Loading...
HomeMy WebLinkAboutRoof info sheetST. LUCIE WORKS ST LUCIF COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Budding Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Low Slope Application Prescriptive BUR-RAS 150 Asphaltic Shingles Concrete or Clay Tile Metal Roofs Wood Shingles and Shakes Other 2. Required Sections of the Permit Application Form A,B,C A, B, C Attachments Required See List Below 1,2,3,4,5,6,7 2,4,5,6,7 A, B, D 1,2,4,5,617 A, B, D, E J Z3,4,5,6,7_ A, B, D A, B, D 1,2,4,5,6,7 As Applicable 1A3,4ASS 7 ATTACHMENTS REQUIRED As Applicable): Fire Directory Listing Page From Product Approval - Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 1 -- A 4. Other Component of Product Approval 5. ' Municipal Permit Application 6. ' Owners Notification for Roofing Considerations (Reroofin€ 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS SeClan.A (General Information) Master Permit No. Process No. i n L Contractors Name: �\n License # 1 lJl (�1 �'T Job Address '_H 'S k�E (D `_ean6 r U ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles *Asphaltic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes Prescriptive BUR-RAS 150 ROOF ROOF TYPE ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) /070b Total (SF)I e14� Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (if a component is not used, identify as "NA") System Manufacturer Product Approval No.: Design Wind Pressures, From RAS 128 or Calculations: Zone 1'. Zone I: Max. Design Pressure, system: Deck: Type: Gauge Thickness: Slope: Zone 2: Zone 3. orn the specific product approval Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding MaVrfal: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding M Top Insulation Layer: Top Insulation Size and Thickneis: Top Insulation Fastener/Bonc(ng Material: Base Sheet(s) & No. of Plyt): Base Sheet Fastener/Bor/ding Material. - Ply Sheet(s)' & No. of Ply(s)- Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment, Zone 1':__ _" oc @ Lap, # Rows @ " OC Zone 1: " oc @ Lap, # ows @ " oc Zone 2: " oc: Vap, Rows @ " oc Zone 3: " oc # Rows @ " oc Number of F Zone 1' ners Per Insulation Board Zone 1: Zone 2• Zone 3: Illust to Components Noted and Details as Applicable W cbdblocking, Gutter, Edge Termination, Stripping, ashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. FT. FT. -a Parapet Height Mean Roof Height ST. LUCIE WORKS Section D Steep Slope Roof System) Roof System Manufacturer Notice of Acceptance Number- F-L - A9 1,)-L� - �2,�-5 Minimum Design Wind Pressures, if Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r: Roof Slope: 12 Ridge Ventilation? A�IA Mean Roof Height: QeckTpe:. S�� ?/Cyr Type Underiayment: Insulation: Fire Barrier" Fastener Type & Spacing: i Adhesive Type: 11 Type Cap Sheet: T i Roof Covering: 64 Type & Size Drip `� Edge: ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mf values are greater than or equal to the Mr values, for each area of the roof, then the the attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12 (Zone x ?. = � — Mg: = Mr, Product Ap roval Mi (Zone 2e: x X ) — Mg: = M"$ Produc Approval Mf (Zone 2n: x — i)-1tl{g: = Mom, Pro ci Approval Ma (Zone 2r: x ? _ _—Mg: ='Mezr Pr duct Approval Mr (Zone 3e: _____ —Mg: =Mrs, _ _ roduct Approval Mf (Zone 3r: ) —'Mg: = M, Product Approval Mt ethod 2 "Simplified Tile Calcui.itio s Per Table Below" Required Moment of Resistance (Mr) rom Table Below —Pro ct Approval Mt Mean Roof Height Roof Slope 2:12 3:12 4:12 required Moment Resis nce* 15 20' 1 2 5 34.4 \ 1 36.5 32.2 34.4 30.4 32.2 �.. 5:12 28.4 6:12 26.4 7:12 24.4 *Must be used in conjunction with a list of r • For Uplift based tile systems use Method 3 equal to the Fr values, for each area of the r Method (Zone 1: x L =x W:=�� (Zone 2e: x L =x W:=_ (Zone 2n: x L _=x W:= (Zone 2r: x L =x W:= (Zone 3e: x L =x W:= (Zone 3r: x L =x W:= Description Design Pressure Mean Roof Height Roof Slope Aerodynamic Multiplier Restoring Moment due to 30.1 38.2 36.0 K 31.6 29.4 271 30' 39.7 37.4 35.1 OX-13 30.5 28.2 40' 42.2 39.8 37.3 34.9 32.4 0111] Tom nt b\the'e e systems C mparlues for F' with the values for F If the F' values are greater than or f, thenattachment method is acceptable. 3 "Uplift lie Calculations Per RAS 12T cos rN=F Product Approval F -W: cos Product Approval F' -W: cos Product Approval F' -W: cos Product Approval F'-W: cos Product Approval F' -W: cos Product Approval F' Where to Obtain Information Symbol Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table prepared by PE based Job Site Job Site Product Approval Product Approval Attachment Resistance J Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. Where to find RAS 127 or by an engineering analysis ASCE 7