HomeMy WebLinkAboutGuba gas regulator specs 1 22H, R222H, R222, R232A and R232E Series LP-Gas egulators VENT POINTED DOWN �•�m _ 71r r} T14446-A2 Figure 2.Regulator with Vent Pointed Down Table 1. Relief Valve Specifications TYPICAL SETPOINT NOMINAL RELIEF VALVE MAXIMUM OUTLET PRESSURE WITH DISC REMOVED START-TO-DISCHARGE TYPE Inlet Pressure Maximum Outlet Pressure psi bar psi bar psig bar psig bar R122H 10 0.69 16 1.10 250 17.2 Not Applicable 5 0.35 9 0.62 R222H 10 0.69 16 1.10 250 17.2 Not Applicable R222 11 in.w.c. 27 mbar 1 0.07 30 2.07 2.0 0.14 R232At1) 11 in.w.c. 27 mbar 1 0.07 2.0 0.14 250 17.2 R232110) 2 0.14 3.5 0.24 5.0 0.35 1.For integral two-stage regulators,the second stage disc is removed. Table 2. Capacity, Connection Sizes and Vent Orientation _ REGULATOR TYPE CAPACITY INLET OUTLET OUTLET 3/8 IN.FNPT SCREENED VENT APPLICATION NUMBER BTU/HR CONNECTION CONNECTION PRESSURE STANDARD LOCATION PROPANEM SETTING First Stage R122H-AAJ 1,100,000 1/4 in.FNPT 1/2 in.FNPT 10 psig/0.69 bar Over Outlet') R222H-BGK 1,700,000 1/2 in.FNPT 1/2 in.FNPT R222H-DGK 2,000,000 3/4 in.FNPT 3/4 in.FNPT / R222H-HGK 1,700,000 FPOL 1!2 in.FNPT 5 psig 0.35 bar R222H-JGK 1,875,000 FPOL 3/4 in.FNPT First Stage Over Outlet R222H-BGJ 1,800,000 1/2 in.FNPT 1/2 in.FNPT R222H-DGJ 2,000,000 3/4 in.FNPT 3/4 in.FNPT ( R222H-HGJ 1,800,000 FPOL 1/2 in.FNPT 10 psig 0.69 bar R222H-JGJ 1,875,000 FPOL 3/4 in.FNPT R222-BAF Over Inlet Second Stage 650,000 1/2 in.FNPT 1/2 in.FNPT R222-BAFXA Over Outlet R232A-BBF 550,000 1/2 in.FNPT 1/4 in.FNPT 11 in.w.c./ First Stage(3):Down Integral R232A-HBF FPOL 27 mbar Second Stage:Over Outlet Two-Stage R232A-BBFXA 550,000 1/2 in.FNPT 1/4 in.FNPT First Stage:Opposite Gauge Taps R232A-HBFXA FPOL Second Stage:Opposite Gauge Taps Integral Two psig R232E-BBH 1/4 in.FNPT First Staget3):Down Service 500,000 1/2 in.FNPT 2 psig/0.14 bar R232E-HBH FPOL Second Stage:Over Outlet 1.Capacities Based on: Second Stage:10 psig/0.69 bar with 2 in.w.c./5 mbar droop. Integral Two Stage:30 psig/2.07 bar and 2 in.w.c./5 mbar droop. Integral Two psig Service Regulator:30 psig/2.07 bar inlet pressure and 20%droop. First Stage:30 psig/2.07 bar inlet pressure and 20%droop. 2.Also available with vent apposite gauge taps. 3.Integral First Stage Vent size:7/16-24 UN thread for 1/4 in.OD copper tube inverted flare fitting. 3 andRegulators Table 2. Capacity, Connection Sizes, and Vent Orientation CAPACITY OUTLET 3/4-INCH NPT REGULATOR TYPE BTU/HR INLET OUTLET PRESSURE SCREENED APPLICATION NUMBER PROP ViR CONNECTION CONNECTION SETTING VENT STANDARD LOCATION R622-BCF 875,000 1/2-inch FNPT 1/2-inch FNPT R642-DFF 900,000 3/4-inch FNPT '11 inches w.c./ R652-DFF 1,000,000 27 mbar 3/4-inch FNPT R622-CFF 1/2-inch FNPT Second P.622-DFF 3/4-inch FNPT Stage 1,400,000 Over Inlet R622-CFGXA 1,125,000 1/2-inch FNPT 18 inches w.c./ 3/4-inch FNPT 45 mbar HSRL-BFCtzI 3/4-inch FNPT 11 inches w.c./ 2,100,000 27 mbar HSRL-CFCtzI 1-inch FNPT 1-inch FNPT R632A-BCF 850,000 1/2-inch FNPT 114-inch FNPT First Stage(`):R632A-I-ICF FPOL 11 inches w.c.! Down R632A-CFF 950,000 114-inch FNPT 27 mbar Second Stage: 3/4-inch FNPT Over Outlet Integral R632A-JFF 850,000 FPOL Two-Stage R632A-BCFXA 114-inch FNPT t,t. 850,000 1/2-inch FNPT First Stage R632A-HCFXA FPOL 11 inches w.c/ Opposite gauge taps R632A-CFFXA 950,000 1/4-inch FNPT 27 mbar Second Stage: R632A-JFFY.A 850,000 FPOL 3/4-inch FNPT Opposite gauge taps R632E-BCH 850,000 1/4-inch FNPT First Stage('): Integral 1/2-inch FNPT Down 9 R632E-HCH 900,000 FPOL 2 psig/0.14 bar 2 psig/0.14 bar Service R632E-CFH 1/4-inch FNPT Second Stage: R632E-JFH 850,000 FPOL 3/4-inch FNPT Over Outlet R622E-BCH 1,250,000 1/2-inch FNPT 1/2-inch FNPT 2 psig/0.14 bar R622E-DCH 1.500.000 2 psig/0.14 bar Ovgr Inlet Service 3/4-inch FNPT 314-inch FNPT R652E-DFH 1,400,000 R622H-BGK 2,000,000 1/2-inch FNPT 5 psig/0.35 bar R622H-BGJ 1/2-inch FNPT R622FI-HGJ 2.100,000 10 psig/0.69 bar First Stage R622Fl-1-IGJKA FPOL Over Outlet R622H-JGI< 5 psig/0.35 bar 2,250,000 R622H-JGJ 3/4-inch FNPT 10 psig/0.69 bar R622H-DGJ 2,400,000 3/4-inch FNPT 1. Capacities Based on: Second Stage:10 psig/0.69 bar inlet pressure and 2 inches w.c./5 mbar droop. Integral Two-stage:30 psig 12.1 bar and 2 inches w.c./5 mbar droop. Integral Two psig Service:30 psig/2.07 bar and 20%droop. 2 psig/0,14 bar Service:10 psig/0.69 bar inlet pressure and 20%droop. First Stage:30 psig/2.1 bar inlet pressure and 20%droop. 2. Straight globe valve body configuration. 3. Integral First Stage Vent size:7/16-24 UN thread for 1/4-inch OD copper tube inverted flare fitting. Replace old pigtails. Blow out any debris,dirt or copper Installation Location sulfate in the copper tubing and the pipeline. ® Apply pipe compound to the male threads of the pipe ® The installed regulator should be adequately before installing the regulator. protected from vehicular traffic and damage from other external sources. Make sure gas flow through the regulator is in the same direction as the arrow on the body. "inlet"and"Outlet" a Install the regulator with the vent pointed vertically connections are clearly marked. down, see Figure 2. If the vent cannot be installed in a vertically down position,the regulator must be installed under a separate protective cover. Installing 4