HomeMy WebLinkAboutEnergy CodeV
�f
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 38 Block 2 Waterstone 2508 CRGR Builder Name:' ADAMS HOMES
Street: 8521 Waterstone Boulevard Permit Office:
City, State, Zip: Fort Pierce , FL , 34951 Permit Number:
Owner: Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans) 10. Wall TypeV020.7 sgft.) Insulation Area
2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1748.70 ftz
b. Frame - Wood, Adjacent R=13.0 272.00 ftz
3. Number of units, if multiple family 1 c. N/A R= ftZ
4. Number of Bedrooms 4 d. N/A R= ftz
5. Is this a worst case? No 11. Ceiling Types (2603.0 sgft.) Insulation Area
a. Under Attic (Vented) R=30.0 2523.00 ftz
6. Conditioned floor area above grade (ftz) 2523 b. Knee Wall (Vented) R=19.0 80.00 ftz
Conditioned floor area below grade (ftz) 0 c. N/A R= ftz
7. Windows(293'.4 sgft.) Description Area 12. Ducts R ftz
a. U-Factor: Dbl', U=0.33 166.06 ftz a. Sup: Attic, Ret: Main, AH: Main 6 503.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 70.92 ftz 13. Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.21 a. Central Unit 42.0 SEER:15.00
c. U-Factor: Dbl, U=0.55 35.56 ftz
SHGC: SHGC=0.70
Area Weighted Average Overhang Depth: 6.223 ft. 14. Heating systems kBtu/hr Efficiency
Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 42.0 HSPF:8.50
8: Skylights Area
c. U-Factor:(AVG) N/A ftz 15. Hot water systems
SHGC(AVG): N/A a. Electric Cap: 40 gallons
9. Floor Types "(2523.0 sqft.) Insulation Area EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2523.00 ftz b. Conservation features
b. N/A R= ftz None
c. N/A R= ftz 16. Credits Pstat
Glass/Floor Area: 0.116 Total Proposed Modified Loads: 71.31 PASS
Total Baseline Loads: 71.58
I hereby certify that the plans a p ations covered b e of the plans and O.d�HB Sr
this calculation are in compliauf the Florida specifications covered by this _� _ �Z"
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE. n9-n4-2091 Ann Kenmany this building will be inspected for : , a
compliance with Section 553.908 yf`
I hereby.certify that this building, as designed, is in compliance Florida Statutes. .
with the Florida EgELCode.
�5.
OWNER/AGE- ` BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test -Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house.
2/4/2021 2:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY rI4I:rKI IRT RFPf1RT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 38 Block 2 Waterstone 25 Bedrooms: 4
User Conditioned Area: 2523
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 38-2
Block/Subdivision: Waterstone
PlatBook:
Street: 8521 Waterstone Boule
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2523 22202.4
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2523 22202.4 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 208.9 ft 0
2523 ft2 ---- 0.44 0 0.56
ROOF
/
#
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2821 ft2 630 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2523 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2523 ft2 0.11 Wood
80 ft2 0.11 Wood
2/4/2021 2:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CI-IFCKI IST RFPnRT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing Solar Belo w
1 NW Exterior
Concrete Bloch - Int Insul
Main
4.1
48
6
8 0
388.0 ft2
0
0 0.6
0
2 NE Exterior
Concrete Block - Int Insul
Main
4.1
37
2
8 0
297.3 ft2
0
0 0.6
0
3 SE Exterior
Concrete Block - Int Insul
Main
4.1
51
3
8 0
410.0 ft2
0
0 0.6
0
4 S Exterior
Concrete Block - Int Insul
Main
4.1
6
2
8 0
49.3 ft2
0
0 0.6
0
5 SW Exterior
Concrete Block - Int Insul
Main
4.1
37
6
8 0
300.0 ft2
0
0 0.6
0
6 - Garage
Frame - Wood
Main
13
34
0
8 0
272.0 ft2
0
0.23 0.01
0
7 SW Exterior
Concrete Block - Int Insul
Main
4.1
23
6
8 0
188.0 ft2
0
0 0.6
0
8 NW Exterior
Concrete Block - Int Insul
Main
4.1
8
6
8 0
68.0 ft2
0
0 0.6
0
9 SE Exterior
Concrete Block - Int Insul
Main
4.1
6
0
8 0
48.0 ft2
0
0 0.6
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 NE
Insulated
Main
None
.25
3
6 8
20 ft2
2 -
Wood
