Loading...
HomeMy WebLinkAboutPermit Worksheet (Corrected)c ecAe erm d Q nni RECEIVED O� PERMIT WORKSHEET FELT -' 3 1011 page 1 of 2 >` �te� PERMIT NUMBER 014WOV16 permitting Department 1 0� New Home. Used Home St. IIJ County installer License # 1 ,J Home installed to the Manufacturer's installation Manual Address of home / (A being installed Manufacturer 0 Length x width '� x 1� NOTE. if home is a single wide rill out'one half of the blocking plan if home is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home (new or where the sidewall ties exceed 5 ft-4 in. - Installer's initials Typical pier spacing I lateral 9' Show locations of Longitudinal and Lateral Systems ---Dlonglludinal (use dark lines to show these locations) - I...0...---------------------------------------------------------------- ---------------------------..,1--- marriage wall piers within 7 of end of home per Rule ISC �._._ ;..... I i i�� i i.....; I } _... ...... .......... .I.... -I....: �.... �......� . i i ... ... .- ..............._...._..... I ... f.....I.._.. ..... ................ .............. . . --- :..1.......... ......:..... [.......... ......,..... i.......... l.._.l.....{.....;.....I.....i.....i....i.....[.....i.....'.. ........... ....�....... ........ ..... I .......... ....�.....�.....i.....{.....i. - j..............{{ ...I.... ...I.....i..... %.... ...1....... ............ [ ....... . ... .....,....:.....j.......... .....i.....L....l.....;.... r •.._...... T..... ..... ..... .....i._... [....�..... . t t.... ; �.....� i !.. i ......,.._ .:.........:.....:.....:.....a......,.... I I {.....,.....i.....,........ ------ I Home PIER SPACING TABLE FOR USED HOMES µ Load bearing capacity Footer size (sq In) 16" x 16" (256) 18 1/2" x 18 1/2" (342) 20" x 20" (400) 22" x 22" (484)' 24" X 24" (576)' 26" x 26" (676) 00 ps 315,8 00 osf 6 7 8 000 s 6 8 8 8 2500 s 6 8-- 8 8 3000 Pst 8- 81 8 3500 pst 8 8 • •8 interpolated from Rule 15C-1 pier spacing table. PIER PAD SIZES e I-beam pier pad size Perimeter pier pad size Other pier pad sizes - (required by the mfg. ) PUPUEAR PAD SIZE 4., Draw the approximate locations of marriage wall openings 4 foot or greater. Use this symbol, o, show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. x ANCHORS 4ft 5ft [- FRAME TIES within 2' of end of home spaced at 5' 4" oc TIEDOWN COMPONENTS OTHER TIES Number Longitudinal Sabi izi device LSD Sidewall Manufacturer ��ngitudinal — Lonaitudinal Saril izina Device w L eral Arms rriRae wall Opening Pier pad size AI' RECEIVED PERMIT NUMBER JAN 0 7 2020 St. LuLLntPOCKET PE ETROMETER TEST The pocket penetrometer tests are rounded down to - psf or check here to declare 1000 lb. soil without testing, X X X POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the footer. - - 3. Using 500 lb. increments, take the lowest reading and round down to that increment. X X TORQ E PROBE TEST The results of the torque probe test is 2�. inch pounds or check here if you are declaring 5' anchors without testing . . A test. showing 275 Inch pounds or less will require 4 foot anchors. PERMIT WORKSHEET Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed at the sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile hpme manufacturer may requires anchors with 400h ing capacity. CC�� �` installer's initials ALL TESTS MUST BE PERF IVIED BY tLIC1ENSED INSTALLER Installer Name Date Tested Electrical Connect electrical conductors between multi -wide units, but not to the ma' ower source. This includes the bonding wire between mutt -wide units. Pg. page 2 of 2 Site Preparation Debris and organic material removed Water drainage: Natural Swale Pad Other C i Fastening multi wide units Floor: Type Fastener. Le gth: .S in Walls: Type Fastener: p in Roof: Type Fastener FV��� For used homes a m"3gae, a" wide, galvanized metal strip will be centered over the roof and fastened with gals. roofing nails at 2" on center on both sides of the centerline. Gasket iwealherproollnq requirement) I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. ataller Type gasket ta". Pg. Between Floors Yes Between Walls Yes Bottom of ridgebeam Yes Weatherproofing The bottomboard will be repaired and/or taped. Yes Pg. Siding on units is installed to manufacturer's specifications. Yes Fireplace chimney installed so as not to allow Intrusion of rain water. Yes Miscellaneous Skirting to be installed. Yes _le!� No Dryer vent installed outside of skirting. Yes t/ N/A Range downflow vent Installed outside of skirting. Yes L.-I —N/A Drain lines supported at 4 foot intervals. Y Electrical crossovers protected. Yes Other: Installer verifies all information given with this permit worksheet Is accurate and true based on the Connect all sewer drains to an existing sewer tap or septic tank. Pg. f�,,.... + .11 .,. MWa Minfor -zi innly nininn to an existino water meter, water tap, or other Installer Date .= 1'� /