ROOMCENTER ROOMCENTER ROOMOCTAGONITREFRIGSINKD/WW/DCORRIDORCORRIDORCORRIDOR/EXIT WAYSTORAGESTORAGESTUDENTSMALESTUDENTSFEMALEFACULTY/STAFFEXISTING ELECTRICALPANELS, ETC.EXISTING FIRESTANDPIPE,SERVICE270102030405071817160822131409111223212024252639 3637384042433231302928CORRIDOR 19 CORRIDOR CORRIDOR/EXIT WAY06 CORRIDOR 10CORRIDOR15CORRIDOR34CORRIDOR 35CORRIDOR AHUSTORAGE41010203040506071716081514120910111825190120212322262927283031323340343539383736241312'-8"4"4'-0"4"4'-0"4"12'-4"4"5'-0"4"26'-0"4"6'-8"4"26'-0"4"16'-0"4"4'-0"4"5'-0"4"13'-4"13'-4"6'-6"4"6'-6"4"4'-0"4"11'-8"4"4'-0"4"5'-0"4"26'-0"4"6'-8"4"26'-0"4"5'-6"6"5'-6"4"8'-6"4"5'-0"4"4'-2"26'-4"4"13'-4"8'-2"4"8'-0"4"10'-0"4"11'-6" 8'-2"4"7'-2"4"5'-10"4"8'-0"4"8'-2" 24'-8"4"6'-8"4"24'-8" 24'-8"4"6'-8"4"24'-8"3'-0"3'-0"4"8"TYPICALEACHCORNERRECEPTIONIST41OUTSIDE LOGGIATO BE SCREENEDENCLOSEDOUTSIDE LOGGIATO BE SCREENEDENCLOSEDEXISTING ELECTRICALPANELS, ETC.EXISTING FIRESTANDPIPE,SERVICEAREAS OFDEMOLITIONDEMOLITION NOTES:1.THIS DEMOLITION PLANSHOWS GRAPHIC ANDWRITTEN INFORMATIONCONCERNING THE EXISTINGSPACE. THIS IS INCLUDED AS"INFORMATION ONLY"REPRESENTING AVAILABLERECORD INFORMATION OFTHE ORIGINAL LEASEDRAWINGS PLUS FIELDNOTATIONS. SOMEMODIFICATIONS MAY HAVEBEEN MADE AND NOTSHOWN. THIS INFORMATIONIS FOR THE CONTRACTOR'SREFERENCE AS MAY BEUSEFUL.2.CONTRACTOR SHALL FIELDVERIFY ALL EXISTINGCONDITIONS ANDDETERMINE THE SCOPE OFWORK REQUIRED.3.THE CONTRACTOR SHALLEXAMINE THE EXISTINGBUILDING AND WORKSHOWN BY ALL CONTRACTDOCUMENTS TO DETERMINETHE SCOPE OF DEMOLITIONREQUIRED WHETHERSPECIFICALLY SHOWN ORNOT.4.REFER TO MEP DOCUMENTSFOR EXTENT OF DEMOLITIONOF THOSE SYSTEMS.5.PROTECT ALL EXISTINGSTRUCTURE, SYSTEMS,FINISHES AND GENERALCONSTRUCTION THAT ARETO REMAIN THROUGHOUTTHE COURSE OF THE WORKTO PREVENT DAMAGE ORLOSS.6.CONTRACTOR IS TO VERIFYUTILITY LINE LOCATIONSAND MAINTAIN THOSE THATSERVE OTHER PARTS OF THEBUILDING THAT ARE NOTAFFECTED BY THEDEMOLITION.7.ALL WORK WILL BEPERFORMED IN THE BESTWORKMANSHIP POSSIBLE INACCORDANCE WITH THATTRADE'S BEST INDUSTRYSTANDARDS.8.NOISE AND DUST IS NOT TOBE DISRUPTIVE TO THEOCCUPIED AREA OF THEBUILDING. PROVIDETEMPORARY PARTITIONS ASREQUIRED.9.DEMOLITION IS TO BE DONEIN A CAREFUL ANDORDERLY MANNER SO ASNOT TO DAMAGE FINISHESOR EQUIPMENT TO REMAIN.04.11.2021OWNER DESIGN REVIEWAAS NOTEDPWJPWJA-1Peter W. Jones, AIA140 NW Pleasant Grove WayPort St. Lucie, Florida 34986T: 772.559.4714E: pwjconsult@gmail.comAR0017858Project No.:Drawn:Checked:Scale:Sheet No.:Issue Date:Drawing Title:Project:Issues:Date:Description:General Contractor:Peter W. JonesAR0017858DateNo.:Keyplan:= Area of ImprovementsTHE ATTACHED PLANS HAVE BEEN DESIGNED FOR AND AREIN COMPLIANCE WITH THE 7TH EDITIONS OF THE FLORIDABUILDING CODE AND FLORIDA FIRE PREVENTION CODE.DESIGN IS SITE SPECIFIC AND NOT VALID WITHOUT THEAUTHORIZED SIGNATURE AND SEAL OF A REGISTEREDARCHITECT. THESE NOTES ARE PART OF THECONSTRUCTION DOCUMENTS. DO NOT SCALE THESEDRAWINGS, USE FIGURED DIMENSIONS ONLY. IF ADISCREPANCY OCCURS, CONTACT THE ARCHITECT FORCLARIFICATIONS.THESE DOCUMENTS TO WHICH I HAVE AFFIXED MYSIGNATURE AND SEAL WERE PREPARED BY ME AND/ORUNDER MY DIRECT SUPERVISION. THESE DOCUMENTS AREINSTRUMENTS OF USE AND ARE PROTECTED BY THECOPYRIGHT LAW OF THE U.S. THEY MAY NOT BEREPRODUCED IN WHOLE OR PART WITHOUT WRITTENPERMISSION OF THE ARCHITECT.8555 SW Commerce CentreBaron AcademyPort St. Lucie, Florida08.01.20203/16" = 1'-0"Proposed Improvements PlanProposed DemolitionIMPROVEMENTS PLAN3/32" = 1'-0"