Main
None
.25
2
8
6 8
17.8 ft2
3 SE
Insulated
Main
None
.25
2
4
6 8
15.6 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/ Wall
Overhang
# Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW 1
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
25 ft 0 in
0 ft 10 in
Drapes/blinds
None
2 NW 1
Vinyl Low-E Double
Yes
0.33
0.23
N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3 NE 2
Vinyl Low-E Double
Yes
0.33
0.31
N
7.5 ft2
13 ft 0 in
0 ft 6 in
None
None
4 NE 2
Vinyl Low-E Double
Yes
0.33
0.31
N
13.3 ft2
13 ft 0 in
2 ft 10 in
None
None
5 NE 2
Vinyl Low-E Double
Yes
0.33
0.21
N
32.4 ft2
7 ft 4 in
1 ft 4 in
Drapes/blinds
Exterior 5
6 NE 2
Vinyl Low-E Double
Yes
0.33
0.21
N
38.5 ft2
1 ft 4 in
2 ft 0 in
Drapes/blinds
Exterior 5
7 SE 3
Vinyl Low-E Double
Yes
0.33
0.23
N
9.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
8 SE 3
Vinyl Low-E Double
Yes
0.33
0.23
N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
9 S 4
Vinyl Low-E Double
Yes
0.33
0.23
N
12.5 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
10 SW 5
Vinyl Low-E Double
Yes
0.55
0.7
N
17.8 ft2
9 ft 10 in
0 ft 10 in
Drapes/blinds
None
11 SW 5
Vinyl Low-E Double
Yes
0.33
0.23
N
16.7 ft2
7 ft 2 in
0 ft 4 in
Drapes/blinds
Exterior 5
12 SW 7
Vinyl Low-E Double
Yes
0.33
0.23
N
30.0 ft2
9 ft 10 in
0 ft 4 in
Drapes/blinds
Exterior 5
13 SW 5
Vinyl Low-E Double
Yes
0.33
0.23
N
48.6 ft2
1 ft 4 in
1 ft2 in
Drapes/blinds
Exterior 5
GARAGE
# Floor
Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 620 ft2 620 ft2
64 ft
8 ft
1
2/4/2021 2:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000391
2590.3 142.11 266.8 .1312
7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 42 kBtu/hr cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ---- Air CFM 25 CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type Handler TOT OUT
QN RLF
Heat Cool
1 Attic 6 503.2 ft
Main
125.8 ft Proposed Qn Main --- cfm 151.4 cfm 0.06 0.60
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling j Jan Feb Mar
Mar
Heating f X] Jan HFeb HX
Apr
APr
Jul rj AugSe
May Jun Jul AuSeP
May rl
Jun rl rj
Oct Nov
Oct Nov
Dec
Dec
H
Venting [ ]Jan Feb Mar
[ A r [
Ma JunJulAug Se [
Oct X Nov
Dec
2/4/2021 2:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
.1
Thermostat Schedule:
HERS 2006 Reference
Hours
:Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
80
80
80
80
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
68
66
66
RA T
MASS
ass ype Area Thickness Furniture Fraction
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3
2/4/2021 2:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
8521 Waterstone Boulevard, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation ,
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1748.70 ftZ
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=13.0
272.00 ftz
c. N/A
R=
ftz
4. Number of Bedrooms
4
d. N/A
R=
ftZ
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2523.00 ftZ
6. Conditioned floor area (ftZ)
2523
b. Knee Wall (Vented)
R=19.0
80.00 ftz
7. Windows- Description
Area
c. N/A
R=
ftZ
a. U-Factor: Dbl, U=0.33
166.06 ftZ
12. Ducts, location & insulation level
R ftZ
SHGC: SHGC=0.23
a. Sup: Attic, Ret: Main, AH: Main
6 503.2
b. U-Factor: Dbl, U=0.33
70.92 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
C. U-Factor: Dbl, U=0.55
35.56 ftZ
a. Central Unit
42.0 SEER:15.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
20.83 ftZ
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
6.223 ft.
a. Electric Heat Pump
42.0
HSPF:8.50
Area Weighted Average SHGC:
0.288
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ftZ
a. Electric
Cap:
40 gallons
SHGC(AVG): N/A
EF:0.94
9. Floor Types
Insulation
Area
b. Conservation featuresNone
a. Slab -On -Grade Edge Insulation
R=0.0
2523.00 ftZ
b. N/A
R=
ftZ
Credits (Performance method)
Pstat
c. N/A
R=
ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature, Date:
Address of New Home:
City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/4/2021 2:07 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
M